Loading...
HomeMy WebLinkAboutNew Photovoltaic SystemCOVER PAGEAUTHORITIES HAVING JURISDICTIONBUILDING: ST. LUCIE COUNTYZONING: ST. LUCIE COUNTYUTILITY: FLORIDA POWER & LIGHT CO NEW PHOTOVOLTAIC SYSTEM 8.80 KW DC5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USAGENERAL NOTESVICINITY MAPSATELLITE VIEWSHEET INDEXCOVER PAGET-001G-001A-101SITE PLANATTACHMENT PLANRESOURCE DOCUMENT1.3.1 WORK INCLUDES:1.3.2 PV RACKING SYSTEM INSTALLATION - QUICK MOUNT PV1.3.3 PV MODULE AND INVERTER INSTALLATION - Q.CELL Q.PEAKDUO BLK ML-G10 400W / SOLAREDGE SE7600H-US / SOLAREDGEPOWER OPTIMIZER P4011.3.4 PV EQUIPMENT ROOF MOUNT1.3.5 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX1.3.6 PV LOAD CENTERS (IF INCLUDED)1.3.7 PV METERING/MONITORING (IF INCLUDED)1.3.8 PV DISCONNECTS1.3.9 PV GROUNDING ELECTRODE & BONDING TO (E) GEC1.3.10 PV FINAL COMMISSIONING1.3.11 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV1.3.12 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDINGCODE ATTACHMENT TYPE: ROOF MOUNT MSP UPGRADE: NOPROJECT INFORMATIONOWNERNAME:ELECTRICAL PLANLINE DIAGRAMPLACARDRESOURCE DOCUMENTA-102E-601E-603R-001R-002A-103RESOURCE DOCUMENTE-602ELECTRICAL CALCULATIONSRESOURCE DOCUMENTR-003RESOURCE DOCUMENTR-004R-005REV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-T-001HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USA HERMAN BOWERSNOTESDESIGN SPECIFICATIONOCCUPANCY: R3/SINGLE FAMILY RESIDENTIALCONSTRUCTION TYPE / FIRE RATING: 5-BGROUND SNOW LOAD : 0 PSFWIND EXPOSURE: CWIND SPEED : 160 MPHCONTRACTOR INFORMATION:CONTRACTOR NAME: PALMETTOCONTRACTOR ADDRESS: 1505 KING ST, CHARLESTON,SC 29405CONTRACTOR PHONE: (855) 339-1831PHONE: (772) 240-9161SCOPE OF WORKSYSTEM SIZE : STC : 22 X 400W= 8.80 kW DC PTC : 22 x 376.55W = 8.28 kW DC AC SIZE: 7.6 kW AC (22) Q.CELL Q.PEAK DUO BLK ML-G10 400W (1) SOLAREDGE SE7600H-US (22) SOLAREDGE POWER OPTIMIZER P401APPLICABLE CODES & STANDARDSIBC/IEBC 2018IRC 2018NEC 2017IFC NFPA702020 FLBC/FLEBC/FLRC - 7TH EDITIONMOUNTING DETAILA-1041.1.1 PROJECT NOTES:1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONALELECTRIC CODE (NEC) ARTICLE 690, ALL MANUFACTURER LISTING ANDINSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THEAUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES.1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PVSYSTEM INSPECTED PRIOR TO PARALLEL OPERATION.1.1.4 ARC FAULT PROTECTION (AFCI) AND PHOTOVOLTAIC RAPID SHUTDOWNSYSTEM (PVRSS) IS INTEGRATED WITH THE POWER OPTIMIZER IN ACCORDANCEWITH NEC 210.12 & 690.12 RESPECTIVELY.1.1.5 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE ISINTEGRATED WITH THE INVERTER IN ACCORDANCE WITH NEC 690.41(B)1.1.6 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVEINVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED ANDLISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PVMODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIREINVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703OR UL 1741 ACCESSORY1.1.7 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMPCOEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATEDACCORDING TO NEC 690.7.1.1.8 ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, ANDSOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWERSYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D).SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING ORLABELING [NEC 110.3].1.1.9 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE.IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES ANDSIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.1.2.1 SCOPE OF WORK:1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIMECONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITEREQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIORROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THISDOCUMENTBy Yuri at 8:54:15 AM, 3/17/2022 NOTESREV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-G-001HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USA 2.1.1 SITE NOTES:2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITHOSHA REGULATIONS.2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THISSYSTEM IS A UTILITY INTERACTIVE SYSTEM WITHOUT STORAGEBATTERIES.2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL, OR BUILDING ROOF VENTS.2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTINGAND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PERSECTION NEC 110.26.2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, ANDMAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVEDMANUFACTURER INSTRUCTIONS SUCH THAT THE ROOF COVERINGSERVES TO PROTECT THE BUILDING OR STRUCTURE.2.2.1 EQUIPMENT LOCATIONS:2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BYNEC 110.26.2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATEDFOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C).2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PVMODULES ACCORDING TO NEC 690.34.2.2.5 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THEINVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIEDPERSONNEL ACCORDING TO NEC APPLICABLE CODES.2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATEDFOR OUTDOOR USAGE WHEN APPROPRIATE.2.3.1 STRUCTURAL NOTES:2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TOCODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE ADESIGNATED SPACE BETWEEN MODULES, AND RAILS MUSTALSOEXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THEARRAY/SUBARRAY, ACCORDING TO RAI MANUFACTURER’SINSTRUCTIONS.2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED &SEALED PER LOCAL REQUIREMENTS.2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILLBE COMPLETEDAND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY ALICENSED CONTRACTOR.2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATERTHAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BESTAGGERED AMONGST THE ROOF FRAMING MEMBERS.2.4.1 WIRING & CONDUIT NOTES:2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FORTHEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS AREBASED ONMINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMITUP-SIZING.2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.2.4.4 VOLTAGE DROP LIMITED TO 3.0%.2.4.5 DC WIRING LIMITED TO INVERTER FOOTPRINT. OPTIMIZER WIRINGSYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS.2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE AOR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREEPHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHERCONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTEDSYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE[NEC 110.15].2.5.1 GROUNDING NOTES:2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIRPURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTSSHALL BE RATED FOR SUCH USE.2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43AND MINIMUM NEC TABLE 250.122.2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, ANDENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND250.136(A).2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZEDACCORDING TO NEC 690.45 AND INVERTER MANUFACTURERINSTRUCTIONS.2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPSAS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BYTHE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUSTBE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THEMANUFACTURER INSTALLATION REQUIREMENTS.2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGEDSUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT AGROUNDING CONDUCTOR TO ANOTHER MODULE.2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BECOLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC250.119]2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM ISINACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEMPROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ.2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1)AND (2) TO REDUCE FIRE HAZARDS2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTIONNOTES:2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCHTHAT WHEN THE SWITCH IS OPENED THE CONDUCTORSREMAINING ENERGIZED ARE CONNECTED TO THE TERMINALSMARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITYPERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGSSHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCESHOCK HAZARD FOR EMERGENCY RESPONDERS INACCORDANCE WITH 690.12(A) THROUGH (D).2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDINGTO NEC 690.8, 690.9, AND 240.2.6.6 OPTIMIZER BRANCHES CONNECTED TO A SINGLEBREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC110.3(B).2.6.7 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULTCIRCUIT PROTECTION ACCORDING TO NEC 690.11 ANDUL1699B.2.7.1 INTERCONNECTION NOTES:2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE INACCORDANCE WITH [NEC 705.12 (B)]2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTERCONTINUOUS OUTPUT MAY NOT EXCEED 120% OF BUSBARRATING [NEC 705.12(B)(2)(3)(b)].2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF THEOVERCURRENT DEVICE PROTECTING THE BUSBAR SHALLNOT EXCEED 120 PERCENT OF THE AMPACITY OF THEBUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BELOCATED OPPOSITE END OF THE BUS FROM THE UTILITYSOURCE OCPD [NEC 705.12(B)(2)(3)].2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUTCOMBINER PANEL, TOTAL RATING OF ALL OVERCURRENTDEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR.HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BEEXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C).2.7.6 FEEDER TAP INTERCONECTION (LOAD SIDE)ACCORDING TO NEC 705.12 (B)(2)(1)2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TONEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS INACCORDANCE WITH NEC 230.422.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWERSOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12 (B)(5)].By Yuri at 8:54:43 AM, 3/17/2022 JBINVMSPUMACDREV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-A-101HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USASITE PLAN 1SITE PLANSCALE:1/32" = 1'-0"NSEW(E) UTILITY METERLEGEND- JUNCTION BOXJB- VENT, ATTIC FAN (ROOF OBSTRUCTION)- PROPERTY LINE- FIRE SETBACK- CHIMNEY (ROOF OBSTRUCTION)- SKYLIGHT (ROOF OBSTRUCTION)- FENCEDELEON AVENUE 1MODULEQ.CELL Q.PEAK DUO BLK ML-G10400W2INVERTERSOLAREDGE SE7600H-US3OPTIMIZERSOLAREDGE POWER OPTIMIZERP4014MOUNTSQMLM-B-12, L-MOUNT ATTACHMENT5RAILIRONRIDGE XR-10-168M,XR10 RAILDRIVEWAY(N) VISIBLE LOCKABLE LABELED ANDFUSIBLE AC DISCONNECT (UTILITYDISCONNECT)(N) SOLAREDGE SE7600H-US INVERTERARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(SQ. FT.)ROOFAREA(SQ. FT.)ROOFAREACOVEREDBY ARRAY(%)#18169.0311.5454.259#26126.780245.8851.562#38169.040694.7024.333(E) MAIN SERVICE PANEL(INSIDE HOUSE)KILLARNEY AVENUE170'-9"2 0 4 ' - 7 " 227'-9" 3 8 ' - 3 "97'-8"52'-8"10'-4"5 1 ' - 6 "By Yuri at 8:56:00 AM, 3/17/2022 JBINVMSPUMACD1111111111122222222222ELECTRICAL PLAN REV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-A-102HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USA1ELECTRICAL PLANSCALE:1/8" = 1'-0"NSEWROOF SECTION(S)TILT - 20°AZIMUTH - 174°MODULE - 8TILT - 18°AZIMUTH - 174°MODULE - 6TILT - 18°AZIMUTH - 264°MODULE - 8ROOF 1ROOF 2ROOF 31- MODULE STRING2- MODULE STRINGLEGEND- JUNCTION BOXJB- VENT, ATTIC FAN (ROOF OBSTRUCTION)- PROPERTY LINE- FIRE SETBACK- CHIMNEY (ROOF OBSTRUCTION)- SKYLIGHT (ROOF OBSTRUCTION)- FENCE(N) CONDUIT RUNIN THE ATTICROOF 11MODULEQ.CELL Q.PEAK DUO BLK ML-G10400W2INVERTERSOLAREDGE SE7600H-US3OPTIMIZERSOLAREDGE POWER OPTIMIZERP4014MOUNTSQMLM-B-12, L-MOUNT ATTACHMENT5RAILIRONRIDGE XR-10-168M,XR10 RAIL(E) UTILITY METER(N) VISIBLE LOCKABLE LABELED ANDFUSIBLE AC DISCONNECT (UTILITYDISCONNECT)(N) SOLAREDGE SE7600H-US INVERTER(E) MAIN SERVICE PANEL(INSIDE HOUSE)ROOF 2ROOF 3 12'-4" 1'-2"1'-0"13'-10"7'-8"12'-4" 1'-3"1'-6"17'-4"9'-3"12'-4"1'-2"6'-3"13'-10"34'-2"4'-0"ATTACHMENT PLAN REV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-A-103HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USA1ATTACHMENT PLANSCALE:3/16" = 1'-0"MOUNTING PATTERN SAMPLEMAX. 48"MAXIMUM MOUNT SPACING: 48"MOUNT PATTERN:STAGGEREDALL HARDWARE, INCLUDING MOUNTINGAND RACKING, TO BE INSTALLED PERMANUFACTURER SPECIFICATIONS.- CLAMP-MODULE MOUNT- RAIL- RAFTERROOF 1TILT- 20 DEGAZIMUTH - 174 DEGROOF 3TILT- 18 DEGAZIMUTH - 264 DEGROOF SECTION(S)ROOF MATERIAL -COMPOSITE SHINGLEROOF 1ROOF 2ROOF 3ROOF MATERIAL - COMPOSITE SHINGLEROOF MATERIAL -COMPOSITE SHINGLEROOF 2TILT- 18 DEGAZIMUTH - 174 DEGBy Yuri at 8:56:56 AM, 3/17/2022 MOUNTING DETAILREV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-A-104HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USA1MOUNTING DETAILIRONRIDGE XR-10 RAILQMLM-B-12 L-MOUNT(E) COMPOSITE SHINGLE ROOF5/6"x4" SS LAG BOLT WITH MIN 2 12"THREADEMBEDMENT,SEALED PENETRATIONRAFTERS GROUNDING END/MID CLAMPSOLAR MODULEBy Yuri at 8:57:01 AM, 3/17/2022 =SOLAREDGE SE7600H-US (240V)7600W OUTPUT: 240 VAC, 32A99% CEC WEIGHTED EFFICIENCYNEMA 3R, UL LISTED, INTERNAL GFDIWITH INTEGRATED DC DISCONNECTACDC3-+-++-++++---2-+-13==========JUNCTION BOX600 V, NEMA 3UL LISTED-+-++-++++---2-+-13==========Q.CELL Q.PEAK DUO BLKML-G10 400W2101110111GGSOLAREDGE POWER OPTIMIZER P401DC Input Power - 400 wattsMaximum Input Voltage - 60 VdcMPPT Range - 8 to 60 VdcMaximum Input Current - 11.75 AdcMaximum Output Current - 15 Adc StringLimitations - 8 to 25 Optimizers,6000 watts STC per string maximumGL1L2NLOADLINEAC DISCONNECT:VISIBLE, LOCKABLE, LABELED60A FUSED, (2) 40A FUSES, 240VNEMA 3R, UL LISTED4GL1L2NGEXISTING GROUNDINGELECTRODE SYSTEMTO EARTHREF. NEC 250.52,250.53(A)SUPPLY SIDE TAPNSUPPLY SIDE TAP(E) MAIN SERVICE PANEL150A RATED, 240V(INSIDE GARAGE)(E) MAIN BREAKER240 V, 150A/2PNL2L1MTO UTILITY GRID(E)BI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240VMETER NO.: ACD76745GECLINE DIAGRAMREV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-E-601HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USA DC SYSTEM SIZE: 8.80 kW DC AC SYSTEM SIZE: 7.6 kW AC(22) Q.CELL Q.PEAK DUO BLK ML-G10 400W MODULES(2) STRINGS OF 11 MODULES CONNECTED IN SERIESPHASE CONDUCTOR QTY, SIZEAND TYPE PER CONDUITNEUTRALGROUND CONDUCTOR QTY, SIZEAND TYPE PER CONDUITCONDUITSIZECONDUIT TYPE14AWG #10PV-WIRE/USE-2,COPPERN/A1AWG #6BARE,COPPER EGCN/AFREE AIR24AWG #10THWN-2,COPPERN/A1AWG #10THWN-2,COPPER EGC3/4"EMT32AWG #8THWN-2,COPPER1AWG #8THWN-2,COPPER1AWG #10THWN-2,COPPER EGC3/4"EMT42AWG #6THWN-2,COPPER1AWG #6THWN-2,COPPERN/AN/AN/A3/4"EMT51AWG #6BARE,COPPERN/AFREE AIR1MODULEQ.CELL Q.PEAK DUO BLK ML-G10400W2INVERTERSOLAREDGE SE7600H-US3OPTIMIZERSOLAREDGE POWER OPTIMIZERP4014MOUNTSQMLM-B-12, L-MOUNT ATTACHMENT5RAILIRONRIDGE XR-10-168M,XR10 RAIL ELECTRICALCALCULATIONSREV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-E-602HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USA DC CONDUCTOR AMPACITY CALCULATIONS:ARRAY TO JUNCTION BOX :DC CONDUCTOR AMPACITY CALCULATIONS:FROM JUNCTION BOX TO INVERTER:POWER OPTIMIZER (OPTIMIZER P401) MAXIMUM INPUT POWER400W MINIMUM INPUT VOLTAGE8 VDC MAXIMUM INPUT VOLTAGE60 VDC MAXIMUM MODULE ISC11.75 ADC MAXIMUM OUTPUT CURRENT15 ADCPERCENT OF VALUESNUMBER OF CURRENTCARRYING CONDUCTORS IN EMT0.804-60.707-90.5010-20AMBIENT TEMPERATURE SPECS RECORD LOW TEMP0° AMBIENT TEMP (HIGH TEMP 2%)33° CONDUIT HEIGHT0.5" ROOF TOP TEMP55° CONDUCTOR TEMPERATURE RATE90° MODULE TEMPERATURE COEFFICIENT OF Voc-0.27%/°CINVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE7600H-US NOMINAL AC POWER7600 W NOMINAL OUTPUT VOLTAGE240 VAC NOMINAL OUTPUT CURRENT32EXPECTED WIRE TEMP (In Celsius)55°TEMP. CORRECTION PER TABLE (310.16)0.76NO. OF CURRENT CARRYING CONDUCTORS4CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1CIRCUIT CONDUCTOR SIZE10 AWGCIRCUIT CONDUCTOR AMPACITY40AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)18.75A1.25 X IscDERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.1630.40ATEMP. CORRECTION PER TABLE (310.16) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) XCIRCUIT CONDUCTOR AMPACITYRESULT SHOULD BE GREATER THAN (18.75A) OTHERWISE LESS THE ENTRY FORCIRCUIT CONDUCTOR SIZE AND AMPACITYAC CONDUCTOR AMPACITY CALCULATIONS:AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUITPER NEC 310.15(B)(2)(c)22°EXPECTED WIRE TEMP (In Celsius)33°+22° = 55°TEMP. CORRECTION PER TABLE (310.16)0.76NO. OF CURRENT CARRYING CONDUCTORS4CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.8CIRCUIT CONDUCTOR SIZE10 AWGCIRCUIT CONDUCTOR AMPACITY40AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)18.75A1.25 X IscDERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.1624.32ATEMP. CORRECTION PER TABLE (310.16) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) XCIRCUIT CONDUCTOR AMPACITYRESULT SHOULD BE GREATER THAN (18.75A) OTHERWISE LESS THE ENTRY FORCIRCUIT CONDUCTOR SIZE AND AMPACITYNO. OF INVERTER1EXPECTED WIRE TEMP (In Celsius)33°TEMP. CORRECTION PER TABLE (310.16)0.96NO. OF CURRENT CARRYING CONDUCTORS3CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1CIRCUIT CONDUCTOR SIZE8 AWGCIRCUIT CONDUCTOR AMPACITY50AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B)40.00A1.25 X MAX INVERTER OUTPUT CURRENTDERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.1648.00ATEMP. CORRECTION PER TABLE (310.16) XCONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) XCIRCUIT CONDUCTOR AMPACITYRESULT SHOULD BE GREATER THAN (40.00A) OTHERWISE LESS THE ENTRY FORCIRCUIT CONDUCTOR SIZE AND AMPACITYSOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #Q.CELL Q.PEAK DUO BLK ML-G10 400W VMP37.59V IMP10.64A VOC45.06V ISC11.16A TEMP. COEFF. VOC-0.27%/°C PTC RATING376.55W MODULE DIMENSION73.97"L x 41.14W x 1.25"D (In Inch) JBINVMSPUMACDPV ARRAYPLACARDSPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:CAUTIONREV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-E-603HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USAN WARNING: PHOTOVOLTAICPOWER SOURCEEMERGENCY RESPONDER:SOLAR ELECTRIC PV PANELSTHIS SOLAR PV SYSTEMIS EQUIPPED WITH RAPIDSHUTDOWN TURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN THE ENTIREPV SYSTEM.AC DISCONNECTWARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALS.TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZED IN THEOPEN POSITION!!PHOTOVOLTAIC SYSTEM AC DISCONNECT!!OPERATING VOLTAGE:____VOLTSOPERATING CURRENT:____AMPSAC COMBINER BOXPHOTOVOLTAICMICROINVERTERSLOCATED UNDEREACH PV MODULE INROOFTOP ARRAYPHOTOVOLTAIC SYSTEM EQUIPPED WITHRAPID SHUTDOWNRATED AC OUTPUT CURRENT:____NOM. OPERATING VOLTAGE:____DUAL POWER SUPPLYSOURCES: UTILITY GRID AND PVSOLAR ELECTRIC SYSTEMWARNING!!___________KW SOLARDISCONNECT LOCATEDFT___FT___INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!PHOTOVOLTAIC AC DISCONNECT SWITCHRATED OUTPUT CURRENT: 32 AMPSNOMINAL OPERATING VOLTAGE: 240 VOLTSMAXIMUM VOLTAGE .MAXIMUM CIRCUIT CURRENTMAX RATED OUTPUT CURRECTOF THE CHARGE CONTROLLEROR DC-TO-DC CONVERTER(IF INSTALLED) .VAA4801530SOLAR CONNECTIONSUPPLY SIDE TAP!(N) PV DISCONNECT(E) MAIN SERVICE PANEL(INSIDE HOUSE)(E) UTILITY METER REV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-R-001HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USARESOURCEDOCUMENT REV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-R-002HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USARESOURCEDOCUMENT REV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-R-003HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USARESOURCEDOCUMENT REV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-R-004HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USARESOURCEDOCUMENT REV SHEET TITLEDATEDESCRIPTION REVISIONS SIGNATURE WITH SEAL PROJECT NAME & ADDRESSDRAWN DATEDRAWN BY03/17/2022ASSHEET NUMBERREVIEWED BY-R-005HERMAN BOWERS 5900 DELEON AVENUE, FORT PIERCE, FL, 34951, USARESOURCEDOCUMENT