Loading...
HomeMy WebLinkAboutSLC 2202-0090 Revision PackageOFFICE USE ONLY: DATE FILED: REVISION FEE: LOCATION/SITE ADDRESS: 11850 Appaloosa Ct Port St Lucie, FL 34987 PERMIT # SLC 2202-0090 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: Change 500 gal aboveground LP tank installation to 500 gal UNDERGROUND LP tank installation and add line to BBQ CONTRACTOR INFORMATION: STATE of FL REG.ICERT. #: LG-01237 BUSINESS NAME: Ferrellgas QUALIFIERS NAME: Tom Fite ADDRESS: 3232 SE Dixie Hwy CITY: Stuart STATE: FL PHONE (DAYTIME): 661-719-1165 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: ST. LUCIE CO CERT. #: 31370 ZIP: 34997 FAX: 772-287-3456 -1,2-11^1. ZIP: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: SLCCC: 9123109 Revised 06130117 n m 00 O -q T Z = m w cn C� D Q m C D n y -L/II O D y r O m to Dr rn m m Z m m NJ Oo C n r m A r- m i.s N O C Z D -D_i -n r o ".' G) a-i U Q O � Ln In � D G) a n a o r iJ1 C? a p o O m m CDO> W 0 437 (D ER <0 O CO n n _n cD o m O p c c 0 m �_ o" a (n E O Q vv r A r W D (n D v -� O � O x O w x O O n N w r�rl O N W N VLU fD to CD 0) ::o n CJ n m W Iv w X D V1 n Z w V N RI r m 41 Ln A 4 C C 00o m w �� < � y S P r:.+i.� - Ji��-}.: .fir, :. •, y.�:" W'* WHY CHOOSE QUALITY STEEL UNDERGROUND TANKS? • 120- 1,990 WG CAPACITY • General Specifications • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1. • Complies with NFPA 58. • Rated at 250 psig from -200 F to 125" F. All vessels registered with National Board. • Two service options available: • Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AGIUG dome • Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with steel AGIUG dome • Family & employee owned • Financing and leasing available • Customized delivery programs available HOW DO I FIND MY SALES REP? Visit our website, www.propanetank.com to view a list of our reps. Once on our site you'll be able to choose the Commercial options and from there you'll be taken to a list of US states where you can choose your location and view the contact information for your local sales rep. If you don't see your sales rep, please give us a call at 800-345-2495. Our manufacturing locations are strategically located to help serve your tank needs. OHIO LOCATION 721 Graham Drive Fremont, OH 43420 .... ..... ---. 1 UTAH LOCATION 5601 Axel Park Rd. West Jordan, UT 84081 801-280-1133 HOME OFFICE 2914 U.S. 61 Cleveland, MS 38732 800-345-2495 Consult our dimension and specification chart below to find the tank that best fits your needs. Visit our website at www.propanetank.com for more information. r�>tr■>tyaretira OVERALL HEIGHT LEG SPACING LEG WIDTH �. LEG WIDTH APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG* WIDTH LEG** SPACING WEIGHT (Ibs.) **QUANTITY FULLLOAD PERSTACK 120 wg. 24 Ellip. 5'-811 31 1 1 1/2 or 3'-11" 260 108 196 16 1 12 *250 wg. 30" Hemi. 7'-10" 3'-8" 1'-5" 4'-11" 480 54 9 *320 wg. 30" Hemi. 9'-7" 3'-8" 1'-5" 5' 620 45 9 500 wg. 37 1/2" Hemi. 10, 4'-2" 1'-8" 5' 950 37 30 8 6 1000 wg. 41" Hemi. F 16' 4'-5" 1 1'-8" 1 10'-1" 1,800 17 15 6 5 1450 wg. 461/2" Ellip, 17'-4" 4'-11" V-9" 11'-7" 2,650 12 4 1990 wg. 46 1 2" Ellip. 23'-11" 4'-11" V-9" 16' 3,520 8 4 Dimensions and specifications shown are approximate. Individual vessels may vary Leg spacing +/- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standard tanks - no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on center. 1450 wg. and up as shown above. "* Full load and stack quantities vary by shipping location. Check with your salesperson for details. QUALITY STEEL Because Quality Steel Means QuaWy Tanks * think Yan 101 SUDIMIM9 BSA M21MMLV£6 * HOME OFFICE 2914 U.S.61 Cleveland, MS 38732 800-345-2495 OHIO LOCATION 721 Graham Drive Fremont, OH 43420 419-334-2664 UTAH LOCATION 5601 Axel Park Ind. West Jordan, UT 84081 801-280-1133 Qua€ity Steel 612017 S2 STORAGE TANK IS ADEQUATELY ANCHORED TO PREVENT FLOATATION, COLLAPSE OR LATERAL MOVEMENT DURING THE BASE FLOOD EVENT, ALL WORK SHALL BE IN ACCORDANCE WITH NFPA 54-58, NATIONAL FUEL GAS CODE AND FLORIDA FUEL GAS CODE 2020 & FLORIDA BUILDING CODE 2020. TANKS INSTALLED IN TRAFFIC AREAS SHALL BE PROTECTED WITH GALV. STEEL SCHEO. 80 PIPE BOLLARDS (4"4) 6' LONG X 3' BURY DEPTH WITH CAP 0 3' O.C. PROPANE TANK BUOYANCY MAX BUOYANCY = pOg*Vkmk = 1.94 slug/ft' * 32.2 ft/s' * 66.84 ft' = 4176 LBS NET BUOYANCY = MAX BUOYANCY — WEIGHT OF EMPTY TANK = 4176 LBS — 871 LBS = 3305 LBS FORCE ON J" CABLE = 3305 / 2 = 1653 LBS TENSILE STRENGTH OF A" CABLE = 9800 LBS / 5 = 1960 LBS FORCE ON AUGER ANCHOR = 1653 / 2 = 827 LBS MIN. PULL—OUT RESISTANCE OF AUGER ANCHOR = 1360 LBS LP TANK 4" 7xl9 GALV. AIRCRAFT CABLE 2 TOTAL (IN POLY. SLEEVE) AUGER ANCHOR, 36" LONG W/ 6"0 HELIX 4 TOTAL SIDE ELEVATION SCALE 1/4" = 1'-0" GRASS 11 LP TANK _U 17LB. ANODE BAG 1 Ferrellgas 3232 SE Dixie Hwy. Stuart, FL 34997 Fort Pierce Eng "eering, Inc. Dependable Mech,ricnl, Plecnicnl & Plumbing Design C.A. No. 28173 315 South 71h Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fnx:772 672-4637 No 6090P �— EXCAVATION SIZE: t 12'L- x-4W-x- 4.5'D ` eel —{�" 7x19 GALV.� kid ur -5���� AIRCRAFT CABLE 9e m. omvNr..n,� STRAPPING BOLT APPROVED: EJS DRAWING NUMBER AUGER ANCHOR, 36" Didtally slgn^ed�by Eric svpboda. Ddobe crob visa Lsi os'aP T-1 LONG W/ 6"0 HELIX z¢Sotiis�zoo h""sin°, FRONT ELEVATION SCALE 1/4" = 1'-0" LP500 ANODE SALES COMPANY Add: Design Tel: Installation Face: Told -free: Materials Site: Surveys Email: Prepackaged Magnesium Anodes 124 N 22nd Ct. Grand Junctions, CO 81501 970 2434149 970 263-7295 888-609-9766 www.anodesalesco.corn hans@anodesystems.com jamesC anodesystems.com Magnesium anodes have the highest protection capability of any galvanic material. Magnesium is tow on the noble scale, and therefore corrodes easily. We have Magnesium Anodes in a range of designs which are specifically crafted to offer different conductive properties and connection options to snit any type of structures. 99 Bare & Bagged Anode 179 Bare & Bagged anode AL '.Magnesium Size �x 7x L Pre-pacl 9W 3.5x33x 13 26 17, D3 3_5s3.5x24 40 Chemical Composition (%) AST.V BSJ3-.WC Aluminum 0.01 Zinc - ]via€€gas€csc 0S0 - l 30 Silicon 0.05 Copper 0.005 Nickel el 0.001 Iron 0.01 Other 030 Magnesium Rcmainin; Anode 0 SV ) Pallet Quantity 50 50 Electrochemical Properties (-S' ) Open Voltage 1.70 - 1.75 Closed Voltage 1 _S8 - 1.62 Efficiency :55 Each anode has a plated steel core with 10 feet of #.12 TW insulated lead wire attached with solder. Packaged anodes have a backfill mixture consisting of 75% Gypsum, 20% Bentonite and 5% Anhydrous Sodium Sulphate. Applications include UST's, Pipe, AST bottoms or other carbon steel in contzet with the soil. PROPRIETARY BACKFILEPDXYRFSIN — )RE LF.A€)-WIRE' COTTON SAG NODE Magnesium Anodes NFPA 58-2017 and 2020 Editions Liquefied Petroleunt Gas Code TIA Log No.: 1480 Reference: Table 16.1 (n) Comment Closing Date: June 17, 2020 Submitter: Tom Dunn, Iowa Propane Gas Association v vw.nfpaorg!58 1. Revise Table 16. l(n) to read as follows (highlighted to show corrections): v`' Gravity_.1.52 n --s Dk-T —v--In,S-6R-F-1In. I)R-T101/41.pDR Wstic Pipe J� �DtR 11 2 In. SOR 11 Length 9.33 11 11 - 5 IM (n nAn% M QAnN I f I nnrol it 11.% (I.SS4) (1.943) 30 2140 7740 13420 20300 36400 40 1840 3670 6630 11480 1.7300 31200 50 1630 3260 5870 10180 15400 27600 60 1470 2950 5320 9220 13900 25000 70 1360 2710 4900 8480 1280D 23000 80 1260 2530 4560 7890 11900 21400 90 1180 2370 4270 7400 11200 20100 100 1120 2240 4040 6990 10600 19000 125 990 0U,'k 3580 6200 9360 16800 150 897 3240 5620 8480 15200 . . ........ . . 175 826 2980 5170 7800 --.- 14000 200 778 MIA 2780 4810 7260 13000 225 721 MOM 2600 4510 6810 12200 250 681 #ftik 2460 4260 6430 11600 275 646 ........ . ...... 2340 4050 6110 11000 300 . 617 WO ... .. ......... .. 3860 5830 10470 350 567 2050 3550 5360 9640 400 528 1910 3300 4990 8970 450 ... ....... 495 ..... ... 94� 3100 4680 8410 Soo 468 ..... .. . ........... 11-1.1— Mg� ..... ... 2930 ...... 4420 ....... .. ......... . . 7950 W -- 600 424 2650 4010 7200 700 390 2440 3690 6620 800 363 "M #am 2270 3430 6160 900 340 2130 3220 5780 1000 322 2010 3040 5460 1500 258 'o-4,41,60 441 -94' 4390 2000 221 ------ 3750 I� PROPANE 1 NATURAL GAS k QUICK DISCONNECT COUPLINGS a6, FW. C.S.A. GAS INTERCHANGE QUICK DISCONNECTS - CSA certified to Z21.411CSA 6.9 for Natural Gas and LP -Gas — air mixtures ,eR - All Size Quick Disconnects Rated To 60 RS,I, c u5 • Sizes 114, 318, 112 & 314 Quick Disconnects Are Rated To A Temperature -40OF (-40°C) • Sizes 1, & 1-114 Quick Disconnects Are Rated To A Temperature -20°F (-29°C) Quick Disconnect BTU Capacity Flow capacities are based on 0.64 specific.. gravity 0 0.3" w.c. pressure drop) 114 318 112 314 1 1-114 50,000 85,000 120,000 260,000 325,000 535,000 VALVED COUPLER -BRASS NIPPLE - BRASS Body Body PART No. Size Pipe PART No. Size Pipe QD-GMC4-4F 114 114 FPT QD-GMRVN4-4M 114 114 MPT QD-GMC6-6F 318 318 FPT QD-GMN6-6F M 318 FPT QD-GMC8-8F 112 112 FPT QD-GMN8-8F 112 112 FPT QD-GMC12-12F 314 314 FPT QD-GMN12-12F 314 314 FPT QD-GMC16-16F 1 1 FPT QD-GMN16-16F 1 1 FPT 00-GMC20-20F 1-114 1-114 FPT QD-GMN20-20F 1-114 1-114 FPT GAS QD Y-SPLITTER WITH VALVED COUPLERS Body PART No. Size QD-GMC4-Y 114 QD-GMC4-YP Retail Packaged QD-GMC6-Y 318 QD-GMC6-YP Retail Packaged Style Y Splitter SIZE COUPLER PLUG NIPPLE CAP 114 OD-RVSDC-4 318 QD-GMDP-6 QD-GMDC-6 Y Splitter 112 QD-GMDP-8 QD-GMDC-8 314 QD-GMDP-12 QD-GMDC-12 187 Application Ideal for use as a first stage regulator on any domestic size ASMB or DOT container in propane gas installations requiring up to 1,500,000 LISTED BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Feahxres • Compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. • Large threaded W F.NPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters. • Non Adjustable • Large flow orifice resists freeze ups due to water concentration in LPG vapor. • Design provides for good flow regulation at both high and low container pressures. • Built in relief valve and travel stop comply with NFPA 58 over pressure requirements. • Incorporates %" F.NPT downstream pressure tap for an easy inline check of the regulator's delivery pressure. • Molded diaphragm provides an o-ring type sea] between the body and bonnet. • Body and bonnet are assembled in the USA using the unique, patented RegUlok seal system. • Fully painted in brilliant red for complete corrosion protection. • Mounting bracket available as an accessory: part number 2302-31. Materials Body............................................................................................Zinc Bonnet......................................................................................Zinc Spring....................................................................................... Steel Seat Disc.................................................................Resilient Rubber Diaphragm...........................Integrated Fabric and Synthetic Rubber Information LV3403TR 3.56" 310 FLOW PROPANE LV3403TR W F.NPT %" F.NPT 7132" 10 PSIG Over Outlet 1,500,000 LV3403TRV9 9.00 Maximum flow based on inlet pressure 20 PSIG higher than the reguialor setting and delivery pressure 20%lower than the regulator selting and delivery pressure 20% lower than the setting, A14 JR&MY 100 RagO Dr. Elon, NC 27244 USA www.regoproducts com +1 (336) 449-7707 Application Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11" w.c. Ideal for medium commercial installations, vapor meter installations and normal domestic loads. Features • 90 degree right angle inlet to outer connection for meter or standard installations. • Large vent helps to prevent blockage and has'/" F. NPT for vent piping. • With 15 PSIG inlet pressure, regulator is designed to not pass more than 2 PSIG with the seat disc removed. • Replaceable valve orifice and valve seat. • Straight line valve closure reduces wear on seat disc • Unique bonnet vent profile minimizes vent freeze over when properly installed. • Large molded diaphragm is extra sensitive to pressure changes. • Built in pressure tap has plugged ''/a" F. NPT outlet. Plug can be removed with a 3/16" hex alien wrench. • Select Brown Finish Right Angle Design Can mount directly to vapor meter. It is also suitable for mounting directly to the house piping. It will retrofit into existing installations that are currently using a 90 degree, right angle regulator. Materials Body........................................................................... Die Cast Zinc Bonnet........................................................................ Die Cast Zinc Nozzle Orifice......................................................................... Brass Spring...................................................................................... Steel Valve Seat Disc ..................................................... Resilient Rubber Diaphragm ......................... Integrated Fabric and Synthetic Rubber �rRwb MO 1 Information LV 4403BGGBA series 90 0 J• In � 3 51. a r M U Attacbedto Vapor Meter wl Mounting Bracket LV4403866RA 3 11" w.c. at 10 LV44o3866RAB'• /+W F. NPT /" F. NPT 3116" PSIG inlet 9° to 13" w.c. Over Inlet 1,000,000 • Maximum flow is based on 10 PSIG inlet and 9" w c delivery pressure. Mounting Bracket Included. 100 Rego Dr. Elon, NC 27244 USA www regoproducts,cam +1 (335) 449-7707 �EG� A21 11 42114/21,:07 PM 35516_33260_1.jpg (800x80p) o < m � w O to � � n CD n c 0 A 3 N � c N N � fNAIk vl! � f uv4o �&S ,c(eoc-e f �6 ApPx-f 00sC", L'- �- � . p,�, be- 3Y ,97 z Lrt 1� w VL` URAL -f 23 s. '" ' uw 1 j (266) https://pas[c.govlfmageSketchesisketcft;35/35516_39264_1 Jpg 1/2