HomeMy WebLinkAboutAPPROVED, NOA 2BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL16177-R3
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Custom Window Systems Inc.
Address/Phone/Email 1900 SW 44th Avenue
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Authorized Signature Jay Lathrop
jlathrop@cws.cc
Technical Representative Jay Lathrop
Address/Phone/Email 1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Quality Assurance Representative Jay Lathrop
Address/Phone/Email 1900 SW 44th Ave.
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Category Windows
Subcategory Single Hung
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Lucas A. Turner
Florida License PE-58201
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 07/21/2030
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL16177_R3_COI_EvalReport812D.pdf
Referenced Standard and Year (of Standard)Standard Year
AAMA/WDMA/CSA/101/I.S.2/A440 2008
ASTM E1886-13a 2013
ASTM E1996-17 2017
PA TAS 201/202/203 1994
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw...
1 of 2 12/29/2020, 3:44 PM
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL16177_R3_Equiv_8100 LM Equivalency.pdf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/08/2020
Date Validated 08/09/2020
Date Pending FBC Approval 08/19/2020
Date Approved 10/13/2020
Summary of Products
FL # Model, Number or Name Description
16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +70/-70
Other: SH-8100 PVC Impact, no sill anchors required. Safety
glazing required on outer lite above 30 ft. in HVHZ. Glass
complies to ASTM E1300.
Installation Instructions
FL16177_R3_II_CWS-812D.pdf
Verified By: Lucas A. Turner 58201
Created by Independent Third Party: Yes
Evaluation Reports
FL16177_R3_AE_EvalReport812D.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw...
2 of 2 12/29/2020, 3:44 PM
8100 PVCSINGLE HUNGIMPACTCWS-812DBAT06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET6 OF 6LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.VERTICAL SECTIONTYPICAL SILL ANCHORAGEA6B6HORIZONTAL SECTIONTYPICAL JAMB ANCHORAGEINSTALLATION DETAILSTYPICAL HEAD ANCHORAGESUBSTRATE TYPEANCHOR TYPEMIN. EMBEDMENT MIN. EDGE DIST.CONCRETE (2.0 KSI MIN.)3/16" ITW TAPCON1-1/2"1-1/8"HOLLOW OR GROUT-FILLED CMU (117 PCF MIN.) 3/16" ITW TAPCON1"2"CONCRETE (2.85 KSI MIN.)3/16" ELCO ULTRACON1"1"GROUT-FILLED CMU (ASTM C-90)3/16" ELCO ULTRACON1-1/4"2-1/2"2X MIN. SOUTHERN PINE (G=0.55)3/16" ITW TAPCONOR ELCO ULTRACON1-3/8"7/8"2X MIN. SOUTHERN PINE (G=0.55)#10 WOOD SCREW1-3/8"7/8"16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN)#10-16 HILTI KWIK-FLEX OR ITW TEKS SELF-DRILLING SCREWFULL THREAD THRU 0.060"7/16"1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.)#10 GRADE 5 SELF-TAPPING / DRILLING SCREWFULL THREAD THRU 0.125"7/16"TABLE 1: APPROVED INSTALLATION FASTENERSMIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1MIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1PERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTPERIMETER SEALANTBY INSTALLERINSIDE AND OUTSEALANT BEHINDFLANGE BY INSTALLERSEALANT BEHINDFLANGE BY INSTALLERSEALANT BEHINDFLANGE BY INSTALLERINSTALLATION ANCHORSEE TABLE 1INSTALLATION ANCHORSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1SUBSTRATE BY OTHERSSEE TABLE 1FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: - MIN. 1/4" FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. - PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS.C6HORIZONTAL SECTIONBOX FRAME INSTALLATIONHEAD AND SILL SIMILAR FOR BOX INSTALLATIONMIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1CONTINUOUS DOUBLE 3/16" BEADS OF TREMGLAZE U1600 SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND BUCK BY INSTALLER.1/4" MAX SHIM1/4" MAX SHIM1/4" MAX SHIM8/05/2020