Loading...
HomeMy WebLinkAboutAPPROVED, METAL Docs:,. ohlition Viroftla Avon" PROPERTY INFORMATION Address: 1244 Nettles Blvd City / State / Zip: Jensen Beach, FI 34957 Parcel #: 4502-501-1431-00018 Zoning: HIRD APPLICATION INFORMATION Permit Number: 2203-0596 Permit Type: ROOF - METAL CONTRACTOR INFORMATION Contractor Name: Cameron Cooper Business Name: Florida Coastal Roofing Soultions Lic Business Addr: 1559 Se Niemeyer Cir City / State / Zip: Port St Lucie, FI 34952 REVIEWS AND COMMENTS REVIEW COMMENTS Page 1 Owner(s): Alfred Heins Jr / Christina Clark Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: Email: Office@Fcrsllc.Com Review Type Status Reviewed By Date Started Date Completed Date Released FRONT COUNTER REVIEW COMPLETE Ellen Vaughn 3/18/2022 3/18/2022 3/18/2022 Comment: NOTIFIED FOR PICK UP PENDING Ellen Vaughn Comment: PLANS EXAMINER REVIEW INCOMPLETE Andy Wentz 312912022 Comment: METHOD B DOES NOT MEET THE DESIGN PRESSURES PER TABLE IN PRODUCT APPROVAL. NEED TO 3/29/2022 HIGHLIGHT CORRECT METHOD AND TABLE. THE PROPERTY IS AN EXPOSURE D NOT B. 107 FLORIDA BUILDING CODE 2020 7TH EDITION 3/30/22, 12:09 PM Florida Building Code Online Businessa, Professional Regulation€ BCIS Home Log In j User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us j BCIS Site Map Links ( Search d[*r Product Approval ot,.00l USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL31652-R1 Revision 2020 Approved Metal Alliance Inc. 2120 SW Poma Dr. Palm City, FL 34990 (844) 638-2548 orders@metalalliance.com Tara Faulkner orders@metalalliance.com Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the David Eng Evaluation Report Florida License PE-81377 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 05/06/2029 Validated By James R Wally, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL31652 R1 COI 26ga 5V plywood.pdf Standard TAS 100 TAS 125 UL 580 Year 1995 2003 2006 hftps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvveRF2JcHYOR1 mXTYFQZ68OJ2Auoh9SAJCEGRPD2f9rQ%3d%3d 1 /3 Product Approval Method Method 1 Option D Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products 08/11/2020 08/13/2020 08/20/2020 10/13/2020 FL # Model, Number or Name Description 31652.1 i 01: 50ALLV 5V Crimp 26ga l 50ALLV 5V Crimp panel from 26ga (min) on 15/32" (min) i plywood or 3/4" (min) wood plank Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL31652 Rl II 26ga 5V plywood.pdf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes ; Design Pressure: +N/A/-206 Evaluation Reports Other: 206psf with 12"-12" pattern @ 8" oc, 117.75psf @ 16" FL31652 Rl AE 26ga 5V plywood.pdf Created by Independent Third Party: Yes _61 131652.2 02: 50ALLV 5V Crimp 032 Aluminum ! 50ALLV 5V Crimp panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank ! Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL31652 RI II 32AI 5V plywood.pdf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A ;Created by Independent Third Party: Yes Design Pressure: +N/A/-183.5 Evaluation Reports Other: 183.5psf with 12"-12" pattern @ 12" oc, 116.25psf @ FL31652 Rl AE 32AI 5V plywood.pdf 16" oc j Created by Independent Third Party: Yes 31652.3� 03: 50ALLV 5V Crimp 26ga 50ALLV 5V Crimp panel from 26ga (min) on 15/32" (min—) — 7 plywood or 3/4" (min) wood plank Limits of Use I Installation Instructions Approved for use in HVHZ: No ! FL31652 Rl II 26ga SV plywood-nonHVHZ.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A ( Verified By: David Eng, PE 81377 j Created by Independent Third Party: Yes Design Pressure: +N/A/-206 Evaluation Reports Other: 206psf with 12"-12" pattern @ 8" oc, 101psf @ 16" oc FL31652 Rl AE 26ga 5V plywood-nonHVHZ.pdf i Created by Independent Third Party: Yes 31652.4 04: 50ALLV SV Crimp 032 Aluminum ! -- — 50ALLV 5V Crimp panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL31652 R1 II 32AI 5V plywood-nonHVHZ.pdf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 g Impact Resistant: N/A i Created by Independent Third Party: Yes Design Pressure: +N/A/-183.5 Evaluation Reports Other: 183.5psf with 12"-12" pattern @ 12" oc FL31652 Rl AE 32AI 5V pIII ywood-nonHVHZ.pdf Created by Independent Third Party: Yes 31652.5 j 05: 50ALLCOR Corrugated 26ga 50ALLCOR 0.75" Corrugated panels from 26ga(min) on 2x4 j (nom) battens j Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL31652 Rl II 26ga 50AIICor battens-nonHVHZ.o f ; Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-161 Evaluation Reports Other: 161psf with fastener every peak, 101psf with fastener FL31652 Rl AE 26ga 50AIICor battens-nonHVHZ.pdf every other peak, battens @ 24" Created by Independent Third Party: Yes E31652.6 06: 50ALLCOR Corrugated 26ga 50ALLCOR 0.75" Corrugated panels from 26ga(min) on 15/32" _ (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: Yes i Installation Instructions i FL31652 Rl II 26ga 50AIICor plywood.pdf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A j Design Pressure: +N/A/-161 Created by Independent Third Party: Yes j Evaluation Reports Other: 161psf with fastener every other peak @ 12" oc, 101 FL31652 R1 AE 26ga 50AIICor plywood.pdf psf @ 16"oc Created by Independent Third Party: Yes https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvveRF2JcHYOR1mXTYFQZ68OJ2Auoh9SAJCEGRPD2f9rQ%3d%3d 2/3 Ak: METAULUAMi A Value Added Supplier of Metals 26ga 5V Crimp Panels 26ga (min) 5V Crimp exposed fastener panel over 15/32" (min) plywood Metal Alliance, Inc 2120 SW Poma Dr I Palm City FL 34990 Produced by Metal Alliance's Network of Approved Regional Manufacturers Product Description Exposed fastener 5V-style panel with a 24" coverage and a nominal rib height of 0.375" Product Material 26ga (min) steel 26ga is nominally 0.0185" with yield strength of at least 50ksi, and shall be corrosion resistant per FBC 1507.4.3 where required. Fastener #10 1.5-inch fastener with sealing washer Nominally 12"-12" fastener pattern Fasteners compliant with FBC 1506.6 where required. Substrate/Deck 15/32" (min) plywood or 3/4" (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 1 Gainesville FL FL PE 81377 1 FL CA 33344 www.TimberLakeCove.com 50ALLV4D 5V CRIMP 26GA SOP •'��cErvsF' �G' `: No.81377 _ STATE OF �� "�Z.ORO— isf0NAl.G *\ �ttlfilltll David E Eng S--'2020.08.12 07:44:57-04'00' This item has been digitally signed and sealed by D.E. Eng, PE, on the date indicated. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Underlayment: Comply with local building code or FBC 1507.1.1/1518.2 where required. Slope: Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required. Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511/1521, provided the existing roof meets the conditions required by the applicable code. Fire Barrier: Comply with FBC 1516.1 and 1516.2 where required. Maximum Allowable Loads & Installation Requirements: Method A: #10 x 1.5" fasteners in 12"-12" pattern at 16" o.c.: 117.75 PSF Method B: #10 x 1.5" fasteners in 12"-12" pattern at 8" o.c.: 206 PSF A factor of safety of 2 has been applied. Technical Documentation: This product has been tested to the TAS 125 / UL 580 standard by Intertek Testing (TST-1527), report J6368.19-450-44 RO and to TAS 100 under report J6368.06-450-44 RO. Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ) and 1518.9.1/1523.6.5.2.4 (HVHZ), as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems • TAS 125 - Standard Requirements for Meta► Roofing Systems • TAS 100 - Wind and Wind -Driven Rain Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. k Ik METAULce,,_! A Value Added Supplier of Metals Instructions: —a Select the appropriate load table that applies to the structure in question. Determine the design wind speed for the project location. Use the attachment method indicated for that windspeed within each roof zone. NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables below, the worst case was taken for each zone and reported using the standard zones 1-2-3: Zone i includes zones 1 and 1' Zone 2 includes zones 2e, 2r, and 2n Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple scheme, at the expense of some design efficiency. Contact Metal Alliance Inc for further information, or consult a licensed design professional. a- 2 2 3 �2 2 2 2 1 2 2 i 2 3 3 a 2 ; 1 X 1 2 1 3 2 2 3 a � L~ __J . L a: 10%OF LEAST HOIZONTAL DIMENSION OR OAh. WHICHEVER IS SMALLER. BUT NOT LESS THAN EITHER A".S OF LEAST HORIZONTAL DIMENSION OR 3FT (0.511). OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE. ROOF ZONES FOR GENERIC BUILDING METHOD A: • B: i i --- -12" (NOM) 12" (NOM) Use this load table for structures which meet the following criteria Are located in Exposure B area Have either a flat roof, or gable/hip roof with max slope of 450 Have a mean Roof Height of 30 feet or less Use this load table for structures which meet the following criteria: Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 450 Have a mean Roof Height of 30 feet or less FL31652.01: 26 a 50ALLV on 15/32" 121ywood FL31652.01: 26 a 50ALLV on 15/32" PlMood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A B B Zone 2: A A A A A A A A A A A Zone 2: A A A A A A B B B B B Zone 3: A A A A A A A A A B B Zone 3: A A A A A B B B B Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof less than 70, hip roof with nix slope of 45°, or gable roof with slope between 200 and 450 Have a mean Roof Height of 30 feet or less Use this eet the following criteria: Are I ated in B, C, or D exposure area ve either a flat roof less than 7°, hip raaf with max slope of 45°, or gable roof with slope between 00 and 450 Have a mean Roof Height of 30 feet or less I CI '211C=•S nA • GnAi i %1 -- f G74.1r1 Wind 105 110 120 130 140 150 160 170 180 190 2 0 Wind 105 110 120 130 140 150 160 170 180 19 200 Zone 1: A A A A A A A A A A Zone 1: A A A A A A A A A A B Zone 2: A A A A A A A A A A Zone 2: A A A A A A A B B B Zone 3: A A A A A A A A A A Zone 3: A A A A A B B B B I I I MEIA.i. ` A Value Added Supplier of Metals