Loading...
HomeMy WebLinkAboutAPPROVED- Underlayment Approval.pdf3116/22, 11:31 AM Florida Building Code Online Business & Professional Regula on aCIS Home Log in user Registration Not Topic Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search rProduct��i Approval ry USER: Public User Product AR,oreval isms > Product or Appjj0j on Search > _gppuWtion list > Application Detail FL * FL21895-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Sentry Building Innovations Address/Phone/Email 1209 Orange Street Wilmington New Castle, DE 19801 (604)612-5289 mseth@sentrybuilding.com Authorized Signature Marsha Hollandsworth Mhollandsworth@sentrybuilding.com Technical Representative Marsha Hollandsworth Address/Phone/Email 1209 Orange Street Wilmington New Castle, DE 19801 (843) 735-1773 Mhollandsworth@sentrybuilding.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments ` Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2025 Validated By )ohn W. Knezevich, PE Validation Checklist - Hardcopy Received I Certificate of Independence Rdf Referenced Standard and Year (of Standard) Standard Year A5TM D1970 2015 ASTM D4533 2015 ASTM D4798 2011 ASTM D4869 2016 ASTM D5035 2011 FRSA/TRI, Sixth Edition 2018 UL 1897 2015 Equivalence of Product Standards Certified By https://floridabuilding.org/prtpr_app_dtl.aspx?param=wGEVXQwtDqufjj9QzTt6YOnnxswE3xiGMTtl uPIXPB3FkJfAoT5OL3Q%3d%3d 112 3/16122, 11:31 AM Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/17/2021 Date Validated 12/20/2021 Date Pending FBC Approval 12/23/2021 Date Approved 02/08/2022 Summary of Products FL # 21895.1 Model, Number or Name Roofnado Synthetic Roofing Underlayments Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-97.5 Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure herein pertains to one underiayment assembly for use in tile roof systems. Refer to ER Section 5.8.3. Description Synthetic roofing underlayments Installation Instructions FL21895 R4 11 2021 12 17 FINAL ggf Verified By: Robert Nleminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL21895 R4 AE 2Q21 12 17 FINAL Y FL21895- R4.p-df Created by Independent Third Parry: Yes Contact Us :: 2601 Blair Stone Road Tallahassee FL 37d99 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer, Cogyrlaht 2007-2013 State of Florida.:: privacy Statement :: Accessipllity Statement :: Refund Staremen[ Under nonce law, email addresses are public records. It you do not want your a -mall address released in response to a public -records request, do not send electronic mail to this entity Instead, concert Me office by phone or by traditional mall. If you have any questions, please contact 850-487.1395. 'Pursuant to SeMon 455.275C1), Florida Statutes, effective October 1, Z012, licensees licensed under Chapter 455, F.S. must provide Me Department with an email address If they have one. The emalls provided may be used for aRldal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dick bp¢-. product Approval Acoapb: I R! Safe hffps:lMoridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDg49QzTt6YQnnxswE3xlGMTtluPIXPB3FkJfAoT5OL3Op/o3d%3d 2/2 NEMO l etc. Certecate of Authorization /l32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION Sentry Building Innovations Evaluation Report 1392S.02.17-1-R4 1209 Orange Street, Wilmington, FL2189S-R4 New Castle, DE 19801 Date of Issuance: 02/16/2017 (843) 735-1773 Revision 4:12/17/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 71 Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Roofnal Synthetic Roofing Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Evaluated" maybe displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPErnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: a+•:""•o,,,,y -;';Fy,..:- Robert J.M.Nleminen, P.E. jr_ The Robert �'•yfiyu.-9' rnine,P.E. n12/17/ingwasais does notzed s Nleminen,P.E.anR/1T/2021.TNsdoesrmtserveasan Florida Registration No. 59166, Florida DC4 ANE1983 - �'V•:.,,,;�,:,•° electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will It acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC fN NEMo I etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roofnado"' Synthetic Roofing Underlayments, as produced by Sentry Building Innovations, have demonstrated compliance with the following sections of the r Edition (2020) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section 1504.3.1 1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1, R905.2.8.2 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) 1507.3.3 / R905.3.3 TAS 110 Properties Wind resistance Material standard Tear strength Tensile strength Liquid water transmission Material standard Accelerated Weathering UL 1897 2015 ASTM D1970 2015 ASTM D4533 2015 ASTM D5035 2011 ASTM D4869 2016 FRSA/TRI, Sixth Edition 2018 ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date NEMO Evaluation Report 1m-ACT-I9-FBCER.08.19-2-R2 11/19/2020 NEMO(TST6049) UL 1897 4L-ACT-18-002.07.18-2 07/05/2018 NEMO (TST6049) AC152 4S-ACT-18-001.30.18-1B 10/08/2018 NEMO (TST6049) FRSA/TRI Manual 4S-ACT-18-001.11.18-2B 11/12/2018 QAI(TST9808) ASTM D1970 RJ5365P-3 04/26/2017 QAI(TST9808) ASTM D1970 (adhesion) RJ5365P-4 06/29/2017 QAI(TST9808) ASTM D1970 RJ7717-3 06/11/2020 QAI(TST9808) ASTM D1970 (adhesion) R17717-4 06/11/2020 QAI(QUA7628) Traceability/Inspections Service Confirmation 08/12/2019 QAI (QUA7628) Quality Assurance Florida BCIS Current PRODUCT4. DESCRIPTION: PRODUCT MATERIAL STANDARD PLANT(s) DEscRFnoN 4.1 RoofnadoTM 1507.1.1.1(2&3, Exception), India Synthetic polymer -based scrim -reinforced underlayment, AnchorDeck' 1507.1.1.1(5) / consisting of woven polyolefin base with a layer of R905.1.1.1(2&3, Exception), nonwoven polyolefin sheet and a polymer coating on the R905.1.1.1(5) back side, with a nominal unit weight of 2.25 Ibs/square. 4.2 Roofnado— 1507.1.1.1(2&3, Exception), India Synthetic polymer -based scrim -reinforced underlayment, StormTread•• 1507.1.1.1(5) / consisting of woven polyolefin base with a layer of R905.1.1.1(2&3, Exception), nonwoven polyolefin sheet and a polymer coating on the R905.1.1.1(5) back side, with a nominal unit weight of 3.80 lbs/square. 4.3 Roofnado"' 1507.1.1.1(2&3, Exception), India Synthetic polymer -based scrim -reinforced underlayment, ShingleLock"' 1507.1.1.1(5) / consisting of woven polyolefin base'wlth a layer of R905.1.1.1(2&3, Exception), nonwoven polyolefin sheet and a polymer coating on the R905.1.1.1(5) back side, with a nominal unit weight of 3.80 lbs/square. NEMO ETC, LLC Evaluation Report 23925.02.17-1-R4 Certificate ofAothon ation 432455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL21895-R4 Roofnado— Synthetic Roofing Underlayments Revision 4:12/17/2021 Page 2 of 6 MI 4.5 ONEIVIOletc. PRODUCT MATERIAL STANDARD PLANT(S) DESCRIPTION t ASTM D1970 (Table 1)' & United Self -adhering underlayment consisting of a synthetic top- . - FRSA/TRI 09-18 Arab facer, polymer modified bitumen and a release liner, Emirates available in rolls 36-inch x 67-ft with a nominal 60-mil thickness. Roofnado'" ASfM D1970 (Table I)' United Self -adhering underlayment consisting of a synthetic top- AnchorDeckTM Arab facer, rubberized adhesive and release liner, available in PSU Emirates rolls 36-inch x 67-ft with a nominal 40-mil thickness. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and (imitations concerning the use of foam plastic insulation. 5.5 Roofnado"* Synthetic Roofing Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable roof covers: TABLE 1: ROOF COVER OPTIONS FBC NON-NVIQ: 1507.2 1507.3 1507.4 & 1507.5 1507.7 1507.8 & 1507.9 Clay and Concrete Tile Metal Slate or wood UnderlaymeM Asphalt Shingles Slate -Type Mechanical Adhesive- Panels Shingles Shingles Shakes Attach Set Shingles RoofnadoTM Yes No No Yes Yes Yes No AnchorDeck" (residential) (residential) Roofnado'" Yes No No Yes Yes Yes No StormTread"' Roofnado'" Yes No No Yes Yes Yes No ShingleLockTM Rocifniscloq Yes LapLock'"PSU Yes Yes (See56.1) Yes Yes Yes (Joint strips, 1507.1.1.3/ 11905.1.1.3) Roofnado'" Yes AnchorDeck'"PSU Yes No No Yes Yes Yes (Joint strips, 1507.1.1.3/ fl905.1.1.3) I Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance for Roofnado'" LopLockm PSU and Roofnado"' AnchorDeck'" PSU. NEMO ETC, LLC Evaluation Report 13925.02.17-1-R4 CeMflmte ofAuthah atien 432455 77H EDITION (2020) FBC NON-HVH2 EVALUATION FL21895-R4 Roofnado'" Synthetic Roofing Underlayments Revision 4: 12/17/2021 Page 3 of 6 ONEMOletc. 5.6.1 Adhesive -set tile is limited to use of following underlayment /tile adhesive combinations. TABLE ILA: ALLOWABLE UNDERLAYMENT / TILE ADHESIVE COMBINATIONSZ Underlayment Adhesive Florida Product Approval Roofnadom LapLock"' PSIT'' ICP Adhesives "PolysetO AH-160" FL6332 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) Deck/sheathing (Optional) ASTM D41 plywood or OSB Roofnadc'" Lapl ock" PSU self -adhering Base sheet None ASTM D226, Type II felt Roofnado'" AnchorDeck self -adhering Deck / sheathing None plywood or OSB PSU 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturers installation instructions, but —for mechanically attached underiayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturers installation instructions, but not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1SO4.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 3A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. N1 Maximum Design Pressure =-97.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: Roofnado'" LapLock" PSU, self -adhered and back -nailed 12-inch o.c. 2 Refer to Tile Manufacturers or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance NEMO ETC, LLC Evaluation Report 13925.02.17-1-R4 Certificate of Authorization 432455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL21895-R4 Roofnado— Synthetic Roofing Underlayments Revision 4: 12/17/2021 Page 4 of 6 ONEMO etc. 5.9 Exposure Limitations: TABLE 3: ExPOSURE LiMITATIONs Underlaymem Prepared Roof Cover installation Type Maximum Exposure (days) Roofnado"' AnchorDeck'", Roofnado" StormTread'", Roofnado'" ShingleLock'" or Roofnado'" AnchorDeck"' PSU Mechanically attached 30 RoofnadoT" LapLock"' PSU � Adhesive -set tile 90 Mechanically attached 90 5.10 Tile Slippaee Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRER -DECK TILE INSTALLATIONS Underlaymeln Tile Profile Staging Method Maximum Slope RoofnadoTM LapLock"" PSU Flat or Lugged Max. 10-tile stack 4:12 6. INSTALLATION: 6.1 Roofnado'" Synthetic Roofing Underlayments shall be installed in accordance with the manufacturers published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 Roofnado" AnchorDeck"', Roofnado" StormTread'" or RoofnadoTM ShingleLock': 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R90S.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturers installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.3.2 Fasteners: Minimum fasteners shall be corrosion resistant, ring -shank cap nails shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3. 6.4 Roofnado" LapLock" PSU: 6.4.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1SO7.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.2 Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. NEMO ETC, LLC Evaluation Report 13925.02.17-1-R4 Cerrlfltare of Authorization a32455 7 T" EDITION (2020) FBC NON-HVHZ EVALUATION FL21895-R4 Roofnado" Synthetic Roofing Underlayments Revision 4: 12/17/2021 Page 5 of 6 NNEMO I etc. 6.5 Roofnadom AnchorDeck' PSU: 6.5.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. CAI Laboratories —QUA7628; (604) 527-8378, rnlansdowne@gei.orq END OF EVALUATION REPORT - NENIO ETC, LLC Evaluation Report 13925.02.17-1-R4 Certificate of Authormotion k32455 T" EDITION (2020) FBC NON-HVHI EVALUATION FL21895-R4 Roofnado- Synthetic Roofing Underlayments Revision 4: 22/27/2021 Page 6 of 6