HomeMy WebLinkAboutSite Plan DetailExisting (Partial) 1r4'=1� DEMOLITION NOTES: 1. THIS DEMOLITION PLAN SHOWS GRAPHIC AND WRITTEN INFORMATION CONCERNING THE EXISTING SPACE. THIS IS INCLUDED AS 'INFORMATION ONLY' REPRESENTING AVAILABLE RECORD INFORMATION OF THE ORIGINAL LEASE DRAWINGS PLUS FIELD NOTATIONS. SOME MODIFICATIONS MAY HAVE BEEN MADE AND NOT SHOWN. THIS INFORMATION IS FOR THE CONTRACTORS REFERENCE AS MAY BE USEFUL. 2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DETERMINE THE SCOPE OF WORK REQUIRED. 3. THE CONTRACTOR SHALL EXAMINE THE EXISTING BUILDING AND WORK SHOWN BY ALL CONTRACT DOCUMENTS TO DETERMINE THE SCOPE OF DEMOLITION REQUIRED WHETHER SPECIFICALLY SHOWN OR NOT. 4. REFER TO MECHANICAL & ELECTRICAL DEMOLITION NOTES AND MEP DOCUMENTS FOR EXTENT OF DEMOLITION OF THOSE SYSTEMS. 5, PROTECT ALL EXISTING STRUCTURE, SYSTEMS, FINISHES AND GENERAL CONSTRUCTION THAT ARE TO REMAIN THROUGHOUT THE COURSE OF THE WORK TO PREVENT DAMAGE OR LOSS. 6. CONTRACTOR IS TO VERIFY UTILITY LINE LOCATIONS AND MAINTAIN THOSE THAT SERVE OTHER PARTS OF THE BUILDING THAT ARE NOT AFFECTED BY THE DEMOLITION. 7. PRIOR TO INTERRUPTING OR OTHERWISE AFFECTING ANY SUCH OPERATING SYSTEM, UTILITY OR SERVICE, CONTRACTOR SHALL CONSULT WITH OWNERS REPRESENTATIVE TO ESTABLISH A MUTUALLY SATISFACTORY SCHEDULE FOR CUT OVER, CUT OFF DISRUPTION OR OTHER CHANGE IN THE OPERATION OF THE AFFECTED SYSTEM, UTILITY OR SERVICE. 8. ALL WORK WILL BE PERFORMED IN THE BEST WORKMANSHIP POSSIBLE IN ACCORDANCE WITH THAT TRADES BEST INDUSTRY STANDARDS. 9. NOISE AND DUST IS NOT TO BE DISRUPTIVE TO THE OCCUPIED AREA OF THE BUILDING. PROVIDE TEMPORARY PARTITIONS AS REQUIRED. 10. DEMOLITION IS TO BE DONE IN A CAREFUL AND ORDERLY MANNER 50 AS NOT TO DAMAGE FINISHES OR EQUIPMENT TO REMAIN. Demolition 114' = V-0' NOTES: 1. 2. 4. 5 54' MIN. A nwaom wvmwt+ore 12' 42°MIN. ALL DIMENSIONS ARE ABOVE FINISHED FLOOR. CRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/2 '. Z TOILET N PROVIDE 1 10 CLEARANCE BETWEEN RAIL AND WALL. Z Z ��PAPER PROVIDE GRAB BAR BACKING SUCH THAT BARS SUPPORT PULL STRENGTH OF NOT LESS THAN 250 LBS.,02FINISHES PER FBC:BUILDING CHAPTER 12 INTERIOR bENVIRONMENT `� 8• N v A FLOORS IN BATHROOMS, KITCHEN AND PUBLIC AREAS TO BE FINISHED WITH NON -SLIP DURABLE NON -ABSORBENT COATING. 2 ' MIN. 1 IN. B. PERIMETER WALLS AT BLOCK AREA 3 FT. FROM FLOOR WILL BE COATED WITH NON -ABSORBENT FINISH, WASHABLE IN BATHROOMS AREAS. ADA Toilet Details TRANSFER SIDE Improvements 3IB• =1'� FASTEN METAL TRACK TO EXISTING CEILING D x u ALUM. STUDS 19 O.C. WITH 10 j DRYWALL EACH SIDE b ro O 0 I METAL TRACK WITH 3W TRACK FAST PINS EVERY 12 O.C. VINYL BASE (TYPJ Typical Wall Section 3r4.=1,-0. ;00 3' 3_ZiOy U/Mr�way� L%� �rlr+y St. Lucie County FACILITIES 2399 Virginia Avenue Fort Pierce, Florida 34982-5652 General Contractor: Keyplan: ® = Area of Improvements Issues: No.: Date: Description: A 12.W.2021 REVIEW D 12.0s202, I -STING C 12.132021 PROPOSED FENCNQ D 01.M20M ADA FACUMS REVIEW o1 01.x2022 PSRMrr 02 01.28.2022 PERMIT REV. 01 03 01.29.2022 PERM7REV.02 Project: County Animal Shelter 3404 Midway Road Fort Pierce, Florida Drawing Title: ACCESSIBILITY IMPROVEMENTS Drawn: PWJ Issue Date: 0,2 ta= Checked: Scale: PWJ AS NOTED Project No.: Sheet No.: A-2 VC no . I ISig' Q�4Y�� �D�ate- / 01.2a.2 Peter W. Jones Date AR0017858 N 89'55'23E .POUND METAL GRATE PIPE C z LOCATE PAIR 5' GATES, FIELD VERIFY W w I 7 STORY BLOCK NEW 6' CHAIN j 11 STORAGE UNK FENCE 0 BUILDING ENCLOSURE _ o j I a I N 89' S523' E 208.1 V Di I a I m NEW 6'CHAIN N LINK FENCE ENCLOSURE j s i PARCEL B o F I � W I � wl �I j 3 <I WI j � ¢I e D o � � p NI g Nj ¢I Z O Z N I &CHAIN UN FENCE � I REMOVE PORTIONS OF EXISTING FENCING EXISTG. r I I �rD f - I .FREnSeffti� �,G `°wy A� ZZ� p�W I j ) NNCIE— _ I E gUOSURE e Dasm m>f Dw1wGWoo. EE1,oE NEw 4' 1-STORY BLOCK wncro%NRxwa ENIT BUILDING rNl ceml wl�cn GATE NEW 4' I i pO ACCESS .4- C.O. CPTIE-R. GATE GATEE,PUMP I I KIELD VERIFY I I I I ACCESSIBLE PARKING SPACE I TO BE LOCATED AT CLINIC REN ENTRY I I II I I I I 4\1ETERINARY YIC HARD SURFACE RYY MA PARKING I I II I I I I I I II I li I I I I I I I i I I I •I I I I I II I EXISTING SIGN N 89° 28' OB' W 210.00' (0)MAL _ =t=� 111112' ACP BOX Y, MIDWAY ROAD R.O.W. 1 ,I EXISTG. TR.' 1 x x x x �1 COUNTY SHELTER ACCESS ENTRY GATE PER FBC ACCESSIBILITY CHAPTER 4 ACCESSIBLE ROUTES, SECTION 404 ACCESSIBLE PARKING SPACE TO BE LOCATED AT VETERINARY CLINIC PRIMARY ENTRY PER FBC ACCESSIBILITY SECTION 205 PARKING SPACES, SUB -SECTIONS 208A, 208.2, AND 208.3 6O ACCESS AISLE 43 ACCESS x m\ x— 1 NEW 4' ACCESS GATE VETERINARY CLINIC PRIMARY ENTRY REFERENCE FBC ACCESSIBILITY 404.2.8 RE DOOR CLOSURES 3'-0' 3 TT 12:1 SLO PMIAX.) E NE AC LA SE SE REMOVE EXISTING CONCRETE WALKWAY Site Plan Detail: Accessible Route REFERENCE FLORIDA BUILDING CODE -ACCESSIBILITY 7TH EOITTON 114' = 1'-0' St. Lucie County FACILITIES 2399 Virginia Avenue Fort Pierce, Florida 34982-5652 General Contractor. Keyplan: ® = Area of Improvements Issues: No.: Date: Description: A 12.02.2021 REVIEW e 12...wl EXIsT o C 12.1-1 PROPOSE. FENCWG . 01=2022 ADA FACILE'ES E 01.102022 SREADAREVIEW F 01.192022 SRE REVISIONS Ol 01242022 FERNY w 01.2S2022 PUWIIr REV.01 Project: County Animal Shelter 3404 Midway Road Fort Pierce, Florida Drawing Title: SITE PLAN Drawn: Issue Date: PWJ 01.24.2022 Checked Scale: PWJ AS NOTED Project No.: Sheet No.: A-1 w� A roof �i tiyt �PtO gSA :e 'R00�ti22A4 �0;. 01.2a.2022 Peter W. Jones Date AROD17858