HomeMy WebLinkAboutSite Plan DetailExisting (Partial) 1r4'=1�
DEMOLITION NOTES:
1. THIS DEMOLITION PLAN SHOWS GRAPHIC AND WRITTEN INFORMATION
CONCERNING THE EXISTING SPACE. THIS IS INCLUDED AS 'INFORMATION
ONLY' REPRESENTING AVAILABLE RECORD INFORMATION OF THE ORIGINAL
LEASE DRAWINGS PLUS FIELD NOTATIONS. SOME MODIFICATIONS MAY
HAVE BEEN MADE AND NOT SHOWN. THIS INFORMATION IS FOR THE
CONTRACTORS REFERENCE AS MAY BE USEFUL.
2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND
DETERMINE THE SCOPE OF WORK REQUIRED.
3. THE CONTRACTOR SHALL EXAMINE THE EXISTING BUILDING AND WORK
SHOWN BY ALL CONTRACT DOCUMENTS TO DETERMINE THE SCOPE OF
DEMOLITION REQUIRED WHETHER SPECIFICALLY SHOWN OR NOT.
4. REFER TO MECHANICAL & ELECTRICAL DEMOLITION NOTES AND MEP
DOCUMENTS FOR EXTENT OF DEMOLITION OF THOSE SYSTEMS.
5, PROTECT ALL EXISTING STRUCTURE, SYSTEMS, FINISHES AND GENERAL
CONSTRUCTION THAT ARE TO REMAIN THROUGHOUT THE COURSE OF THE
WORK TO PREVENT DAMAGE OR LOSS.
6. CONTRACTOR IS TO VERIFY UTILITY LINE LOCATIONS AND MAINTAIN THOSE
THAT SERVE OTHER PARTS OF THE BUILDING THAT ARE NOT AFFECTED BY
THE DEMOLITION.
7. PRIOR TO INTERRUPTING OR OTHERWISE AFFECTING ANY SUCH OPERATING
SYSTEM, UTILITY OR SERVICE, CONTRACTOR SHALL CONSULT WITH
OWNERS REPRESENTATIVE TO ESTABLISH A MUTUALLY SATISFACTORY
SCHEDULE FOR CUT OVER, CUT OFF DISRUPTION OR OTHER CHANGE IN THE
OPERATION OF THE AFFECTED SYSTEM, UTILITY OR SERVICE.
8. ALL WORK WILL BE PERFORMED IN THE BEST WORKMANSHIP POSSIBLE IN
ACCORDANCE WITH THAT TRADES BEST INDUSTRY STANDARDS.
9. NOISE AND DUST IS NOT TO BE DISRUPTIVE TO THE OCCUPIED AREA OF THE
BUILDING. PROVIDE TEMPORARY PARTITIONS AS REQUIRED.
10. DEMOLITION IS TO BE DONE IN A CAREFUL AND ORDERLY MANNER 50 AS
NOT TO DAMAGE FINISHES OR EQUIPMENT TO REMAIN.
Demolition 114' = V-0'
NOTES:
1.
2.
4.
5
54' MIN.
A nwaom wvmwt+ore 12' 42°MIN.
ALL DIMENSIONS ARE ABOVE FINISHED FLOOR.
CRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/2
'. Z TOILET N
PROVIDE 1 10 CLEARANCE BETWEEN RAIL AND WALL. Z Z ��PAPER
PROVIDE GRAB BAR BACKING SUCH THAT BARS SUPPORT PULL STRENGTH OF NOT LESS THAN 250 LBS.,02FINISHES PER FBC:BUILDING CHAPTER 12 INTERIOR bENVIRONMENT `� 8• N v
A FLOORS IN BATHROOMS, KITCHEN AND PUBLIC
AREAS TO BE FINISHED WITH NON -SLIP DURABLE
NON -ABSORBENT COATING. 2 ' MIN. 1 IN.
B. PERIMETER WALLS AT BLOCK AREA 3 FT. FROM FLOOR
WILL BE COATED WITH NON -ABSORBENT FINISH,
WASHABLE IN BATHROOMS AREAS.
ADA Toilet Details
TRANSFER
SIDE
Improvements 3IB• =1'�
FASTEN METAL TRACK TO
EXISTING CEILING
D
x
u
ALUM. STUDS 19 O.C. WITH 10 j
DRYWALL EACH SIDE b
ro O
0
I
METAL TRACK WITH 3W TRACK
FAST PINS EVERY 12 O.C.
VINYL BASE (TYPJ
Typical Wall Section 3r4.=1,-0.
;00
3'
3_ZiOy U/Mr�way�
L%� �rlr+y
St. Lucie County FACILITIES
2399 Virginia Avenue
Fort Pierce, Florida 34982-5652
General Contractor:
Keyplan:
® = Area of Improvements
Issues:
No.: Date: Description:
A 12.W.2021 REVIEW
D 12.0s202, I -STING
C 12.132021 PROPOSED FENCNQ
D 01.M20M ADA FACUMS REVIEW
o1 01.x2022 PSRMrr
02 01.28.2022 PERMIT REV. 01
03 01.29.2022 PERM7REV.02
Project:
County
Animal Shelter
3404 Midway Road
Fort Pierce, Florida
Drawing Title:
ACCESSIBILITY
IMPROVEMENTS
Drawn:
PWJ
Issue Date:
0,2 ta=
Checked:
Scale:
PWJ
AS NOTED
Project No.:
Sheet No.:
A-2
VC no .
I ISig'
Q�4Y��
�D�ate-
/ 01.2a.2
Peter W. Jones Date
AR0017858
N 89'55'23E
.POUND METAL
GRATE
PIPE
C z
LOCATE PAIR 5' GATES,
FIELD VERIFY W
w I 7 STORY BLOCK NEW 6' CHAIN j
11 STORAGE UNK FENCE 0
BUILDING ENCLOSURE _
o
j I
a I
N 89' S523' E 208.1 V
Di I
a I m
NEW 6'CHAIN N
LINK FENCE
ENCLOSURE j
s i PARCEL B o
F I �
W I �
wl �I j 3
<I WI j
� ¢I e
D
o � �
p NI g
Nj ¢I Z
O
Z
N I &CHAIN UN FENCE
� I
REMOVE PORTIONS OF
EXISTING FENCING
EXISTG.
r
I I
�rD f - I .FREnSeffti� �,G `°wy
A�
ZZ�
p�W
I j ) NNCIE— _
I E gUOSURE e
Dasm m>f
Dw1wGWoo. EE1,oE NEw 4' 1-STORY BLOCK
wncro%NRxwa ENIT BUILDING
rNl ceml wl�cn GATE NEW 4'
I i pO ACCESS .4- C.O.
CPTIE-R. GATE GATEE,PUMP
I I KIELD VERIFY
I I I I
ACCESSIBLE
PARKING SPACE
I TO BE LOCATED AT
CLINIC
REN ENTRY
I I II
I I I I 4\1ETERINARY
YIC
HARD SURFACE RYY MA
PARKING
I I II
I I I I
I I II
I li I I
I I I I
I i I I
I •I I I
I I
II I EXISTING SIGN
N 89° 28' OB' W 210.00' (0)MAL
_ =t=� 111112' ACP
BOX Y,
MIDWAY ROAD R.O.W.
1
,I
EXISTG. TR.'
1
x x x x
�1
COUNTY SHELTER
ACCESS ENTRY GATE
PER FBC ACCESSIBILITY
CHAPTER 4 ACCESSIBLE
ROUTES, SECTION 404
ACCESSIBLE PARKING SPACE TO
BE LOCATED AT VETERINARY
CLINIC PRIMARY ENTRY PER FBC
ACCESSIBILITY SECTION 205
PARKING SPACES, SUB -SECTIONS
208A, 208.2, AND 208.3
6O ACCESS AISLE
43 ACCESS
x m\ x—
1 NEW 4'
ACCESS
GATE
VETERINARY CLINIC
PRIMARY ENTRY
REFERENCE FBC
ACCESSIBILITY 404.2.8
RE DOOR CLOSURES
3'-0' 3
TT
12:1 SLO PMIAX.)
E
NE
AC
LA
SE
SE
REMOVE EXISTING
CONCRETE WALKWAY
Site Plan Detail: Accessible Route REFERENCE FLORIDA BUILDING CODE -ACCESSIBILITY 7TH EOITTON 114' = 1'-0'
St. Lucie County FACILITIES
2399 Virginia Avenue
Fort Pierce, Florida 34982-5652
General Contractor.
Keyplan:
® = Area of Improvements
Issues:
No.: Date: Description:
A 12.02.2021 REVIEW
e 12...wl EXIsT o
C 12.1-1 PROPOSE. FENCWG
. 01=2022 ADA FACILE'ES
E 01.102022 SREADAREVIEW
F 01.192022 SRE REVISIONS
Ol 01242022 FERNY
w 01.2S2022 PUWIIr REV.01
Project:
County
Animal Shelter
3404 Midway Road
Fort Pierce, Florida
Drawing Title:
SITE PLAN
Drawn: Issue Date:
PWJ 01.24.2022
Checked Scale:
PWJ AS NOTED
Project No.: Sheet No.:
A-1
w� A roof
�i tiyt �PtO
gSA :e 'R00�ti22A4
�0;.
01.2a.2022
Peter W. Jones Date
AROD17858