HomeMy WebLinkAboutAluminum Screen DesignALUMINUM SCREEN DESIGN 3EXTRUDED FASCIA IS " INSULATED ROOF WITH ATTACHED
HE 10 DTO 3`" INSULATED
TED R OF ATTACHED TO GUTTER
FROM ENDS 24" O.C.
EXTRUDED GUTTER IS ATTACHED'
3" INSULATED ROOF WITH #10 1" 6"
FROM ENDS 24" O.C.
ROOF IS ATTACHED TO FRONT WALL
WITH (4) #10 4" PER PANEL
2X2 POST .046 OR GREATER
2 HINGE
2X3 FRONT WALL TOP PLAT]
HINGE LOCATIONS
SCREEN DOOR FULL Z OR
DOOR JAM STANDARD DETAIL
EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24" O
2X4 FRONT WALL
(OPTIONAL) KICK PLATE IS ATTACHED TO
STRUCTURE WITH 910 1" 6" FROM ENDS 18" O.C.
UPRIGHTS ARE ATTACHED WITH:
BLIND SCREWED WITH (3) #10 3",
CAPRI CLIPPED WITH (4) #10 1" PER CLIP
BLIND CLIPPED WITH (4) #10 1" PER CLIP
1X2 IS ATTACHED TO FRONT WALL
WITH #10 2" 6" FROM ENDS 24" O.C.
CHAIR RAIL IS ATTACHED TO UPRIGHTS
WITH EITHER:
BLIND SCREWED WITH (3) #10 3" OR,
CAPRI CLIPPED WITH (4) #10 1" PER CLIP OR
BLIND CLIPPED WITH (4) #10 1" PER CLIP
UPRIGHTS ARE ATTACHED WITH:
BLIND SCREWED WITH (3) 910 2" OR,
CAPRI CLIPPED WITH (4) #10 1" PER CLIP &
BLIND CLIPPED WITH (4) #10 1" PER CLIP
" INSULATED ROOF IS ATTACHED TO
,LUMINUM STRUCTURE WITH #10 4"
"L•UnL.f L`A711C' 7A's n 11
SIDE
1X2 IS ATTACHED TO BLOCK STRUCTURE
WITH 2-1/4" X 1/4" TAPCONS 6" FROM
ENDS 24" O.C.
2X4 SIDE WALL UPRIGHTS
2" X 2" X 1/8" ANGLE IS ATTACHED TO
UPRIGHT W/ (2) 910 1" & INTO CONCRETE
W/ 2-1/4" X 1/4" TAPCON
2X3 CHAIR RAIL
1X2 IS ATTACHED TO CONCRETE WITH:
2-1/4" X 1/4" TAPCONS OR 5" X 1/4" IF THRU PAVERS
OR #10 2" IF TO WOOD DECK 6" FROM ENDS 24" O.C,
a4 Q
ALLJMWUMSCREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON
AL S CREENDESIGN METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5 4401 VINELAND ROAD
,{ ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH SUITE A6
@ 1 v AHOO• COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2020 (7TH EDITION) ORLANDO FL 32811
FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH
PHONE: 407-734-1470
(FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1. ' .947509
FAX: 407-734-1790 CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS CA#3 093 0
�S