HomeMy WebLinkAboutPool - Spa PlansI jI I I 1 I I I I I I a I F al a I a a. I I I II I I 1 I I I I 1 L 1 I I 1 I i I NOTE: DECK AND DECK POOL/SPA BEAM JOINT WATERPROOFING SPECIFICATIONS AND DETAILS - BY OTHERS NOTE: EXISTING 48" MIN. HIGH FENCE W/ SELF LATCHING GATE THAT SWINGS OUT AWAY FROM POOL AREA VERIFY EXIST. FENCE INCOMPLIANCE W/ CHILD SAFETY BARRIER REQUIREMENTS PER FBC SEVENTH EDITION (2020) POOL/SPA HEATER UNDER STAIRS SEE SITE PLAN: BY OTHERS REINFORCED OR PRODUCT APPROVED CONCRETE SLAB(S) (FIELD VERIFY SIZE & LOCATION) � AUTO -FILL DEVICE 3/4" FRESH WATER SUPPLY LINE FROM EX. HOSE BIBB - BY OTHERS FIELD VERIFY H.B. LOC. & 2" OVERFLOW LINE TO ON -SITE DRAINAGE SYSTEM - BY OTHERS EXIST. PORCH 21� NOTE: POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO CONSTRUCTION NOTE: APPLY BASECIZETE WATER PROOFING ON ENTIRE POOL/SPA WET SURFACE PER MANUFACTURES SPECIFICATIONS PRIOR TO INSTALLATION OF ALL FINISHES RESIDENC FINISH FLOOR ELEVATION = 21.5' NAVD STEPS 240 SQ. IN. MIN. i TOP TREAD (2) LED POOL/SPA PLUMBING FLAN SCALE: 1/4"=V-0" POOL/SPA EQUIP. IN BASEMENT (GROUND LEVEL) SEE SITE PLAN: BY OTHERS 1 (4) INLETS AQUASTAR 32CDFL - 32" 1 CHANNEL DRAIN (316 GPM @ 3.9 1 FT/SEC THRU GRATE - SINGLE 1 UNBLOCKABLE COMPLIANT W/ ASME/ANSI A 112.19.8 - 2017 \ OR EQUAL xl wl Q1 n T n T I 12" LIGHTS W/ NICHE e 1 1 2.5" 1 1 8" STUB -OUT FOR SCH POOL CLEANER 40 of I " I 21.0' NAVD 1 12„ 12" 12" �I -- ---- __ [ — L 3" SCH 40 2.5" SCH 40 �2.5" SCH 40 _~ -.2"SCH 40 I 1 1 1.5" SCH 40 I L MANIFOLD J 3" SCH 40 —T J 3" SCH 40 DECK -BY L J OTHERS PERIMETER BONDING— — WIRE @ 18"MIN. - 24" MAX. FROM W.L. (SEE DETAIL) NOTE: EXIST. PROVIDE WINDOW AND DOOR ALARMS ON ALL OPENINGS THAT LEAD ONTO POOL AREA PER CODE 2.5" 1 SCH d 40 x M 10 zyu Utp $Eras `ccww.A_ 1 I1 I 1 I 1 n l'a.AISED SPA ABOVE DECK 18" BENCH - 20" BELOW W.L. (6) THERAPY JETS (1) AQUASTAR 32CDFL - 32" CHANNEL DRAIN (316 GPM @ 39 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE OR EQUAL (I) LED S?X LIGHT - NICHELESS 360 DEGREE SPILLWAY REMOTE. SPA CONTROL NOTE: THESE PLANS ARE FOR POOL AND SPA STWJCTURES, PLUMBING & EQUIPMENT/ELECTRICAL ONLY. ALL OTHER FEATURES DESIGNED BY OTHERS. 22 -Dots V%('E 0 f I sock DRAWN BY: WJC CHECKED BY: SMS DATE: 6-18-21 SCALE: AS NOTED JOB NUMBER: 21 - 295 SHEET 1 OF 3] STAIRS & i RAILING - BY OTHERS 8„ #4 DIA. REBAR @ 12" O.C.E.W. IN SPA WALL #4 DIA. REBAR @ 6" O.C.E.W. TOP MAT r 12" 41 20" 16" RAILING - BY OTHER ` , - 94 DIA. REBAR @ 12" O.C.E.W. 12" v BOTTOM MAT fE� 8" F— 8" r— 8" COPING - TYP. 121, DECK - BY OTHERS DECK AND DECK POOL/SPA BEAM JOINT WATERPROOFING SPECIFICATIONS AND DETAILS - BY OTHERS — 18" DIA. -5000 P.S.I. CONCRETE EXTENSION TYP. 14" DIA. AUGER CAST PILE - TYP. 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY SPA SECTION SCALE: 3/8" = l'-0" CONTROL LINES - FIELD VERIFY RAILING - 8" BY OTHERS COPING - TYP. DECK - BY OTHERS \ DECK AND DECK POOL/SPA BEAM JOINT WATERPROOFING SPECIFICATIONS AND DETAILS - BY OTHERS PILING NOTES: -RECESS PILING 3" INTO BOTTOM OF POOL FLOOR (TYP.) -PILE REINFORCING (NOT SHOWN) IS TO BE SPECIFIED BY PILING ENGINEER - PILING STEEL TO BE BENT INTO POOL FLOOR AND TIED TO TOP MAT OF STEEL NOTE: APPLY BASECRETE WATER PROOFING ON ENTIRE POOL/SPA WET SURFACE PER MANUFACTURES SPECIFICATIONS PRIOR TO INSTALLATION OF ALL FINISHES NOTE: DECK AND DECK POOL/SPA BEAM JOINT WATERPROOFING SPECIFICATIONS AND DETAILS - BY OTHERS 18" DIA. PILE / EXTENSION - SEE DETAIL / - 5" 3' #4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT 14" DIA. AUGER CAST PILE - TYP. 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY 23' #4 DIA. REBAR @ 6" O.C.E.W. TOP MAT I V.41' SLOPE 1' I WATERLINE I, 24" MIN. BEND INTO BOTTOM MAT - TYP. 18„ 18" DIA. - 5000 P.S.I. CONCRETE r l' EXTENSION l 3'-0" #3 DIA. HOOPS 2„ j1 II MAX. @ 16" O.C. 11- 2„ 2„ I 2' ro IN. I I EXISTING EXISTING PILE STEEL PILING TIED INTO BOTTOM 1411 MAT OF POOL FLOOR STEEL PILE EXTENSION DETAIL SCALE: 3/8" =1' 0" 12"112"1129f18f1 5" r lo" 1011 r lo" L 12„ v REBAR 12" O.C.E.W. BOTTOM MAT STEP SECTION SCALE: 3/8" = 1'-0" TERLINE 18" DIA. PILE EXTENSION - SEE DETAIL POOL SECTION TYPE "O" POOL SCALE: 3/8" = 1'-0" COPING - TYP. i DECK - BY OTHERS DECK AND DECK POOL/SPA ABEAM JOINT WATERPROOFING SPECIFICATIONS AND DETAILS - BY OTHERS #4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT 18" DIA. PILE EXTENSION - SEE DETAIL 14" DIA. AUGER CAST PILE - TYP. 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY 5' .COPING - TYP. r STUCCO FINISH - I—OTHI 4'-11" i �— #4 DIA. REBAR @ 12" O.C.E.W. .� 12" \ ` WALL - BY OTHERS 18" DIA. PILE EXTENSION - SEE DETAIL • U g V oN0 4 r� DRAWN BY: WJC CHECKED BY: SMS DATE: 6-18-21 SCALE: AS NOTED JOB NUMBER: 21 - 295 SHEET 2OF3 DECK - BY OTHERS STONE COPING 8" OR EQUAL SLOPE DECK Ye" PER FOOT ^E✓_ qa v aW+ 2-#4 DIA, a CONT. MARCITE OR EQUAL REINFOI (SEE SHE 12" 7 RADHUS VARIES TYPICAL WALL SECTION WATERLINE p I �o VACUUM FITTING W/ SELF -CLOSING SAFETY COVER (HAYWARD MODEL #400 OR EQUAL) W.L. M8 SOLID BARE COPPER BOND WIRE W/ APPE, CLAMPS (ONE ON EACH SIDE OF POOL-4TOTAL) (ENTIRE PERIMETER) 1, 14" o� �w a PIPE REDUCED TO 1" aAND RUN DECK XO e3 / 6" THICK CONCRETE SLAB (BY OTHERS) 2" SCH 40 PVC W/ (1) a8 BARE SOLID COPPER WIRE LED LIGHT SLEEVE BONDED TO POOL STEEL AS SHOWN QG STEEL SP 10-22 WALL 2 OF 3) EOUIPOTENTIAL BONDING DETAIL FITTING - OR EQUAL PER FLORIDA BUILDING CODE ADAPTATION OF INSTALLED INSIDE PIPE N.E.C. 2017 SEC. 680.26 LED LIGHT DETAIL VACUUM LINE DETAIL (WHEN APPLICABLE) rw1 POOL SYSTEM FLOW RATE: 150 GPM (MAXIMUM FLOW FROM PUMP CURVE) REC. PUMP = 2.7 HP JANDY VS -Plus HP VSPHP270 VARIABLE SPEED - LOW SPEED = 36 GPM MAX. HIGH SPEED = 150 GPM @ 50 TDH 3" SUCTION PIPE @ 150 GPM = 6.63 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" BRANCH PIPE @ 75 GPM = 5.13 FT./SEC. (6 FT./SEC. MAX. - SUCTION LINES) 3" PRESSURE PIPE @ 150 GPM = 6.63 FT./SEC.. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER = 150 GPM @ 1 GPM/ SQ. FT. EQUIPMENT LAYOUT =150 SQ. FT. MIN. FILTER AREA :fr"E.`N'I^5: LEGEND ro �:1 HEATER (GAS) - IGNAITION SWITCH 3 - #12 THHN CU WITHIN 1/2" CONDUIT (CONNECT TOP 20 AMP - 1 POLE BREAKER) CONTROL 2 POLE BRE TIME CLOC AND HEAT (3) - 46 & (1) #10 THEN CU IN 1" CONDUIT /POOL PANEL W/ 60 AMP - MANUAL MOTOR STARTER SWITCH AKER W/ INTEGRAL K FOR PUMPS, MOTOR ER GROUND RPVC S.P.S.T. TOGGLE SWITCH (2) LED POOL LIGHTS GFI NOT REQUIRED) (1) LED SPA LIGHT ( GFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH NEC 2017, SECTION 680. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3-#12 THHN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LIGHT(S). 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. W/ #8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.5. 6. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL - BY OTHERS. 7. ALL PVC CONDUITS EXPOSED TO SUNLIGHT TO BE PAINTED WITH APPROVED COATING. 2.7 HP PUMP MOTOR w/ BUILT-IN OVERLOAD SWITCH W/ 3 - #10 THHN CU WITHIN 1/2" MIN. CONDUIT (CONNECT TOP 20 AMP - 2 POLE GFCI BREAKER) 12 VOLT TRANSFORMER JUNCTION BOX ELECTRICAL DIAGRAM AQUASTAR 32CDFL - 32" CHANNEL DRAIN (316 GPM, @ 3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE OR EQUAL FINISH PLASTER HYDROSTATIC RELIEF VALVE & PERFORATED PVC COLLECTION TUBE, WHERE REQUIRED N.T.S. 32" 3 1/4" NOTE: 25.9 SQUARE INCH OPEN AREA, 316 GPM = 3.9 FEET PER SECOND HYDROSTATIC RELIEF VALVE PORT OR CAP OFF FLOOR MAIN DRAIN SUCTION LINE TIED TOGETHER AS SHOWN ABOVE - PIPE SIZE PER PLAN MIN. % YARD GRAVEL SUMP WRAPPED W/ DRAIN FEILD CLOTH (RECOMMENDED) Channel Main Drain Detail SCALE: 3/8" = V-0" f i PUMP FRAME OR FILTER TANK MOUNT OR HEATER ANCHOR POOL PUMP AND � FILTER PER MFGR'S. N.O.A. 4" THICK REINFORCED CONCRETE SLAB ��-- 2" MIN. 1. 3" SPA MAIN DRAIN LINE 2. 2" VACUUM LINE 3. 3" POOL MAIN DRAIN LINE 4. 2" SKIMMER LINE 5. 3" RETURN TO SPA THERAPY JETS 6. 3" POOL RETURN LINE A. 2.7 HP REC./THERAPY PUMP W/ APPR. HAIR & LINT STRAINER B. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE C. 1.5" TO WASTE OR DISCHARGE TO GROUND D. 400,000 BTU GAS HEATER W/ INTERNAL BY-PASS E. VALVES (TYPICAL) F. SALT GENERATOR G. INSTALL PERMA-CAST PB-2011 WATER BOND OR APPROVED EQUAL TIED TO PUMP GROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA EXPOSED TO WATER) PER MFGRIS SPECS (FIELD VERIFY LOCATION) FILTER HEATER POOL PUMP, FILTER AND HEATER ANCHOR POINTS MAY VARY POOL EQUIPMENT ANCHORING DETAIL SEE MFGR, SPECIFICATIONS FOR ADDITIONAL ANCHORING INFORMATION - EQUIPMENT SHAPES MAY VARY POOL/SPA SPECIFICATIONS POOL SIZE: 13'-0" X 28'-0" DEPTH: 3'-0" TO 4'-11" SPA SIZE: 5'-0" X 5'-0" DEPTH: 3'-0" VOLUME: 11,200 GALLONS POOL ELEVATION: TOP OF COPING = 21.0' NAVD TURN OVER RATE: 5.1 HR. na, 36 GPM MAX. - LOW SPEED (TURN OVER RATE: 1.2 HR. (a, 150 GPM - HIGH SPEED) DESIGN FLOW RATE = 11,200 GAL./6 HRS./60 MIN. = 32 G.P.M. TILE: STANDARD THERAPY JETS: (4) IN SPA POOL/SPA FINISH: MARCITE OR EQUAL PIPING: SCH. 40 INLETS: POOL (4) SPA (THRU JETS) DECK: BY OTHERS ELECTRIC: BY OTHERS POOL LIGHT: (2) JANDY LED - NICHELESS SPA LIGHT: (1) JANDY LED - NICHELESS LADDER: NO HANDRAIL: NO REC./THERAPY PUMP: 2.7 HP JANDY VS -Plus HP VSPUP270 A.P.S.P. PUMP CERT.: CURVE A - 69.2 GPM (a� 3450 RPM FILTER: JANDY CS200 CARTRIDGE - 200 SQ. FT. FILTER AREA HEATER: (1) JANDY fE 3� I APPROVED POOL COVER OR LIQUID COVER VACUUM LINE: YES POOL AREA: 362 S.F. PERIMETER 93 L.F. SPA AREA: 30 S.F. PERIMETER 22 L.F. AUTO -FILL: YES OVERFLOW: YES CHLORINE GENERATOR: JANDY AQUAPURE PiIOL/SPA CONTROL SYSTEM: JANDY I AQUALINK GENERAL NOTES: 1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE GROUNDED PER CODE. 2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 P.S.I. AT 28 DAYS. 3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, STEEL SHALL BE BENT, MIN. 40 DIA. LAP SPLICE AND PLACED IN ACCORDANCE WITH ACT STANDARDS. PROVIDE 3" MIN. CONCRETE COVER OVER REINFORCING STEEL.. 4. GRATE IN MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF THE SUCTION LINE. 5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER. 6. POOL TO BE FENCED PER LOCAL CODES. 7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE. 8. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE CURRENT REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI/ NSPI 5; ANSI/ NSPI 6; AND ANSI/APSP 7 AND ANSI/APSP.ICC-15. 9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT. 10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH THE FBC SEVENTH EDITION (2020) - RESIDENTIAL -PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY. 11.. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC SEVENTH EDITION (2020) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL. 12. SHOULD ANY MUCK, MARL, OR OTHER ORGANIC SOILS BE DISCOVERED ON EXCAVATION, THEY SHOULD BE REMOVED IN THEIR ENTIRETY, ALL CONSTRUCTION SHALL STOP AND THE ENGINEER OF RECORD SHALL BE CONTACTED TO CONDUCT AN INSPECTION. 13. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. (CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR) 14. POOL PLANS ARE DESIGNED TO MEET THE FBC SEVENTH EDITION (2020) - RESIDENTIAL - PRIVATE SWIMMING POOLS. 15. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP 7-2006 AND FBC SEVENTH EDITION (2020) - RESIDENTIAL CHAPTER 45. 16. GROUND WATER MUST BE LOWERED TO BOTTOM OF DEEP END PRIOR TO EMPTYING POOL TO AVOID UPLIFTING (POPPING) OF POOL. PLUMBING NOTES: 1. ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE FBC SEVENTH EDITION (2020), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS. 2. POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES AND 10 FT/SEC. PRESSURE LINES. 3. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A SUITABLE COVER. ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL. 4. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR VERTICAL CHECK PATTERN. 5. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE MEANS OF RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. 6. ALT, POOL PIPING SHALL BE 1.5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL OF APPROVAL. 7. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES WHEN EMPTY, FOR WATER TABLE UP TO 3'-0" BELOW POOL/SPA DECK ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE ELEVATIONS, ALL POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF VALVE. 8. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL. 9. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACK FLOW PROTECTION. NO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER A DIVING BOARD, OR PROPERLY GUARDED. 10. ALL POOL/SPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC WATER TEST OF NOT LESS THAN 50 PSI FOR 15 MINUTES. 11. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FBC, SEVENTH EDITION (20211), PLTISVI'MG REQUIREMENT'S. 12. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR UNION CONNECTION ADJACENT TO THE HEATER. 13. PURPLE PRIMER CONFORMING TO ASTM F656 REQUIRED ON ALL PVC PIPING PER FBC SEVENTH EDITION (2020) PLUMBING 605.21.3. 14. GAS PIPING SHALL COMPLY WITH FBC, SEVENTH EDITION (2020), FUEL GAS. (SEPARATE PLANS AND PERMIT REQUIRED) 15. SWIMMING POOL/SPA WATER HEATERS SHALL BEAR THE LABEL OF A RECOGNIZED TESTING AGENCY. 16. PROVIDE BACK FLOW PREVENTOR ON WATER SUPPLY - BY OTHERS. L= �1 N♦� N \ \ FD. P/K N&D D-• LB 959 N: 1084375.28 \\ E: 908009.38 25,20' 35. FI). 5/8" IRC PSM 4973 26.52"\ \ S1j\ \. ^� \\ X ,\1 3;U^' FD. 5/8" IRC LB 959 d: 1084300.26 _.4a E: 908039.15 N 9QJN W ; \X"IN ^I/ ggoX N\ Xg¢y 1 SITE BENCHMARK 2�-v, \ FD. 5/8" IRC !4,1"+ CNX r. PSM 4973 ' X 15x N.- ri -198& C L ' v SET PI &U v�--------- - - >, HSBS t 05 N 1084,{ 33 o+"• - X�2FFLO H 20 E10PGK \ Nb N S \ I m 11� \\ x'k1b oo tit 5Ge Xg�g\� `ic``♦ T�1I -�. V, \� ♦A ''��jjLL��CC i V ♦v pay N;GMEN \ \ _ uliL ` a I F ♦ ♦ti 5 \\ \ X \'a sv FD. 5/81\ \�, '1988 CCCL ysG IRC \ a^. -SET P &D s N0 ID S LS 6905 �w \ N: 1084225.33 '\ E: 908096.60 �0 LOT 30 DIAMOND SANDS PLAT NO. 2 (PH 54, PG. 40) '1/ACAHT EQUIPMENT CONCRETE PAD ABOVE FLOOD ELEVATION 88'-0" STRUCTURE I. 6 I- R g� ,fig II I I I I N N, SEAS014AL HIGH WA 7ER LINE \\ \ EL. -5 20' (NAND) \\ LOCATED 11104120 ♦ \ v v a C) '0 0 ♦i,,O v \ ..�............. NN y d C�° O d? O o O A� ......'.".'.'.'.'.'. y \ .......... Y \ a\, \ bA O\OHO\O ...`�A.... .CAt'si-.'ot:.:...'. ♦ \\ \\ ..........)CI O0 O,, ." 0C1.. 1........ _ \ $\C $ D C�d O < .'''''"'''' ............... \ gg \� \ "K O O ° `` AA ......... \` 1 1C4'�C.J�. hF•f)Yy!',DU,;;[�.,_. .. o, \°cv O°°°o°,o S�AcyARO'uaar KJ O O O'•- O 1 \ 01 ✓F CE TA TION O O d ♦.............. g (h'�pO�Odpq�O a'b Ai e �%' Q' O 0 Z -42 d �1 xe°�\ x51 �, X61A 1'Lb a O.� O 0- d O._-_.Q_ `/ Al\\..:_:.:_.... Ko 1♦S \ 1 xi _ L� O 0 O 1tA.;... A. -. i TWO STORY +GARAGE EQUIPMENT CONCRETE SINGLE FAMILY HOUSE PA,D UNDER POOL ABOVE FLOOD ELEVATION CBS STRUCT. GARAGE (+7.0' NAVD) i H LOWER LEVEL(+9.0' NAVD) m MAIN LEVEL (+21.5' NAVD) o UPPER LEVEL (+35.5' NAVD) COASTAL CONSTRUC77ON CONTROL LINE (PB 26 P0" 2F 251> RECORDED 0911511988 PUBLIC RECORDS OF FLJ P aN •�PSE�,E \ ♦ ST LUCIE COUNTY, FLORIDA 1�)78 COASTAL CONSTRUCTION CONTRNI. LINE (SEE CCCL DETAIL) (PS 19, PG. 8A-8G) RECORDED 1211211978 PUBLIC RECORDS OF ST. LUCIE COUNT)', FLORIDA (SEE CCCL DETAIL) MIN- WTSACK i XgA XoN X't S4 MHWL LINE TABLE LINE LENGTH BEARING L13 23.96' N30"02'14"W L14 24.64' N26'46'08"W L15 23.53' N19'12'18'1N L16 10.96' N24'01'40"W EL.=0. 00' (VA bD) LOCATED 11104120 MEAN HIGH WATER 111VE EL. =0.51- (NAVD) LOCATED 11104120 III ® O OVERALL �lTE PLAN FILE �0P P REVISIONS BY 1 DATE a N / 61ML • 01.25.21 /T Q OWNER REVISIONS K.M.R. 02.15.21 co N Q OWNER REVISIONS ......- CML 102,23.21 N ^ Q DEP SET _ CML 03.02.21 0 N rn OW 3 c� W ¢I �/ V/ m O J C N c ( L I L) U w D_ 0 W iL ( 1 o z o z O Wowm I ^ � O cry U i o 14 W 0 P CID r'1 I-1 w in w t5 f T1 L O I I U Job No.20110080D Z <<`OF FLOi,( s RANDALL E ' F,OF T w Fos l�+ R0011105 ..• FL-0011105 FIRM-AA003379 ALL IDEAS, DESIGNS. ARNANGEMENIS, & PLANS INDICATED GR REPRESENTED BYTHIS DRAWING ARE OWNED BY, S THE PROPERTY OF THIS OFFICE. &WERE CREATED, EVOLVED, B DEVELOPED FOR USE ON, & IN CONNEOTIaN VATH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANPLANSGEMENTS. OR PS GRAM BE USED BY, OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER MHOUT THE 4 RITTEN PERMISSION OF RANDALL E. STOFFT. ARCHITECTS, PA. WRITTEN DIMENSIONS ON THESE DRAMSIS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY & BE RESPONSIBLE FOR ALL DIMENSIONS L CONDITIONS ON THE JOB ,& THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND D IONS GHD CONDITIONS BYTHESE ORAVANGS. SHOP DETAILS OF ADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING MATH FABRICATION ON ITEMS SO NOTED. 0201 S. ALL RIGHTS RESERVED RANDALL STOFFT ARCHITECTS PA. 101 P-1 Cl U C� V J � Vr�\1 •. U " a