Loading...
HomeMy WebLinkAboutProduct Approval Windows Horizontal Slider.1/18/22, 11:32 AM Florida Building Code Online ProfesgionalRegulationrr I BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search Or* Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL16477-R6 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived 0 Product Manufacturer Shwinco Architectural Products, LLC Address/Phone/Email 171 Jet Services Way Dothan, AL 36303 (334) 556-1000 engineering@shwinco.com Authorized Signature Keith Schneider engineering@shwinco.com Technical Representative Josh Lowe Address/Phone/Email 171 Jet Services Way Dothan, AL 36303 (334)556-1000 engineering@shwinco.com Quality Assurance Representative Josh Lowe Address/Phone/Email 171 Jet Services Way Dothan, AL 36303 (334)556-1000 engineering@shwinco.com Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E1886 2013 ASTM E1996 2014 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvXaHHDwAAyb8wC%2brihiATg4QflXXGTnHBrY%2feDRU6MxQ%3d%3d 1/3 1/18/22, 11:32 AM Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option A 07/22/2021 07/26/2021 07/27/2021 FL # Model, Number or Name Description 16477.1 1. Series 9050 OX Impact Rated Vinyl Horizontal Sliding Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL16477 R6 C CAC NI009499.02-R3.pdf Approved for use outside HVHZ: Yes FL16477 R6 C CAC NI009499.03-R3.pddf Impact Resistant: Yes FL16477 R6 C CAC NI009499-R4.pdf Design Pressure: N/A Quality Assurance Contract Expiration Date Other: 9050 OX 76x74 DP55, 54x60 DP70, 72x48 DP120 FOR 04/30/2024 DESIGN PRESSURE RATINGS REFER TO APPROVAL DRAWING. Installation Instructions GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF FL16477 R6 II 08-03556.pdf THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE Verified By: Luis Roberto Lomas 62514 FOR EASTMAN INTERLAYERS. FRAME MATERIAL TO BE RIGID Created by Independent Third Party: Yes PVC FROM VISION AAMA CERTIFIED (VEX-1). Evaluation Reports FL16477 R6 AE 514637.pdf Created by Independent Third Party: Yes 16477.2 2. SERIES 9050 XOX SERIES 9050 VINYL SLIDING WINDOW XOX IMPACT Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL16477 R6 C CAC NI012101.01-RS.Rdf Approved for use outside HVHZ: Yes FL16477 R6 C CAC NI012101.02-R2.pdd Impact Resistant: Yes FL16477 R6 C CAC NI012101-R4.pd Design Pressure: N/A Quality Assurance Contract Expiration Date Other: 9050 XOX 112x64, DP50, DP95/-130, DP130 FOR 06/30/2024 DESIGN PRESSURE RATINGS REFER TO APPROVAL DRAWING. Installation Instructions GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF FL16477 R6 II 08-03158.pdf THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE Verified By: Luis Roberto Lomas 62514 FOR EASTMAN INTERLAYERS. FRAME MATERIAL TO BE RIGID Created by Independent Third Party: Yes PVC FROM VISION AAMA CERTIFIED (VEX-1). Evaluation Reports FL16477 R6 AE 513240A.pddf Created by Independent Third Party: Yes 16477.3 3. SERIES 9050 XOX SERIES 9050 VINYL HORIZONTAL SLIDING WINDOW XOX IMPACT Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL16477 R6 C CAC NI015222.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 02/28/2025 Design Pressure: +60/-60 Installation Instructions Other: GLASS INTERLAYER COMPLIES WITH THE FL16477 R6 II 08-03701.pdf REQUIREMENTS OF THE FLORIDA BUILDING CODE Verified By: Luis Roberto Lomas 62514 ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS. Created by Independent Third Party: Yes FRAME MATERIAL TO BE RIGID PVC FROM VISION AAMA Evaluation Reports CERTIFIED (VEX-1). FL16477 R6 AE 514839.pdf Created by Independent Third Party: Yes 16477.4 4. Security Series 6050 Vinyl Security Series 6050 Vinyl Horizontal Sliding Window 74"x63" Horizontal Sliding Window Non -Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL16477 R6 C CAC NI015279.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/30/2025 Design Pressure: +60/-60 Installation Instructions Other: FL16477 R6 II 08-03741.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL16477 R6 AE 514891.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 https://floddabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvXaHHDwAAyb8wC°/a2brlhiATg4QflXXGTnHBrY%2feDRU6MxQ%3d%3d 2/3 1/18/22, 11:32 AM Florida Building Code Online The State of Florida Is an AA/EEO employer. Capy�ght 2007-2013 State of Florida.:: P vacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® 11-07 eClreck 12 Credit Card Safe https://floddabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvXaHHDwAAyb8wC%2brihiATg4QflXXGTnHBrY%2feDRU6MxQ%3d%3d 3/3 1/18/22, 11:32 AM Florida Building Code Online Professional Re1 , 1 f BCIS Home I Log In I User Registration I Hot Topics I . Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search I uuu��� ■ sj Product Approval Florida Ir USER: Public User Product Approval Menu > Product or Application Search > Application List Search Criteria Refine Search Code Version 2020 FL# 16477.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Recultc - onolicatinnc FL# Type Manufacturer Validated By Status FL16477- Revision Shwinco Architectural Products, LLC FL#: FL16477.1 National Accreditation & Management Institute Approved R6 History Model: 1. Series 9050 OX (804) 684-5124 Description: Impact Rated Vinyl Horizontal Sliding Window Category: Windows Subcategory: Horizontal Slider -Approvea Dy ut$PR. Approvals Dy LAWK snau De reviewea ana ratlnea oy me Puc ana/or the commission Ir necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. go right 2007-2013 State of Florida.:: Privacy Statement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® F091 eChecY, Credit Card Safe hftps://fioridabuilding.org/pr/prl_appjst.aspx 1/1 NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND UNIT FRAME INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 17 FOR GLASS DETAILS. FOR UNITS INSTALLED 3OFT OR MORE ABOVE GROUND LEVEL GLAZING B MUST BE USED. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING USE ROOFING NAIL WITH SUFFICIENT LENGTH TO ACHIEVE A 2" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. I TABLE OF CONTENTS SHEET NO. 1 DESCRIPTION 1 I NOTES 2 - 4 I ELEVATIONS 5 - 16 INSTALLATION DETAILS 17 (COMPONENTS REVISIONS REV DESCRIPTION DATE APPROVED 15. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 19. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 20. ALL FASTENERS TO BE CORROSION RESISTANT. 21. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2.000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .125" THICK MINIMUM SIGNED: 0511712021 SHWINCO ARCHjEEC PwODUCTS, LLC IiLo171 ERRICEsAL `It �9 DOTHAN, AL 36303 ` r••��GEMSF •'{+-�� _ *• 0,,6�5 k SERIES 9050 HS WINDOW IMPACT HVHZ NOTES ��0 , TATEOF t��\� , z %�►S;'c�0RI G DRAWN: DWO N0. REV 8 6 s101 II 1110?�\`` Luis R. Lomas P.E. FL No.: 62514 SCALE NTS — 05/04/2020 ' 1 OF 17 L ROBERTO LOADS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-66U609 Nomas@tdomaspe.com FR HE I 0��0 o o Q �p �n'❑l o ❑� HORIZONTAL CROSS SECTION FOR REFERENCE ONLY, SEE SHEETS 5 - 16 FOR INSTALLATION DETAILS 76" FRAME WIDTH 76 3" iAX � �-�}- 11 1/2" MAX O.C. � 3" MAX 3" MAX � �----{- 3 MAX 11 1/2" MAX O.C. 4.. %M E GHT O V a 3" MAX SERIES 9050 HS WINDOW EXTERIOR VIEW FRAME INSTALLATION i FR HE 3 MAX 8" MAX O.C. 4.. 1M E O GHT / MAX 3" DESIGN PRESSURE RATING IMPACT RATING ±55.OPSF LARGEANDSMALL MISSILE IMPACT MISSILE LEVEL D, WIND ZONE 4, AND HVHZ SERIES 9050 HS WINDOW EXTERIOR VIEW FIN INSTALLATION REVISIONS REV DESCRIPTION DATE I APPROVED AX NOTES: 1. SASH SIZE: 351/2"X 69 318" 2. D.L.0.:3313/16"X673/8" FIN ANCHORS MAY BE ROOFING NAILS OR #10 SCREWS SHWINCO ARCHITECTURAL PRODUCTS, LLC 171 JET SERVICES WAY DOTHAN, AL 36303 SERIES 9050 HS WINDOW IMPACT HVHZ 76" x 74" ELEVATION DRAWN: DWG NO. RE R,L. OS-03556 SCALE NTS DATE 05/04/2020 s"EE 2 OF 17 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasC7alrlomaspe.com SIGNED: 0511712021 �v•���ENSF .�''`� 00 5 T`ATE OF ;PA, �ORVD . • IN �/sjs�ONA 0`�� Luis R. Lomas P.E. FL No.: 62514 E FR HE 54" FRAME WIDTH 3" MAX 11 MAX 10 C'. 3" MAX 3 MAX 11 1/2" MAX O.C. � O V /� W WE GHT 3" MAX 1 SERIES 9050 HS WINDOW EXTERIOR VIEW FRAME INSTALLATION E FIR HE 3" MAX I 3 MAX 8" MAX O.C. G., WE GHT 3" MAX SERIES 9050 HS WINDOW EXTERIOR VIEW FIN INSTALLATION DESIGN PRESSURE RATING IMPACT RATING +70.OPSF LARGEAND SMALL MISSILE IMPACT MISSILE LEVEL D, WIND ZONE 4, AND HVHZ AX FIN ANCHORS MUST BE #10 SCREWS REVISIONS DESCRIPTION DATE I APPROVED NOTES: I. SASH SIZE 271/8"X 56 112" 2. D.L.0.:23"X533/8" SIGNED: 0511712021 SHWINCO ARCHEECERRcEPODUCTS, LLC j Rli101/171 sw AY DOTHAN, AL 36303 •.%GEAt •S-�i ; *• 0„61?5 SERIES 9050 HS WINDOW IMPACT HVHZ� 54" X 60" ELEVATION TAT OF , [�� %�'��'cC • �� DRAWN: DWG NO. REV �sjONAL1E�� Luis R. Lomas P.E. FL No.: 62514 scALE NTS DATE 05/04/20205 s0EEr36 OF 17 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 d/omas@lrlomaspe.wm 4 FR HE i 72" FRAME WIDTH 3" MAX I—-r--{ 8" MAX O.C. �{ 3" MAX 3 MAX g„ MAX �ME O.C. O x GHT 3 MAX SERIES 9050 HS WINDOW EXTERIOR VIEW FRAME INSTALLATION 4 FR HE 3" MAX 1 3 MAX 8" MAX O.C. B" T- 1ME GHT 3" A DESIGN PRESSURE RATING IMPACT RATING ±120.OPSF LARGE AND SMALL MISSILE IMPACT MISSILE LEVEL D, WIND ZONE 4, AND HVHZ REVISIONS I REV I DESCRIPTION I DATE I APPROVED kX NOTES., 1. SASH SIZE: 36 1/4"X 44 112" 2. D.L.O.: 32"X 413/8" FIN ANCHORS MUST BE #10 SCREWS SERIES 9050 HS WINDOW EXTERIOR VIEW FIN INSTALLATION SHWINCO ARCHITECTURAL PRODUCTS, LLC 171 JET SERVICES WAY DOTHAN, AL 36303 SERIES 9050 HS WINDOW IMPACT HVHZ 72" X 48" ELEVATION DRAWN: DWG N0. REV R.L. 08-03555 — ScaLE NTS I DATE 05/04/2020 1 SHEET4 OF 17 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NG 27023 434-688-0609 r1lamas@146maspe.cbm SIGNED: 0511712021 1R! I O,y41i/. ��� •v�O II NSF AT OF • �� i0 i P•: '�'F•';ZOR10. Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS APPROVED SEALANT BEHIND FLANGE APPROVED SEALANT BEHIND FLANGE WOOD FRAMING OR 2X BUCK BY OTHERS INTERIOR EXTERIOR 1/2" MIN. EDGE DISTANCE 1 1/4" MIN. EMBEDMENT 1/4"' MAX. SHIM SPACE #10 WOOD SCREW #10 WOOD SCREW - SILL TO BE SET IN A BED OF APPROVED SEALANT RMSIONS ' REV DESCRIPTION DATE I APPROVED 1 1/4" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE 1 1/2" MIN. EDGE QOd� DISTANCE I —II INTERIOR #10 WOOD J uu�u SCREW WOOD FRAMING �❑ OR 2X BUCK BY OTHERS EXTERIOR APPROVED 9 SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 1/4" MAX. NOTES: SHIM SPACE 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 1 1 /4" MIN 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY EMBEDMENT AND MUST BE DONE PER FMA/AAMAANDMA STANDARDS. 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION SHWINCO ARCHITECTURAL PRODUCTS, LLC 171 JET SERVICES WAY DOTHAN, AL 36303 SERIES 9050 HS WINDOW IMPACT HVHZ FLANGE INSTALLATION DETAILS DRAWN: DWG NO. RI R.L. 08-03555 SCALE NTS JDATE 05/04/2020 ISHEET5 OF 17 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-66"609 rilomas@irlomaspo.com SIGNED. 0511712021 \-N�JR 11L C,/,�� �;••�,\G ENSF9d' *• 0 51 ••*= TATw Luis R. Lamas P.E. FL No.: 62514 REVISIONS OESCRIPNON DATE I APPROVED 1/2" MIN. METAL EDGE DISTANCE STRUCTURE BY OTHERS 1/4" MAX. SHIM SPACE APPROVED SEALANT BEHIND FLANGE 1/4" MAX. 1/2" MIN. SHIM SPACE EDGE QO�� DISTANCE 0 INTERIOR APPROVED SEALANT BEHIND FLANGE METAL STRUCTURE BY OTHERS INTERIOR #10 SMS OR SELF DRILLING SCREW �10 SMS OR SELF DRILLING SCREW SILL TO BE SET N A BED OF 4PPROVED SEALANT 1 /4" MAX. SHIM SPACE 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION #10 SMS OR SELF DRILLING uu SCREW �❑ METAL STRUCTURE BY OTHERS EXTERIOR APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY AND MUST BE DONE PER FMA/AAMAIINDMA STANDARDS. SIGNED: 0511712021 SHWINCO ARCHITECTURALPWODUCTS, LLC R ��L/0 )// 171 ````J\S DOTHAN, AL 36303 ` v•��6ENS.� *• Os,6126 *- SERIES 9050 HS WINDOW IMPACT HVHZ Ir)` FLANGE INSTALLATION DETAILS �� • TAT OF rii0�t`s FCpRIDP G���� DRAWN: DWG NO. REV //S'ONIAl11��\`\` Luis R. Lomas P.E. FL NO.: 62514 SCALE NTS DATE 05/04/20206 SHEET6-035?6 OF 17 L ROBERTO LOMAS P.E. 1432 WOODFORD ROLEWISVILLE NC27023 43468E-0609 dlomas@lAomaspe.wm 2" MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS °e a ° :' 1 1/4" e '°. . ' MIN. °' EMBEDMENT APPROVED -� SEALANT BEHIND FLANGE OOL- ❑0 1/4" MAX. rI SHIM SPACE INTERIOR EXTERIOR 3/16" TAPCON II 3/16" TAPCON lul SILL TO BE SET IN A BED OF APPROVED SEALANT a APPROVED SEALANT 1/4" MAX. BEHIND FLANGE c= SHIM SPACE CONCRETE/MASONRY BY OTHERS I 1 1/4„ ° MIN a EMBEDMENT °_. 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION CONCRET&MASONRY INSTALLATION REVISIONS DESCRIPTION DATE I APPROVED 1 1/4" MIN. EMBEDMENT • 9 c 1/4- MAX. SHIM SPACE e< 2" MIN. EDGE DISTANCE ' INTERIOR 3/16" TAPCON a❑bQ CONCRETE/MASONRY a • • �❑ BY OTHERS EXTERIOR APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BYOTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY AND MUST BE DONE PER FMA/AAMAANDMA STANDARDS. SIGNED: 0511712021 SHWINCO ARCHITECTURAL URAL PRODUCTS, LLC171 JET VICES WAY 0�/i,��� DOTHAN. AL 36303 ` v•��CENS+�•9�+-�= Oy6126 *� SERIES 9050 HS WINDOW*• IMPACT HVHZ =,q� FLANGE INSTALLATION DETAILS z.10 • TAT OF %�'cFs'PCpR10Q: DRAWN: DWG NO. REV OB 56 SCALE DATE SHEET NTS 05/04/2020 7 OF 17 Luis R. Lomas P.E. FL No.: 62514 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC27023 434-688-0609 Hlomas@Irlamaspe.mm ' REVISIONS DESCRIPTION DATE I APPROVED 1/2" MIN. WOOD FRAMING r EDGE DISTANCE OR 2X BUCK I 1 1/4" MIN. 1/4" MAX. BY OTHERS EMBEDMENT SHIM SPACE APPROVED 1 1/4" MIN. I SEALANT EMBEDMENT 1/2 MIN. BEHIND FLANGE EDGE DISTANCE d❑❑❑ 1/4" MAX. ❑❑ SHIM SPACE Q 4 #10 WOOD SCREW #10 WOOD SCREW a INTERIOR INSTALLATION CLIP INSTALLATION CLIP INTERIOR EXTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT J� U #10 WOOD SCREW APPROVED SEALANT INSTALLATION CLIP BEHIND FLANGE �aq❑❑❑ 1/4" MAX. SHIM SPACE WOOD FRAMING OR 2X BUCK 1 1/4" MIN BY OTHERS EMBEDMENT 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION WOOD FRAMING UL-� OR 2X BUCK BY OTHERS EXTERIOR APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY AND MUST BE DONE PER FMA/AAMANVDMA STANDARDS. SIGNED: 0511712021 LLC SHWINCO ARCH171 �R I�:L0 4ez jEEC ERR cEsPWODUCTS, AY \\\\J\5 DOTHAN, AL 36303 \ v•v�C�NSF,cP *• 6�51 Oy SERIES 9050 HS WINDOW IMPACT � (A CLIP INSTALLATION ION DETAILS �gf • TAT OF: k ��'cF•'c(ORiQP• \��\ DRAWN: DWG NO, REV R.. 08 03E556 Luis R. Lomas P.E. FL No.: 62514 LNTS DATE 05/04/2020 8 OF 17 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWIS VILLE, NC27023 434-W8-0609 dlomasOalrlamaspa.cam METAL STRUCTURE BY OTHERS APPROVED SEALANT BEHIND FLANGE APPROVED SEALANT BEHIND FLANGE METAL STRUCTURE BY OTHERS EXTERIOR 1/2" MIN. GE DISTANCE a 1 /4" MAX. ;HIM SPACE #10 SMS OR SELF DRILLING SCREW INSTALLATION CLIP SILL TO BE SET IN A BED OF APPROVED SEALANT #10 SMS OR SELF DRILLING SCREW INSTALLATION CLIP 1 /4" MAX. SHIM SPACE 1 /2" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION REVISIONS DESCRIPTION DATE I APPROVED J 1/4" MAX. SHIM SPACE 1/2 MI"' N. EDGE STANCE #10 SMS OR J SELF DRILLING r13 INTERIOR SCREW INSTALLATION CLIP METAL J I I ULJP STRUCTURE BY OTHERS EXTERIOR APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY AND MUST BE DONE PER FMAIAAMAIWDMA STANDARDS. SIGNED: 0511712021 SHWINCO ARCHITECTURAL PODUCTS, LLC ►�I 171 WA RL0SERVICES 9��� ` 5- DOTHAN, AL 36303 •\CENSF •cf+-'� 0„&125 *� SERIES 9050 HS WINDOW*• IMPACT CLIP INSTALLATIONION DETAILS � erg! • TAT OF c �'F•'c[OR1�?'• ���i/sjsj�NAL1EaG\�\ DRAWN: DWG N0. REV R.L. 6 6 LUIS R. Lomas P.E. FL No.: 62514 � NTS DATE 05/04/2020 s03ET 9 OF 17 L. ROBERTO LOMAS RE 1432 WOODFORD RD LEWISVILLE, NC 27023 434-6W-O609 Nlomas@l)lomaspe.com CONCRETE/MASONRY BY OTHERS APPROVED SEALANT BEHIND FLANGE EXTERIOR APPROVED SEALANT BEHIND FLANGE .4 INTERIOR CONCRETE/MASONRY BY OTHERS h� d da •d a d 2" MIN. EDGE DISTANCE 1 1 /4" MIN. d' EMBEDMENT — S I 1 /4" MAX. SHIM SPACE 3/16" TAPCON INSTALLATION CLIP SILL TO BE SET IN A BED OF APPROVED SEALANT 3/16" TAPCON INSTALLATION CLIP 1 /4" MAX. SHIM SPACE 1 1/4" ,. MIN EMBEDMENT 2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION REVISIONS I REV DESCRIPTION DATE I APPROVED 1 1/4° MIN. EMBEDMENT .y .. 2„ 1/4" MAX. MIN. SHIM SPACE EDGE DISTANCE e o 3/16" TAPCON ° Q INTERIOR INSTALLATION CLIP o:a CONCRETE/MASONRY o�. • �❑ BY OTHERS EXTERIOR APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL OR 2X BUCK INSTALLATION WOOD FRAMING NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY AND MUST BE DONE PER FMA/AAA"DMA STANDARDS. SHWINCO ARCHITECTURAL PRODUCTS, LLC 171 JET SERVICES WAY DOTHAN, AL 36303 SERIES 9050 HS WINDOW IMPACT HVHZ CLIP INSTALLATION DETAILS DRAWN: DWG NO. RI R, L. 00-03550 SCALE NTS °ATE 05/04/2020 1 SRC 10 OF 17 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-666-0609 rllomasPhlomaspe.com SIGNED: 0511712021 �.A1 OF •hr �4�FS �ORID %" ONA 11\��� Luis R. Lomas P.E. FL No.: 62514 1 /2" MIN. WOOD FRAMING EDGE DISTANCE OR 2X BUCK BY OTHERS BACKER ROD 1 1/4" MIN. & APPROVED EMBEDMENT SEALANT �0 �0 1/4" MAX. SHIM SPACE INTERIOR EXTERIOR #10 WOOD SCREW #10 WOOD SCREW - SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD riv & APPROVED ❑❑ 1/4" MAX. SEALANT Ell ❑0 SHIM SPACE WOOD FRAMING OR 2X BUCK 1 1/4" MIN BY OTHERS EMBEDMENT 1 /2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION REVISIONS DESCRIPTION DATE I APPROVED 1 1/4" MIN. EMBEDMENT 1/4" MAX. SHIM SPACE 1 1/2" MIN.EDGE ado DISTANCE INTERIOR #10 WOOD J ul II Imo - SCREW �Em WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION NOTES; 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BYOTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY AND MUST BE DONE PER FMA/AAMAIWDMA STANDARDS. SIGNED: 0511712021 SHWINCO ARCHITECTURAL PODUCTS, LLC 1110171 sW AY P.- ENB� DOTHAN, AL 36303 *�•�j V0 51 *� SERIES 9050 HS WINDOW IMPACT BOX INSTALLATIONION DETAILS �y0 •• $TAT OF %�'��►s F(QRIOP CO\�•�� DRAWN: Dws NO. REV R.L. •ALE oS—D SS6 — I, NAL1����`` DATE NTS 05/04/2020 ll OF 17 Luis R. Lomas P.E. FL No.: 62514 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 rllomascalAomaspe.cam METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT METAL STRUCTURE BY OTHERS 1/2" MIN. cnnr ncTAmrc 1 /4" MAX. SHIM SPACE #10 SMS OR SELF DRILLING SCREW V10 SMS OR SELF DRILLING SCREW 31LL TO BE SET N A BED OF 4PPROVED SEALANT 1 /4" MAX. SHIM SPACE 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION REVISIONS I RW I OESCMFnCN I DATE I APPROVED I r 1 /4" MAX. SHIM SPACE T- 1/2" MIN. EDGE DISTANC I #10 SMS OR SELF DRILLING SCREW METAL STRUCTURE BY OTHERS BACK . & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2, PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY AND MUST BE DONE PER FMAIAAMAANDMA STANDARDS. 7R SHWINCO ARCHITECTURAL PRODUCTS, LLC 171 JET SERVICES WAY DOTHAN, AL 36303 SERIES 9050 HS WINDOW IMPACT HVHZ BOX INSTALLATION DETAILS DRAWN: DWG NO. REV R,L. 08-03556 — 8re" NTS DAB 05/04/2020 ISHELT12 OF 17 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVA.LE. NC 27023 434-688-0609 rllomas@Glomaspe.com SIGNED: 0511712021 o r••��C E Ns�'9cP TATE OF •�� '�Illllllm' Luis R. Lomas P.E. FL No.: 62514 2" MIN. EDGE DISTANCE CONCRETE/MASONRY <° ° . ' °° ° BY OTHERS ° ° ° ;' 1 1/4" "°. MIN. °' • EMBEDMENT BACKER ROD & APPROVED I SEALANT ��d ❑ = 1/4" MAX. SHIM SPACE INTERIOR EXTERIOR 3/16" TAPCON 3/16" TAPCON - SILL TO BE SET IN A BED OF APPROVED SEALANT REVISIONS I REV I DESCRIPTION I DATE I APPROVED 1 1/4" MIN. EMBEDMENT • ° 1 MAX. SHIM SPACE 2" MIN. E4ANCE DISINTERIOR 3/16" TAPCO.a .❑�� a . �❑ CONCRETE/MASONRY BY OTHERS EXTERIOR BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION BACKER ROD & APPROVED FT 1/4" MAX. NOTES: SEALANT ❑ SHIM SPACE 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. all!2 PERIMETER AND JOINT SEALANTBY OTHERSCONCRETE/MASONRY BY OTHERS DESIGNED INACCORDANCEWITy STME2 120BE 3. WATER PROOFING IS INSTALLERS RESPONSIBILITY ° • AND MUST BE DONE PER FMA/AAMAANDMA ° MIN STANDARDS. °e a ° a EMBEDMENT SIGNED: 0511712021 ° °' . SHWINCO ARCHITECTURAL PRODUCTS, LLC �+++1111 !IIIii� 171 JET SERVICES WAY `\\�\5 R• Lp////� 2" MIN DOTHAN, AL 36303 •�' F EDGE DISTANCE VERTICAL CROSS SECTION SERIES 9050 HS WINDOW _ *• 0 963X yt CONCRETEMASONRYINSTALLATION IMPACT HVHZ BOX INSTALLATION DETAILS =,o , TAT OF 111 DRAWN: DWG NO. REV ��'PF•:cCOR10P• �•��� KALE DATE o8—s��3T556 — //i�/S/ONALI��G\\�\ NTS 05/04/2020 13 OF 17 L. ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 FL No.: 62514 434-66&0609 Niomas@lrlom pe.mm APPROVED SEALANT BEHIND FIN ROOFING NAIL 7/16" MIN EDGE DISTANCE WOOD FRAMING BY OTHERS '4" MAX. M SPACE WOOD FRAMING BY OTHERS ROOFING NAIL 1/4" MAX r SHIM SPACE REVISIONS I REV I DESCRIPDON I GATE I APPROVED 2" LJ INTERIOR III U MIN. EMBEDMENT EXTERIOR INTERIOR APPROVED HF1 SEALANT BEHIND FIN EXTERIOR 7/16" MIN I L EDGE DISTANCE n JAMB INSTALLATION DETAIL f I WOOD FRAMING OR 2X BUCK INSTALLATION 7/16" MIN EDGE DISTANCE ROOFING NAIL APPROVED _...___..._... SEALANT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1/4" MAX NOTES: SHIM SPACE 1. INTERIORANDEXTERIOR FINISHES, SYOTHERS, NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY WOOD AND MUST BE DONE PER FMAIAAMANVDMA FRAMING STANDARDS. BY OTHERS SIGNED: 0511712021 SHWINCO ARCHITECTURAL PODUCTS, LLC R�I!C�0171 SERVICES WAY \S 9�+��� DOTHAN. AL 36303 •��CENS�, `\�v SERIES 9050 HS WINDOW _*• 0 15 *= IMPACT HVHZ FIN INSTALLATION DETAILS E ��p , TAT OF DRAWN: DWG NO, REV �'F•'�[OR1Qe:•\��� B \\\ ///SSIOI S1 scaLE NTS DATE 05/04/2020 SDHEE114 OF 17 \\vv II i L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 Luis R. Lomas P.E. FL No.: 62514 43"8&0609 rllomas@/domaspe.com APPROVED SEALANT BEHIND FIN #8 WOOD SCREW 7/16" MIN EDGE DISTANCE EXTERI 7/16" MIN EDGE DISTANCE #8 WOOD SCREW APPROVED SEALANT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION WOOD FRAMING BY OTHERS 14" MAX. IM SPACE R 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS REVISIONS OESCRIPRON DATE I APPROVED 1 /4" MAX Ir SHIM SPACE WOOD FRAMING BY OTHERS #8 WOOD SCREW U INTERIOR 1 1 MIN. N. EMBEDMENT L1 APPROVED SEALANT BEHIND FIN EXTERIOR 7/16" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLER'S RESPONSIBILITY AND MUST BE DONE PER FMA/AAMAIWDMA STANDARDS. SIGNED: 0511712021 SHWINCO ARCHITECTURAL PRODUCTS, LLC171 1R 11�b����% JET SERVICES ``\`�`s DOTHAN, AL 36303 `��i•��CEN3FgcP�-`� 0 51 *= SERIES 9050 HS WINDOW*• IMPACT HVHZ FIN INSTALLATION DETAILS TATE OF.-?ZZZ � DRAWN: DWG NO. REV'cF•'cCpR1OQ;• 08-03556 SCALE — NTS 05/04/2020 ISIIEET15 OF 17 Luis R. Lomas P.E. FL No.: 62514 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434£9B-0609 r/lomas@Momaspa.wm APPROVED SEALANT BEHIND FIN #8 SMS OR SELF DRILLING SCREW 7/16" MIN EDGE DISTANCE M ETAL STRUCTURE BY OTHERS W' MAX. IM SPACE METAL STRUCTURE BY OTHERS #8 SMS OR SELF DRILLING SCREW 1 /4" MAX r SHIM SPACE REVISIONS I REV I OESCRIPTION I DATE I APPROVED INTERIOR EXTERIOR INTERIOR APPROVED SEALANT U BEHIND FIN EXTERIOR 7/16" MIN �I EDGE DISTANCE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION 7/16" MIN EDGE DISTANCE #8 SMS OR SELF DRILLING SCREW APPROVED SEALANT BEHIND FIN VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1/4" MAX NOTES: SHIM SPACE 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 3. WATER PROOFING IS INSTALLERS RESPONSIBILITY METAL AND MUST BE DONE PER FMA/AAMAANDMA STRUCTURE STANDARDS. BY OTHERS SIGNED: 0511712021 SHWINCO ARCHITECTURAL PODUCTS, LLC I !L1�171 SERVICES WAY `\J`51R `9X% DOTHAN, AL 36303 ` v,•�\�ENSF,cf' SERIES 9050 HS WINDOW *• Oy5125 *� IMPACT HVHZ =,9 FIN INSTALLATION DETAILS ��0 • TAT OF, DRAWN: OWG NO, REV O'C�• Z0RI'DV'- 8— ���isS/0NA 'SCALE NTS DATE OS/04/2020 s03E 56 OF 17 1G\�� L. ROBERTO LOMAS P.E. L1115 R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 FL No.: 62514 434£8B-0609 r1lomas@Idomaspe.mm 3 7/8" -{ 0 2 5/16" 2 11/16" FIN FRAME (VM-2363) PVC 1 i - � �,- 3T TRACK (VM-2372) PVC 1 •' 7/16" 2"SILL RISER ALUMINUM 11/,6" Ei:[ 3 7/8" Till0 -7 3/4.. Q 2 5/16" O 1 / 16' ��q�0❑ a� Q ° 2 1/4" FLANGE FRAME (VM-2363) FIXED MEETING RAIL (VM-2359) PVC PVC 1 1/4" T- Ti 1 7/16" L BEAD (VM-2365) STILE REINFORCEMENT�11211) PVC ALUMINUM REVISIONS I REV I DESCRIPTION I DATE I APPROVED 2 3/16" VEF- 2 1 /2" LIFT STILE (VM-2361) PVC --{ 1 3/8 1 /2' SASH REINFORCEMENT (T-11222) ALUMINUM 1' 1' 1 /8" ANN 0.090" PVB BY EASTMAN 0.090" PVB BY EASTMAN 3/16" ANN 1/8" ANN 3/16" TEMP 1/8" ANN DURASEAL DURASEAL BY QUANEX BY QUANEX DOW 995 DOW 995 3/4" BITE 3/4" BITE (1l A71N(33 A (331 A71N(; R 1 1/2" 1 5/8" :il I —I SASH HEAD (VM-2358) PVC 7/8" 1 3/8" MEETING RAIL REINFORCEMENT T--11333 ALUMINUM 3/16" JT— INSTALLATION CLIP GALVANIZED STEEL SHWINCO ARCHITECTURAL PRODUCTS, LLC 171 JET SERVICES WAY DOTHAN, AL 36303 1 3/4" 15/1 o I LOCK STILE (VM-2360) PVC 11/16" i16" 314 " SILL RISER ALUMINUM I SERIES 9050 HS WINDOW I IMPACT HVHZ COMPONENTS DRAWN: DWG No. I REV R.L. 08-03556 — SCALE NTS DATE 05/04/2020 SHEET 17 OF 17 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 rI1cMaS@Ir10masp0.00m SIGNED: 0511712021 ``\\``.b 1R IL 0't1''/�i • *\C, E N 5 F i�'PF•�;[ORIDQ'• �i'�� Luis R. Lomas P.E. FL No.: 62514