Loading...
HomeMy WebLinkAboutEngineeringREVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEG-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982PROJECT SITEPROJECT SITESCODES AND STANDARDSPROJECT DESCRIPTION:OWNERHOUSE PHOTOEQUIPMENT SUMMARY90 REC ALPHA: REC395AA PURE BLACK (395W)MODULES90ENPHASE IQ7PLUS-72-2-US MICROINVERTERS90x395 REC ALPHA: REC395AA PURE BLACK (395W)MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESVICINITY MAPSHEET INDEXG-01COVER SHEETA-01ROOF PLANS-01MODULE LAYOUTS-02ATTACHMENT DETAILS-02.1STRUCTURE CALCULATIONSHEET SHEET DESCRITIONCOVER SHEETA-00NOTES AND DESCRIPTIONELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:DESIGN CRITERIA:WIND SPEED (ULT): 160WIND SPEED (ASD): 124RISK CATEGORY:IIEXPOSURE:CS-01.1ARTIAL RESSURE AND MODULES EXOSUREPES SOLAR290 SPRINGVIEW COMMERCE DRSTE 3 DEBARY FL 327134848PH: (321) 356-0249INSTALLERCastillo Engineering Services LLC620 N. Wymore Road, Suite 250,Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590ENGINEERWESTLING, JOHNE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGDS-01-07DATA SHEETSGOVERNING CODES :FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)NATIONAL ELECTRICAL CODE 2017 (NEC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)ASCE 7-16I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLARENERGY CENTER CERTIFICATIONI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED.,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS.35.550 kW PV SYSTEM6201 OLEANDER AVENUE,FORT PIERCE, FL 34982WESTLING RESIDENCESYSTEM SIZE: 35.550 kW DC STCARRAY AREA #1:219.08 SQ. FT.ARRAY AREA #2:258.92 SQ. FT.ARRAY AREA #3:258.92 SQ. FT.ARRAY AREA #4:478.00 SQ. FT.ARRAY AREA #5:179.25 SQ. FT.ARRAY AREA #6:398.33 SQ. FT.RACKING: QRAIL LIGHTATTACHMENT: S-5-N MINI System DescriptionThis system is a grid-tied, PV system, with PV generation consisting of 90REC ALPHA: REC395AA PURE BLACK (395W) MODULES with a combined STCrated dc output power of 35550 W. The modules are connected into 90 ENPHASEIQ7PLUS-72-2-US MICROINVERTERS. The inverter has electronic maximumpower point tracking to maximize energy captured by the PV modules. The inverteralso has an internal ground fault detection and interruption device that is set todisconnect the array in the event that a ground fault that exceeds one ampereshould occur. The inverter has DC and AC disconnect integrated system and labelsare provided as required by the National Electrical CodeWhen the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used to contributeto the power requirements of the occupancy. If PV power meets the requirementsof the loads of the occupancy, any remaining PV power is sold back to the utility.When utility power is available, but PV power is not available, building loads aresupplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramSection..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD Over Current Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUnless Noted Otherwise VIF Verify In FieldWP Weather ProofBatteryBATUtility meterUMGPGeneration PanelMDPMain Distribution PanelSoladeckSDNAVD North American Vertical datumUNOMID Microgrid Interconnect DeviceREVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982NOTES ANDDESCRIPTIONREC ALPHA: REC395AAPURE BLACK (395W)MODULES71.7"40.00"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES···1926.502(D)(15)ALLOWABLE DESIGN PRESSUREPSFDOWN PRESSURE75.0UPLIFT PRESSURE, 2 RAILS75.0Symbols:Abbreviations:Symbols:Abbreviations: UMMSDACDDISCMSDSDSDSDSDSDSD328'-3"306'-6"138'-11"193'-3"467'-2"499'-9" 261'-8"171'-11"107'-1"123'-10" GEN SUBSUBLCATS REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982ROOF PLANROOF PLAN WITH PROPERTY LINESA-01SCALE: 1/16" = 1'-0"1OLEANDER AVENUEEXISTINGDRIVEWAYROOF #2(13) REC ALPHA: REC395AAPURE BLACK (395W) MODULESROOF #3(13) REC ALPHA: REC395AA PUREBLACK (395W) MODULESROOF #4(24) REC ALPHA: REC395AAPURE BLACK (395W) MODULESROOF #5(09) REC ALPHA: REC395AA PUREBLACK (395W) MODULESROOF #6(20) REC ALPHA:REC395AA PUREBLACK (395W)MODULES3/4" IMC, RMC, FMC, LFMC, FMT,OR EMT CONDUIT RUN(N) (90) ENPHASE IQ7PLUS-72-2-USMICROINVERTERS(N) SOLADECKROOF #1(11) REC ALPHA: REC395AA PURE BLACK(395W) MODULES(E) SERVICE POINT AND UTILITY METERING(E) MAIN SERVICE DISCONNECT #A(N) ALTERNATIVE POWER SOURCE AC DISCONNECT/ RAPID SHUTDOWN(N) SOLAR LOAD CENTER(E) SUB PANEL #APOOL1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1' - 6 " F I R E S E T B A C K1'-6" FIRE SETBACK1' - 6 " F I R E S E T B A C K1'-6" FIRE SETBACK1' - 6 " F I R E S E T B A C K 1' - 6 " F I R E S E T B A C K1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK1'-6" FIRE SETBACK(E) GENERATOR(E) MAIN SERVICE DISCONNECT #B(E) SUB PANEL #B(E) AUTOMATICTRANSFER SWITCHPANEL(N) OUTDOOR ENCLOSED 2-POLE CIRCUIT BREAKER/ RAPID SHUTDOWN 115'-0"114'-3"4'-0"(TYP.)REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982MODULE LAYOUTS-01SCALE: 1/16" = 1'-0"1MODULE LAYOUTGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP RAFTERS SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:WINDZONESNON - EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14'-0"1'-4"2'-8"1'-4"ZONE 1'XXXXZONE 2e2'-8"1'-4"1'-4"1'-4"ZONE 2nXXXXZONE 2r2'-8"1'-4"1'-4"1'-4"ZONE 3e2'-8"1'-4"1'-4"1'-4"ZONE 3rXXXXMODULE TYPE, DIMENSIONS & WEIGHTLEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)NUMBER OF MODULES = 90 MODULESMODULE TYPE = REC ALPHA: REC395AA PURE BLACK(395W) MODULESWEIGHT = 45.1 LBS / 20.4 KG.MODULE DIMENSIONS = 71.7" x 40.00" = 19.92 SFUNIT WEIGHT OF ARRAY = 2.26 PSFDYNORAXX DYNOBONDSEE SPEC. SHEET/DS-06PV MODULEMODULE FRAMEROOFROOF TYPEARRAYAREA(Sq. Ft.) ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHRAFTERSIZESEAMSPACING#1METAL STANDINGSEAM219.08482.8045.3826.6°180°2"X4"16" O.C.#2METAL STANDINGSEAM258.92603.8142.8826.6°180°2"X4"16" O.C.#3METAL STANDINGSEAM258.92531.0848.7526.6°180°2"X4"16" O.C.#4METAL STANDINGSEAM478.00784.1060.9626.6°90°2"X4"16" O.C.#5METAL STANDINGSEAM179.25434.0241.3026.6°180°2"X4"16" O.C.#6METAL STANDINGSEAM398.33981.2840.5926.6°270°2"X4"16" O.C.SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.2) EXISTING RESIDENTIAL BUILDING IS AN METAL STANDING SEAMROOF WITH MEAN ROOF HEIGHT IS 15 FT AND SYP 2"X4" ROOF SEAMSPACED 16" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEMRETROFIT IS 26.6 DEGREES. CONTRACTOR TO FIELD VERIFY ANDSHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXISTBETWEEN PLANS AND IN FIELD CONDITIONS.3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18"EACHWAY FROM HIPS AND VALLEYS PER NFPA 1, 11.12.24) THE EXISTING ROOF AND STRUCTURE WILL NOT BE ADVERSLYAFFECTED BY THE ADDITIONAL LOADS IMPOSED BY THE SOLARSYSTEM..*I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED. CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERALAND UPLIFT FORCES AND EQUIPMENT DEAD LOADS. *ROOF #4(24) REC ALPHA: REC395AA PUREBLACK (395W) MODULESROOF #5(09) REC ALPHA: REC395AA PUREBLACK (395W) MODULESROOF #6(20) REC ALPHA:REC395AA PURE BLACK(395W) MODULESROOF #1(11) REC ALPHA: REC395AAPURE BLACK (395W) MODULESROOF #2(13) REC ALPHA:REC395AA PURE BLACK(395W) MODULESROOF #3(13) RECALPHA:REC395AAPURE BLACK(395W)MODULES(251) PV ROOF ATTACHMENT@ 16", 32", 48" & 64" O.C. MAX.(SEE SHEET S-02 FOR ATTACHMENTDETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULE)(N) (90) ENPHASEIQ7PLUS-72-2-USMICROINVERTERS(N) QRAIL LIGHT RAIL (TYP.)(E) BACK YARDROOF #1TILT - 26.6°AZIM. -180°ROOF #2TILT - 26.6°AZIM. -180°ROOF #3TILT - 26.6°AZIM. -180°ROOF #5TILT - 26.6°AZIM. -180°ROOF #4TILT - 26.6°AZIM. -90°ROOF #6TILT - 26.6°AZIM. -270°(E) FRONT YARD 9'-4"7'-11"11'-10"8'-0"8'-0"7'-9"7'-10"7'-9"7'-8"8'-8"10'-2"8'-8"15'-2"10'-10"8'-8"11'-4"9'-4"9'-4"9'-3"9'-3"8'-9"8'-0"7'-9"7'-9"18'-0"9'-2"13'-11"7'-7"7'-7"13'-0"10'-6"P1P2P3P4P5P6P7P8P9P10P11P12P13P13P14P15P16P17P18P19P20P21P22P23P24P25P26P27P28P29P30P31P32P33P34P35P36P37P38P39P40P43P41P42P44REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982PARTIAL PRESSURE AND MODULES EXPOSURES-01.1SCALE: 1/16" = 1'-0"1ARTIAL RESSURE ANDMODULES EXOSURENOTE : PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.2h2DISTANCE : 10"0.5hDISTANCE : 7'-6"LEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)- MISSING MODULE(E) BACK YARD(E) FRONT YARDROOF #4(24) REC ALPHA: REC395AA PUREBLACK (395W) MODULESROOF #5(09) REC ALPHA:REC395AA PURE BLACK(395W) MODULESROOF #1(11) REC ALPHA: REC395AAPURE BLACK (395W) MODULESROOF #2(13) REC ALPHA: REC395AA PUREBLACK (395W) MODULESROOF #3(13) REC ALPHA: REC395AA PUREBLACK (395W) MODULESROOF #6(20) REC ALPHA: REC395AAPURE BLACK (395W) MODULES2h20.5hALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 75 PSFALLOWABLE MODULE DOWN PRESSURE 2 RAILS: 75 PSF*MODULE RAILING MAY BE INSTALLED INLANDSCAPE ORIENTATION FOR MODULES WITHWEIGHTED PRESSURES BELOW 33 PSF*ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 75 PSFALLOWABLE MODULE DOWN PRESSURE 2 RAILS: 75 PSF S-5-N Mini Clamp1.M8-1.25 SS Hex Flange Bolt (13mm Socket)2.3/8-24 SS Round Point Setscrew (3/16 Hex Drive)3.Metal Roof4.General Notes:FrontRightTopLeftBackS-5-N Mini9.5513.5115.0019.91M8-1.25 Threaded Hole15.0012.7730.003/8-24 Threaded Hole42.9541.1439.8318.6341.5621.182.3.1.4.REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982ATTACHMENT DETAIL2ATTACHMENT DETAILS-021ATTACHMENT DETAIL (FRONT VIEW)S-02SCALE: 1" = 1'-0"(N) END CLAMPS-5-N MINIQRAIL LIGHT (TYP)(N) MID CLAMP(E) SNAP-LOCK SEAM 1.0"HIGH AND 16" O/C16" SEAM SPACE2ATTACHMENT DETAILS-02SCALE: NTSPV MODULE REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982STRUCTURECALCULATION L1L2NGREVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982ELECTRICALLINE DIAGRAMENPHASE IQ7PLUS-72-2-USMICROINVERTERSSOLAR ARRAY (35.550 KW-DC STC)(90) REC ALPHA: REC395AA PURE BLACK (395W) MODULES(06) BRANCH OF 13 MODULES(01) BRANCH OF 12 MODULESL2L1NL2L1GN20A/2PG15A(N) 200A SOLARSUBPANEL, 240VL2L120A/2PGQ CABLEL2L120A/2P#6 BARE CU WIRE PROTECTED PER NEC 250.64(B)L2L120A/2PL2L120A/2PENPHASEENVOYL2L120A/2P(N) SOLTECTION RU-2-LP600 V, NEMA 3UL LISTEDL2L120A/2PPV MODULESSUPPLY SIDE CONNECTIONUSING INSULATION PIERCINGOR POLARIS TAPS PER NEC705.12(A)(E)BI-DIRECTIONALSERVICE POINT ANDUTILITY METERING1-PHASE, 240VL2L1L2L1NGL2L1L2L1L1L2NL2L1L2L1L1L2NTO UTILITY GRIDL1L2NGNL2EXISTING GROUNDINGELECTRODE SYSTEMNGGL1G(E) SUB PANEL #1, INSIDERESIDENCE 200A RATED, 240VL1L2NGL1L2NGL1L2NGL1L2NGL1L2NL1L2N(E) MAINBREAKER,200A/2P,240V.G(E) MAIN BREAKER 200ARATED, 240V, MSD #1L1L2NL1L2N(E) MAINBREAKER,200A/2P,240V.(E) MAINBREAKER200A RATED,240VMSD #2GGUTTER BOXEXISTING WIRE AND CONDUITEXISTING WIRE ANDCONDUIT(3) 10/2 NMC RUN IN ATTIC(IN INTERIOR DRY LOCATION ONLY)OR(3) #10 AWG THWN-2 – RED(3) #10 AWG THWN-2 – BLACKEGC #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC, FMT OR EMTCONDUIT RUN(3) #12 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" PVC, IMC, RMC,LFMC,RTRC,LFNC, EMT, FMT ORCONDUIT RUN(3) 1/0 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1-1/2" IMC, RMC,LFMC,RTRC,LFNC, EMT, PVC,FMT ORCONDUIT RUN(4) 10/2 NMC RUN IN ATTIC(IN INTERIOR DRY LOCATION ONLY)OR(4) #10 AWG THWN-2 – RED(4) #10 AWG THWN-2 – BLACKEGC #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC, FMTOR EMTCONDUIT RUNSCALE: NTS1ELECTRICAL LINE DIAGRAME-01NOTE:1.SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION,INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUMNUMBER OF MODULES PER STRING, MAXIMUM OUTPUT,MODULE MANUFACTURER AND MODEL NUMBER, INVERTERMANUFACTURER AND MODEL NUMBER, AS APPLICABLE.2.PROVIDE TAP BOX IN COMPLIANCE WITH NEC 312.8 IF PANELGUTTER SPACE IS INADEQUATE.3.IF THE FUSED AC DISCONNECT WIRE RUN EXCEEDS 10 FTFROM THE POINT OF INTERCONNECTION, CABLE LIMITERS ORCURRENT-LIMITED CIRCUIT BREAKERS MUST BE INSTALLEDFOR EACH UNGROUNDED CONDUCTOR PER NEC 705.31.GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGDYNOBONDJUMPERL2L1NGL2L1NG(E) MAIN BREAKER,200A/2P,240V.L2L1L2L1GL2L1L2L1L2L1L2L1L1L2NN(E) SUB PANEL #2, INSIDERESIDENCE 200A RATED, 240VNG(E) 400AGENERATORAUTOTRANSFERSWITCH/MAINSERVICEDISCONNECTTOGENERATOR12KWNL2L1GEXISTING WIRE ANDCONDUIT(E) MAINBREAKER,200A/2P,240V.EXISTING WIRE ANDCONDUIT(E) MAINBREAKER,200A/2P,240V.G(N) ALTERNATIVE POWERSOURCE AC DISCONNECT/RAPIDSHUTDOWN:240V, 200AMP RATED,NEMA 3R, UL LISTED, LOCKABLE &NON FUSIBLEL2L1NGL2L1NG(N) 150A RATED OUTDOORENCLOSED 2-POLE 150ACIRCUIT BREAKER/ RAPIDSHUTDOWN(3) 1/0 AWG THWN-2IN 1-1/2" IMC, RMC,LFMC,RTRC,LFNC, EMT, PVC,FMT ORCONDUIT RUN REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982WIRING CALCULATIONSAC CONDUCTOR AMPACITY CALCULATIONS:FROM ROOF TOP SOLADECK TO COMBINER BOXAC CONDUCTOR AMPACITY CALCULATIONS:FROM AC COMBINER BOX TO MSPELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELEDFOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TOTHE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES ANDSTANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARENOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FORUSE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).17.THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PVCONDUCTORS IN COMPLIANCE WITH NEC 690.12.18.LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWNON SHEET E-03.19.ALL CONDUITS TO BE INSTALLED A MINIMUM OF 7/8" ABOVE THE ROOFSURFACE.I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PVELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE.FBC 107, THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDASOLAR ENERGY CENTER CERTIFICATION UMMDPACDDISCMDPSUBSUBLCATS REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982SYSTEM LABELINGRAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECT(PER CODE: NEC690.56(C)(3))LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 108.90 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)DATA PER PANELTURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE VISIBLE, REFLECTIVE AND SUITABLE FORTHE ENVIRONMENT WHERE IT IS INSTALLED [NFPA 11.12.2.1]· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]WARNINGIN CASE OF EMERGENCY, CONTACT:PES SOLARPH. NO. : (321) 356-0249LABEL LOCATION:MAIN DISCONNECT(PER CODE: NFPA 11.12.2.1.5)6201 OLEANDER AVENUE, FORT PIERCE, FL 34982LABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NEC 690.56(B) AND NEC 705.10)CAUTION!POWER TO THIS BUILDINGSUPPLIED FROM MULTIPLE SOURCES EMERGENCY RESPONDER:THIS SOLAR PV SYSTEM IS EQUIPPEDWITH RAPID SHUTDOWN.TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''POSITION TO SHUTDOWN ENTIRE PV SYSTEMPV SOLAR ARRAYSERVICE POINT ANDUTILITY METERINGMAIN DISTRIBUTIONPANELALTERNATIVE POWER SOURCE ACDISCONNECT/RAPID SHUTDOWNSOLAR LOAD CENTEROLEANDER AVENUESUB PANELATS PANELOUTDOOR ENCLOSED 2-POLE CIRCUIT BREAKER/RAPID SHUTDOWN REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-01.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-04CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-05CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-06CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWESTLING RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-07CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6201 OLEANDER AVENUE, FORT PIERCE, FL 34982DATA SHEET