Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
� i I V�J {��S " V - wrightsoft Project Summary MASTER MINISPLIT QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946iPhone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM For. St..Lucie County Notes: Permitting Winter D Outside db Inside db Design TD Heating S Structure Ducts Central vent (0 cfm) (none) Humidification Piping Equipment load Method Construction quality Fireplaces Area (ftz) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Heating Equipn ABIGAYLE SEWELL 4708 PINETREE DRIVE, FORT PIERCE, FL Weather. nditions 42 °F 70 °F 28 °F �mmary 3348 Btuh 553 Btuh 0 Btuh j 0 Btuh 0 Btuh 3901 Btuh Fort Pierce, FL, US Simplified Average 0 j Heatil�g Cooli� g 1400 1400 0.69 0.36 16 8. Make Daikin Trade DAIKIN Model RX09NMVJU AHRI ref 8064265 'I Efficiency Heating input Heating output j I; Temperature rise Actual air flow Air flow. factor Static pressure Space thermostat Capacity balance point = 18 °F Backup: Input = 1 kW, Output = 3494 Calculatior -�- wrightsoRm j RigW 'A EADocumnets\Wrightsoft WAMSEW 1 Summary 9 HSPF 10000 Btuh @ 47°F 30 0 300 cfm 0.077 cfm/Btuh 1.00 in H2O Btuh, 100 AFUE Job: Date: Feb 23, 2022 By: FILE %W®PY Summer Design Conditions Outside db 90 °F Inside db 75 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 5605 Btuh Ducts 869 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier load 0.95 6150 Btuh Equipment sensible Latent Cooling Equipment Load Sizing Structure 1553 Btuh Ducts 229 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 1782 Btuh Equipment Total Load (Sen+Lat) 7932 Btuh Req. total capacity at 0.70 SHR 0.7 ton Cooling Equipment Summary Make Daikin Trade DAIKIN Cond RX09NMVJU Coil FTX09NMVJU AHRI ref 8064265 Efficiency 12.5 EER, 19 SEER Sensible cooling 6300 Btuh Latent cooling 2700 Btuh Total cooling 9000 Btuh Actual air flow 300 cfm Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.78 approved byACCA to meet all requirements of Manual J 8th Ed. .9 Universal 2021 21.0.02 RSU08101 ADDITION.rup Calc = MJ8 Front Door faces: W 2022-Feb-23 17:03:23 Page 1 r. Pr -�- wrightsoft® �co ; 317 ST LUCIE LANE, FORT PIERCE, FL :ct Date: Summary �s Date: Feb 23, 2022 ICE MINISPLIT By: < CALCS, INC. Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM I For. ABIGAYLE SEWELL 4708 PINETREE DRIVE, FORT PIERCE, FL Notes: Weather. Winter Design ,Conditions Outside db 42 OF Inside db i' 70 OF Design TD 28 OF Heating Structure Ducts Central vent (0 cfm) (none) Humidification Piping Equipment load Method Construction quality Fireplaces jImmary 6267 Btuh 883 Btuh 0 Btuh 0 Btuh 0 Btuh 7149 Btuh Fort Pierce, FL, US j Simplified Average :I 0 lHeat34g Area ft Z Volume(ft3) 2776 Air changes(hour 0.57 Eouiv. AVF (cfm) 26 Heating Equipme Make Daikin Trade DAIKIN Model RXB12AXVJU AHRI ref 10574119 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 30 Backup: Input = 2 kW, Output = 6496 Btuh, 100 AFUE Cooling 2776 0.30 14 Summary Cal 9 HSPF 11300 Btuh @ 47°F 28 OF 367 cfm 0.051 cfm/Btuh 0 in H2O °F Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 7406 Btuh Ducts 1323 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 8293 Btuh sensible Latent Cooling Equipment Load Sizing Structure 1077 Btuh Ducts 342 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 1419 Btuh Equipment Total Load (Sen+Lat) 9712 Btuh Req. total capacity at 0.70 SHR 1.0 ton Cooling Equipment Summary Make Daikin Trade DAIKIN Cond RXB12AXVJU Coil FTXB12AXVJU AHRI ref 10574119 Efficiency 8.5 EER, 17 SEER Sensible cooling 7700 Btuh Latent cooling 3300 Btuh Total cooling 11000 Btuh Actual air flow 367 cfm Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.86 ACCA to meet all requirements of Manual J 8th Ed. -0& wrights I I'i 2022-Feb-2317:03:23 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 2 CCA EADocumnets\Wrightsoft WAC\SEWELL ADDITION.rup Calc = MJ8 Front Door faces: W I � , III +'wrightsoft Right-J® Worksheet MASTER MINISPLIT QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 3149416 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@t?AOL.COM Job: Date: Feb 23, 2022 By: 1 Room name MASTER MINISPLIT MASTER 2 EVosed wall 41.0 ft 41.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 175.0 ft 5 Room area 175.0 ft" 175.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (BtuWftl-'F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool :6 - - 'U J--G -- -- --- sw -- 2 glazing, clr low- ' O'j100 b.— n -- -- 0.00 - - 11.18 0.00 21.74 -- - 0 15 - --- - 0 0 - ----- 0 462 -- -- 0 326 ---- -- 0 15 - - --97 0 0 - -- 18-5 0 462 - 115 0 326 (—G 2 glazing, clr low- 1ij100 n 30:80 2.glazing, cir low-e :- 1!100 n - _0.00 :: - 0.00 . _ _ 0_ 0 0 ____0_ - 0 Q 0 _Q. 11 W 12E-0sw 0°068 0.00 no 0 0 0 _ 0 _ 0 _ 0 0 . _ 9j068 _e _ s_ 1.90 _ _ .- 1..18 - -- 112 _ _ . _.._112 -0 -. -,213 __- 133 _--.__.112 _ 112,_. _ 213 133 W_ 12E-0sw 068 w 1.90 1-_18 104 - --104 _ --- -198 -- - 123 _ - _ _ 104 _ 104 - _ _ 198 123 C_--- - _ - _ 0'048 '-- - 1.54 _ _ - __175_ _ _ 175- _ 235 269_._.__-_175 _- 175 - -- 235 :_:269 F_v -- - _17A-17zd __- ------ 22Atph --__ -- --------- ------ 1i358 i i I - -- - _1.34 38.02 _. - _.. -- ------ - __. - _ _0.00 ._ . _ __ -- -- 175 .. -_ - _.. - - 41 - -- _ 1559 ---- ----------------- -- _ 0 -__ 175 - -- -- -- - 6 c)AED excursion q I ? 0 0 Envelope loss/gain '1 2852 965 2852 965 12 a) Infiltration 496 139 496 139 b) Room ventilation 0 0 0 6 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 4500 4501) Subtotal (lines 6 to 13) 3348 5605 3348 5605 Less external load ; 0 0 0 i 01, Less transfer 0 0 0 0 Redistribution 0 0 0 1 0 14 Subtotal 3348 5605 3348 5605 15 Duct loads 17% 15% 553 869 17% 15% 553 869 Total room load 3901 6473 3901 6473 Air required (cfm) 1 300 300 1 300 300 to meet all Right Suite® Universal 2021 21.0.02 RSU08101 A E:\Documnets\Wrightsoft WAC\SEWIELL ADDITION.rup Calc = MJ8 Front Door faces: W 2022-Feb-23 17:03:23 Page'1 1 i +y- wrightsoft Right-J® Worksheet - OFFICE MINISPLIT QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34 I6 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS(a)AOL.COM Job: Date: Feb 23, 2022 By: 1 Room name OFFICE MINISPLrr OFFICE 2 3 Bposed wall Room height 67.0 ft 67.0 ft 4 Room dimensions 8.0 ft 8.0 ft heat/cool 5 Room area 347.0 ftz 1.0 x 347.0 ft 347.0 ft Ty Construction U-value Or HTM AreaLoadLoad number (Btuh/ft� °F) (Btuhlft�) or perimeter (ft) (Bt h) ors perimeter (ft) (Bt h) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-0sw, - - -� 0 068 n - 1.90 1.18 - �216 - -167 -- - 318 - 197 - --- 21t -- —167 --- - 197 2 glazing, cir lower 100 1100 n 30.80 21.74 9 0 277 196 9 0 - 277 196 2 glazing, clrlow-e 100 n 000 0.00 0 0 0 0 0 0 0 0 ._ .. 2glazing, clrlow-e _ _. n_ 30:80 ,. -21.74 - _ 40 -,_ _ 0 _- _1-238--...._ 40 1238 11 W� - W 12E-0sw -- --- - 0!068 b�068 a - _1.96 1.18 ---- --104 164 198 _8.74 123 104 _ _--_ __0 104 _ ., 198 -411 . -._874. 123 W 12E-0sw 0.068 s w _1.90 0.00 1.18 0.00 _ 216 0 _ 216 0 411 0 _ 256 _ _216 _ 216 . 256 C .. F _ - 17A 17zd -_ _ _ 0!048 -1.34 _ _ 1.54 _- - 347 ___- - 347 _ __ 466 _ 0 -. 533 0 - _ 347 _ _- - 0 _ 347 0 - _ __466 _ _ 0 . 533 ----22A-tph_..- -- _ - -- - _._ 1'358 _ -- _ 38.02 ---0.00 �47 ----- 67--- 2548-------0_, ---347 ..------67-------2548 _ ..-_0 _0 6 c)AED excursion I 0 Envelope loss/gain I ;i 5456 2179 5456 2179 12 a) Infiltration 810 228 810 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 l Appliarices/other 5000 5000 Subtotal (lines 6 to 13) I„ 6267 7406 6267 7406 Less ekemal load 0 0 0 1 10 Less transfer 0 0 0 I0 Redistribution 0 0 0 0 14 Subtotal 6267 7406 6267 7406 15 Duct loads 140/6 18%1 883 1323 14% 18% 883 1323 I Total room load f 7149 8730 7149 1493671 8730 l Air required (cfm) I I 367 367 367 calculations approved byACCA to meet all requirements of Manual J 8th Ed. -r�.�^ wrigl �tsoTt� i Right (Suite® Universal 2021 21.0.02 RSU08101 2022-Feb-23 17:03:23 Page 2 E:1Documnets\Wrightson HVAC\SEWELL ADDIT10N.rup Calc = MJ8 Front Door faces: W 1 i it I This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be adde6,1 after purchasing Win2PDF.