Loading...
HomeMy WebLinkAboutProject Information (2) I � FORM R405-2020 FILE COP FLORIDA ENERGY'IEFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SEW ELL ADDITION Builder Name: Street: 4708 PINETREE DRIVE MM � 9 2022 Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL', Permit Number: Owner: ABIGAYLE SEWELL St.Lucie County Jurisdiction: ST LUCIE COUNTY Design Location: FL,Fort Pierce Permitting County: St.Lucie(Florida Climate Zone 2) i 1. New construction or existing Addition 10. Wall Types(864.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Frame-Wood,Exterior R=19.0 864.00 ftZ b.N/A R= ftZ 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms(Bedrms In Addition) 2(2) d.N/A R= ftZ 5. Is this a worst case? No 11.Ceiling Types (522.0 sqft.) Insulation Area I, a.Under Attic(Vented) R=19.0 522.00 ftZ 6. Conditioned floor area above grade(ftZ) 522 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 7. Windows(64.0 sqft.) Description I' Area 12.Ducts R ftZ a. U-Factor: Sgl,U=1.10 40.00 ftZ SHGC: SHGC=0.25 b. U-Factor: Sgl,U=1.04 II 15.00 ftZ 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.29 a.Central Unit 9.0 SEER:19.00 c. U-Factor: Sgl,U=1.06 it 9.00 ftZ b.Central Unit 11.0 SEER:17.00 SHGC: SHGC=0.28 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.264 a.Electric Heat Pump 17.0 HSPF:9.00 b.Electric Heat Pump 17.0 HSPF:9.00 8. Skylights ;i Area c. U-Factor:(AVG) N/A ftZ 15.Hot water systems -None required SHGC(AVG): N/A a. Ca :N/A P 9. Floor Types (522.0 sqft.) !i Insulation Area EF:0.000 a:Slab-On-Grade Edge Insulation R=0.0 522.00 ftZ b. Conservation features b.N/A , R= ftZ None c.N/A R= ftZ 16.Credits None Total Proposed Modified Loads: 15.50 Glass/Floor Area: 0.123 PASS Total Baseline Loads: 20.75 I hereby certify that the plans and spe,l ifications covered by Review of the plans and this calculation are in compliance with'the Florida Energy specifications covered by this C� Q Code. calculation indicates compliance 4111 with the Florida Energy Code. raur ''�r •__ , `�„ O ` IQQPREPARED BY: 'i Before construction is completed ' DATE: 2-24-2022 this building will be inspected for compliance with Section 553.908 * �" I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD yVG` OWNER/AGENT' BUILDING OFFICIAL: DATE: DATE: I I'' - Compliance requires certification!by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). - Pr'oposed Qn of NAN exceeds the'performance method default limit of 0.08 and therefore does not require duct testing.R405 .2.31 I 2/23/2022 5:10 PM En IrgyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 ,I I � I i T FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SEWELL ADDITION Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 522 Lot# Owner Name: ABIGAYLE SEW ELL Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4708 PINETREE DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY ;j Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: Addition Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name I!i Area Volume 1 MASTER MINISPLI 175 1400 2 OFFICE MINISPLIT ill 347 2776 SPACES Number Name j Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 175 1400 No 0 1 1 Yes Yes Yes 2 OFFICE j 347 2776 No 0 1 1 Yes Yes Yes FLOORS # Floor Type i Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulati�n MASTER BEDRO 41 ft 175 ft2 —__ 1 0 0 2 Slab-On-Grade Edge Insulation OFFICE 67 ft 347 ftz ___ 1 0 0 j ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) III 1 Flat Flat tile/slate 522 ftZ 0 ftz Medium N 0.3 No 0.9 No 0. 0 ATTIC i V/ j# Type p Ventilation Vent Ratio(1 in) Area RBS IRCC i 1 No attic Vented 150 522 ftz N N I i � f i ii ,i 2/23/2022 5:10 PM Energy paugew USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 4 I FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 19 Blown 175 ft2 0 Wood 2 Under Attic(Vented) OFFICE 19 Blown 347 ft2 0 Wood I. i WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceR-1/aIlle Et n Arp-q Sor_ 1 N Exterior Frame-W ood MASTER BE 19 14 0 8 0 112.0 ft2 0 0.1 0.3 0 _ 2 S Exterior Frame-Wood MASTER BE 19 14 0 8 0 112.0 ft2 0 0.1 0.3 0 _ 3 W Exterior Frame-Wood MASTER BE 19 13 0 8 0 104.0 ft2 0 0.1 0.3 0 4 N Exterior Frame-Wood OFFICE 19 27 0 8 0 216.0ft2 0 0.1 0.3 0 5 E Exterior Frame-Wood OFFICE 19 13 0 8 0 104.0 ft2 0 0.1 0.3 0 6 S Exterior Frame-Wood OFFICE 19 27 0 8 0 216.0 ft2 0 0.1 0.3 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall I! Overhang �/ # Ornt ID Frame P i pries NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-EI,Single Yes 1.04 0.29 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 N 4 Metal Low-E,iSingle Yes 1.06 0.28 Y 9.0 ft2 2 ft 0 in 1 ft 4 in None None 3 N 4 Metal Low-E;Single Yes 1.1 0.25 Y 40.0 ft2 2 ft 0 in 1 ft 4 in None None I.I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 1 000254 348 19.09 35.84 .0902 5 HEATING SYSTEM # System Type III Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/Sup pIemen Split Single HSPF:9 17 kBtu/hr 1 (Ductless 2 Electric Heat Pump/Supplemen Split Single HSPF:9 17 kBtu/hr 2 Ductless COOLING SYSTEM i # System Type I Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for a Split Single SEER:19 9 kBtu/hr 270 cfm 0.8 1 Ductless 2 Central Unit/Supplementl I for a Split Single SEER:17 11 kBtu/hr 330 cfm 0.8 2 Ductless SOLAR HOT WATER SYSTEM FSEC Collector Storage { Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 I i 1 2/L022 5:10 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 4 i FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES ProgramableThermostat: N Ceiling Fans: Coolingan Feb Mar A r Ma Jun Jul Au Se Oct Nov Dec Heatin H Jan HFeb Mar W APr May Jun Jul Au ([ Sep Oct NNov Dec Ventin Jan Feb Mar A r May Jun Jul Aug [ Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68, 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS ; Mass Type I Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 MASTER BEDROO Default 8 Ibs/s .ft. ft2 ft 0.3 OFFICE I I j it I III ii I I it 'I 2/23/2022 5:10 PM En IrgyGauge@ USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 4 i 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a I� I I Project Name: SEW ELL ADDITION Builder Name: n Street: 4708 PINETREE'DRIVE Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE I,;'FL, Permit Number: v Owner: ABIGAYLE SEWELL Jurisdiction: ST LUCIE COUNTY = Design Location: FL,Fort Pierce 0 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous aHbarrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks orjoints'in the air barrier shall be sealed. The air barrier ii any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of,the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shad be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous, alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall linclude the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) 'I be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior , , or unconditioned„s pace shall be sealed. "I Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. 'I Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light h6res installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the!finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an i plumbing in exterior walls,or insulation that on installation readily conforms to available space shall f extend behind piping and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be I on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier stroll be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply, and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling Concealed When required id be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other ,adhesive sealants" shall not be used to fill voids between fire sprinkler cover plates and'walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. yGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 2/23/2022 5:10 PM Energ i I I I