Loading...
HomeMy WebLinkAbout1st Floor PlanTogrig n I CO -FLOOR PLAN SC", 1/4 glgi 28'-l" 13'-10" 13'-2" 13'-2" 1'-4,0 13'-10n ------------------- - ------------------- ---------------- 1-1 -------------------- 7'-5" 10*-0" 5'-8- X W3 L L W6 PERED_ Q ,Cq LU GLASS I 301 U I BATH - LLI I OLL011 CLG I 7-3" FAMILY ROOM A COVERED LANAI CPFFERED CL.G 10'-0'CLG Oa 11 11 W3 22, ti 3 LU cc C) BREAKFAST DEN lo 11 3 1941 CLG BEDROOM 2 Of W3 I I(Y-011 CLO 9 — — — — — — — — 0/0' 101-1)"CLO Iv EQ a EQ Li V_a IS, kEJQ\\ It" - �=5'-41' EQ III IEQ It' W3 Icn CC BEDROOM 0 IIY-IY'CLG Puj 13'-6" 16'- 1 15-4" KITCHEN 0 (0 I LU MASTER BEDROOM j o 0 LILI Cq COFFERED CLG Ain ej-; 0 W-6- LIVING ROOM Oil REF C) 1 C14 q I q: (f) Won 12�O" CLG _Cq -1 — 'cj 2 BATH 2 Uj CO S-O" 3,-;?, 81 �347 5*-2 -4 to .01 A I 0 (n U.11 6 j W3Z 1) (D 1_� it 3'-51" r -8" L 2'-8" L iti, 6-10" no,ol, ^C,4 C nN r-7 — — — — — — — — — Zq \ 4i- 13 0 -1 1 31' 2'- 12*-8" 12% I to to I 1 I (DINING ROOMI 10 W) C WIC I I 1 I CPFFERED CLG I BEDROOM 47 I0,-01CLD *if) 0 91 CLG RING WALL 00 L'DRY 1014, CLG X 8'S SYP AT 16"Q�Q� J2 12'8" to-U'CLG G LU CC CLG 7f FOYER r I V-84 I 5 MkR E O�Atb GLASS _C0 I 0 0 U CONCRETE 110 WZ BOL.ARD W N3 I CL9 MASTERI BATH \ W 11 14 11 1 -L' 132 -1" D11 - 2 ­`01 GAR GE 0,011 ct P2 X 48 ATTr o ACCESS L_ j too '0 W3 �< I In 1 5'-61 11 )L - - - - - - - 11 1 1 W3 W3 C0_V,_ERED 'ENTRY If- 4'-1 Cq 2' On 1 5- 1-00 7'-5 2 2�0" �tov" V- - - - - - - - - - - - - - - - G 12'-2" if 12'-6" 2'-5" - - - - - - - - - - - - - - - - - - - - - - 12'-5 - - n -- - - 3*-2" 8'-2" 3!-2* 24'-8" # 20`710" 60 P-On 11 N N3 � W15 W3 N5 W5 SQUARE FOOTAGES FDOH in St. Lucie County Environmental Health A/C = 3340 SO. FT Site Plan Approved for Construction GARAGE/NON—A/C= 439 SO. FT. Supersedes All Previous Site Plans for FRONT PORCH = 119 SQ. FT CISTDS #5&-51c%23ysjTS & Well # REAR PORCHES no 603 $0. FT Reviewer: TOTAL SQ. FOOTAGE = 4,501 SO. FEET Product Approval Submiototco-fl Affidavit Wind Speed: 170 Opening Schedule: Swing Doors, Overhead Doors, Sliding Doors, Fixed Glass, Windows, & Skylights: Opening Product Model # Manufacturer Glass Attachment Method Type Building -Design Product Design ID Description Size, Spacing, & Embedment Pressure Pressure +40.5/-43.9 DI S7SS ENTRY FIBERGLASS DOOR THERMA- TRU FPA# 17114� IMPACT IIIPTC W/1-1/2' CONC. EMBED, 6` MAX FROM JAMS CORNERS 14" o.c. MAX. AT JAMBS, SILL, A%O HEAD +50.0 D2 PVC FRAME I I " ­­ IMPACT' IMP T SLIDING DOOR 1610SGD MI PPA # 18240.5 LOW E 366 INSULATED GLASS FOR CONCRETE INSTALLATION USE USE ELCO 1/4" TAPCONS EMBEOED 13/8' MIN OR 1/4 SS4 CRETE FLEX EMS, 1 3/4 MIN. +65.0/-65.0 G GARAGE DOORS D GALV STEEL WAYNE DALTON I VPA # 18-0417.03 N/A 7-5/16- X 1-5/8- LAG SCREWS WIWASHER HEADS_ EA TRACK BRACKET, SEE BUCK MAIL SHT AS FOP, SPACING. +34.1/-3e.o +34�3/-38.3 W 1 54W X 63&0 SM IMPACT SH IMPACT A ALUMINUM FRAME 185 SERIES SH PPA #17499:1' LOW E 270 INSULATED GLASS TIM i1w 1�f.;UN CONCRETE MINtMbt:0Mt:N1 1-1/2" MIN= DIST I 1/8"AOTE ABOUT IX BVCKS6' ALL CORNERS,(4)0 46C 0 +55 / -SS MEETING RAIL EA.SIDE W2 10W X 96H PW-IMPACT ALUMINUM FRAME 185 SERIES §1i FPA #17499.1' LOW E OBSCURE INSULATED GLASS +55/-55 +55/-55 W3 36 W X 63 H A SHIMPACT _UMINIUM, igglE 185SE , Ill zSH I MI FPA #17499,1', LOW E 270 INSULATED GLASS - ------------- 77-7— +55/-SS W4 48 W X 63 H SH IMPACT ALUMINUM FRAME 185SERIESSH FPA#17499.1' LOW E 270 INSULATED GLASS +55/-5s W5 27WX38H SH-IMPACT ALUMINUM F+R6M IBSSERIESSR-, Wl VPA#17499,1', GREY E OBSCURE SINGLE GLASS +55/-55 S7SS ENTRY FIBERGLASS DOOR THERMA-TRIU FIL # 14665- IRS N/A 1/4"TC W/1-1/2" CO NC. NC, EMBED, 6' MAX FROM JAMB CORNERS & 14- O.C. MAX. AT IAMBS, SILL, AND HEAD +40.5/-43,9 +80,0/-80.0 IMULLION AL FRAME VERT MULL BAR KID IERT MULL KIT AL FRAME Ml FPA 0 15353.2 STA I NDART T CLIP N/A I 6 (2) 1/4" SS ELCO AGGREGAT EMBED, BOTTOM & TOP 0 JAMB SPACING USE 0* +40,5/-43.9 +/-88.2 Product Model # Manufacturer Attachment Method Type, Building -Design Product Design Size,. Spacing,,& Embedment Pressure Pressure Roofing 26 ga. Coastall- Roof 'G'Uv Coast& fit*h�Ofafcturiiiii UnderlayinentshalibeanASTMD2261�pellinst�IW laped with Min Vitalled -.,'.,,W/APProv*d capped 12 ga I Y4 anular ring shank spacedii"olc. laps ZONE I = -42,1 ZONE 2 &L 3 108, 5 ZONE 1 = -691S psf ZONE 2 & 3 - -159.25 psf 'Cripliv 5v- NOA:N0',. 4-0820.02 at all andtwo vows 12' O-Q Panel fasteners shall be #9-15 XI %'Self drilling, self tapping, ficitc head sbrows W/ ending washer Min Panel I penetration 3/16"Inch. I have reviewed the above product approval information and and approved it. CONTRACTOR TO VERIFY AND PROVIDE EXACT ROUGH OPENING SIZES OF ALL WINDOWS AND DOORS Name: BERNARD ]ONES ARCHITECT Signature: Certification. Number: AR 15193 Date: wubaw —ANb DOOR SCHEDULE NO. INDTH X HT. TYPE REMARKS 192"WIDE X 96- HIGH STEEL OVERHEAD GARAGE DOOR IMPACT 36" WOE X 96" HIGH SWING DOOR IMPACT W CATEGORY T'9AFETY 32" ODE X 96- HIGH WOOD DOOR -SOLID WQOQ 1 HQU8j5FLF cLoSi,-EGLASS PER FBC 4 4410,2.3.1.3 24" WIDE X 96" HIGH WOOD DOOR IMPACT W CATEGORY 11 SAFETY GLASS PER FBC 4 4410.2.3.1.3 64- WIDE X 96- HIGH WOOD DOUBLE DOOR IMPACT W CATEGORY 11 SAFETY GILASSYEIR FBC 4 4410.2.3.1.3 66" WIDE X 96" HIGH WOOD 81-FOLD 74" WIDE X 96" HIGH WOOD BI-FOLD 29" WIDE X 96- HIGH WOOD 81-FOLD 29- WIDE X 96- HIGH WOOD 91-FOLD 15" WIDE X 96" HIGH SIDE LIGHTS IMPACT W CATEGORY It SAFETY GLASS PER FBC 4 4410.2.3.1.3 11 38" WIDE X 64" HIGH ALUM. SINGLE HUNG IMPACT W CATEGORY 11 SAFETY GLASS PER FBC 4 4-410.2.3.1.3 28" ODE X 360 HIGH ALUM. SINGLE HUNG IMPACT W CATEGORY 11 SAFETY GLASS PER E2C 4 4410.2,3.1.,]3 72m WIDE X 80" HIGH SLIDING GLASS DOOR IMPACT W CATEGORY 11 SAFETY 3 GLASS PER F 4119 3.1. WIDE X 6e HIGH ALUM. SINGLE HUNG IMPACT W CA GOR 11 CATEGORY SAFETY ... GLASS PER FBC 4 4410.2.3.1.3 (15) [.72" WIDE X 96" HIGH SLIDING GLASS DOOR IMPACT W CATEGORY it -SAFETY GLASS PER EPC.4 1110.2.3.1.3 ARCHITECTS GENERAL CONTRACTORS A ROUND HILL DEVELOPMENT GROUP COMPANY 17968 115 TH AVE. NORTH JUPITER. FLORIDA 33478 PH: 561-216-1000 CELL 561-718-0831 319 ism ST NO. MIAMI BEACH, FL, 33182 305-454-8000 WWW.ADVANCED—DESON—EAJILDING.COM ARCHITECT BERNARD JONES ARCHITECT SEAL: DATE: IJUL,O '3­ riq21 CLIENT: : PDRESSS- 3707 TANAGER PLACE FORT PIERCE FL,34982 I ST FLOOR PLAN, REVISIONS,