Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFO�J,VI R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CASTILLO-RODRIGUEZ Builder Name: ALPHA DESIGN CONTRACTOR, LLC. Street: 3707 TANAGER PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE , FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(2942.5 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2628.50 ftz b. Frame - Wood, Adjacent R=11.0 314.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 11. Ceiling Types (3340.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 3340.00 ftz 6. Conditioned floor area above grade (ftz) 3340 • b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(419.9 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ftz 6 200 a. U-Factor: Sgl, U=0.65 419.92 ftz b. Sup: Attic, Ret: Attic, AH: Garage 6 140 SHGC: SHGC=0.30 b. U-Factor: NIA ftz 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:16.00 c. U-Factor: NIA ftz b. Central Unit 23.6 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 9.508 ft. 14. Heating systems kBtu/3 Efficiency Area Weighted Average SHGC: 0.300 a. Electric Strip Heat b. Electric Strip Heat .0 COP:1.00 17.0 COP:1.00 17 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons _ 9. Floor Types (3340.0 sqft.) Insulation Area EF:0.980 a. Slab -On -Grade Edge Insulation R=0.0 3340.00 ftz b. Conservation features b. N/A R= ftz None c. NIA R= ftz 16. Credits None Total Proposed Modified Loads: 85.29 PASS Glass/Floor Area: 0.126 Total Baseline Loads: 98.17 1 hereby certify that the plans and specifications covered by Review of the plans and ST14E S7- this calculation are in compliance with the Florida Energy specifications covered by this indicates 1•0� Code. calculation compliance � - =.. O PREPARED BY:4 with the Florida Energy Code. Before construction is completed rrr��,"� ,,,, - a: \ DATE: - this building will be inspected for; compliance with Section 553.908 i __,_IltjF. �a - ~ 1 hereby certify that this building, as designed, is in compliance Florida Statutes. CQD with the Florida Energy Code. WE OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 2/10/2021 9:43 AM EnergyGauoe(p) USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Con-01i ant Sc� twarfP f /'"' : �: � 11 gq FnRnn R41715_9ron INPUT SUMMARY CHECKLIST REPORT '',1'e PROJECT Title: CASTILLO-RODRIGUEZ Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3340 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ALPHA DESIGN CONTRACT Rotate Angle: 0 Street: 3707 TANAGER PLACE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE , Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2409 27616.9 2 AHU 2 931 9706 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 2 168 1680 No 0 1 1 Yes Yes Yes 2 FOYER 350 4445 No 0 1 Yes Yes Yes 3 LAUNDRY 108 1080 No 0 1 No Yes Yes 4 BATH 3 60 600 No 0 1 Yes Yes Yes 5 CLST2 14 140 No 0 1 Yes Yes Yes 6 BEDROOM 4 157 1570 No 0 1 1 Yes Yes Yes 7 BEDROOM 3 168 1680 No 0 1 1 Yes Yes Yes 8 HALLWAY 72 720 No 0 1 No Yes Yes 9 CLST 4 20 200 No 0 1 Yes Yes Yes 10 DINING 277 3517.9 No 0 1 Yes Yes Yes 11 CLST 3 14 140 No 0 1 No Yes Yes 12 KITCHEN 436 5232 Yes 0 1 Yes Yes Yes 13 HALL 30 300 No 0 1 Yes Yes Yes 14 BATH 2 54 540 No 0 1 Yes Yes Yes 15 FAMILY 187 2244 No 0 1 Yes Yes Yes 16 LIVING ROOM 294 3528 No 0 1 Yes Yes Yes 17 DEN 176 1760 No 0 1 Yes Yes Yes 18 MASTER BEDROO 396 4356 No 0 1 1 Yes Yes Yes 19 M WIC 1 54 640 No 0 1 Yes Yes Yes 20 M WIC 2 45 450 No 0 1 No Yes Yes 21 M TOILET 30 300 No 0 1 Yes Yes Yes f 2/10/2021 9:43 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ` SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 M BATH 230 2300 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 2 12 ft 0 168 ft2 --- 1 0 0 2 Slab -On -Grade Edge Insulation FOYER 14 ft 0 350 ft2 -___ 1 0 0 3SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 108ft2 __-_ 1 0 0 4 Slab -On -Grade Edge Insulation BATH 3 6 ft 0 60 ft2 ___ 1 0 0 5SIab-On-Grade Edge Insulation CLST2 2ft 0 14 ft2 ___ 1 0 0 6 Slab -On -Grade Edge Insulation BEDROOM 4 12 ft 0 157 ft2 ___ 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 3 12 ft 0 168 ft2 ___ 1 0 0 8 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 72 ft2 _-__ 1 0 0 9 Slab -On -Grade Edge Insulation CLST 4 2ft 0 20 ft2 -- 1 0 0 10SIab-On-Grade Edge Insulation DINING 13 ft 0 277 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation CLST 3 1 ft 0 14 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation KITCHEN 12 ft 0 436 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation HALL 5 ft 0 30 ft2 ___ 1 0 0 14SIab-On-Grade Edge Insulation BATH 2 15 ft 0 54 ft2 1 0 0 15SIab-On-Grade Edge Insulation FAMILY 22 ft 0 187 ft2 -___ 1 0 0 16SIab-On-Grade Edge Insulation LIVING ROOM 11 ft 0 294 ft2 1 0 0 17SIab-On-Grade Edge Insulation DEN 33 ft 0 176 ft2 ___ 1 0 0 18SIab-On-Grade Edge Insulation MASTER BEDRO 24 ft 0 396 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation M W IC 1 9 ft 0 54 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation M W IC 2 1 ft 0 45 ft2 --- 1 0 0 21SIab-On-Grade Edge Insulation M TOILET 5 ft 0 30 ft2 ___ 1 0 0 22SIab-On-Grade Edge Insulation M BATH 35.2 ft 0 230 ftz ---- 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 3734 ftz 0 ft2 Medium N 0.1 No 0.9 No 0 26.57 ATTIC Vent in) Area RBS IRCC V # Type Ventilation Ratio (1 1 Full attic Vented 150 3340 ft2 N N FORM R4n�-gran INPUT SUMMARY CHECKLIST REPORT ' CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type c 1 Under Attic (Vented) BEDROOM 2 30 Blown 168 ftz 0.1 Wood 2 Under Attic (Vented) FOYER 30 Blown 350 ftz 0.1 Wood 3 Under Attic (Vented) LAUNDRY 30 Blown 108 ftz 0.1 Wood 4 Under Attic (Vented) BATH 3 30 Blown 60 ftz 0.1 Wood 5 Under Attic (Vented) CLST2 30 Blown 14 ftz 0.1 Wood 6 Under Attic (Vented) BEDROOM 4 30 Blown 157 ftz 0.1 Wood 7 Under Attic (Vented) BEDROOM 3 30 Blown 168 ftz 0.1 Wood 8 Under Attic (Vented) HALLWAY 30 Blown 72 ftz 0.1 Wood 9 Under Attic (Vented) CLST 4 30 Blown 20 ftz 0.1 Wood 10 Under Attic (Vented) DINING 30 Blown 277 ftz 0.1 Wood 11 Under Attic (Vented) CLST 3 30 Blown 14 ftz 0.1 Wood 12 Under Attic (Vented) KITCHEN 30 Blown 436 ftz 0.1 Wood 13 Under Attic (Vented) HALL 30 Blown 30 ftz 0.1 Wood 14 Under Attic (Vented) BATH 2 30 Blown 54 ftz 0.1 Wood 15 Under Attic (Vented) FAMILY 30 Blown 187 ftz 0.1 Wood 16 Under Attic (Vented) LIVING ROOM 30 Blown 294 ftz 0.1 Wood 17 Under Attic (Vented) DEN 30 Blown 176 ftz 0.1 Wood 18 Under Attic (Vented) MASTER BEDRO 30 Blown 396 ftz 0.1 Wood 19 Under Attic (Vented) M W IC 1 30 Blown 54 ftz 0.1 Wood 20 Under Attic (Vented) M W IC 2 30 Blown 45 ftz 0.1 Wood 21 Under Attic (Vented) M TOILET 30 Blown 30 ftz 0.1 Wood 22 Under Attic (Vented) M BATH 30 Blown 230 ftz 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below ()rot Space In We" lype RAW- Et In Et In Arpm R-11211le Fraction Ahc%or (,rqrJn% 1 N Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 10 0 120.0 ftz 0 0 0.1 0 2 E Exterior Concrete Block- Int Insul FOYER 4.1 14 0 12 8 177.3 ftz 0 0 0.1 0 _ 3 E Garage Frame- Wood LAUNDRY 11 7 0 10 0 70.0 ftz 0 0.1 0.1 0 4 N Exterior Concrete Block- Int Insul BATH 3 4.1 6 0 10 0 60.0 ftz 0 0 0.1 0 5 N Exterior Concrete Block- Int Insul CLST2 4.1 2 0 10 0 20.0 ftz 0 0 0.1 0 6 N Exterior Concrete Block - Int InsuBEDROOM 4 4.1 12 0 10 0 120.0 ftz 0 0 0.1 0 _ 7 E Garage Frame - Wood BEDROOM 4 11 13 0 10 0 130.0 ftz 0 0.1 0.1 0 8 N Exterior Concrete Block- Int InsuBEDROOM 3 4.1 12 0 10 0 120.0 ftz 0 0 0.1 0 9 N Exterior Concrete Block - Int Insul CLST 4 4.1 2 0 10 0 20.0 ftz 0 0 0.1 0 10 E Exterior Concrete Block- Int Insul DINING 4.1 13 0 12 8 164.7 ftz 0 0 0.1 0 11 N Garage Frame - Wood DINING 11 9 0 12 8 114.0ft2 0 0.1 0.1 0 12 S Exterior Concrete Block - Int Insul KITCHEN 4.1 4 0 12 0 48.0 ftz 0 0 0.1 0 13 SW Exterior Concrete Block - Int Insul KITCHEN 4.1 5 0 12 0 60.0 ftz 0 0 0.1 0 14 W Exterior Concrete Block - Int Insul KITCHEN 4.1 3 0 12 0 36.0 ftz 0 0 0.1 0 15 W Exterior Concrete Block - Int Insul HALL 4.1 5 0 10 0 50.0 ftz 0 0 0.1 0 16 N Exterior Concrete Block- Int Insul BATH 2 4.1 6 0 10 0 60.0 ftz 0 0 0.1 0 17 W Exterior Concrete Block - Int Insul BATH 2 4.1 9 0 10 0 90.0 ftz 0 0 0.1 0 18 S Exterior Concrete Block - Int Insul FAMILY 4.1 7 0 12 0 84.0 ftz 0 0 0.1 0 f 2/10/2021 9:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below \ Space 19 W Exterior Concrete Block- Int Insul FAMILY 4.1 15 0 12 0 180.0 ftz 0 0 0.1 0 20 W Exterior Concrete Block- Int InsuLiVING ROO 4.1 11 0 12 0 132.0 fF 0 0 0.1 0 21 N Exterior Concrete Block- Int Insul DEN 4.1 6 0 10 0 60.0 ftz 0 0 0.1 0 22 S Exterior Concrete Block- Int Insul DEN 4.1 12 0 10 0 120.0 ftz 0 0 0.1 0 23 W Exterior Concrete Block - Int Insul DEN 4.1 15 0 10 0 150.0 ftz 0 0 0.1 0 24 S Exterior Concrete Block- Int InsuMASTER BE 4.1 24 0 11 0 264.0 ftz 0 0 0.1 0 25 S Exterior Concrete Block- Int Insul M W IC 1 4.1 9 0 10 0 90.0 ftz 0 0 0.1 0 26 S Exterior Concrete Block- Int Insul M TOILET 4.1 5 0 10 0 50.0 ftz 0 0 0.1 0 27 N Exterior Concrete Block- Int Insul M BATH 4.1 8 0 10 0 80.0 ftz 0 0 0.1 0 28 NE Exterior Concrete Block- Int Insul M BATH 4.1 5 0 10 0 50.0 ftz 0 0 0.1 0 29 E Exterior Concrete Block - Int Insul M BATH 4.1 8 0 10 0 80.0 ftz 0 0 0.1 0 30 SE Exterior Concrete Block - Int Insul M BATH 4.1 4 3 10 0 42.5 ftz 0 0 0.1 0 31 S Exterior Concrete Block - Int Insul M BATH 4.1 10 0 10 0 100.0 ftz 0 0 0.1 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated LAUNDRY None .17 2 6 8 20 ftz WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ftz 2 ft 0 in i ft 4 in None None 2 E 2 Metal Low-E Single Yes 0.65 0.3 Y 16.0 ftz 14 ft 0 in 1 ft 4 in None None 3 E 2 Metal Low-E Single Yes 0.65 0.3 Y 24.0 ftz 14 ft 0 in 1 ft 4 in None None 4 N 4 Metal Low-E Single Yes 0.65 0.3 Y 6.0 ftz 8 ft 0 in 1 ft4 in None None 5 N 6 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ftz 2 ft 0 in 1 ft 4 in None None 6 N 8 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ftz 2 ft 0 in 1 ft 4 in None None 7 E 10 Metal Low-E Single Yes 0.65 0.3 Y 12.0 ftz 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 8 E 10 Metal Low-E Single Yes 0.65 0.3 Y 30.0 ftz 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 9 S 12 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ftz 18 ft 0 in 1 ft 4 in None None 10 SW 13 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ftz 18 ft 0 in 1 ft 4 in None None 11 W 14 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ftz 18 ft 0 in 1 ft 4 in None None 12 W 15 Metal Law-E Single Yes 0.65 0.3 Y 24.0 ftz 8 ft 0 in 1 ft 4 in None None 13 W 17 Metal Low-E Single Yes 0.65 0.3 Y 6.0 ftz 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 14 W 19 Metal Low-E Single Yes 0.65 0.3 Y 14.6 ftz 10 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 15 W 19 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ftz 10 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 16 W 20 Metal Low-E Single Yes 0.65 0.3 Y 48.0 ftz 24 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 17 W 23 Metal Law-E Single Yes 0.65 0.3 Y 40.0 ftz 14 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 18 S 24 Metal Low-E Single Yes 0.65 0.3 Y 30.0 ftz 2 ft 0 in 1 ft 4 in None None 19 S 26 Metal Low-E Single Yes 0.65 0.3 Y 6.0 ftz 2 ft 0 in 1 ft 4 in None None 20 NE 28 Metal Low-E Single Yes 0.65 0.3 Y 14.2 ftz 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 21 E 29 Metal Low-E Single Yes 0.65 0.3 Y 30.0 ftz 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2/10/2021 9:43 AM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ' WINDOWS Orientation shown is the entered, Proposed orientation. / 1/ # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 22 SE 30 Metal Low-E Single Yes 0.65 0.3 Y 14.2 ftz 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ftz 420 ftz 29 ft loft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000355 3110.2 170.64 320.35 .1031 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 34 kBtu/hr 1 COP:1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts- 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 Single SEER: 16 23.6 kBtu/hr 708 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS # --- Supply--- Location R-Value Area --- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 200 ftz Attic 6 140 ftz Attic Attic 20 ftz Default Leakage Garage (Default) c(Default) c 14 ftz Default Leakage Garage (Default) c(Default) c 1 1 2 2 2/10/2021 9:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FnRM R4M-209171 INPUT SUMMARY CHECKLIST REPORT ' TEMPERATURES Programable Thermostat: N Ceiling Fans: Coding [[ ]] Jan [[ jj Heatin[X] Jan [X] Feb Feb [[ ]] Mar [X] Mar Apr APr r [ ] May ] May Xj Jun ] Jun Jul Jul Rhil [X] Aug ] Au[ [X] Sep ] SeP Oct N f � Oct Nov Nov Dec Dec H Venting[[ ]] Jan [[ ]] Feb [[XXjj Mar A r r ] may ] Jun ] Aug E [ ] Se [ Ort Nov Der, Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 HALLWAY Default(8lbs/sq.ft. ftz ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft? ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz ft 0.3 FAMILY ROOM Default(8 Ibs/sq.ft. ftz ft 0.3 HALL Default(8 ibs/sq.ft. fiz ft 0.3 LAUNDRY ROOM Default(8lbs/sq.ft. ftz ft 0.3 POWDER ROOM Default(8 Ibs/sq.ft. ftz ft 0.3 DINING Default(8 Ibs/sq.ft. f? ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ftz ft 0.3 HER WIC Default(8 Ibs/sq.ft. ft, ft 0.3 HIS CLST Default(8 Ibs/sq.ft. ftz ft 0.3 AHU 2 CLST Default(8 Ibs/sq.ft. ftz ft 0.3 DEN Default(8 Ibs/sq.ft. f? ft 0.3 M TOILET Default(8 Ibs/sq.ft. f? ft 0.3 M BATH Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER 2/10/2021 9:43 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7 2020- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA 9- TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CASTILLO-RODRIGUEZ Builder Name: ALPHA DESIGN CONTRACTOR, LLC. Street: 3707 TANAGER PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE , FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY W x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs, insulated. Electricallphone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/10/2021 9:44 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD rEIT11MA Trl rED rEcC.3f PERrv�cMANCrE 1NDrEXd_ n07 The lower the EnergyPerformance Index, the more efficient the home. 3707 TANAGER PLACE, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2628.50 ft2 b. Frame - Wood, Adjacent R=11.0 314.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 3340.00 ft2 6. Conditioned floor area (ft2) 3340 b. N/A R= ft2 c. N/A R= ftz 7. Windows- Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: S I, U=0.65 g 419.92 ft2 a. Sup: Attic, Ret: Attic, AH: Garage 6 200 SHGC: SHGC=0.30 b. Sup: Attic, Ret: Attic, AH: Garage 6 140 b. U-Facto: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 46.5 SEER:16.00 SHGC: b. Central Unit 23.6 SEER:16.00 d. U-Factor: NIA ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 9.508 ft. b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average SHGC: 0.300 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): NIA ft2 a. Electric EF: 0.98 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 3340.00 ft2 Credits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featu �j' Builder Signature: � cif` w Date: d -711e Address of New Home: �' ��7 ���'��r City/FL Zip: ✓�'� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/10/2021 9:43 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1