Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
Pro ect Summa Job: ,- Wrightsoft® AHU ey FEB. 10, 2021 w QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS a_10L.COM For. SAUL CASTILLO AND RUBICELIA RODRIGUEZ, ALPHA DESIGN CONTRACTOR, LLC. 3707 TANAGER PLACE, FORT PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db - 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23660 Btuh Structure 26423 Btuh Ducts 8611 Btuh Ducts 8984 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh. (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32271 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33637 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4787 Btuh Ducts 3447 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Btuh Area (ftz) 2409 2409 Equipment latent load 8234 Volume (ft3) 27618 27618 Air changes(hour 0.22 0.12 Equipment Total Load (Sen+Lat) 41871 Btuh Equiv. AVF (cfm) 102 55 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NA04800GOBO AHRI ref Coil FX4DNF049L AHRI ref 202025346 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 9.3 kW Sensible cooling 32550 Btuh Heating output Btuh Latent cooling 13950 Btuh Temperature rise19 .31565 OF Total cooling 46500 Btuh Actual airflow 1550 cfm Actual airflow 1550 cfm Airflow factor 0.048 cfm/Btuh Airflow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Pj.t- wright_soft- 2021-Feb-10 09:33:29 '�- Right-Sulte® Universal 2021 21.0.02 RSU08101 age ACCK ...soft WACICASTILLO-RODRIGUEZ W R30 2 10 21.rup Caic = MJ8 Front Door faces: E `� j �Ir � a t g ,-- wrightsoft® Project Summary AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCSQAOL.COM Job: Date: FEB. 10, 2021 By: For. SAUL CASTILLO.AND RUBICELIA RODRIGUEZ, ALPHA DESIGN CONTRACTOR, LLC, 3707 TANAGER PLACE, FORT PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 14701 Btuh Ducts 2664 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 17365 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatin Coolingg Area (ft2) 93q 931 Volume (ft3) 9701 9701 Air changes/hour 0.45 0.24 Equiv. AVF (cfm) 72 39 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflow factor Static pressure Space thermostat 100 EFF 4.5 kW 15295 Btuh 18 0 787 cfm 0.045 cfm/Btuh 1.00 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 14292 Btuh Ducts 3430 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipmenf sensible load 16836 Btuh Latent Cooling Equipment Load Sizing Structure 2210 Btuh Ducts 1010 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3221 Btuh Equipment Total Load (Sen+Lat) 20057 Btuh Req. total capacity at 0.70 SHR 2.0 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond CA16NW02400GOA0 Coil FX4DNF025L AHRI ref 9201324 Efficiency 13.0 EER, 16 SEER Sensible cooling 16520 Btuh Latent cooling 7080 Btuh Total cooling 23600 Btuh Actual air flow 787 cfm Airflow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.85 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlghtsoI 2021-Feb-10 09:33:29 .+ a u,..,,.�,..,�..�. Rlght-Suite® Universal 2021 21.0.02 RSLI08101 Page 2 CK ...sot WACICASTILLO-RODRIGUEZ W R30 2 10 21.rup Cale = MJ8 Front Door faces: E -�- wrightsoft° Right-M Worksheet Job: AHU 1 Date: FEB. 10, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS ,AOL.COM 1 Room narne AHU 1 BEDROOM 2 2 B posed wall 138.0 ft 12.0 ft 3 Room height 11.5 ft 10.0 ft heaticool 4 Room dimensions 14.0 x 12.0 ft 5 Room area 2409.1 ft2 168.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (13tuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Grass WP/S Heat Cool Gross N/P/S Heat Cool 6 1N--G I-3AAocs 2 lazing, drldw-e 2 glaze cir low-e glazing, 0.143 1.010 1.010 n n n 4.00 28.28 28.28 2.19 20.39 20.39 5A 6 45 469 0 . 0 1 1170 170 273 4122 1?2 - 918 120 0 15 100 0 0 420 0 424 230 0 306 G VV t-_ 11 13A-4ocs 2 glazing, clr low-e 0.143 1.010 ne ne 0.00 0.00 0.00 0.0.0 0 0 0 0 0 0 0 0 0 0. 0 _ _ 0 0 0 0 ,0 -C 13AAocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 1.010 1.010 a a a _ _ 4.00 28.28 28.28 2.19 38.33 38.33 349 16 24 261 1 1 1045 452 .679 571 613 920 0 0 0 0 0 0 6 0 0 0 0 0 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, dr lowre 13AAocs 2 glazing, dr low-e 13A-4ocs I 2 glazing, dr low-e 2 glazing,. dr low-e. 13AAocs 2 glazing, dr low-e 1.010 1-010 1.010 0.143 1.010 0.143 1.010 1.010 0.143 1.010 a a a se se w s - s , sw sw 28.28 28.28 0.00 0.00 0.00 4.00 0.00 28.28 4.00 28.28 27.84 " 29.29 .. 0:00 0.00 0.00 '2.19:. 0.00 " . 20.39 2.19 26.47 12 30 0- 0 0 132 0 15 60 15 2 2 D 0 0 117 0 15 45 7 339 848 0 0 0 468 0 424 180 424 334 879 0 0 0 256 0 - 306 98 397 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1N -G -G W L-G 13A4ocs 2 glazing, dr low-e 2 glazing, clr low-e 0.143 1.010 1.010 w w w 4.00 28.28 28.28 2.19 37.82 38.33 488 15 24 365 1 1 1463 424 679 799 567 920 0 0 0 0 0 0 0 0 0 0 6 0 2 glazing, dr low-e 2 glazing, cir low-e 2 glazing, drlow-e 2 glazing, cir low-e 2 glazing, cir low-e .. 16A30ad 1.010 1.010 1.010 1.010 1.010 0.032 w w w w w - 28.28 28.28 28.28 0.00 28.28 0.90 24.60- 25.09 25.09 0.00 _ _ _25.37 2.24 6 15 15 0 48 2408 1 1 1 0 2 2408 170 • 412 424 0 1357 2158 148 366 376 0 1218. 5394 0 0 0 0 _ _. 0 16B 0 0 6 0 0 168 0 0 0 0 0 151 0 0 0 0 0 376 C F 22Atph - _1.358 _ - 38.02 . 0.00 _ 2408 _ 138 5247 -0 -- - 168 - 12 - 456 0 6 c)AED excursion 492 -69 Envelope loss/gain 20515 16721 1451 843 12 a) Infiltration b) Room ventilation 3145 0 903 0 245 0 70 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 8800 600 Subtotal (lines 6 to 13) 23660 26423 1696 1513 Less a#emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 434 455 14 Subtotal 23660 26423 2130 1969 15 Duct loads 36% 34% 8611 8984 36% 34% 775 669 Total room load 32271 35407 2906 2638 Air required (cfm) I 1 1550 1550 1 1 140 115 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -F' 1- wrightsoft^ 2021-Feb-10 09:33:29 t8� Right -Suite® Universal 2021 21.0.02 RSU08101 Page 1 ...soft WAMCASTILLO-RODRIGUEZ W R30 2 10 21.rup Cale = MJ8 Front Door faces: E ♦J O cn W o m O 0 N CO cn T W 02 0 0 0 Er m N m N_ Al v 0 CD -o m N N m Cn A W N 01 I O 01 A co to - oRa, �� nC)� �) ) ��gi� N ° w 0 ) 0 $ Of 2 _ p��-m CL CD y 51 � � . 0 7 p�3 8=' -S p xm (] � Aug3 O u N B CD �NNNNN N.N-+N WIVNWNWNNNNNWNWNN-� 0 fDyfO (G (C (O 0It(aMcocn(occ>co (O (O (O (O c o O. O 01 O O 7" 7 7 O n a00o .a FLPI ni C CGOO,�p O• 00 •07 m �p y 00-ABC,-p00-+0-a+O a+ IU ObOOOOOWOWOOO W OOOOOW OOOW fefE����g�r�mm(D(D CD O wCfOW•NONWNOD�{O��A•OND A,ONDOA000 mW•NW NW?00 �N•ODA _ p •ONO C� r 'S ON-Ul OfpphCppil N'��VO ON,O OOCO pAp��Gw(�DV S A'v StD C00 WNfD V(D (WD O(D SSS(NDAWWc000(WD N N OWj��aa 0 o 55a, 2y25.00cc000000coCoo oc, 00000 3 O 0 CWn W -n o A0000000000000000000�-�0�00000 ? x O (p_p�tNn W(.pp oo�1 N N cN(n�1 c(.n� j ��1a1. cCc7n7�� 4.0000000000000 0000AMOO coo 7-0- 7' 0 0 8 f°a mCD CA00o M rl) coo Off' o�000000000000000000�W200000 � op w 0 0 CDR o 0 SD 0 u o O 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 O 0 o 0 0'O O O o 0 x OZ 2 CD N _ VO .A+N(A00 V OG V OV00000000000000000000000000 O 7�� UtN 01V �WW O 0 0 O N 0 0 0 0 0 0 0 0 0 OO 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G Mi A kb S. Xrol C } CA CD V'h T m O O N - wr5ghtsofr RighW@ Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS _AOL.COM Job: Date: FEB. 10, 2021 By: 1 Room name RATH 3 CLST2 2 E)posed wall 6.0 ft 2.0 ft 3 Room height 10.0 ft heal/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 6.0 ft 7.0 x 2.0 ft 5 Room area 60.0 ft2 14.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (13tuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 WAG' m 4ocs 2 glazing, clr low-e 2 glazing, clr low_-e 0.143 1.010 1.010 n n 'n 4.00 28.28 28.28 219 20.39 20.39 60 6 0 54 0 0 216 170 0 118 122 0 20 0 0 20 6 0 80 0 0 44 0 0 r. 'G VpI 7-G 11 13A4ocs 2 glazing, clr low-e 0.143 1.010 ne ne 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, cir low-e 2 glazing, cir lower 0.143 1.010 1.010 a a a 4.00 28:28 28.28 2.19 38.33 38.33 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 0 0 0 0 2glazing, cir low-e 2 glazing; clr low-e 2 glazing, cir.low-e 13A4ocs 2 glazing, cU low-e_ 13A4ocs 2 glazing, dr low-e 2 glazing, dr low-e 13A4ocs 2 glazing, cir low-e 13A4ocs 2glazing, cir low-e 2giazing, cirlow-e 1.010' 1.010 1.010 0.143 1.010 0.143 1.010 1.010 0.143 1.010 0.143 1.010 1.010 a a a se se s s s sw sw, w w w 28.28 2828 0.00 0.00 0.00 4.00 0.00 28.28 4.00 28.28 4.00 28.28 28.28 27.84 29.29 . 0:00 0.00 0.00 ' 2.19 0.00. 20.39 2.19 25.47 2.19 37.82 38.33 0 0 0 0 0 0 0 0 0 0 0 . 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 0 0 0 0 0 0 0, 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 0 0 0 0 0 0 0 0, 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0' 0 0 W L-- G �( L-G 2 glazing, clrlow-e 2 glazing, dr low-e 2 glazing,, cir low-e 2 glazing, clr low- 2 glazing, clr lower , 16A 30ad 1.010 1.010 1.010 1.010 1.010 0.032 w w w w w - 28.28 28.28 28.28 0.00 .128.28 0.90 24.60 25.09 25.09 - 0.00 . 25.37 2.24 0 0 0 0 , 0 60 0 0 0 0 0 ,. 60 0 0 0 0 0 54 0 0 0 0 0 . CM 0 0 0 0 0 14 0, 0 0 0 0 14 0 0 0 0 0 13 0 0 0 0 0 31 C F 22A-tph . 1.358 - 38.02 0.00 60 6 228 0 _.. 14. 2 _ 76 ._ 0 6 c)AED excursion -18 -4 Envelope loss/gain 668 357 1691 71 12 a) Infiltration 122 35 41 12 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 790 392 209 83 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 118 72 -209 -83 14 Subtotal 908 464 0 0 15 Duct loads 36% 34% 330 158 361/o 34% 0 0 Total room load 1238 6221 0 0 Air required (cfm) 59 27 01 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrfghtsoft- 2021-Feb-10 09:33:29 Right -Suite@ Universal 2021 21.0.02 RSLI08101 Page 3 ...soft HVAC\CASTILLO-RODRIGUEZ W R30 2 10 21.rup Colo = MJ8 Front Door faces: E - - weight;•soft Right-M Worksheet Job: AHU 1 Date: FEB. 10, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 4 BEDROOM 3 2 F)qosed wall 12.0 ft 120 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 13.0 x 12.1 ft 14.0 x 12.0 ft 5 Room area 157.1 ft2 168.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft22F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V !��3G 13A4ocs 2 glazing, clrlow-e 2 glazing, clr low-e 0:143 1.010 1.010 n n n 4.00 28.28 28.28 2.19 20:39 20.39 126 0 15 105 0 0 420 0 424 230. 0 306 120 0 15 105 0 0 420 0 424 230 0 306 V�J L-G 11 13A4ocs 2 glazing, clr low-e 0.143 1.010 ne ne 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 1.010 1.010 a a a 4.00 28.28 28.28 2.19 38.33 38.33 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 1.010 1.010 a a 28.28 28.28 27.84 29.29 '0 0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 13A4ocs 2 glazing, clr low-e 1.010 0.143 1.010 a se se 0.00 0.00 0.00 0.00 0.00 0.00 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 t-G V�J 13A4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr low-e 1.010 s 0.00 0.00 0 0 0 0 0 0 0 0 L�_GG 2 glazing, clr low-e. 13A4ocs 2 glazing, clr low-e 1.010 0.143 1.010 s sw sw 28.28 4.00 28.28 20.39 2.19 26.47 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V)J �-( 13A4ocs 2 glazing, clrlow-e 2 glazing, cir law-e 0.143 1.010 1.010 w w w 4.00 28.28 28.28 2.19 37.82 38.33 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 2 glazing, clrlow-e 2 glazing, clr low-e 1.010 1.010 w w 28.28 28.28 24.60 25.09 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clrlow-e 1.010 1.010 1.010 w w w 28.28 0.00 28.28 25.09 0.00 25.37 0 0 0 0 0 0 0 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 0.90 2.24 156 156 140 349 168 , 168 151 376 F 22A tph 1.358 - 38.02 0.00 156 12 456 0 168 12 456 _ 0 6 c)AED excursion -76 -78 Envelope loss/gain 1441 809 1451 834 12 a) Infiltration 245 70 245 70 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 800 800 Subtotal (lines 6 to 13) 1685 1679 1696 1705 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 112 60 117 71 14 Subtotal 1798 1739 1813 1775 15 Duct loads 36% 34% 654 591 360/6 34% 660 604 Total room load 2452 2330 2473 2379 Air required (cfm) 1 1 118 102 11191 104 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Orl- wrYgF t:g3c Ft- 2021-Feb-10 09:33:29 AS, Right -Suite® Universal 2021 21.0.02 RSU08101 Page 4 soft HVAC\CASTILLO-RODRIGUEZ W R30 2 10 21.rup Cale = MJ8 Front Door faces: E - weightsoft Right-M Worksheet Job: AHU 1 Date: FEB. 10, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 P.00m come HALLIJ`JAY CLST 4 2 Biposed wall 0 ft 2.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 72.0 ft 10.0 x 2.0 ft 5 Room area 72.0 ft2 20.0 ft2 Ty Construction number U-value (Btuh/ftVF) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 W 13A4ocs 2 glazing, cir low-e 2 glazing, dr low-e 0.143 1.010 1.010 n n n 4.00 28.28 28.28 '2.19 2.39 20.39 0 0 0 0 0 0 0 O 0 0 0 0 20 0 0 20 0 0 80 0 0 44 0' 0 I{----GG V� 11 13A4ocs 2 glazing, cir low-e 0.143 1.010 ne ne 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G 13A4ocs 2 glazing, clr low-e 2glazing, clrlow-e 0.143 1.010 1.010 a a a 4.00 28.28 28.28 2.19 38.33 38.33 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _0 0 0 0 2 glazing, cir low-e 2 glazing, cir iow=e 1.016 1.010 a a 28.28 28.28 27.84 29.29 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 .0 UV L-G 2 glazing, ,cir low-e 13A-4ocs 2 glazing, cir low-e 1.010 0.143 1.010 a se se 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1/V 13A-4ocs 2 glazing, cir low-e 0.143 1.010 s s 4.00 0.00 2.19 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 i�CGI �/�1 2 glazing, dr low-e 13A4ocs 2 glazing, dr low-e 1.010 0.143 1.010 s sw sw 28.28 4.00 28.28 _ 20.39 2.19 26.47 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 --C 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 1.010 1.010 w w w 4.00 28.28 28.28 2.19 37.82 38.33 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 2glazing, drlow-e 1.010 1.010 w w 28.28 28.28 24.60 25.09 0 0 0 0 0 0 0 01 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e, 1.010 1.010 1.010 w w w 28.28 0.00 28.28 25.09 0.00 25.37 0 0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16A30ad 0.032 - 0.90 2.24 72 72 65 161 20 20 18 45 F 22A tph . _ 1.358 - 38.02 0.00 72 . 0 0 0 20 2 76 0 6 c)AED excursion -7 -4 Envelope lass/gain 65 154 174 84 12 a) Infiltration 0 0 41 12 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 65 154 215 96 Less eitemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -65 -154 -215 -96 14 Subtotal 0 0 0 0 15 Duct loads 36% 34% 0 0 36% 34% 0 0 Total room load 0 0 0 0 Air required (cfm) 0 0 01 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -iId- wrlghtscxft-� 2021-Feb-1009:33:29 ""'""""'""""""" """"' Right-SulteO Universal 2021 21.0.02 RSU08101 lr�q Page 5 ...soft HVAC\CASTILLO•RODRIGUEZ W R30 2 10 21.rup Cale = MJB Front Door faces: E + wrightsoft Right-J® Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Job: Date: FEB. 10, 2021 By: 1 Room name DINING CLST 3 2 Eng3osed wall 13.0 ft 0 ft 3 Room height 12.7 ft heattcool 10.0 ft heat/cool 4 Room dimensions 1.0 x 277.0 ft 7.0 x 2.0 ft 5 Room area 277.0 ft2 14.0 ft2 Ty Construction number U-value (Stuh/ft2--°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Stuh) Heat I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 I- C 13A4ocs 2 glazing, cir low-e 2 glazing, dr low- 0.143 1.010 1.010 n n n 4.00 28.28 28.28 2.19 20.39 20.39 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 l G y/ 11 13AAocs 2glazing, clrlow-e 0.143 1.010 ne ne 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G 13A4ocs 2glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, dr low-e 0.143 1.010 1.010 1.010 1.010 a a a a a 4.00 28.28 28.28 28.28 28.28 2.19 38.33 38.33 27.84 29.29 165 0 0 12 30 123 0 0 2 2 493 0 0 339 848 269 0 0 334 879 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 t-G 2 glazing, cir low-e 13A4ocs 2 glazing, dr low-e 1.010 0.143 1.010 a se se 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 VJJ II-_C-G 13A4ocs 2 glazing, cir low-e 2glazing, cir low-e 13A4ocs 2 glazing, dr low- 0.143 1.010 1.010 0.143 1.010 s s s sw sw 4.00 0.00 28.28 4.00 28.28 2.19 0.00 20.39 2.19 25.47 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W -G 13A4ocs 2 glazing, cir low-e 2 glazing, cir law-e 0.143 1.010 1.010 w w w 4.00 28.28 28.28 2.19 37.82 38.33 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr low-e 2 glazing, cir low-e 1.010 1.010 w ' w 28.28 28.2E 24.60 25.09 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, .cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 16A,3(bd 1.010 1.010 1.010 0.032 w w w - 28.28 0.00 28.28 0.90 25.09 0.00 25.37 2.24 0 0 0 277 0 0 0 277 0 0 0 248 0 0 0 620 0 0 0 14 0 0 0 14 0 0 0 13 0 0 0 31 C F 22A-tph , 1.358 - 38.02 0.00 277 13 494 0 . _ 14 0 0 0 6 c)AED excursion -117 -1 Fnvelopeloss/gain 2423 1985 13 30 12 a) Infiltrwion 337 97 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 2760 2582 13 30 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 16 -13 -30 14 Subtotal 2766 25981 0 0 15 Duct loads 36% 34% 1007 883 360 34% 0 0 Total room load 3773 3481 0 0 Air required (cfm) 181 152 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�- wrightsoft 2021-Feb-10 09:33:29 p Right -Suite@ Universal 2021 21.0.02 RSLI08101 Page 6 ...soft WAC\CASTILLO-RODRIGUEZ W R30 2 10 21.rup Calc = MJ8 Front Door faces: E ° - wfightsoft Right-M Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS o-10L.GOM Job: Date: FEB. 10, 2021 By: 1 Room name KITCHEN HALL 2 Exposed wall 12.0 ft 5.0 ft 3 Room height 12.0 ft heat/cool 10.0 ft heaticool 4 Room dimensions 1.0 x 436.0 ft 5.0 x 6.0 ft 5 Room area 436.0 ft2 30.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/W--'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NOS Heat Cool 6 13A-4ocs 2 glazing, driow-e 2 glazing, clrlow-e 0.143 1.010 1.010 n n n_ 4.06 28.28 2.19 20:39 '20.39 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0_ 0 0 0 6 0 0 0 0 0 L- CG t/�! YG_ 11 13A4ocs 2 glazing, cir low-e 0.143 1.010 ne ne _2.6.28 0.00 0.00 0.00 0.00 0 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 0 13A4ocs 2 glazing, clrlow-e 0.143 1.010 a a 4.00 28.28 2.19 38.33 .0 _ 0 0_ 0 0 0 0 0 0 0 0 0 0 0 6 0 2 glazing, dr low-e 1.010 a 28.28 38.33 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clrlow-e 1.010 1.010 a a 28.28 28.28 27.84 29.29 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V1J 2 glazing, cir low-e. 13A4ocs 2 glazing, dr low- 1.010 0.143 1.010 a se se 0.00 0.00 0.00 0.00 0.00 0.00 0, 0 0 0 0 0 0 0 0 0._ 0 0 0 0 0 ..._ 0 0 0 0 0 0 0 0 0 -G VIJ 13A4ocs 0.143 s -4.00 2.19 48 33 132 72 0 0 0 0 2 glazing, cir low-e 1.010 s 0.00 0.00 0 0 0 0 0 0 0 0 I�----GG IM �G 2 glazing, cir low-e. _ , .. 13A4ocs 2 glazing, dr low-e 1.010 0.143 1.010 s sw sw 28.28 4.00 28.28 20:39 2.19 26.47 15 60 15 _ 15 45 7 424. 180 424 _ _ 306 98 397 . 0, 0 0 0 0 0 , _ - _ 0 0 0 0: 0 0 13A4acs 2 glazing; cir low-e 2 glazing, drlow-e 6.143 1.010 1.010 w w w 4.00 28.28. 28.28 2.19 37.82 39.33 36 15 0 21 1 0 84 424 0 46 567 0 50 0 24 28 0 1 _ 104 0 679 57 0' 920 2 glazing, cir`low-e 2 glazing, dr low-e 1.010 1.010' w w 28.28 r28.28 24.60 25.09 0 0 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clrlow-e 2 glazing, cir low-e 1.010 1.010 1.010 w w w 28.28 0.00 28.28 25.09 0.00 25.37 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16A30ad 0.032 - 0.90 2.24 436 436 391 977 30 30 27 67 .F 22Atph 1.356 _ - _ _38.02 '0.00 436 12 456 --0: 30 .5 190 . 0 6 c)AED excursion 113 289 Envelope loss/gain 2516 2577 1000 1333 12 a) Infiltration 294 84 102 29 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2560 0 Subtotal (lines 6 to 13) 2809 5161 1102 1362 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 22 521 -1102 -1362 14 Subtotal 2831 5214 0 0 15 Duct loads 36% 34% 1030 1773 36% 34% 0 0 Total room load 3862 6986 0 0 Air required (cfm) 185 306 01 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -opl- wrlgF%tSC*ft- 2021-Feb-10 09:33:29 -49&" Right-Sufte® Universal 2021 21.0.02 RSLJO8101 Page 7 ...soft HVACICASTILLO-RODRIGUEZ W R30 2 10 21.rup Celc = MA Front Door faces: E -f - wrightsoft° Right-M Worksheet Job: AHU 1 Date: FEB. 10, 2021 QUICK CALCS; INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 P.00rn name BATH 2 FAMILY 2 Exposed wall 15.0 ft 22.0 ft 3 Room height 10.0 ft heat/cool 12.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 6.0 ft 54.0 ft2 1.0 x 187.0 ft 187.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Coal 6 V)/ IL--GG 13A4ccs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 1.010 1.010 n n n 4.00 28.28 28.28 2.10 20:39 20.39 60 0 0 60 0 0 240 0 0 131 0 0 6 0 0 0 0 0 0 0 0 0 0 0 V�/ 13A4ocs 0.143 ne 0.'00 0.00 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 1.010 ne 0,00 0.00 0 0 0 0 0 0 0 0 LG 13A-4ocs 2 glazing, clr low-e 0.143 1.010 a a _ 4.00 28.28 2.19 38.33 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 1.010 a 28.28 38.33 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 1.010 1:010 a a 28.28 28.28 27.84 29.29 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V�J 1--G 2 glazing, dr low-e 13A4ocs 2 glazing, cir low-e 1.010 0.143 1.010 a se se 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11N 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 84 84 336 184 It---GG 2 glazing, clr low-e 1.010 s 0.00 0.00 0 0 0 0 0 0 0, 0 Ur! �G 2 glazing, dr low-e 13AAocs 2 glazing, cir low-e 1.010 0.143 1.010 s sw sw 28.28 4.00 28.28 20.39. 2.19 26.47 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13AAocs 2 glazing, cir low-e 2 glazing, dr low-e 0.143 1.010 1.010 w w w 4.00 28.28 28.28 2.19 37.82 38.33 90 0 0 84 0 -0 336 0 0 184 0 0 180 0 0 150 0 0 602 0 0 329 0 0 2 glazing, dr low-e 1.010' w 28.28 24.60 6 1 170 148 0 0 0 0 2 glazing, cir low-e 1.010 w 28.28 25.09 0 0 0 0 15 1 412 366 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 1.010 1.010 1.010 w w w 28.28 0.00 28.28 25.09 0.00 25.37 0 0 0 0 0 0 0 0 0 0 0 0 15 0 0 1 0 0 424 0 0 376 0 0 C 16A30ad 0.032 - 0.90 2.24 54 54 48 121 187 187 168 419 F 22Artph 1.358 - 38.02 0.00 54 15 570 0 187 22 837 0 61 c)AED excursion 44 262 Envelope loss/gain 1365 627 2779 1936 12 a) Infiltration 306 88 538 154 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1671 715 3317 2090 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 389 481 389 481 14 Subtotal 2060 1196 3706 2571 15 Duct loads 36% 34% 750 407 36% 34% 1349 874 Total room load 2809 1602 5055 3445 Air required (cfm) 135 70 1 243 151 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -PW wrightott^ 2021-Feb-10 09:33:29 "sRight-Sulte6f Universal 2021 211&61.0.02 RSU08101 page 8 ...soft WVAC\CASTILLO-RODRIGUEZ W R30 2 10 21.rup Cate = MJ8 Front Door faces: E - wifightsoft Right-J® Worksheet Job: AHU 1 Date: FEB. 10, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LIVING ROOT.". 2 Exposed wall 11.0 ft 3 Room height 12.0 ft heat/cool 4 Room dimensions 14.0 x 21.0 ft 5 Room area 294.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area Load number (Btuhlft= °F) (Btuh/ft') or perimeter (ft) (Btuh) I or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 1.010 1.010 n in n 4.00 28.28 28.28 2.19 20.39 0 0 0 0 0 0 0 0 0 0 0 0 W 11 13AAocs 2 glazing, clr low-e 0.143 1.010 ne ne 0.00 0.00 _20.39 0.00 _ 0.00 0 0 0 . 0 0 0 0 0 13A4ocs 2 glazing, dr low-e 0.143 1.010 a a 4.00 28.28 2.19 38.33 0 0 0 0 0 0 0 0 2 glazing, cir low-e 1.010 a 28.28 38.33 .0 0 0 0 2 glazing, clrlow-e 1.010 a 28.28 27.84 _ 0 0 0 0 2 glazing, clr low-e 1.010 e' 28.28 29.29 .0 0 0 0 2 glazing, clr low-e 13A4ocs 2 glazing, dr low-e 1.010 0.143 1.010 a se se 0.00 0.00 0.00 0.00 0.00 0.00 . 0 0 0 0 0 0 0 0 0 -0 0 0 V)J -G 13A-4ocs 2 glazing, clr low-e 6.143 1.010 s s 4.00 0.00 _ 2.19 0.00 0 0 0 0 _0 0 -0 0 Val G 2 glazing, Or low-e ,_ 13A4ocs 2 glazing, dr low-e - _ 1.010 0.143 1.010 -s sw sw 28.28 4.00 28.28 20.39'. 2.19 26.47 0 0 0 -0 0 0 0 0 0 - 0 0 0 - 13A-0ors 2 glazing, clriow-e 2 glazing, dr low-e 0.143 I.010 1.010 w w w 4.00 28.28. 28:28 219 37.82 38.33 132 0 0 84 0 0 336 0 - 0 184 0 0 2 glazing, dr low-e 2 glazing, cirlow-e 1.010 1.010 w w 28.28 28.28 24.60. 25.09 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clriow-e 2 glazing; cirlow-e 1.010 1.010 1.010 w w _ w 28.28 0.00 28,28 .25.09 0.00 . 25.37 0 0 48 0 0 2 0 0 1357 0 0 1218 C 160.30ad 0.0M - 0.90 . 2.24 294 294 263 _ 659 _ F 22,44ph _ _ 1.358 - - 38.02 0.00 294 11 418 - - - 0:. _ 6 c)AED excursion 427 Envelope loss/gain 2375 2487 12 a) Infiltration 269 77 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 400 Subtotal (lines 6 to 13) 2645 2964 Less eAemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2645 2964 15 Duct loads 36% 34% 962 1008 Total room load 3607 3972 Air required (cfm) 1 173 174 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -I*F- wrlgFftSCwt- 2021-Feb-10 09:33:29 A& Right -Suite® Universal 2021 21.0.02 RSLI08101 Page 9 soft WACICASTILLO-RODRIGUEZ W R30 2 10 21.rup Calc = MJ8 Front Door faces: E 4F wfighttsoft° Right-M Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: FEB. 10, 2021 By- 1 Room name HU 2 DEN 2 Exposed wail 106.2 ft $3.0 ft 3 Room height 10.4 ft 10.0 ft heat/cool 4 Room dimensions 1.0 x 176.0 ft 5 Room area 930.5 ft2 176.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Lead number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross WP/S Heat Cool 6 13Adocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 1.010 1.010 n n n 4.00 0.00 0.00 2.19 0.00 ' 0.00 140 0 0 140 0 0 561 0 0 366 0 0 66 0 0 60 0 0 240 0 0 131 0 0 V�/ 11 13A-0ocs 2 glazing, cir low-e 0.143 1.010 ne ' ne_ 4.00 28.28 2.19 21.90 56 14 36 0 '143 401 A 310 0 0 0 0 0 0 0 ---G 13A4ocs 2 glazing, cir low-e 0.143 1.010 a a 4.00 0.00 _ 2.19 0.00 80 0 50 0 _ 260 0 109 0 0 0 _ 0 0 G 0 0 0 2 glazing, cir low-e 1.010 'e 0.00, 0.00 0 0 0 0 0 0 0 0 2 glazing, clriow-e 2 glazing, cir low-e 1.010 1.010 a a 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 W G, 2 glazing, cir low-e . 13A4ocs 2 glazing, dr low-e 1.010 0.143 1.010 a se se 28.28 4.00 28.28 . 25.09 2.19 18.94 30 42 14 2 28 7 _ 848 113 401 , 753 62 268 _ 0 0 0 0 0 0 0 0 0 0. 0 0 Vr! 13A4ocs 2 glazing, clr low-e 0.143 1.010 s s 4.00 2828 2.19 20.39 624 6 588 6 2354 170 1286 122 120 0 120 0 480 0 263 0 Wi L--G 2 glazing, dr low-e 13A4ocs 2 glazing, dr low-e -. 1.010. 0.143 1.010 -s sw sw 28.28 0.00 0.00 20.39 0.00 0.00 30 0 0 . 30 0 0 848 0 0 _ 612 0 0 0 0 0 .0. 0 0 0 0 0 0 0 0 13A4ocs 2 glazing; cir low-e 2glazing, clriow-e 0.143 1.010 1.010 'w w w 4.00 0.00 .0.00 2.19 0.00 0:00 150 0 0 110 0 0 440 0 0 240 0 0 150 0 0 110 0 0' 440 0 0 240 0 0 2 glazing, cir low-e 2 glazing, cir low-e 1.010 1.010 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low- 2 glazing, cir low- 2glazing,_clrlow- 1.010 1.010 1.010 w w w 0.00 28.28 0.00 0.00 25.28 0.00 0 40 0 0 2 0 0 1137 0 0 1016 0 0' 40 0 0 2 0 0 1137 0 0 1016 0 C _ 16A30ad 0.032 - 0.90 2.24 931 931 '834 2084 ..- 176 176 158 394 F 22A tph - _ .1.358 - 38.02 0.00 .931 _106 4037 0 . 176, 33 1255 - - 0 6 c)AED excursion 8 373 Envelope loss/gain 12487 7257 3710 2418 12 a) inf-iltration 2214 635 673 193 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 .0 Appliances/other 6400 500 Subtotal (lines 6 to 13) 14701 14292 4382 3111 Less eAernal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14701 14292 4382 3111 15 Duct loads 18% 24% 2664 3430 180/0 24%1 794 747 Total room load 17365 17722 5176 1 3858 Air required (cfm) 1 1 787 787 235 171 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -AFW wrlgFr tsc ft- 2021-Feb-10 09:33:29 wa.,°••, ,,,- Right•Suite® Universal 2021 21.0.02 RSU08101 Page 10 soft WACICASTILLO-RODRIGUEZ W R30 2 10 21.rup Calc = MJ8 Front Door faces: E J -�- wtightsoft Right-M WorksHeet Job: AHU 2 Date: FEB. 10, 2021 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BEDP.00M M Wic 1 2 E)posed wall 24.0 ft 9.0 ft 3 Room height 11.0 ft heat/cool 10.0 ft heat1cool 4 Room dimensions 1.0 x 396.0 ft 6.0 x 9.0 ft 5 Room area 396.0 ft2 54.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/W) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross MRS Heat Cool 6 13A4ocs 2 glazing, c{r low-e 2 glazing, cir low-e 0.143 1.010 1.010 n n n 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 L-GG VN L--G 11 13A4ocs 2 glazing, clr low-e 0.143 1.010 ne ne 4.00 28.28 2.19 21.90 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13"ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 1.010 1.010 a a a 4.00 0.00 0.001 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 1.010 1.010 a a 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 UrJ G 2 glazing, clr low-e 13A4ocs 2 glazing, clr low-e 1,010 0.143 1.010 a se se 28.28 4.00 28.28 25.09 2.19 18.94 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 V1J 13A4ocs 0.193 s 4.00 2.19 264 234 937 512 90 90 360 197 2 glazing, clr low-e 1.010 s 28.28 20.39 0 0 0 0 0 0 0 0 II-_G-G W t-G 2 glazing, clr low-e 13AAocs 2 glazing, clr low-e 1.010 0.143 1.610 s sw sw 28.28 0.00 0.00 2D.39 0.00 0.00 30 0 0 30 0 0 848 0 0 612 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13AAocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 1.010 1.010 w w w 4.00 0.00 0.00 2-19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e 1.010 1.010 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clrlow-e 1.010 1.010 1.010 w w w 0.00 28.28 0.00 0.00 25.28 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 „ C 96AMad 0.032 - 0.90 2.24. 396 396 355 887 54 54 48 121 F 22A-tph 1.358 - 38.02 .0.00 396 24 _ 913 0 . 54 9 342 0 6 c)AED excursion -179 -43 Envelope loss/gain 3053 1832 751 275 12 a) Infiltration 538 154 183 53 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Applianceslother 3500 iG00 Subtotal (lines 6 to 13) 3591 5486 934 1327 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0, 14 Subtotal 3591 5486 934 1327 15 Duct loads 18% 24% 651 1317 18% 24% 169 319 Total room load 4242 6803 1104 1646 Air required (cfm) 192 302 50 73 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Ad- wrigFftsoTt- 2021-Feb-10 09:33:29 A- "'"'""'° Right-Sulte® Universal 2021 21.0.02 RSU08101 Page 11 ...soft HVAC\CASTILLO-RODRIGUEZ W R30 2 10 21.rup Calc = MJ8 Front Door faces: E wtightsoft° Right-M Worksheet Job: AHU 2 Date: FEB. 70, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name h" WIC 2 M To!L,--T 2 Exposed wall 0 ft 5.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 5.0 x 9.0 ft 6.0 x 5.0 ft 5 Room area 45.0 ftz 30.0 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ftz °F) (Btuh/ftz) or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 2 glazing, cir low-e 2,glazing, clrlow-e 0.143 1.010 1.010 n n n 4.00 0.00 0.00 2.19 0:00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 L-.--G V�J 11 13A4ocs 2 glazing, cir low- 0.143 1.010 ne ne 4.00 28.28 2.19 21.90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A4ocs 2glazing, clrlow-e 2 glazing, clr low-e 6.143 1.010 1.010 a a a 4.00 0.00 0:00 _ 2.19 0.00 0.00 0 0 0 .0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 1.010 1.010 a a 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W T-G 2 glazing, crlow-e 13A-4ocs 2 glazing, c!r low-e 1.010 0.143 1.010 a se se 28.28 4.00 28.28 25.09 2.19 18.94 0 0 0 0_ 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V�/ 13A-4ocs 2 glazing, clr low-e 0.143 1.010 s s 4.00 28:28 ' 2.19 : 20.39 0 0 0 0 0 0 0 0 50 6 44 6 176 170 96 122 l� VI! 2glazing,.clrlow-e Mallocs 2 glazing, cIr low-e 1.010 0.143 1.010 s sw sw 28.28 0.00 0.00 20.39 0.00 0.00 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G 13A4ocs 2 glazing, c!r low-e 2 glazing, cir low-e 0.143 1.010 1.010 w w w 4.00 0.00 .0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cIr low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 1.010 1.010 1.010 1.010 1.010 w w w w w 0.00 0.00 0.00 28.28 0.00 0.00 0.00 0.00 25.28 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 C 16A,30ad • 0.032 - 0.90 2.24 45 45 40 101 30, 30 27 67 F 22A-tph 1.358 - 38.02 .0.00 45 _ 0 0 0 30 5 190 0 6 c)AED excursion -35 -16 Envelope loss/gain 40 66 563 270 12 a) Infiltration 0 0 102 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appiiancesiother 1000 200 Subtotal (lines 6 to 13) 40 1066 665 499 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 40 1066 665 499 15 Duct loads 18% 24% 7 256 18% 24% 120 120 Total room load T48 1322 785 618 Air required (cfm) 2 59 36 27 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -fW wr-10t2tsoft- 2021-Feb-10 09:33:29 A!ffk.-1 Right -Suite® Un!verse1 2021 21.0.02 RSU08101 Page 12 ...soft WAG\CASTILLO-RODRIGUEZ W R30 2 10 21.rup Calc = M.18 Front Door laces: E -F - wtightsoft° Right-J® Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Job: Date: FEB. 10, 2021 By: 1 Room name M BATH 2 EVosed wall 35.2 ft 3 Room height 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 229.5 ft 229.5 ftz Ty Construction LI-value Or HTM Area (ft2) Load Area Load number (Btuh/W °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 V)I 13A-0acs 2 glazing, drlow a 2 glazing, cir low-e 0.143 1.010 1.010 n n n 4.00 0.00 0.00 ' 2.19 0.00 0.00 80 0 0 80 0 0 320 0 0 175 0 0 11-_CG, V�/ I G 11 13A-4ocs 2 glazing, clr low-e 0.143 1.010 ne ne 4.00 28.28 2.19 21.90 50 14 36 0 143 401 76 310 13A4ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 1.010 1.010 a a a 4.00 0.00 0.00 _ 2.19 0.00 0:00 80 0 0 50 0 0 200 0 0 109 0 0 2 glazing; clr Iow-e 2 glazing, clr low-e 1.010 1.010 a a 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 Wi T Ga 2 glazing, clr low-e 13A4ocs 2 glazing, dr low-e 1.010 0.143 1.010 a se se 28.28 4.00 28.28 25.09 2.19 18.94 30 42 14 2 28 7 848 113 401 753 62 268 V+! 13A4ocs 2 glazing, dr low-e 0.143 1.010 s s 4.00 28.28 2.19 20.39 100 0 100 0 400 0 219 0 II _-�G y! �-L 2 glazing, dr low-e 13A�tocs 2 glazing, cir low-e 1.010 0.143 1.010 s sw sw 28.28 0.00 0.00 20.39 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 M41ocs 2 glazing, cir low-e 2 glazing, clr low-e 0.143 1.010 1.010 w w w 4.00 0.00, 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr low-e 2 glazing, dr low-e 1.010 1.010 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr low-e 2 glazing, cir low-e 1.010 1.010 w w 0.00 28.28 0.00 25.28 0 0 0 0 0 0 0 0 2 glazing, cir low-e 1.010 w 0.00 .. 0.00 0 0 0 0 C 16A 30ad 0.032 - 0.90 2.24 230 230 206 514 F 22A4ph 1.358 - 38.02 _0.00 230 35 1337 0 6 c)AED excursion -92 Envelope loss/gain 4370 2397 12 a) Infiltration 718 206 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 200 Subtotal (lines 6 to 13) 5088 2803 Less e#emal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 508E 2803 15 Duct loads 18% 24% 922 673 Total room load 6010 3476 Air required (cfm) 1 272 154 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed, wr1"1MTsoft- 2021-Feb-10 09:33:29 "" "` Rlght-Suite® Universal 2021 21.0.02 RSU08101 Page 13 soft HVACICASTILLO-RODRIGUEZ W R30 2 10 21.rup Calc = MJ8 Front Door laces: E :-�+ wrightsoft° Duct System Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOLCOM Job: Date: FEB. 10, 2021 By: For: SAUL CASTILLOAND RUBICELIA RODRIGUEZ, ALPHA DESIGN CONTRACTOR, LLC. 3707 TANAGER PLACE, FORT PIERCE, FL Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual airflow 1550 cfm 1550 cfm Total effective length (TEL) 210 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 2809 135 70 1.000 6.0 Ox 0 VIFx 53.0 155.0 st5 BATH 3 h 1238 59 27 1.000 5.0 Ox 0 VIFx 22.6 115.0 st1 BEDROOM 2 h 2906 140 115 1.000 7.0 Ox0 VIFx 51.0 155.0 st5 BEDROOM h 2473 119 104 1.000 7.0 Ox0 VIFx 34.9 135.0 st4 BEDROOM h 2452 118 102 1.000 7.0 Ox0 VIFx 19.8 115.0 st1 DINING h 3773 181 152 1.000 7.0 Ox0 VIFx 24.7 115.0 st1 FAMILY h 5055 243 151 1.000 8.0 Ox0 VIFx 54.8 155.0 st5 FOYER c 3347 95 147 1.000 7.0 Ox0 VIFx 38.0 115.0 st2 FOYER -A c 3347 95 147 1.000 7.0 Ox 0 VIFx 44.4 115.0 st2 KITCHEN c 3493 93 153 1.000 8.0 Ox0 VIFx 39.7 135.0 st4 KITCHEN -A c 3493 93 153 1.000 8.0 Ox 0 VIFx 38.3 135.0 st4 LAUNDRY c 1256 7 55 1.000 6.0 Ox0 VIFx 19.8 115.0 st1 LIVING ROOM c 3972 173 174 1.000 8.0 Ox0 VIFx 47.0 115.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 517 336 1.000 948 10.0 0 x 0 VinlFlx st4 st4 Peak AVF 822 745 1.000 768 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1187 1083 1.000 850 16.0 0 x 0 VinlFlx st2 Peak AVF 363 467 1.000 594 12.0 0 x 0 VinlFlx wrightsoft°° 2021-Feb-10 09:33:39 . .µ�•••a��-.,v,ti-�••� Right -Suite® Universal 2021 21.0.02 RSU08101 Page 1 '� ...soft HVACICASTILLO-RODRIGUEZ W R30 2 10 21.rup Cale = MJ8 Front Door faces: E Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat[ Trunk rb2 Ox0 1550 1550 0 0 0 0 Ox 0 V[Fx wrightsoft- 2021-Feb-10 09:33:39 AWARlghtSultaO Universal 2021 21.0.02 RSUD8101 Page 2 ...soft WACICASTILLO-RODRIGUEZ W R30 2 10 21.rup Cale = MJ8 Front Door faces: E