Loading...
HomeMy WebLinkAboutIN PLACE DENSITY TEST REPORTUES Project No: Workorder No: Report Date: 3360.1700014.0000 265211-1 03/31/2022 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:Doyle Masonry, Inc.UES Technician:Mark Rogers P.O. Box 12339 Fort Pierce, FL 34979-2339 Date Tested:03/29/2022 Project:Doyle Masony, Inc. Various Locations, TBD County, FL Type of Test: Area Tested:2701 Industrial Ave 3, Ft Pierce - Silo Foundation Pad Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Final Grade The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Northeast corner of pad 0-1 ft 117.1 10.3 115.4 9.8 99 Pass 2 Southwest corner of pad 0-1 ft 117.1 10.3 115.0 9.9 98 Pass 3 Center of pad 0-1 ft 117.1 10.3 114.6 10.0 98 Pass Remarks:Permit: SLC 2202-0368 Reviewed By GFA International, Inc FBPE Registry No.4930 Alex Albandoz, P.E. STATE OF FLORIDA Professional Engineer No. 92555 This item has been digitally signed and sealed by Alex Albandoz, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1