HomeMy WebLinkAboutIN PLACE DENSITY TEST REPORTUES Project No:
Workorder No:
Report Date:
3360.1700014.0000
265211-1
03/31/2022
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:Doyle Masonry, Inc.UES Technician:Mark Rogers
P.O. Box 12339
Fort Pierce, FL 34979-2339
Date Tested:03/29/2022
Project:Doyle Masony, Inc.
Various Locations, TBD County, FL
Type of Test:
Area Tested:2701 Industrial Ave 3, Ft Pierce - Silo
Foundation Pad
Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Northeast corner of pad 0-1 ft 117.1 10.3 115.4 9.8 99 Pass
2 Southwest corner of pad 0-1 ft 117.1 10.3 115.0 9.9 98 Pass
3 Center of pad 0-1 ft 117.1 10.3 114.6 10.0 98 Pass
Remarks:Permit: SLC 2202-0368
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Alex Albandoz, P.E.
STATE OF FLORIDA
Professional Engineer No. 92555
This item has been digitally signed and sealed by Alex Albandoz,
P.E. on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1