HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method RECEIVED Project Name: Linden Residence Builder Name: FEB 2 5 ZOZZ Street: 2411 Atlantic Beach Boulevard Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34949 Permit Number: St. Lucie County Owner: Linden Residence Design Location: FL, Fort Pierce Jurisdiction: St. Lucie County permij�ting County: St Lucie (Florida Climate Zone ) 1. New construction or existing New (From Plans) 10. Wall Type01778.1 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1544.80 ft2 b. Frame - Wood, Adjacent R=11.0 233.33 ft2 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 11. Ceiling Types (1544.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1544.00 ft2 6. Conditioned floor area above grade (111:2) 1544 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(217.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ftz 6 80 a. U-Factor. Sgl, U=0.65 217.00 ft2 SHGC: SHGC=0.25 b. U-Factor: NIA ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.889 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1544.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1544.00 ft2 b. Conservation features b. N/A R= ftz None c. NIA R= ft2 16. Credits CF. Pstat Glass/Floor Area: 0.141 Total Proposed Modified Loads: 55.30 PASS Total Baseline Loads: 56.92 1 hereby certify that the plans and specifications covered by Review of the plans and Ike -HE SrAl, this calculation are in compliance with the Florida Energy specifications covered by this ��' 'EE_ Code. calculation indicates compliance -Z y sir, , with the Florida Energy Code. 16.+rn,,•, -'=A.°;:�.�� „ PREPARED BY: DATE: 10-7-90191 Before construction is completed this building will be inspected for ,. tv 0 k'1 � n � compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 1,1, with the Florida Energ /Z�� CDD WE OWNER/AG NT• BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report co rg eQ"� Ito outdoors, tested in accordance with ANSI/RESNETRCC 380, is not greater than 0.030 On for whol e MM 10/6/2021 8.47 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHF-CKL15T KEPUKT PROJECT Title: Linden Residence Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1544 Lot # Owner Name: Linden Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 2411 Atlantic Beach Bo Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34949 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1544 15948.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 4 168 1579.2 No 0 1 1 Yes Yes Yes 2 Bath 2 60 564 No 0 1 Yes Yes Yes 3 Bedroom 3 142 1334.8 No 0 1 1 Yes Yes Yes 4 Bedroom 2 166 1560.4 No 0 1 1 Yes Yes Yes 5 Hall 48 451.2 No 0 1 No Yes Yes 6 Great Room 285 3334.5 No 0 1 Yes Yes Yes 7 Dining 96 1113.6 No 0 1 Yes Yes Yes 8 Kitchen 156 1809.6 Yes 0 1 Yes Yes Yes 9 Master Bedroom 225 2340 No 0 1 1 Yes Yes Yes 10 Master Bath 100 940 No 0 1 Yes Yes Yes 11 M WIC 1 25 235 No 0 1 No Yes Yes 12 M WIC 2 25 235 No 0 1 Yes Yes Yes 13 Laundry 48 451.2 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 4 26 ft 168 ft2 __ 1 0 0 2 Slab -On -Grade Edge Insulatio Bath 2 6 ft 60 ft' ___ 1 0 0 3 Slab -On -Grade Edge Insulatio Bedroom 3 25 ft 142 ft' 1 0 0 4 Slab -On -Grade Edge Insulatio Bedroom 2 27 ft 166 ft' __ 1 0 0 10/6/2021 8:47 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R41715-202171 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type F- Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio Hall 1 ft 48 ft2 ___ 1 0 0 6 Slab -On -Grade Edge Insulatio Great Room 15 ft 285 ft2 __ 1 0 0 7 Slab -On -Grade Edge Insulatio Dining 12 ft 96 ft2 __ 1 0 0 8 Slab -On -Grade Edge Insulatio Kitchen 4 ft 156 ft2 __ 1 0 0 9 Slab -On -Grade Edge Insulatio Master Bedroom 30 ft 225 ft2 __ 1 0 0 10SIab-On-Grade Edge Insulatio Master Bath 5 ft 100 ft2 1 0 0 11Slab-On-Grade Edge Insulatio M WIC 1 1 ft 25 ft2 __ 1 0 0 12SIab-On-Grade Edge Insulatio M WIC 2 5 ft 25 ft2 __ 1 0 0 13SIab-On-Grade Edge Insulatio Laundry 6 ft 48 ft2 ___ 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1673 ft2 0 ft2 Light N 0.6 No 0.9 No 20 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1544 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Bedroom 4 0 Blown 168 ft2 0.1 Wood 2 Under Attic (Unvented) Bath 2 0 Blown 60 ft2 0.1 Wood 3 Under Attic (Unvented) Bedroom 3 0 Blown 142 ft2 0.1 Wood 4 Under Attic (Unvented) Bedroom 2 0 Blown 166 ft2 0.1 • Wood 5 Under Attic (Unvented) Hall 0 Blown 48 ft2 0.1 Wood 6 Under Attic (Unvented) Great Room 0 Blown 285 ft2 0 Wood 7 Under Attic (Unvented) Dining 0 Blown 96 ft2 0 Wood 8 Under Attic (Unvented) Kitchen 0 Blown 156 ft2 0 Wood 9 Under Attic (Unvented) Master Bedroom 0 Blown 225 ft2 0.1 Wood 10 Under Attic (Unvented) Master Bath 0 Blown 100 ft2 0.1 Wood 11 Under Attic (Unvented) M WIC 1 0 Blown 25 ft2 0.1 Wood 12 Under Attic (Unvented) M WIC 2 0 Blown 25 ft2 0.1 Wood 13 Under Attic (Unvented) Laundry 0 Blown 48 ft2 0.1 Wood 10/6/2021 8:47 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 SE Exterior Concrete Block - Int InsuBedroom 4 4.1 12 0 9 5 113.0 ft' 0 0 0.5 0 2 SW Exterior Concrete Block - Int InsuBedroom 4 4.1 14 0 9 5 131.8 ft' 0 0 0.5 0 3 SE Exterior Concrete Block - Int Insul Bath 2 4.1 6 0 9 5 56.5 ft' 0 0 0.5 0 4 NE Exterior Concrete Block - Int InsuBedroom 3 4.1 12 0 9 5 113.0 ft' 0 0 0.5 0 5 SE Exterior Concrete Block - Int InsuBedroom 3 4.1 13 0 9 5 122.4 ft' 0 0 0.5 0 6 NE Exterior Concrete Block - Int InsuBedroom 2 4.1 17 0 9 5 160.1 ft' 0 0 0.5 0 7 NW Exterior Concrete Block - Int InsuBedroom 2 4.1 10 0 9 5 94.2 ft' 0 0 0.5 0 8 SW Exterior Concrete Block - Int Insd9reat Room 4.1 12 1 11 8 141.0 ft' 0 0 0.5 0 _ 9 SW Exterior Concrete Block - Int Insul Dining 4.1 9 8 11 7 112.0 W 0 0 0.5 0 10 NE Exterior Concrete Block - Int Insul Kitchen 4.1 3 3 11 7 37.6 ft' 0 0 0.5 0 11 SW Exterior Concrete Block - Int InsMaster Bedro 4.1 15 0 10 5 156.3 ft' 0 0 0.5 0 12 NW Exterior Concrete Block - Int InsMaster Bedro 4.1 15 0 10 5 156.3 ft' 0 0 0.5 0 13 NW Exterior Concrete Block - Int InsWaster Bath 4.1 5 0 9 5 47.1 ft' 0 0 0.5 0 14 NW Exterior Concrete Block - Int Insul M WIC 2 4.1 5 0 9 5 47.1 ft' 0 0 0.5 0 _ 15 SE Exterior Concrete Block - Int Insul Laundry 4.1 6 0 9 5 56.5 ft' 0 0 0.5 0 _ 16 NE Garage Frame - Wood M WIC 2 11 5 9 4 46.7 ft' 0.23 0.5 0 _ 17 NE Garage Frame - Wood Master Bath 11 5 9 4 46.7 ft' 0.23 0.5 0 _ 18 NE Garage Frame - Wood M WIC 1 11 5 9 4 46.7 ft' 0.23 0.6 0 19 N Garage Frame - Wood Laundry 11 2 9 4 18.7 ft' 0.23 0.5 0 _20 NE Garage Frame - Wood Laundry 11 8 9 4 74.7 ft' 0.23 0.5 0 DOORS # Omt Door Type Space Storms LI-Value Width Height Area Ft In Ft In 1 NE Insulated Kitchen None .39 3 6 10 20.5 ft' 2 NE Insulated Laundry None .39 2 8 6 8 17.8 ft' WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft' 2 ft 0 in 1 ft 4 in None None 2 SW 2 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft' 2 ft 0 in 1 ft 4 in None None 3 NE 4 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft' 2 ft 0 In 1 ft 4 in None None 4 SE 5 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft' 2 ft 0 in 1 ft 4 In None None 5 NE 6 Metal Low-E Single Yes 0.65 0.26 Y 15.0 ft' 2 ft 0 in 1 ft 4 in None None 6 SW 8 Metal Low E Single Yes 0.65 0.25 Y 30.0 ft' 2 ft 0 in 1 ft 4 in None None 7 SW 9 Metal Low-E Single Yes 0.65 0.25 Y 41.0 ft' 12 ft 0 in 1 ft 4 in None None 8 SW 11 Metal Low-E Single Yes 0.65 0.25 Y 41.0 ft' 2 ft 0 in 1 ft 4 in None None 9 NW 12 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft' 2 ft 0 in 1 ft 4 in None None 10/6/2021 8:47 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 460 ftz 460 ftZ 25 ft 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000394 1594.8 87.5 164.27 .1199 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 24 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS v # — Supply — Location R Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 80 ft2 Attic 20 ft' Prop. Leak.Free Garage — cfm 46.3 cfm 0.03_ 0.50 1 1 10/6/2021 8.47 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: ling Jan Feb Ven Heating Feb Mar Mar Apr Apr May May Jun Jul (X� [ ] Aug JIS Sp Oct Nov Nov Dee Dec Jan C Jun [[[ ]]] Jul [ l Aug Sep ( Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Bedroom 4 Default(8 Ibs/sq.fL ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.fL ft2 ft 0.3 Hail Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.fL ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC 1 Default(8lbs/sq.ft. ft2 ft 0.3 M WIC 2 Default(8 Ibs/s .ft. ft2 ft 0.3 Laundry 10/6/2021 8:47 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 2411 Atlantic Beach Boulevard, Fort Pierce, FL, 34949 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor. Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor. N/A SHGC: c. U-Factor. N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): NIA New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1544.80 ft2 b. Frame - Wood, Adjacent R=11.0 233.33 ft2 1 c. WA R= ft2 4 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area No a. Roof Deck (Unvented) R=20.0 1544.00 ft2 1544 b. N/A R= ft2 c. N/A R= ft2 Area Ducts, location & insulation level R ft2 217.00 ft2 a. Sup: Attic, Ret: Attic, AH: Garage a. 6 80 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 24.0 SEER:16.00 ft2 3.889 ft. 0.250 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1544.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Co34 compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: AVj 317 kBtu/hr Efficiency 17.0 COP:1.00 Cap: 50 gallons EF: 0.95 CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/6/2021 8:47 PM 7.0.00 - FIeRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Linden Residence Builder Name: Street: 2411 Atlantic Beach Boulevard Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34949 Permit Number: Y U Owner: Linden Residence Jurisdiction: St. Lucie County w x Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided Instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walli i. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall AYtPnfJ behind piping and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or callings. a. In addition, Inspection of log walls shall be in accordance with the provisions of IGC;-4Uo. 10/6/2021 8:48 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1