Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
,-'* e Pro ect Summary Job: Wr1ghtsoftDate: Ente House Quick Calcs, Inc. 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com Project Information For: Linden Residence 2411 Atlantic Beach Boulevard, Fort Pierce, FL 34949 RECEIVED Notes: FEB B 5 2022 St. Lucie County Permitting Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 24632 Btuh Ducts 2467 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 27099 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) - 1544 1544 Volume (ft3) 15948 15948 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 101 53 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.4 kW 25235 Btuh 29 0 800 cfm 0.030 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 19609 Btuh Ducts 1672 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Rate/swing multiplier n 0.95 Equipment sensible load 20217 Btuh Latent Cooling Equipment Load Sizing Structure 2421 Btuh Ducts 1277 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3698 Btuh Equipment Total Load (Sen+Lat) 23915 Btuh Req. total capacity at 0.70 SHR 2.4 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN Cond GSX16S241A Coil ASPT351314A AHRI ref 20 95eOn0FR, Efficiency16 SEER Sensible coon 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.038 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Orl- wrlg6tzsoft"' 2021-Oct-07 07:45:44 la.z RightSulte® Universal 2021 21.0.08 RSU08101 Page 1 Ar--C;A ...1Documents\Wrightsoft HVAC1Linden Residence.rup Calc = MJ8 Front Door faces: NE -�- wrightsoft® Right-M Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 Room name Entire House Bedroom 4 2 Exposed wall 161.0 ft 26.0 ft 3 Room height 10.3 ft 9.4 ft heat/cool 4 Room dimensions 14.0 x 12.0 ft 5 Room area 1544.0 ff= 168.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) I Load I number (Btuh/ft2= (Btuhfft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yl - 13A-flocs 0.143 ne 4.00 2.19 310 - 260 - 1040 568 0 0 - 0 0 IA-rlom 1.270 ne 35.56 4103 30 0 1067 1291 0 0 0 0 D 11DO _ _ 0.390 ne 10.92 10.34 - 20 20 223 211 0 0 0 . 0 - 13A-4ocs 0.143 se 4.00 2.19 348 318 1272 695 113 98 392 214 11 1A-r1om 1.270 se 35.56 34.90 30 30 1067 1047 15 7 533 523 13A-4ocs 0.143 sw 4.00 2.19 _ M1 _ _ 415 _ 1661 908 132 _ _ 117 467 255 1A-rlom 1.270 sw 35.56 34.90 45 45 1600 1570 15 7 533 523 1A-rlomd 1.270 sw 35.56 37.11 41 30 1451 1514 0 0 0 0 IA-r-lomd 1.270 sw 35.56 _ - 26.39 . - 41 82 1451 _ - _1077 . _ . 0- 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 344 314 1257 687 0 0 0 0 IA-rlom 1.270 nw 35.56. _ 43.03 30 _ _,0 - _ 1067 1291 _ _ - 0 0 - 0 0 C 16X19-0md. OA08 1.59 . 1.37 1007 - - -1067 1697 1378 - .168 168 266 - 230 C 17B-6al 0.105 2.94 4.30 787 787 2313 3386 0 0 0 0 F-- 22A-tpl 0.989 . - 27.69 0.00 1544 161 4458. - 0 - .168 26 720 _ 0 61 c) AED excursion 1 18801 1 1 1 30 Envelope loss/gain 1 215241 175031 1 1 29121 1775 12 a) Infiltration 3108 876 492 139 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Applianceslother 1000 0 Subtotal (lines 6 to 13) 24632 19609 3404 1914 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 9 8 14 Subtotal 24632 19609 3413 1922 15 Duct loads 10% 9% 2467 1672 10% 9% 342 164 I oad 278 21800I 3111 2088I Av retal qroom ui e (cfm) I I I 0 I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wp�igFtfi�pt �•�•� RightSuite®Universal 2021 21.0.08 RSU08101 2021-Oct-07 07:45.44Page 1 ..\Documents\Wdghtsoft HVAC\Linden Residence.rup Calc = MJ8 Front Door faces: NE - wrightsoft, Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 Room name Bath 2 Bedroom 3 2 Exposed wall 6.0 ft 25.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 5 Room dimensions Room area 10.0 x 6.0 ft 60.0 ft' 1.0 x 142.0 ft 142.0 ft' Ty Construction U-value Or HTM Area (ftz) Load I Area (ft2) I Load number (Btuh/Ft2.° (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) I (Btuh) Heat Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.19 0 6 6 6 113 98 392 214 1A-rlom 1.270 ne 35.56 43.03 0 0 0 0 15 0 533 645 D 11DO- 0.390 ne - 10.92 10,34 _ 0 0 0 0 0 0 0 0 w r---G 11 '13A-flocs 1A-rlom. 0.143 _ - . 1.270 se se 4.00 35.56 2.19 34.90 56 _ 0 56 0_ 226 0 123 0 122 15 107 7 426 533 235 523 _ 13-r1orn sw 4.56 4.19 . - 0 _- 0 _ _ 0 0 _ 0 _ _ 0 0 0 1A-rlom 1.270 1.270 sw 3@.56 34.90 0 0 0 0 0 0 0 0 IA-rlomd 1.270 sw 35.56 37.11 0 0 0 0 0 0 0 0 1A-rlomd 1.270 _sw. 35.56 26.39 0 .. .0 0 0 _ 0 0 0 0 w 13A4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 - _ 0 0 0 JA-r1om _-. - _ _ .- _ . 1.270 0w- _ 35.66 - 43.03.._ _ _ _ 0 0-- _ .. -0 ---0 _ _ _0 - 0 0- 0 �--G C 16X19-Omd 0.408 ._. -. 1.59 1.37 _. 60 60 95 _ 82 _ 142 ._ _ . 142 _ 225. 194 C 17B-6al_ 0.105 - 2.94 , 4.30 _ 0 0 _ 0 0 0 0 0 0 F 22A-tpl . 0.989 - 27.69. - 0.00 _ 60 6 _ _ - . _ 166 _ _ . , _ .. 0 _ 142 _ .. 25 692 . 0 61 c) AED excursion 1 1-51 1 139 Envelope loss/gain 1 487 201 1 1 2805 1773 12 a) Infiltration 114 32 473 133 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 601 233 3278 1906 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 19 619 0 16 248 0 18 3296 0 15 1921 15 Duct loads 10% 9% 62 21 10% 9% 330 164 Air al room loadrequired (cim) I I I 620I 210I I I 31007I 2088I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Q ?9hft vft" � � ^a-°�•�- PoghtSuite®Universal 202121.0.08RSU2021-Oct-07 07:45:4408101 Paget ...\Documents\Wdghtsoft HVAC1LInden Residence.rup Calc = MJ8 Front Door faces: NE - Job: wrightsoft, Right-J® Worksheet Entire House Date: Quick Calcs, Inc. ay° 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 Room name Bedroom 2 Hall 2 Exposed wall 27.0 ft 0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heaUcool 4 Room dimensions 1.0 x 166.0 ft 1.0 x 48.0 ft 5 Room area 166.0 ft' 48.0 fF Ty Construction U-value Or HTM Area (ft') Load I Area OF) I Load I number (Btuh/ft'= (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S I Heat I Cool j Gross I N/P/S Heat Cool 6 13A-4ocs - 1600 1400 3170 00 0 - 0 0 1A-rlom 1.270 1.270 no 35.56 35.56 43.03 43.03 15 0 6333 533 645 0 0 0 0 11DO ne _ _ 0 0 0 W �-G 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 11 1.270 se 35.56 34.90 0 0 0 0 0 0 0 _1A-rlom sw 4.O0 2.90 0 _0 0 0 0 0 _ _ _ _ 0 0 0 IA-rlom 1.270 1.270 sw 35.56 34.9D 0 0 0 0 0 0 0 0 TE�IA-rlocs IA-rlomd 1.270 sw 35.56 37.11 0 0 0 0 0 0 0 0 to-rlomd .. 1.270 .sw 35.56 _ 26.39 _ 0 0 3 _ _ 0 0 _ 0 0 0 V" 13A-4ocs 0.143 nw 4.00 2.19 94 94 376 206 0 0 0 0 1A-r1om 1.270 nw -- . 35.56 43.03 _ .._ . 0 -0 0 _ _ - - _ 0 - 0 - _ . _0 _ .. 0 0 C 16X19-0md - 0.408 - 1.59 .1.37 166, . _ 166 263 _ 227 48 48 _ 76 66 C 174-6al 0.105 - 2.94 4.30 0 0 0 0 0 0 0 F 22A-tp1 0.989 - 27.69 _ 0.00 _ _ _ 166 _ . _ 27 ___0 - 748 . _ _ 0 48 _ _ 0 0 0 61 c) AED excursion 1 -31 -1 Envelope loss/gain 25001 13641 1 1 761 64 12 a) Infiltration 511 144 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3012 1508 76 64 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 14 12 -76 -64 14 Subtotal 3025 1520 0 0 15 Duct loads 10% 9% 303 130 10% 9% 0 0 load Air 33981 18601 required (cfm) I Iom I I I O I A Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -P}+ wrigr.tsoft° 2021-Oct-0707:45-.44 ° RightSuiteO Universal 2021 21.0.08 RSLI08101 Page 3 ...%Documents%Wrightsoft HVAC1Linden Residence.rup Calc = MJ8 Front Door faces: NE '�" wright~soit° Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 Room name Great Room Dining 2 Exposed wall 15.0 ft 12.0 ft 3 Room height 11.7 ft heat/cool 11.6 it heaHcool 4 5 Room dimensions Room area 15.0 x 19.0 ft 285.0 ft' 12.0 x 8.0 ft 96.0 ft= Ty Construction U-value Or HTM I Area (ft2) Load Area (ft') Load number (Btuh/fV-* (Btuh/ftz) or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0.143 ne 4.00 2.16 6 6 0 0 6 6 0 0 1A-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 D 11D0. 0.390 ne _ 10.92 10.34 0 0 0 0 0 0 0 0 W �-c 13A4ocs 0.143 se 4.00 2.19 0 0 0 _ - 0 - _ 0 0 0 _ 0 11 IA-rlom _ 1.270 se 35.56 0_ 0 0- 0 0 0 0 0 13A4ocs 0.143 sw 4.00 _34.90 2.19 _ 141 111 444 _ 243 _ 113 72 288 158 lA-rlom 1.270 sw 35.66 34.90 30 15 1067 1047 0 0 0 0 1A-rlomd 1.270 sw 35.66 37.11 0 0 0 0 0 0 0 0 1A-rlomd _ 1.270 sw. 35.56 _ 26.39 _0 0 -- 0 _ -0- . 41 41. 1451 1077 V41 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 IA-rlom 1.270 _ nw 35.56 _ 43.03 _ 0 0 0 0 0 0 0 - - C 16X19-Omd 0.408 1.59 _ 1.37 _0 0 0 _ _0 0_- . _ 0 _ 0 0 0 C 17B-6al 0.105 - 2.94 4.30 381 381 1121 1642 171 171 503 737 F _ 22A-tpl . 0.989 ,- _27.69 0.00 • .. 285 15 . ___ _ 415, _ 0 _ 96 _ . .12 332 _ . 0 61 c) AED excursion 1 3821 1 1721 Envelope loss/gain 1 3048 3313 1 1 2575 2692 12 a) Infiltration 284 80 227 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3332 3394 2802 2756 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 16 3348 14 3407 0 2802 0 2756 15 Duct loads 10% 9% 335 291 10% 9% 281 235 Total room load 3684 31198 3082 991 2991 Air required (cfm) 109 139 91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -ij'f' 2021-Oct-07 07:45:44 • -� - RightSuite®Universal 202121.0.08RSU08101 Page ...\DocumentslWrightsoft HVAC1Linden Residence.rup Cale = MJ8 Front Door faces: NE - - wrightsoft• Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcaics@aol.com 1 Room name Kitchen Master Bedroom 2 Exposed wall 4.0 ft 30.0 ft 3 Room height 11.6 ft heat1cool 10.4 ft heat/cool 4 5 Room dimensions Room area 12.0 x 13.0 ft 156.0 ft' 15.0 x 15.0 ft 225.0 ft' Ty Construction U-value Or HTM Area (ft2) I Load I Area (ft') I Load I number (Btuh/ft2- (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 13A4ocs 0.143 ne 4.00 2.19 38 17 69 38 0 0 0 0 1A-rlom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 D 11DO 0.390 ne _ 10.92 10.34 20 20 223 0 0 0 0 '13A-flocs 0.143 se 4.00 2.19 0 0 _ 0 _211 0 0 0 0 0 11 1A-r1om 1.270 se 35.56 34.90 0 0 0 0 0_ 0 0 0 13A4ocs 0.143 sw 4.0-0 2.19 _ 0 0 0 0 156 115 461 252 -G 1A-r1om 1.270 sw 35.56 34.90 0 0 0 0 0 0 0 0 IA-rlomd 1.270 sw 35.56 37.11 0 0 0 0 41 15 1451 1614 1A-r1omd 1.270 sw 35.56 26.39 .0 _0 -. - 0 0 . .0 . 0 0 0 tVy 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 156 126 505 276 1A-r1om - 1.270 nw 35.56 43.03 0 0 0 0 30 0 1067 1291 -G C. 16X19-Omd 0.408 1.59 1.37 0 0 0 _ _ 0 225 . 225 - 357 308 C 17B-6al 0.105 2.94 4.30 _ _ 234 2.34 688 10.07 0 0 0 0 F 22A4pl 0.989 27.69 0.00 156 4 111 - 0 225 30 831 0 61 c) AED excursion -501 1 1 888 Envelope loss/gain 1090 1206 1 1 4671 4528 12 a) Infiltration 76 21 628 177 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 1166 2457 5299 4705 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1166 2457 5299 4705 15 Duct loads 10% 9% 117 209 10% 9% 631 401 taroom loadI 1238I 210000I 5172I 5106 Air rel quired (cfm) I I I I 192I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4 +wraisr, c.fe RightSuite®2021-Oct-0707:45,44Unlversa12021 21.0.08RSU08101 Pages ... \Documents\Wdghtsoft HVAC\Linden Residence.rup Calc = MJ8 Front Door faces: NE wrightsoit- Right-J® Worksheet Job: Entire House Date: Quick Caics, Inc. ay. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcaics@aol.com 1 Room name Master Bath M WIC 1 2 Exposed wall 5.0 ft 0 ft 3 Room height 9.4 ft heat/cool 9A ft heat(cool 4 5 Room dimensions Room area 1.0 x 100.0 ft 100.0 fP 5.0 x 5.0 ft 25.0 ft' Ty Construction U-value Or HTM Area (ftz) Load I Area OF) I Load I number (Btuh/ft2. (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1 MA -flocs 0.143 no 4.00 2.19 0 0 0 0 0 0 0 0 IA-rtom 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 D 11D0 - 0.390 -ne 10.92 10.34 _ 0 0 0 _ 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 _ _ 0 0 0 0 0 11 to -glom _ 1,270 se 35.56 0_ 0 0 0 0 0 0_ 0 -- 13A-flocs 0.143 - sw 4.00 -34.90 2.19 0 0 0 0 0 0 0 0 ,A-rlom 1.270 sw 35.56 34.90 0 0 0 0 0 0 0 0 T-G 1A-r1omd 1.270 sw 35.56 37.11 0 0 0 0 0 0 0 0 1A-rlomd - 1.270 sw 35.56 - 26.39 0 0 -. 0- - _ 0 0 0 0 0 VII 13A-4ocs 0.143 nw 4.00 2.19 47 47 188 103 0 0 0 0 1 A-rl om _ --. . 1.270 nw -- - 35.56 - 43.03 . -__- - __ 0 0-0 00 0 0 - G C 16X19-0md- 0.408 1.59 1.37 - _- 100 100 - - - -.159 137 - 25 - 25 -0 40 34 C 17B-6al 0.105 2.94 4.30 0 0 0 0 0 0 0 0 F 22A4pl .0.989 _ 27.69 0.00 . ._ .100. 5 138 -.- -0 _- . .-25 -0 _ -. 0 -0 61 c) AED excursion 1 1-5 -1 Envelope loss/gain 1 485 234 1 1 40 34 12 a) Infiltration 95 27 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 580 261 40 34 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 0 580 0 261 0 40 0 34 15 Duct loads 10% 9% 58 22 10% 9% 4 3 LI Totl room load638 I 283 31 Airrequi d (c m) I I 19I 11I I I 1 I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �°}�' wr•�gl�l�ofC 2021-Oct-07 07:45:44 Pight-Buite®Universal 2021 21.0.08RSU08101 Page ...\Documents\Wrightsoft HVAC\Linden Residence.rup Cale = MJ8 Front Door faces: NE wrightsoft Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcaics@aol.com 1 Room name M WIC 2 Laundry 2 Exposed wall 5.0 ft 6.0 ft 3 Room height 9.4 ft heatt000l 9.4 ft heat/cool 4 Room dimensions 5.0 x 5.0 ft 8.0 x 6.0 ft 5 Room area 25.0 ff 48.0 ft' T y Construction U-value Or HTM I Area ft' I Load I Area ft' I Load I number (Btuh/ft" (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 moo--cs 0.14-3 ne 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 1�G D 11DO 0.390 , ne 10.92 . 10.34 - 0 0 . 0 _ 0 - 0 _ 0 0 _ _ 0 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 56 56 226 123 11 1A-rlom 1.270 se 35.58 _ 34.90 _ _ 0 0 0 0 _ _ _ 0 0 0 0 1A-r1 ocs _ sw 4.56 _ _ 0 0 0 0 _ 0 0 0 0 1A-r1om 1.270 1.270 sw 35.56 4.90 34.90 0 0 0 0 0 0 0 0 IA-rlomd 1.270 sw 35.56 37.11 0 0 0 0 0 0 0 0 1A-rlomd. 1.270 sw _- _ 35.56 - 26.39 0 0 0 - -0 0 . _ _ 0. 0 0 1y 13A-4ocs 0.143 nw 4.00 2.19 47 47 188 103 0 0 0 0 1A-rlom. 1.270 nw.. __35.56 43.03 - _ 0 0 --_ - . _ 0 - .. _ __0 __ 0 0 0 0 -G C 16X19-0md 0.408 r 1.59 . 1.37 - 25 25 40. 34 .. 48 48 76 66 C 176-0al 0.105 2.94 4.30 0 0 0 0 0 0 0 0 F.22A-tpl 0.989 _ .27.69 0.00 25 _5 _ 138 0 _ .. 48 . - . _ _ 6 166 . 0 61 c) AED excursion 1 -3 -4 Envelope loss/gain 366 134 1 1 468 185 12 a) Infiitration 95 27 1 114 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 461 160 582 217 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 461 160 582 217 15 Duct loads 10% 9% 46 14 10% 9% 58 18 Aoreqroom load 505I 177I 649I 239I ui d (cfm) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -� -R& 2021-Oct-07 07:45.44 RlghtSuite®Unierl 2021 21.0.08RSU08101 APage 7 ...1DocumentslWrightsoft HVAC\Linden Residence.rup Calc = MJ8 Front Door faces: NE - �wrightsoft° Duct System Summary oat Entire House By: Quick Calm, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcaics@aol.com Project Information For: Linden Residence 2411 Atlantic Beach Boulevard, Fort Pierce, FL 34949 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.315 in/100ft 800 cfm 159 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.315 in/100ft 800 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 2 h 681 20 10 0.324 4.0 Ox 0 VIFx 39.3 115.0 st3 Bedroom 2 h 3328 98 62 0.346 7.0 Ox 0 VIFx 29.6 115.0 st4 Bedroom 3 h 3627 107 78 0.315 7.0 Ox 0 VIFx 43.8 115.0 st3 Bedroom 4 h 3755 111 78 0.328 7.0 Ox 0 VIFx 37.7 115.0 st3 Dining C 2991 91 112 0.368 7.0 Ox 0 VIFx 21.0 115.0 st1 Great Room C 3698 109 139 0.353 7.0 Ox 0 VIFx 26.8 115.0 st4 Kitchen C 2666 38 100 0.384 7.0 Ox0 VIFx 15.3 115.0 SO Laundry h 640 19 9 0.377 4.0 Ox 0 VIFx 17.5 115.0 st1 M wic 1 c 36 1 1 0.385 4.0 Ox 0 VI Fx 14.9 115.0 st2 M WIC 2 h 507 15 7 0.393 4.0 Ox 0 VIFx 12.2 115.0 st2 Master Bath h 638 19 11 0.390 4.0 Ox 0 VIFx 13.1 115.0 st2 Master Bedroom C 5106 172 192 0.385 8.0 Ox 0 VIFx 1 14.9 115.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 238 167 0.315 436 10.0 0 x 0 VinlFlx st4 Peak AVF 207 201 0.346 469 9.0 0 x 0 VinlFlx st1 Peak AVF 148 222 0.368 501 9.0 0 x 0 VinlFlx st2 Peak AVF 207 211 0.385 477 9.0 0 x 0 VinlFlx -�- wrightsOft- 2021-Oct-0707:45:44 � ..�d.kw...d , RghtSulteOUniversal2021 21.0.08 RSU08101 Page 1 RUA ...\Documents\Wdghtsoft HVAC\Linden Residence.rup Calc = MJ8 Front Door faces: NE Name Grille Size (in) Htg (cfm) Clg (cfm) TEL M Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 800 800 0 0 0 0 Ox 0 VIFx wrightsaf - RghtSuiteOUniversal2021 21.0.08 RSU08101 ...1DocumentslWrightsoft HVAC\Linden Residence.rup Calc = MJ8 Front Door faces: NE 2021-Oct-07 07:45:44 Page 2