HomeMy WebLinkAboutTruss DrawingOF, .. 78, D" ,. 21'-B" ,. Products PIotID Net Qty Product Length Plies J1 9 16' BCI@ 4500s-1.8 18' 0" 1 J2 3 16" BCI@ 4500s-1.8 16' 0" 1 J3 10 16" BCI® 450os-1.8 1610 1 J4 1 16" BCI@ 4500s-1.8 16' 0" 1 J5 1 16" BCI04500s-1.8 16' 0" 1 J6 3 16" BCI® 450OS-1.8 4' 0" 1 J7 10 16" BCI@ 6000S-1.8 21' 0" 1 J8 1 16" BCI@ 6000s-1.8 20' 0" 1 J9 4 16" BCI@ 6000s-1.8 20' 0" 1 BM1 2 1-3/4" x 16" VERSA -LAM@ 2.0 3100 SP 20' 1 1/8" 2 Bk1 18 16" BCI@ 4500s-1.8 2' 0" 1 Bk2 4 16" BCI@ 45OOs-1.8 1.0. 1 Connector Summary PlotID Qty Manuf Product Skew Slope Hut 24 Simpson ITS1.81/16 - - Hu2 15 Simpson ITS2.37/16 - - Hu3 16 Simpson IUS1.81/16 - - STRONGBACKS REQUIRED DUE TO DEFLECTION DIFFERENTIAL (SEE STRONGBACK LETTER IN ENG. PACK) 10R WArrmuu o'ECDVENESS INSTALL STRMCEACAS BEFORE SM(ETING IS APPLIED m TRUSSES. Mimi 01MIMIMIMMIMINIENNEIMINI �It•1�1=1=1�I�I�I�Ir�l�l�l�l�l�l�l� ICI I�It_It•I���i�l�l�l�l�lt_ 1 I�I�I�I�I�I�I�I�I�I�I�It•It•I�1�1�1�1�1 �I�It•I�I�I�I�I�I�I�I�1�1�1�1�1�1�1�{ 1 Will 1-11 III II I 11'_I'_1_I'_I'_1_1_I1_1_I 1 ;unit - �II `I -II -II_J I®IIMMIIMJ hI■I�I�I�I■I�I�I�I 1 I I I I 1 I I 1 1I-II -II— I I ���������������■���� 1 I�1�1�11�1�1�1�1�1 ;M11MI�II • I�I�II�It�l�l�l�l�l�l .27 r FILE pY REVIEWED 7:::I- LI (- 4-L-ae 1-7 3 a Totat Truss Quantity = 1D7. THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT. Iz 5 � Zy,4 HEEL6-3/1 _ _ '- 1J0 PLUMB CU Rune Compliance Universal Engineer ng Sciences LEDGER BY OTHERS L1/2" GAP TYPICAL REFER TO PACK FOR CONNECTION. CJ5 1 0I CJ3 Z� Bl m U CJ U U 1�-016�� U TYPICAL 7' SETBACK CORNERSET LABELING AND SPACING LOAD# DESCRIPTION INIT. DATE Boa 1DA➢ MINT z2ene RB. vt DI, lu a W.ve Loma RIs RE01 BASE LOAD Be0 VIVID RF01 BASE LOAD a/BO/I6 Bro1 BASE LEAD "amelus RG01 BASE LEAD LDB 1H/33/39 In BASE LOAD LDB 9N719 R101 BASE LOAD FLAR BA E LEAD LOAD# DESCRIPTION INIT. DATE COPY TBU RAN !We MIT 28/IB CRa W➢CRS BUD B/16/1B BIB REV. REs J N e/3o/18 BIBREVVB EQUSCTna INrtE Le. 12/1e 10/13/19 Inc DESIGNED rLR --U05' LOB 01➢ RE S'D 1ACE AC NT CANEIR$ 9/11/11 BIE _.a HAILERS EDW al/23/zo In" Cn/8223867 L➢H U17/2a HANGER CHART At— HUS 26 (SIMPSON) III— HUS26-2 (SIMPSON) Labeled End Mark NETS. DO NOT CUT M ALTER TRUSSES WIT- T C@1SENT GF THIS MFICE. BACK CHARGES WILL NGT BE ACCEPTED WITNDUT PRIM WRITTEN APPROVAL BY CUR SERVICE DEPARTMENT AT CARPENTER CGNTRACTMS GF ANERICA, NC 877-293-9487 NGTE: ALL BEARING WALLS NEED IIIBE INSTALLED PRIM TG SETTING TRUSSES. General Notes 1) All parallel chord trusses, flat trusses and flat girders have the top chard padially painted green to be installed green side up. AD hangers to be Simpson HUS26 unless otherwise 2) noted. AD truss spacing is 24" O.C. unless otherwise 3) noted. Per Truss Plate Institute SCSI-BI recommendation 4) permanent X-bracing should be placed at a mcAinum spacing 15' O.C. across the span, to be repealed at a morimum of 20' between each X-brace throughout thestructure. Please refer to BCSI-BI for any additional bracing details. ROOF LOADING SCHEDULE TCLL = 20 PSF BCLL = * PSF BCDL = 10 PSF TOTAL = 9.2 PSF DURATION = 1.25 % WIND SPD/TYPE= 160 ENCLOSED BLDG EXPOSURE = C USAGE =RESIDENTIAL CAT II WIND IMPORTANCE FACTOR= 1 UPLIFTS BASED ON= 9.2 PSF DESIGN CRITERIA FBC 2020 TPI 2014 Tr„4" member design & co _ plates ae designed for ASCE7-IB andmaximlm forces Gam both ComDCGentR.and claddings and main wind force resisting systems. • These trusses have been reviewed to cazry ao Carnal I ON psf aon-concmrmt bottom chord live load. FLOOR LOADING SCHEDUL TCLL = 40 PSF TCDL = 10 PSF BCDL = 5 PSF TOTAL = 55 PSF ROOF DESIGNED FOR SHINGLE ALL REACTIONS OVER 1111, AND UPLIFTS OVER 10D0# ARE SHOWN ON ENGINEERING. WALL KEY 8'-81, ®18'-1"14 ILIAD# DESCRIPTION INIT. DATE RJ% S1ff WAB Los 740/20 Ot BAa t➢AB ➢e IV20/20 RL01 BASE LanD L. le/112o LOAD# DESCRIPTION INIT. GATE RELABELED LD3 1/10/20 LEA Le.V2020 ON REVS'D RE'S Lae 1I— REv TJt LABELS a 2 U'.21 InH RELABLE —1 P1.031B.2o21 CARPENTER CONTRACTORS OF AMERICA 3900 AVENUE G. N.W. WINTER HAVEN FLDR I➢A 33880 PHONE (800) 959-6806 FAX- (863) 294-2488 BUILDER DR HORTON-BREVARD PROJECT CREEKSIDE MODEL 4EHB/ HAYDEN/ H CCA PROJ/MODEL/ALT 7A5/320/4EHJH/01 (I -JOIST FIR SYSTEM) ALT DESC 10' X 8' COV. LAN. OTC LOT 60 BLOCK DESIGNER PAGE RAA i 1 DATE 10 24 17 LAN## N362326R SCALE 3 16 "=1'