HomeMy WebLinkAboutProduct Review AffidavitQ /7^ Product Review Affidavit (White or Bronze aluminum) I Q 2
Address: // r u / C��l�4C _ LOT #
Product Approval
Product
Opening Design
Product Rated
Manufacturer
Model #
Glass Type
Method of Attachment
Number
Pressure
Design Pressure
1/4" concrete screw 6" edge distance @ head, 4" edge distance @ jamb, 4" each side of transom centerline to
FL20461.17-R5
Opaque single door
(+36) / (-47)
(+47) / (-47)
Therma-Tru
Smooth Star
N/A
bucking. Tapcon spacing @ 15" o/c max. @ head and jamb. Min. embedment of all anchors to be 11/4"
with transom
For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to
achive a 11/4" minimum embed. Into substrate. Locate anchors as shown in elevations and installation
FL17499.2-R8
SH Window
(+38 / (-48)
(+60 ) / (-60)
MI Window and
185 SH
Non Impact
details.For anchoring through frame into masonry/ concrete use 3/16" tapcons with sufficient length to achive
Doors
a 11/4" minimum embed. Into substrate. Locate anchors as shown in elevations and installation details.
For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to
SH Window (Integral
MI Window and
achive a 13/8" minimum embed. Locate anchors as shown in installation details.For anchoring through frame
FL15353.2-R5
Mulled)
(+38) (-48)
/
(+48.1 / (-48.1)
Doors
5764
Non Impact
into masonry /concrete use 1/4" ELCO ultracon tapcons with sufficient length to achive a 11/4" minimum
embed. w/ 1" min. edge distance. Locate anchors as shown in installation details.
For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to
achive a 11/4" minimum embed. Into substrate. Locate anchors as shown in elevations and installation
FL15349.1-R14
Fixed Window
(+38) / (-48)
(+60) / (-60)
MI Window and
185 PW
Non Impact
details.For anchoring through frame into masonry / concrete use 3/16" tapcons with sufficient length to achive
Doors
a 11/4" minimum embed. Into substrate w/ min 21/2" edge distance. Locate anchors as shown in installation
details.
For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to
achive a 13/8" minimum embed. Into substrate. Locate anchors as shown in elevations and installation
FL15332.2-R6
Sliding Glass Door
(+33) / (-41)
(+48.2) / (-48.2)
MI Window and
Series 420
Non Impact
details.For anchoring through frame into masonry /concrete use 3/16" tapcons with sufficient length to achive
Doors
Aluminum SGD
a 11/4" minimum embed. Into substrate w/ min 2 1/2" edge distance. Locate anchors as shown in installation
details.
FL16107.3-R13
Double Garage Door
(+29) / (-35)
(+36) / (-42)
Clopay
16.2x7 73 W6
N/A
3/8" x 2-3/4" Hilti sleeve anchors 6" from ends 22" O/C
3/8" Simpson Titen heavy duty screw anchor with 1 1/8" OD washer into grout filled CMU with min. emben of
FL8248.11-R20
Double Garage Door
(+29) / (-35)
(+34.4) / (-38.3)
Wayne Dalton
8024
2 3/4", min. edge distance of 4" and min. end distance of 4". Max fastener spacing of 20". 3/8" dia. X 3" long
(Alt)
lag screws with 1" OD washers with a 19/32" thread penetration into seasoned dry wood supporting
structure.
Double Garage Door
3/8" Simpson Titen heavy duty screw anchor with 2 3/4" embed min 6" between jamb and bracket location. 2
FL14170.7-R14
(Alt)
(+29)/(-35)
(+34.4)/(-38.3)
Overhead
77,Ser18
177, 180-185, 187
8
3/4" min edge distance.
-185,
Use galvanized (zinc coated) roofing nails,11 or 12 gauge, with at least 3/8" dia. heads, long enough to
penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge,
FL30310.1-R1
Roof
IKO Cambridge
N/A
approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush
with, but not cutting into shingle surface.
FL15216.1-R8
Underlayment
Intenvrap
RhinoRoof U20
N/A
Miami -Dade approved corrosion resistant tin -caps and 12 gauge 1 %" annular ring -shank nails,
spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll
FL5259.1-R31
Underlayment (alt)
Polyglass USA
Polystick IRXE
N/A
Self adhesive
FL17322.1-R7
Underlayment (alt)
Atlas Roofing
WeatherMaster
N/A
Self adhesive
Corp
100
FL34546.1
Underlayment (alt)
-
-
Owens Corning
Shield Granulated
N/A
Self adhesive
FL27076.16-R1
Underlayment (alt)
APOC
Weather Armor
N/A
Self adhesive
SB-1
FL15272.1-R3
Soffit
+31.6, -38.8
(+157) / (-46.1)
PlyGem
Veriform
Install per manufacturers recommended requirements.
FL15272.1-R3
Soffit (a It)
+31.6, -38.8
(+75) / (-75)
Alside
T2
Install per manufacturers recommended requirements.
FL3792.5-R14
Off Ridge Vent
Lomanco
770D
N/A
Install per manufacturers recommended requirements.
FL19567.2-R2
Off Ridge Vent (alt)
Millinium Metals
MMI
N/A
Install per manufacturers recommended requirements.
1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 13/4" in concrete / masonry, 2 1/2"
FL16293-133
Hurricane Panels Less
(+47) / (-53)
Hurricane Storm
24 GAGE
N/A
min. edge distance, 12" o/c max. spacing. Can be headed screw or all thread but with wing nuts.
than 6' span
panel MFG.
1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 13/4" in concrete / masonry, 2 1/2"
FL16293-R3
Hurricane Panels 6'
(+45) / (-50)
Hurricane Storm
24 GAGE
N/A
min. edge distance, 12" o/c max. spacing. Can be headed screw or all thread but with wing nuts.
span or more
panel MFG.
FL17147.2-RS
Zip System Sheathing
Huber
Wall Sheathing
N/A
Install per manufacturers recommended requirements.
FL13192.1-R6
Lap siding
James Hardie
Cemplank
N/A
Install per manufacturers recommended requirements.
FL1392.1-R7
I Joists (2 story only)
Boise Cascade
BCI
N/A
Install per manufacturers recommended requirements.