Loading...
HomeMy WebLinkAboutProduct Approval Roofing Underlayments311SOC121 Florida Building Code Online ........... . i.. .. . . . . . . . . . . . . . ........ ........ .s 13CI_c Ymne Log In U ser �� i;fscrz o - i-.oI Topics ', Submit Surcharge I Stats & Facts � Publications ' Contact ifs BCCS Site Map Search db"'r 4`0' Product Approval a USER: Public User *�'' Product Approva[ Menu > Product or Application Search > Application LiSt > Application Detail FL # FL14317-R11 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Boral Roofing Address/Phone/Email 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (801) 380-6091 RobmAndersong borai.com Authorized Signature Anderson Robin RobinAnderson@borai.com Technical Representative Adrian Cooper Address/Phone/Email 135 NW 20th Street Boca Raton, FL 33431 (954)S20-S461 acoopeer@minierlifetile.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Fiorida License PE-59166 Quaiity Assurance Entity UL LLC Quality Assurance Contract Expiration Date 04/30/2023 validated By John W. Knezevich, PE Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Validation Checklist - Hardcopy Received FL14317 R11 COI 2020 01 COI NIEMINEN.pdf Standard ASTM D1970 FRSA/TRI 6th Edition TA5 103 UL 1897 Year 2015 2018 Zozo 2015 Sections from the Code https:dflc)ridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgsbCU ITKe#2OBoXpSjktfpju5SjCf9N BzeRczhREBCXVW%3d%3d 1/2 3/16/2021 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products Method 1 Option D 11/25/2020 12/05/2020 12/12/2020 02/09/2021 02/15/2021 FL # Model, Number or Name Description 14317.1 Boral Roof Underlayments Roof underlayments for use in prepared roof assemblies Limits of Use Installation Instructions Approved for use in HVHZ: No FL14317 R11 11 2020 11 25 FINAL ER BORAL Underlayments FL14317- R11.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert 1. M. Nieminen PE - 59166 Design Pressure: +N/A/-210 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application pertains to a particular underiayment FL14317 R11 AE 2020 11 25 FINAL ER BORAL Underlayments FL14317- R11 pi f system for use in Ule roof systems. Refer to ER Section 5.8.2. 2.) Refer to EA Section 5 for Limits Created by Independent Third Party: Yes of Use. Contact Us :: 2601 Blair Store Road, Tallahassee FL 32399 Phone: 950-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Fniva y Statement :: Accessibility Statement :- Refund Statement Under Florida law, email addresses are pubilc records. If you do not wart your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(S), Florida Statutes, effective Cctober 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: Credit Card Safe https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsbCUITKel20BaXp5jktfpju5SjCf9NBzeRczhREBCXVW%3d%3d 2/2 23 NEW I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION . . Boral Roofing Evaluation Report M35710.12.10-R12 7575 Irvine Center Drive, Suite 100 FL14317-R11 Irvine, CA. 92618 (602) 269-2288 Date of Issuance: 12/21/2010 Revision 12: 11/25/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. AovERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc, Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robertl.M. Nieminen, P.E. OF 3-•C��7•S .s.�.: �;•``F „ The facsimile seal appearing was authorized by Robert Florida Registration No, 59166, Florida DCA ANE1983 _'�� ;;;�,,,T "5 Nieminen, P.E. on 11/25/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates, 2. NEIVO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LTC NNEMO I etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category. Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections of the 7" Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind resistance UL 1897 2015 1507.1.1, 1507.2.4, 1507.2.9.2 / Material standard ASTM D1970 2015 R905.1.1, R905.2.8.2 15073.3 / R905.3,3 Material standard FRSA/TRI, Sixth Edition 2018 TAS 110 Material standard TAS 103 2020 3. REFERENCES. - Entity Examination Reference Date ERD (TST 6049) ASTM D1970 / D4798 M36790.07.11 09/30/2011 ERD (TST 6049) ASTM D226,D1970 B40380.08.12 08/28/2012 ERD (TST 6049) TAS 103-20 (tensile adhesion) C41420.09.12-2 09/11/2012 ERD (TST 6049) ASTM D1970 (adhesion) B41940.09.12 09/13/2012 ERD (TST 6049) TAS 103-20 (tensile adhesion) B47390.07.14-1 07/31/2014 ERD (TST 6049) TAS 103-20 (tensile adhesion) B47390.09.14 09/04/2014 OC (PDM1838) Physical Properties Equivalency statement 11/02/2017 PRI (TST 5878) ASTM D1970 NEI-031-0Z-02:REV 10/27/2010 PRI (TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI (TST 5878) TAS 103-20 (tensile adhesion) NEI-046-02-01REV 12/17/2010 PRI (TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 PRI (TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013 PRI (TST 5878) Wind Uplift BORR-001-02-01 03/17/Z015 PRI (TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 PRI (TST 5878) TAS 103-20 (tensile adhesion) DAPF-002-02-01 03/08/2018 PRI (TST 5878) ASTM D1970 (adhesion) OCF-443-02-01 10/11/2018 UL, LLC. (QUA 9625) Quality Assurance Service Confirmation 09/21/2017 UL, LLC. (QUA 9625) Quality Assurance Florida BCIS Current 4.1 4.2 4.3 4.4 4.5 ODs Product Material Standard Plant(s) Description Boralm TileSeal 50"T ASTM D1970 Brentwood, nominal 50-mil thick, polyester surfaced, self -adhering SBS NH modified bitumen roof underlayment Boras' TileSealHT ASTM D1970 and Brentwood, nominal 60-mil thick, polyester -surfaced, self -adhering SBS FRSA/TRI 09-18 NH modified bitumen roof underlayment Boral® MetalSeal"T ASTM D1970 and Brentwood, nominal 60-mil thick, polyester -surfaced, self -adhering SBS FRSA/TRI 09-18 NH modified bitumen roof underlayment GatorSeal® ASTM D1970 Brentwood, nominal 55-mii thick, granule -surfaced, fiberglass reinforced, NH self adhering SBS modified bitumen roof underlayment Citadel" Plus ASTM D1970 Brentwood, nominal 48-mi[ thick, fabric -surfaced, fiberglass reinforced, NH self -adhering SBS modified bitumen roofing underlayment for use as a base -layer in multi -ply underlayment systems NEMO ETC, LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization #32455 7TH EDITION (2020) F6C NON-HVHZ EVALUATION FL14317-R11 Elora Roof Underlayments; (602) 269-2288 Revision 12: 11/25/2020 Page Z of 6 NEMO I etc. 5LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties), 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof covers. Refer to the installation instructions for multi -ply underlayment options. TABLE 1: ROOF COVER OPTIONS FBC Section: 2507.2 1507.3 1507.4 & 1507.5 150T7 1507.8 & 1507.9 Clay and Concrete Tile Metal Slate or Wood Underlayment Asphalt Slate -Type Mechanical Adhesive- Shingles Attach Set Panels Shingles Shingles Shingles & Shakes Boral TileSeal 50NT Yes No No Yes Yes Yes Yes (jointstrips,1507.1.1.3 /8905.1.13J Boral TileSeal"T Yes Yes Yes Yes Yes Yes Yes (See 5.6.1) (lointstrips, 1507.1.13/R905.1.1.3J Boral MetalSeaiHT Yes Yes Yes Yes Yes Yes Yes (See 5.6.1) 6ointstr;ps, 1507.1.1.3/R905A.1.3J GatorSeal Yes No No No No Yes Yes (joint strips, 1507.1.1.3 / ld905.1.1.3) 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval Boral Tile5eal"T or Borai MetalSealHT DAP Foam "Touch `n Seal Storm Bond Roof Tile Adhesive" FL14506 Boral TileSeal"T or Bora! MetalSealHT DAP Foam "Touch 'n Seal Storm Bond 2 Two -Component Polyurethane Roof Tile Adhesive" FL21374 Boral TileSealHT or Boraf MetalSealHT Dupont "Tile Bond'" Roof Tile Adhesive" FL22525 Boral TileSeal"T or Boral MetalSealHT ICP Adhesives and Sealants "Polyset® AH-160" FL6332 Boral TileSeal"T or Boral MetalSealHT ICP Adhesives and Sealants "Polyset® RTA-1" FL6276 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product r'ipproval for Oyerturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report M35710.12.10-R12 Certificate ofAuthorization#32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL14317-R11 Boral Roof Underlayments; (602) 269-2288 Revision 12: 11/25/2020 Page 3 of 6 NNEMOletc. 5.7 Allowable Substrates: TABLE. 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates Citadel Plus, Boral TileSeal 50HT, Boral TileSeal"T, Boral MetalSeaIHT or GatorSeal self -adhering (Optional) ASTM D41 plywood none ASTM D226 Type II felt or Citadel Plus ASTM Q41 metal (flashing metal, valley metal, etc.) Boral TileSeal"T, Boral MetalSeaJIT self -adhering (Optional) ASTM D41 OSB Boral TileSeal"T self -adhering (Optional) ASTM D41 Huber "Zip Deck" None G-P Gypsum "DensDeck Prime" 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but --for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for UnderlaVment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 91 Maximum Design Pressure = -120.0 post: Deck: Min. IS/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 to the plywood deck Base Ply: Citadel Plus, self -adhered Cap Ply: Boral TileSeai"T or Boral MetalSeal"T, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c, #2 Maximum Design Pressure = -142.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Ply: Boral TileSeal"T or Boral Meta5eaIIT, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure = -202.5 Psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Ply: Boral T11e5eal"7 or Boral MetalSeal"T, self -adhered, and rack -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. NEMO ETC, LLC Evaluation Report M35710,12.10-R12 Certificate of Authorization #32455 7T" EDiTION (2020) FBC NON-HVHZ EVALUATION FL14317-R11 Boral Roof Underlayments; (602) 269-2288 Revision 12: 11/25/2020 Page 4 of 6 MEMO I etc. #4 Maximum Design Pressure = -210.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK #89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Ply: Boral TileSeal"r or Boral MetalSeal"r, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x IN" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure = -120.0 psf: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self -adhered Cap Ply: Boral TileSeal"r or Boral MetalSeal"T, self -adhered #6 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Maximum Underlayment Prepared Roof Cover Installation Type Exposure (days) GatorSeal Mechanically attached 30 Boral TileSeal 50"r Mechanically attached 190 Boral TileSeal"Tor Boral MetaiSeal"r Adhesive -set tile roof system 30 Mechanically attached 180 Citadel Plus (base ply in multi -ply underlayment systems only) NSA 180 (prior to placement of subsequent underlayment) 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment* Tile Profile Staging Method Maximum Slope Boral TileSeal"T or Boral MetalSeal"r Flat or Lugged Max. 10-tile stack 6:12 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 5.3 Boral TileSeal 50"1 or GatorSeal: . 6.3.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type 11 felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. NEMO ETC, LLC Evaluation Report M35710.12.10-R12 CertificatebfAuthorization #32455 77H EDITION (2020) FBC NON-HVHZ EVALUATION FL14317-R11 Boral Roof Underlayments; (607) 269.7788 Revision 12: 11/25/2020 Page 5 of 6 MEMO I etc, 6.3.2 Multi-P.ly Underla ment Systems* One or two plies of Citadel Plus followed by Boral TileSeal 50"T or GatorSeal is allowable for use under mechanically attached, non -tile prepared roof systems- Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired. 6.4 Boral TileSeal"T or Boral Metal5eal"T: 6.4.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507-1.1.3. or 1507.1.1.3 or FBC Residential R905.1.1.1 or 111905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type 11 felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.2 Tile Applications: Shall be installed in compliance with requirements for a Self -Adhered Membrane in the FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.2 for attachment limitations. Refer to Table 4 for tile staging limitations. 6.4.3 Multi -Ply UnderlaVment Systems: One or two plies of Citadel Plus followed by Boral TileSeal"T or Boral Metal5eal"T is allowable for use under mechanically attached, non -tile prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired. Refer to Section 5.8.2 for use of Citadel Plus as a base ply membrane in underlayment systems for use under tile - roof systems. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS' Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC--QUA9625; (414) 248-6409; Karen.buchmann@ul.com - END OF EVALUATION REPORT - MEMO ETC, LLC Evaluation Report M35710.12.10-R12 Certificate ofAuthoriration #32455 7W EDITION (2020) FBC NON-HVHZ EVALUATION FL14317-Rll Boral Roof Underlayments; (602) 269-2288 Revision 12; 11/25/2020 Page 6 of 6