Loading...
HomeMy WebLinkAboutProduct Approval Roof Tile Adhesivesh€oncla building Code Untme go € lit urn, I Submit surcharge Slats & Facts Publications contact Us Beis Site Map Links Search 4Product I`�i)I 1��3 Approval USER: Public user I . . P Pro UCt Approva_, I Menem > Product or Ap pli[ation Search > Application List > Application Detail FL It FL6332-R9 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer ICP Adhesives & Sealants, Inc. Address/Phone/Email 12505 NW 44th Street Coral Springs, FL 33065 (888) 774-1419 Ext 201 rylipelkonen@icpadhesives.com Authorized Signature Riku Ylipelkonen rylipelkonen@icpadhesives.com Technical Representative Address/Phone/Email Qua€ity Assurance Representative Address/Phone/Email Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/07/2021 Validated By Sohn W. Knezevich, PE Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Validation Checklist - Hardcopy Received FL6332 R9 COI 2020 01, CQi NIEMINEN.pdf Standard SSTD 11 Method 1 Option D Year 1997 https-fifioridabuilding.org/prtpr_app_dti.aspx?param=wGEVXQwtQquanClKft6f%2SM%2b3ax6XpXuonH4Z5Ett-Mrw%3d 112 111ZJZUcl Florida Building Code Online Date Submitted 09/79/2020 Date Validated 10/04/2020 Date Pending FBC Approval 10/11/2020 Date Approved 12/15/2020 Summary of Products FL # Model, Number or Name Description 6332.1 POLYSET AH-160 Dual component expanding polyurethane roof tile adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL6332 R9 11 2020 09 29 FINAL ER P LY ET Approved for use outside HVHZ: Yes AH160 FL6332-Rg. df Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +n/a/-178 Created by Independent Third Party: Yes Other: 1.) The design pressure limitation in this application Evaluation Reports refers to hip and ridge tiles in one configuration. Refer to Table FL6332 R9 AE 2020 09 29 FINAL ER P LY ET 2 of ER for all hip and ridge tile limitations. 2.) Field tiles are AH160 FL6332-R9.p&1f designed based on overturning moment resistance. Refer to 'fable Created by Independent Third Party: Yes 1 of ER for field tile limitations. 3.) Refer to ER Sections 5 for other Limitations of Use. ootact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO emplayer. Lapyri 2007-2013 Stake of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic Mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant to Section 455.275(1), Flonda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official cnmmunfcatlon with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click her Product Approval Accepts: � _ Credit Card Safe https:lifloridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquanCtktt ft6f%2fMa/`2b3ax6XpXuonHOZ5EfLMrw%3d 212 NEMO I etc. Certificute of Authorizotion #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT REPORT.EVALUATION ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-R9 12505 NW 441h Street FL6332-R9 Coral Springs, FL 33065 Date of Issuance: 08/08/2008 (889) 774-1419 Revision 9: 09/29/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: POLYSET® AH-160 LA13ELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility locations) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: , t„ r nrnn,n, ?,�Xa�34ti. Robert J.M. Nieminen, P.E. 'T The Facsimile seal appearing y ppea rin was authorized b Robert Florida Registration No. 59166, Florida DCA ANE1983 ? i;, ;',;`..'' Nieminen, P.E. on 09/29/2020. This does not serve as an electron ica Ry signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, RC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3, Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product, 5. This is a building code evaluation. Neither NFMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, Li_C ROOFING COMPONENT EVALUATION: NNEMOJetc. Product Category: hoofing Sub -Category: Roof Tile Adhesives Compliance Statement: POLYSET40 AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Cade through testing in accordance with the Standards set forth herein, Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDk Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES.* Entity Examination Reference Date ERD (TST 6D49) Static Uplift — SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) Static Uplift--SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES (EVL2396) 2012 IBC Compliance ESR-1709 12/01/2018 Miami -Dade (CER 1592) HVHZ compliance 17-0322.03 04/27/2017 NEMO (TST6049) Tensile Adhesion (ridge metal) 4i-ECM-20-SSCRT-01 09/29/2020 NEMO (TST6049) Tensile Adhesion 4p-ICP-20-55LAP-01 09/29/2020 PRI (TST 5878) Static Uplift — SSTD 11 ECM-001-02-01 09/21/2001 PRI (TST 5878) Static Uplift —SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift--SSTD 11 PFI-006-02-02 05/09/2005 PRI (TST 5878) Static Uplift — SSTD 11 PFI-007-02-01 10/11/20G5 PRI (TST 5878) Static Uplift—SSTD 11 PFI-009-02-04 02/21/2006 PRI (TST 5878) Static Uplift — 5STD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift — SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift — SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) Static Uplift --• SSTD 11 PFPI-011-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-012-02-01 12/07/7006 PRI (TST 5878) Static Uplift — SSTI) 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift -- SSTD 11 LCM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-004-02-01 06/13/2008 PRI {TST 5878) Static Uplift—SSTD 11 ECM-005-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-006-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-008-02-01 06/13/2008 UL LLC (QUA 9625) Quality Assurance Service Confirmation 02/07/2018 UL, LLC, (QUA 9625) Quality Assurance Florida BCIS Current PRODUCT ESCRIPTION POLYSET° AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders. NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Cer[fficoteofAurhorfzoiion032455 7"` EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSETe Ali-160 Revision 9: 09/29/2020 Page 2 of 10 NNEMOletc. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zane jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or R902 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. 5.6 POLYSETO AH-160 may be used with flat, low and high profile tiles having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.7 Field tiles, meeting the limitations of FBC 1609.5.3, using POLYSET® AH-160 are limited to projects having an Aerodynamic Uplift Moment (M,,), determined in accordance with Table 2HB, 2HC, 2HD, 2136, 2GC or 2GD of FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or FBC 1609.5.3, not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 1: FIELD TILES IN POLYSETO AH-160 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA (MARGINS OF SAFETY AREADYAPPLI ED) Tile (FBC 1609.5.3) Adhesive Paddy Placement (Section 10) Allowable Placement Overturning Type Profile Detail Paddy Details Moment (ft-lbf) #1 Independent; Single Paddy, Medium (2x7-inch, ^30 gram) 60 Clay or Flat /Low #2 Independent; Single Paddy, Large (2x10-inch, -45 gram) 112 Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at file Concrete 113 overlap) 54 41 Independent; Single Paddy, Medium 120-inch, ^30 gram) 39 Clay or Medium #2 Independent; Single Paddy, Large (2x10-inch, -54 gram♦ 67 #3 Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile Concrete overlap) 58 Clay High #3 Independent; Single Paddy, Large (2x10-inch, -45 gram) 134 41 Independent; Single Paddy, Medium (20-inch, "30 gram) 65 Clay or High 42 Independent; Single Paddy, Large (2x10-inch, -63 gram) 109 Interdependent; Two Paddy (40-inch on underlayment, 20-inch at tile Concrete _ #3 overlap) 40 Clay Barrel 114 2x10-inch x -35 gram for pans; 2 @ 1x10-inch x `17 gram for cap 147 Concrete Barrel 114 2x10-inch x -35 gram for pans; 2 @ 1x10-inch x -17 gram for cap 107 Clay Cap atop 2x 45 Independent: Continuous Paddy (^34 gram/ft) 135 stringer Concrete Cap atop 2x #5 Independent: Continuous Paddy (- 34 gram/ft) 116 stringer ClayCap atop 2x t16 Interdependent: 105 stringer Head: One (1) 410 x 2%" screw; Overlap: 1 x 6 inch (" 10.5 gram) Concrete Cap atop 2x #6 Interdependent: 76 stringer Head: One (1) 1110 x 2Y2" screw; Overlap: 1 x 6 inch (-10.5 gram) NEMO ETC, LLC Evaluation Report 02758.03.06-R9 Cerrificufe ofAurhorizaIion 932455 71" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POtYSET® AH-160 Revision 9: 09/29/2020 Page 3 of 10 NNEMOJetc. 5.7.1 Data in Table 1 relates to installation over a TWO-PLY underlayment system, as detailed in the FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, using a hot -asphalt -applied, ASTM D6380, Class M cap sheet (commonly called a '30/90 system'). Alternate underlayment systems are those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction, listed specifically for use with POLYSET® AH-160. 5.7.2 Tile roof systems using Uie types or profiles other than those listed above acquiring acceptance for use with POLYSET® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent multi -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. 5.8 Hip and ridge tiles using POLYSETO AH-160 are limited to projects having hip/ridge design pressure requirements, Table 1A of FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or the applicable design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3, not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2: Hip & RIDGE TILES IN POLYSETO AH-160 ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA MARGINS OF SAFETY ALREADY APPLIED) Placement Avowable Tile Substrate Detail Attachment Details Design (Section 10) Pressure (psf) Clay 2x PT ridge board its Independent: Continuous Paddy ("34 116 gram/ft) Concrete 2x PT ridge board #5 Independent: Continuous Paddy (" 34 107 gram/ft) Clay 2x P7 ridge board !f6 Interdependent: Head: One (1) #10 x 2'/2" 90 screw; Overlap: 1 x 6 inch (-10.5 gram) Concrete 2x PT ridge board #6 Interdependent; Head: One (1) #10 x 2%" 56 screw; Overlap: 1 x 6 inch ("'1D.5 gram) Clay or East Coast Metals "Trim Lock*"" (FL5374): independent: Continuous Paddy ("34 Concrete aluminum, GalvalumeW or stainless steel 45 gram/ft) 173 Clay East Coast Metals "Trim Lock'"' Plus" Independent: Continuous Paddy (" 34 Concrete te (FL5374): aluminum, GalvalumeW or Ii5 gram/ft} 178 starless steel Clay Ridged Systems "Top Notch" (FL8095) H5 Independent: Continuous Paddy {" 32 125 gram/ft) Concrete Ridged Systems "Top Notch" (FL8095) #5 Independent: Continuous Paddy {" 32 146 gram/ft) NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificore of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSETv AH-16.0 Revision 9: 09/29/2020 Page 4 of 10 NNEMO I etc. 6.: INSTALLATION: 6.1 POLYSET- AH-160 and the tile roof assembly shall be installed in accordance with the manufacturers' current published instructions, but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, subject to the limitations in Section 5. 6.1.1 Installation of POLYSET® AH-160 shall be performed by applicators that hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 6.2 Underlayment shall hold current Florida Product Approval for use with the roofing systems. The underlayment Product Approval shall specify allowable use with POLYSET® AH-160. The underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 6.3 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Monuol, Sixth Edition. Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Cer[ificare of Aurho,lzation #32455 7'" LDITIQN (2oZP) FBC NoN-HVHZ EVALUATION FL6332-R9 POLYSETm AK-160 Revision 9: 09/29/2020 Page 5 of 10 10.1 LDETAIL #1: Independent, Medium Paddy: Nail through plastic cement Paddy (Beneath Tiilei (when required) Underlayment R 7m - / Battens optional Eave Course - �`2 itr Fascia Eave Closure Flat/Low Profile Tile NNEMO I etc. Nail through plastic cement (when required) =-- Paddy (Beneath Tile) ��- Underlaymen_I 2 In. Battens optional T �� 10 In, Eave Closure Eave Course ®�� Fascia Medium Pro€ileTile Nail through plastic ce ent-11 (when requited) Paddy (Beneath Tile) Underlayment\ 1_. ell, ,t Battensoptional � �\ , ��;.r ! Eave Course —_ �` " / Fascia Weephole loin. \ tin. % Eave closure Drip edge High Profile Tile NEMO ETC, LLC Evaluation Report 02768.03.06-119 Certificate of Authorimtiaa #32455 77H EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-Rg POLVSET° AH-160 Revision 9: 09/29/2020 Page 6 of 10 ONEMOjetc. 10.2 DETAIL tit: independent, Large Paddy: Nail through plastic cement {when required) Underlayment c 10 in��� \• Battens optional ° Eave Course loin. Eave Closure Paddy (Beneath Tile) Flat/Low Profile Tile Nail through plastic cement (when required) / \` Paddy (Beneath Tile) Underlayment I 10in. .x 2 itional Battens ope. tional i �• - loin << tin. Ft `\ ErT % Eave Closure Eave Course `-- Fascia Medium Profile Tile Nail through plastic cer nt- (when required) Paddy (Beneath Tile) jfUnderlayment 10in.x \ `_• 2 in. wide Battens �� \��•_. t/f optional Eave Course -_ / fascia Weep hole loin. �2 in. Eave closure i Drip edge High Profile Tile NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificote of Authorization 432455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSEV AM-160 Revision 9: 09/29/ZOZO Page 7 of 10 10.3 DETAIL #3: Interdependent, Two Paddy: Nail through plastic Cement Paddy Ihetween tiles) (when required) 1 I Battens optional ° I Paddy(underxile) on top of tile �4x4in.\' S!In g[to paddy under tit Single paddy on undarlayment 2 x 4 in. Fascia \\ Eave Closure Flat/Low Profile Tile Nail through plastic <et7 (when required) r i Ball M optional `� e N EMO I etc. Nail through plastic cement Single paddy under the (when required) %\ Paddy (between tiles) Battens J �Y Paddy {under tile) optional o �� Si ng(e paddy an top of 17e 4x4in. / 2x4in. Single paddy on and wlayment\ 10in. In Eave Closure Eave Course\— Fascia Medium Profile Tile Single paddy undertile Paddy lbetween tiles} Paddy tunder ulel 7onu_ntlierlayme t 4x4in, / �f Single 2x4te../ paddyon top nttile �' Eave Con rse\`� 14 in\ 2 in. High ProfiieTile X Weephole Eaveclosure Drip edge NEMO ETC, LLC Evaluation Report CZ768.03.06-R9 Certificate ofAutharization #32455 7ri EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-Rg POLYSETe AH-160 Revision 9: 09/29/2020 Page 8of10 10.4 DETAIL #4: Two Piece Barrel (Cap & Pan) Tile: 1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications in contact with the pan tile. (when required) 2) Torn Covers upslde down. Plaoe adhesive 112 to. to i in in frpm ootsido edge of cover tile. install cover ta.. Ensure 20 to 25 cq, in. contact area an each 5100 of Omer tile. Underlayment Eave closure Imotar shown) Weephole Fascia Board Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile 10.5 DETAIL #5: Hip and Ridge (independent placement): A bead ol'IeP Pu]}+r18 A11-16U um} be app5ec aL+u a :hc lira 'To attach h:findgr lik._ a hear) of ICP i+uly'ulxA}t.1 60 wa} tilo 5111ts:e eu bot? vices of the hip.tidge Lward or griMLL tC nr silpLed dqu i Ih. C; lire PI the h]I+.lxlur M+ard xc.ahmind attest flour to pi 0%ide"ealheEhlucknia. o7ose. NEMO ETC, LLC Certificate of Authorization 43,7455 7" EDITION (2020) FBC NON-HVHZ EVALUATION POLYSETm AH-160 ONEMO I etc. +rrrh hM id7.•. rde,. 411tl et r('P PO--Ji Ml-?+x mar hr11�b,d ihr 114 Ini,h O0, Is, rsrh i,rl; n-41m t%rh_hr 1 Wl- ar, du ...«.I .f Id - Evaluation Report 02768.03.06-R9 FL6332-R9 Revision 9: 09/29/2020 Page 9 of 10 10.6 - END OF EVALUATION REPORT - NNEMO I etc. NEMO ETC, U-C Evaluation Report 0276B.03.06-R9 Certificate of Authorim(lon #32455 71" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-119 POLYSET® AH-160 Revision 9: 09/29/2020 Page 10 of 10