HomeMy WebLinkAboutReview - CommentsPlanning & Development Urvices Building & Code Regulation Clmsion 23H Wginla Avonue Fort Pierce, FL, U992 PROPERTY INFORMATION Address: 8027 Plantation Lakes Dr City 1 State 1 Zip: Port St Lucie, FI 34986 Parcel #: 3321-803-0049-00015 Zoning: RS-2 APPLICATION INFORMATION Permit Number: 2202-0565 Permit Type: ROOF - TILE CONTRACTOR INFORMATION Contractor Name: Jeffrey J Hampson Business Name: St Lucie Roofing Inc Business Addr: 1919 Sw South Macedo Blvd City I State I Zip: Port St Lucie, FI 34984 REVIEWS AND COMMENTS Review Type Status FRONT COUNTER REVIEW COMPLETE Comment: NOTIFIED FOR PICK UP PENDING REVIEW COMMENTS Owner(s): Frank L Baker 1 Gigi Navarro Jurisdiction_ SAINT LUCIE COUNTY Lot#: 45 Block: Reviewed By Ellen Vaughn Ellen Vaughn 1 Stories: Automatic Sprinkler System? No Fax Number: 772-207-7354 Email: Jeffh.Slr@Gmail.Corn; Slroof ingoffice@Gmail.Com Date Started Date Completed Date Released 2/21/2022 2/21/2022 2/21/2022 Comment: PLANS EXAMINER REVIEW INCOMPLETE Joseph Fersch 3/2/2022 3/2/2022 Comment: THE SUBMITTED ST. LUCIE COUNTY ROOF INFORMATION SHEET SECTION D IS INCOMPLETE SECTION E NOT SUBMITTED. SUBMITTED A COMPLETED FORM, 170.2 FBC 2020 7TH ED ST. LU IE Section A (General Information) Master Permit No. Process No. Contractors Name: (_�& L,(_A_C'-'j ,jT M ( License # coo [ Y SO LP Job Address �e`t V) ate,J ( Y L ❑ Low Slope ❑ Asphaltic Shingles ❑ New roof ❑ Repair Low Slope Roof Area (SF) Sketch Roof Plan Inclur' i ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panei/Shingles ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE_ q�'Mortar/Adhesive Set Tiles ❑Wood Shingles/Shakes ❑ Maintenance Reroofing -ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 0 Recovering Total (SF) 31 -5 Section B (Roof Plan) Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. ,f parapets. t13 az C�J T LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: C 0 c1 O r>v4-e- Uz—. Notice of Acceptance Number: FL- {l �T j , OL — V j .3 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r: Deck Type: Type Underiayment: �{ Ti cr l t nd-e,, t mer+ r l.- ?J ! Roof Slupe: ' T z Insulation: Fire Barrier: Ridge Ventilation? Fastener Type &Spacing: e ` f Adhesive Type: p) fb+n -FL 3� Type Cap Sheet Mean Roof Height: 1 Roof Covering: CJnC -�t 'c Type & Size Drip J� Edge: t LICE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mrwith the values from Mf. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RAS 12T (Zone 1: x �Mg =Mn Product Approval M� (Zone 2e: . x l _ - Mg., = M . Product Approval Mf-- (Zone 2n: x lL _ Mg: = Mom, Product Approval Mr (Zone 2r: x 7t = ) - Mg: = Mr&Product Approval Mf (Zone 3e: xl _ -Mg: =Ma. Product Approval Mt (Zone 3r: x ), _ �� - M91 Me& Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" 1equired Moment of Resistance (Mr) From Table Below Product Approval Mr Mr required Moment Resistance` Mean Roof Height Roof Slope 15, 20' 25' 30' 40' 7:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. v i Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= ) -W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= ) -W: cos r =Fr2n Product Approval F' (Zone 2r: x L =x W:= ) -W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W:= ) -W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:= ) -W: cos r =Fr3r Product Approval F' Where to Obtain Information Description Symbol Where to find Dc sign Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 M pan Roof Height H Job Site Rc of Slope 6 Job Site Aerodynamic Multiplier A Product Approval RE storing Moment due to Gravity Ms Product Approval At achment Resistance Mf Product Approval ]t quired Moment Resistance Mg Calculated M nimum Attachment Resistance F' Product Approval R quired Uplift Resistance Fr Calculated Ax erage Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. M ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 www.flori(laenginceiiiil,,antltcstiiig.com 2.50 S.W.13`h Avenue Pompano Beach, FL 33069 DATE: 3/30/22 JOB ORDER #: 22-1364 CLIENT: St. Lucie Roofing ADDRESS: 1919 SW South Macedo Blvd. Port Saint Lucie FL 34984 PROJECT: Baker/Navarro Residence Boral Estate "S" Tile Roof ADDRESS: 8027 Plantation Lakes Drive Port Saint Lucie FL 34986 2020 FBC/ASCE 7-16 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Roof Height = Max. 15' Exposure: C Basic/Ultimate Wind Speed: V„ it=170 mph Length = 83' Category: 11 Nominal Wind Speed: Vssd=Vu1t*40.6 Width = 68' Slope: 6/12 = 26.6° (asd = allowable strength design) Residential Hip Roof K, = 0.85, Kzt — 1.0, Ka — 0.85 For multiple deck condition, the most conservative dimensions were utilized for design talcs. Design Calculations: Velocity Pressure: q = 0.00256*K K tKdKeVZ Velocity Pressure (,It): q-=0.00256(0.85)(1.0)(0.85)(1.0)(170)2 — 53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(1.0)(170*40.6)2 = 32.07 psf Width of Pressure Coefficient: 0.1(68') — 6.8' 0.4(15') = 6.0' } use: 6'0" For hip roofs with a roof slope of 25 degrees or less, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: GCP1 rn -1.4 GCP2e = -2.0 GCP2r = -2-0 GCP3 = -2.0 GCP,,3 = -3.1 Internal Pressure Coefficient: GCPi 0.18 Figure 30.3-2G 74 AV, .07 *A t!` V Qualiir,/ `{fir .Issrcrunc 10 Page 2, 3/30/22, Job Order # 22-1364 St. Lucie Roofing - Baker/Navarro Residence Boral Estate "S" Tile Roof 8027 Plantation Lakes Drive; Port Saint Lucie, FL: Desien Pressures Based on Vasd: Field P1 — 32.07*[(-1.4) — (0.18)] = -50.7 psf Perimeter (Ridge) P2e — 32.07*[(-2.0) — (0.18)] = -69.9 psf Perimeter (Edge) P2r — 32.07*[(-2.0) — (0.18)] = -69.9 psf Corners P3 = 3107*[(-2.0) — (0.18)] = -69.9 psf Max. Overhang P3o„3 = 32.07*[(-3.1) — (0.18)] = -105.2 psf Attachment Requirements Per RAS-117 (Boral Esate "S" Roof Tile): Tile System: Moment Based Aerodynamic Multiplier: 0.289 ft3 (Direct Deck Application - Table 2) Restoring moment due to gravity: Mg = 6.33 ft-lbf (Direct Deck Application - Table 3) Attachment resistance expressed as a moment: Mf= 26.1 ft-lbf for two (2) patties (8 grains/patty) of ICP Adhesives Polyset AH-160 Field Mri = (50.7*0.289) — 6.33 ft. lb = 8.3 ft. lb. < 26.1 ft. lb = PASS Perimeter (Ridge) Mr2r = (69.9*0.289) 6.33 ft. lb = 13.9 ft. lb. < 26.1 ft. lb = PASS Perimeter (Edge) Mr2e = (69.9*0.289) — 6.33 ft. lb = 13.9 ft. lb. < 26.1 ft. lb — PASS Corners Mr3 = (69.9*0.289) — 6.33 ft. lb = 13.9 ft. lb. < 26.1 ft. lb = PASS Max. Overhang Mr,,,,3 = (105.2*0.289) — 6.33 ft. lb = 24.1 ft. lb. < 26.1 ft. lb = PASS System is acceptable as approved with two (2) patties (8 grams/patty) of ICP Adhesives Polyset AU-160 based on the requirements of NOA # 21-0323.05. Notes: • Corners and perimeter area dimension shall not be less than a — 60" • Additional testing (for example TAS-105, TAS-124, TAS-126) may be required by the building department and/or the NOA/product approval for the installation of the above roof system. Client must verify directly. FE&T can perform these additional tests, upon request. • Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). • All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2020 Edition. • Wind load calculations based on ASCE 7-16, 2020 FBC, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. • All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, Mohammad Reza -59r 11y.y do y oba d Reza Randly JaW�dn RaffatyJavidan oaM;zozzon.oiioai,zs-0•oa Reza 7avidan, P.E. Florida Engineering & Testing, Inc. Florida Reg. No. 60223 Certificate of Authorization No. 6923