Loading...
HomeMy WebLinkAboutTruss Placement Plan38-8- 19'-0' E A10G AB AG A A4 A3 e'-8' CL4 e'-a• CL4 A2 A1A $PACE A/c A2 A3 A4 a'-8• CLG e R CLn. A5 A7 A9 ABG NEJ7A ac B2GE CIGE I - 19'-4' '-0' 4'-4' '-0' I1'-0' Total Truss Quantity = 69. REIVIEED L- I G , Pr" 01-13 6S THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT. REFER TO PACK FOR CONNECTION. CJ5 1 CJ3 `t'� CJ PLUMB TYPICAL 7' SETBACK CORNERSET LABELIN AND SPACING SHINGLE ROOF 12 6 2XA _ HEEL4-3/1 " 12 0 a for Code Universal Engin $§ClenCes NOTE: MULTI -PLY GIRDER CONNECTION. ALL PLIES SHALL BE FASTEND TOGETHER (BOLTS, NAILS, AND OR SCREWS) PRIOR TO INSTALATION AND BEFORE ANY LOADS ARE APPLIED. PER THE SUPPLIED ENGINEERING SHEETS. NOTE: DO NOT CUT OR ALTER TRUSSES WITHOUT CONSENT OF THIS OFFICE. BACK CHARGES WILL NOT BE ACCEPTED WITHOUT PRIOR WRITTEN APPROVAL BY OUR SERVICE DEPARTMENT AT CARPENTER CONTRACTORS OF AMERICA, INC. 877-293-9487 NOTE: ALL BEARING WALLS MUST BE ADEQUATELY ➢ESIGNE➢ TO CARRY THE LOADS IMPOSED BY THE TRUSS OR TRUSSES, AND MUST BE INPLACE AND IN SERVICE BEFORE THE TRUSSES ARE SET IN ORDER TO AVOID REPAIRS. Labeled End Mark MOMS, General Notes 1) All parallel chord trusses, flat trusses and flat girders have the top chord partially pointed green to be installed green side up. 2) All hangers to be Simpson HUS26 unless otherwise noted. 3) All truss spacing is 24' O.C. unless otherwise noted. 4) Per Truss Plate Institute BCSI-Bl recommendation permanent X-brocing should be placed at o maximum spacing 15' O.C. across the span, to be repeated of a maximum of 20' between each X-brace throughout the structure. Please refer to SCSI-Bl for any additional bracing details. ROOF LOADING SCHEDULE TCLL = 20 PSF TCDL = 7 PSF BCDL 10 PSF TOTAL = 37 PSF DURATION = 1.25 % WIND SPD/TYPE= 160 ENCLOSED BLDG EXPOSURE = C USAGE=RESIDENTIAL CAT II WIND IMPORTANCE FACTOR= 1 UPLIFTS BASED ON= 9.2 PSF DESIGN CRITERIA FBC 2020 TPI 2014 Truss member design & connector plates are desired for ABCE 7-16 and maximum forces Gam both components and claddings andmain,nma forceresistingsystems. • These trusses have beenreviewed to cazry an additional 10# psf non-Concu¢ent bottom chord live load ETCD R LOADING SCHE= PSF= PSF = JULPSF ROOF DESIGNED FOR SHINGLE ALL REACTIONS AND UPLIFTS ARE SHOWN ON ENGINEERING WALL KEY 06'-8' LOAD# DESCRIPTION INIT. DATE R/al ENG NEW as RVN 2/1a/14 INFO 34111, Real R—CO VALLEY TROSSESREP a 4/3/14 RAN NEW NO EW 'C' NNT s1a 4 ROC[ COPY 7DL RAN NEW WIND NNT 7/14/14 REo3 LCa RW n/14- RF01 DPI NriW]0 ROAHL ]PS YDe Da C RPS RFo1 9—a PREW SaPPLIER LARELSROP 87 LOAD# DESCRIPTION IN IT. DATE RFaf LC9 LPN E45/18 9/la/19 RG RELADEL PROJECT NNT 117— R10INEW Ca DE 2D20 nL. u/12/20 �1 I 01 NCARPENTER -- CONTRACTORS OF AMERICA 390D AVENUE G. N.W. WINTER HAVEN FLORIDA 33880 PHONE:(800) 959-8806 FAX: (963) 294-2488 BUILDER D.R. HORTON STATEWIDE PROJECTCREEKSIDE MODEL 1672/ARIA/4EAB CCA PROJ/MODEL/ALT 7A5/ 320/167BD ALT DESC OTC %L 99 BLOCK DESIGNER PAGE RFS 1 DATE 3 29 17 LAN# N333986L SCALE 1 4 "=1'