Loading...
HomeMy WebLinkAboutNOA-021/17122, 12:13 PM Florida Building Code Online Business ♦Professional Regulation SCIS Home j log In j Uwr Registration � Hot lbpict i SubMit Surcharge � Stats a Facts 1 Publications contact s SCiS site Map I Funks i Search {, ;•l Product Approval USER: Pubkc User Vro t nkpr®val menu > Product or Ap luation 5e arch > .j;yj&t�on �;41 > Appilcetlon Detail FL # FL9063-R9 Application Type Affirmation Code Version 2020 Application Status Approved Comments Archived Product Manufacturer CGI Windows and Doors Address/Phone/Email 10100 NW 25 Street Miami, FL 33172 (305) 593-6590 Lmiller@pgtindustries.com Authorized Signature lens Rosowski jrosowski@pgtindustries.corn Technical Representative Lynn Miller, P.E. Address/Phone/Email 1070 Technology Dr N Venice, FL 34275 (941) 486-0100 Ext21142 Imi Ilerft9tindustries.com Quality Assurance Representative Address/Phone/Email Category windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency Miami -Dade BCCO • CER Validated By Miami -Dade BCCO - VAL Referenced Standard and Year (of Standard) Standard yM FBC - TAS 201 1994 FBC - TAS 202 1994 FBC - TAS 203 1994 Equivalence of Product Standards Certified By I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes No N/A https://www.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwt0qu2%2bUbuy%2lencsMezRilFC981SEVvSGlxl%3d 1/3 1/17/22.12:13 PM Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted Date Validated Date Pending FBC Approval Date Approved 11/05/2020 11/05/2020 11/11/2020 FL I Model, Number or Name Description 9063.1 ^_ Series 130 Aluminum Fixed Window I Large Missile Impact Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistants Yes Design Pressure: N/A Other: Please see Miami -Dade County Notice of Acceptance (NOA) for Product performance information, anchorage details, and anchor type, size, and spacing Information. 9063.2 1 Series 130 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZt Yes Impact Resistant: Yes Design Pressure: N/A Other; Please see Miami -Dade County Notice of Acceptance (NOA) for product performance Information, anchorage details, and anchor type, size, and spacing Information. Corti notation Agency CertHcate FL9063 B9 C CAC0.0519 09 LMI,R%jf Qusllty Assurance Contract Explration Ditto 09/22/2025 Installation Instructions FL9063 Rg 17 20,019,09 1 M odf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Certification Agency Certificate �063 R9 rer 20-0 19 O8 M2 odf Qusllty Assurance Contract Expiration Date 07/31/2024 Installation Instructions FL9063 R9 II 20-0519 08 SMI g�[ Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Series 238 Aluminum Designer Fixed I Large Missile Impact Window Limits of Use - _-- Approved for use In HVHZ: Yes Approved for use outside HVHZ; Yes Impact Resistant: Yes Design Pressure: N/A Other: Please see Mlaml-Dade County Notice of Acceptance (NOA) for product performance information, anchorage details, and anchor type, size, and spacing Information. Series 238 Aluminum Fixed Window Certification Agency Certificate FL9063 R9 CA0.21 n D d1 = Quality Assurance Contract Expiration Date 10/20/2023 Installation Instructions F 9061 Rg II 0-OS 19 05 D gj(jDALpX Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Missile Impact Limps of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL9063 Rg C CAC0.115106 war Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/26/2023 Design Pressure: N/A Installation Instructions Other: Please see Mlaml-Dade County Notice of Acceptance FL9063 R9 II 20-0519 06 odf (NOA) for product performance information, anchorage details, Venfled By: Miami -Dade BCCO - CER and anchor type, size, and spacing Information. Created by Independent Third Party: Evaluation Reports _ Created by Independent Third Party: 9063.5 I Series 410 Aluminum Fixed Window Large Missile impact Limits of Use Approved for use In HVHZ; Yes Certification Agency Certificate FL9063 Approved for use outside HVHZ: Yes R9 r CAC 20-0519.11 1 MI pol Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/03/2024 Design Pressure: N/A Installation Instructions Other: Please see Miami -Dade County Notice of Acceptance FL9063 119 17 20-0419 11 LMI.ndf (NOA) for product performance Information, anchorage details, Verified By: Miami -Dade BCCO - CER and anchor type, size, and spacing Information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 9063.6 I Series 410 Aluminum Fixed Window I Small Missile Impact Limits of use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Certification Agency Certificate FL9063 R9 C CAC0-051 SO SMI.pff Quality Assurance Contract Expiration Date httPs://www.floddebuilding.org/pr/pr�_app dtl.aspx7param=wGEVXQwtDqu2%2bUbuy%21encsMezRll Fcg6lBEVvSGixl%3d 2/3 1/17/22, 12:13 PM Florida Building Code Online Impact Resistants Yes Design Pressure: N/A Other: Please see Miami -Dade County Notice of Acceptance (NOA) for product performance Information, anchorage details, and anchor type, size, and spacing Information. 9063.7 Series 7500 Vinyl fixed Window Limits of use Approved for use in HVHI: Yes Approved for use outside HVH2: Yes Impact Resistant: Yes Design Pressure: N/A Other: Please see Miaml-Dade County Notice of Acceptance (NOA) for product performance information, anchorage details, and anchor type, size, and spacing Information. 06/03/2024 Installation Instructions F 9061 R9 IT 70 0 Iq 10 c, ' gg[ Milieu By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Large Missile Impact Certification Agency Certificate F O6 0.g r rer 7n-nrao 07 RAf Quality Assurance Contract Expiration Date 02/20/2024 Installation Instructions F_L9063 R9 II 70.O51g m p�( Verified By; Miami -Dade BCCO - CER Created by Independent Third Party; Evaluation Reports Created by Independent Third Party: z. Nov[ Conn"' Ile ;; JRgI emir etn R d lLll h Phnne 8e0-411• 87 The State Of Florida Is an WEEC) employer. raevdehr J8d7•Jn + ! k ;; Dnvacv s_�.r.m.nt ;: Acresgb WX c . ,., e _�,� ;: eehme statement Flo ida 811 to his ant law, email , ddressescontact t are Publoffice b p records. It by t do c not want your small add ress "deased In response to a Public -records request, do not send elecoOrIc mFlordaoll to this entity. Instead, contact the 12, l ce Deanece se trunder C mall. 4 you have any questions, Please contact 850,487.1395. 'Pursuant to Section 455.275(1), Provided d may b Bused hi October 1, muni licensees Ntenzetl under Chapter emai F.S. dmust provide the Department with an email address If they have one. The emads pmNdet may be used far with an communication with the e made However email addresses are public record. If you do not wish to supply a personal address, Please Provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., Please dick LCR. Produce approval subseptu ®®®R■ Credit Card sale https://www.floridabuilding.org/pr/pr app_dtl.aspx7param=wGEVXQvADqu2%2bUbuy%-lencoMezRilFogSIBEVvSGlxi*/o3d 313 MIAMFnADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315.2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building CGI Windows and Doors, Inc. 3780 W 100 Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Sentinel 130" Aluminum Fixed Window— L.M.I. APPROVAL DOCUMENT: Drawing No. PW130LMI-NOA, titled "`Sentinel' Series 130 Fixed Window - LM", sheets I through 7 of 7, dated 05/22/19, with revision A dated 05/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 19-0603.02 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 20-0519.09 Expiration Date: September 22, 2025 Approval Date: October 10, 2020 8/31/20 Page 1 CGI Windows and Doors. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 10-0510. 13) 2. Drawing No. PW130LMI-NOA, titled "Sentinel 130 Alum Fixed Window (L.M.I.)(S.M.I.)", sheets 1 through 7 of 7, dated 05/22/19, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 560 aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-19-8916, dated 04/10/19, signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No.19-0603.02) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Water Resistance Test, per FBC, TAS 202-94 3) Small Missile Impact Test per FBC, TAS 201-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 130 and 410 aluminum fixed windows, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-19-8917, dated 04/09/19, signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No.19-0603.02) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0413.03) Manuel Pe Product Control E J NOA No.2U Expiration Date: September Approval Date: October E-1 CGI Windows and Doors. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) B. TESTS (CONTINUED) 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer(& insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0413.03) 5. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal& and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0413.03) 6. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a Sentinel 130 aluminum fixed window, prepared by Hurricane Test Laboratory, Test Report No. HTL 0080-0130-10, dated 03/30/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.13) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6`h Edition (2017), dated July 15, 2017, prepared by AI-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-0918.07) 2. Glazing complies with ASTM E1300-09. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) Product Control E .J NOA No. 20 Expiration Date: September Approval Date: October E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. 2. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "TrosifolO Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18,expiring on 12/11/23. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 61h Edition (2017), dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 2. Statement letter of no financial interest, dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 3. Proposal No. 19-0219 issued by the Product Control Section, dated March 13, 2019, signed by Ishaq Chanda, P.E. (Submitted under NOA No.19-0603.02) 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated May 22, 2019, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 5. Laboratory compliance letter for Test Report No. HTL-0080-0103-10, issued by Hurricane Test Laboratory, LLC, dated March 30, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.13) 6. Test Proposal for the qualification of Butacite® PVB glass interlayer by Kuraray America, Inc., as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, P. pe isor, Product n r ection. (Submitted under NOA No.15-0413.03) )/pA././ /O t . OA AA Product Control E NOA No. 20 Expiration Date: September Approval Date: October E-3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) G. OTHERS 1. Notice of Acceptance No. 17-0918.07, issued to CGI Windows and Doors, Inc. for their Series "Sentinel 130" Aluminum Fixed Window - L.M.I. approved on 11/22/17 and expiring on 09/22/20. 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. PW130LMI-NOA, titled "`Sentinel' Series 130 Fixed Window - LM", sheets 1 through 7 of 7, dated 05/22/19, with revision A dated 05/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: l) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all PGT Industries, Inc. CGI Windows and Doors, Inc., representative units listed below and tested to qualify Dowsi1791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: PGT Industries. Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by ldalmis Ortega, P.E. CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit I in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal) all dated 08/24/20 and signed and sealed by Ioalmis Ortega, RE �1 Manuel Pe Product Control E NOA No. 2U Expiration Date: September Approval Date: October E-4 CGI Windows and Doors. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED tCONTINUDI C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 61h Edition (2017), dated 07/15/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., updated to comply with FBC 7th Edition (2020), on 05/11/20 by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 61 Edition (2017), and FBC 71h Edition (2020), dated May 07, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated May 07, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 1.0, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 19-0603.02, issued to CGI Windows and Doors, Inc. for their Series "Sentinel 130" Aluminum Fixed Window - L.M.I. approved on 07/03/19 and expiring on 09/22/20. Manuel Pe Product Control E J NOA No. 20 Expiration Date: September Approval Date: October E-5 3� TYPICAL ELEVATIONS LAM. GLASS INSULATING IAM.GLASS ANCHOR SPACING SHOWN HEREIN APPLICABLE SMALL MISSILE IMPACT TO FLANGE AND FLUSH FRAMES. SEE SHEET 2 FOR FIN FRAMES. IABBE MSSILE IMPACT Ag =L=J— a DORMERS STRVfilf 90E5 - Wfi✓IIGW MDIM , WMDOM IMPIN , WIN" "m 6• MAK tY YAK � � � � � �' R��KL SHd B CORNERS WINDOW IMMIN £� W, �D.W�TN , W6R�WMDT WW�RT APPROVAL APPLIES TO SINGLE DESIGN OR SIDE NT SIDE CWINDIWS OR OF LION A . OR FIX. WOW. • � 3 WITH OTHER MNMI-DADE COUNTY APPROVED WINDOWS USING MLAMI-DARE COUNTY APPROVED ! I� MUWONS IN BETWEEN. LOWER DESIGN PRESSURE MOM WINDOWS OR WLL1pN APPROVAL 3 3i-1L� WILL APPLY 1D ENTIRE SYSTEM. FIAN6E WIDTH D.L OPG. ' ,B' MAIL e' MA%. IEAD/su CORHwS T6asHORrEn SIDES —4-- Ir im SERIES 130 SENTINEL ALUMINUM FIXED WINDOW - LMI DESIGN LOAD RATINGS FOR THESE WDmO'WS TO BE AS PER CHARTS SHOWN ON SHEET 2. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE W. WIDTH 2017 (STH EDITION) R 2020 (77H EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELODW HURRICANE ZONE (HVHZ). THESE WINDOWS ARE RATED FOR LARGE B SMALL MISSILE IMPACT. SHUTTERS ME NOT REQUIRED 1BY OR 2BY WOOD BUCKS k BUCK FASTENERS BY OTHERS, MUST BE DESIGNED MD INSTALLED ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SDLLME OR RECFANGLE AS SHOWN IN DOTED LINES AND OBTAIMMG ALLOWABLE LOADS FROM THOSE SHAPES. ADEOMATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE ANCHORS SHALL BE CORROSON RESISIANF. SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT To BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR srucco. "SENTINEL" IRPRM RetlPbol Impad .ttlirrrr �� ANY LYNIV ' ``'Ca A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT. NON-METALLIC AND NON -COMPRESSIBLE SERIES 130 FIXED WINDOW - LM AGK 601IHs ...DENSE �: are WWWWWWWr . F 7_ MATERIALS INCLUDING BUT NOT UMFIED TO STEEL/METAL SCREW$. THAT COME INTO CONTACT MODUCT TYPICAL ELEVATIONS OMMI9 ••MN •""u.u.n r. m• %w •a••• •....,,.M, *: Mo 705 .P 1Y WITH OTHER DISSIMILAR MATEBWS SHALL MEET THE REQIIIREMEMS OF ME 2017/2020 �� D"WAW _ G FLORIN BLOC. CODE &ADOPTED STANDARDS. &iMiq Red � 2o.o5W0.09 RMbr: Ib" Wj: M. p%r PREPARED BY LYNNMILLER p ` � THIS PRODUCT APPROVAL IS GENERIC AND GOES NOT PROVIDE INFORMATION FOR A SITE 25 ANCHOR TYPES, UPDATED TO FBC 2020 JR OSID720 lomwe NOLDGYDRNE N.VFNICE.FL3 5 ' O ATE oc W, ADEQUACY STRUCTURE RECEIVING SPECIFIC PROJECT. i.e.SLIFE SAFETY OF THIS PRODUCT.FOR WATER TI THIS PRODUCT MO SEALWIG MOUND OPENING FOR WATER INFlL11AllpN RESISTANCE EEC. CONDTFo NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED sme s.s ePW xn d•' (RNUN80.,600 ' .AS/ANAL EN ••n SEPARATELY, AND TO BE M mw '�•�"' Br BULnwc PmA PW-130 LM NTS 1 OF 7 PW130LMI-NOA A rLIFILPE}1P.E><SWIRfi REVIEWEDaEElcw_ REG! TION ALI•WN MI TYPICAL ELEVATIONS ANCHOR SPACING SHOWN HEREIN APPI "M F M FlM FRAMES N' tAKK WORT O.L OPG I SIpES 18' WKW%.y I �SIDES;� I I HFID/SLL CANID6 II II x ' ,o II II _ L= A II II I -�_ +�-8' �+ TYP. FIN FRAME DAYLI!E OPENINGS: D.LO. HEIGHT = BUCK HEIGHT — 3.00- D.LO. MOTH — BUCK WIDTH — 3.00' _ 4_4 II II II II _ram_ -ram_ ilL —tII = L=JL=A_ II II � � II II SRYANR HEAD/6Rl 6TILVNR SD6 CORNERS SKIS TYP. FIN FRAME TYP, FIN FRAME ALTERNATE SHAPES AS SHOWN ON SlfriT 1 ALSO AVAILABLE FOR FIN FRAMES 'SENTINEL" SERIES 130 FIXED WINDOW -LM AGK IDpxlTk&Dom ®wlRm.a a DOM: .nemwa- o®perc o.M PRODUCTREVISED TYPICAL ELEVATIONT CONT. 051mig •••�••••- •d•••••=.w •': ' F^�•�V)vFe w11I, Rye FIp1Y OAa1w.CaG ZO-0BT B.OB Be IN MINOR SHEET REFORMATTING. Rw.M JR RFrlk�5/07 05Po7Y20 PREPARED BY NOLL NMILLE 107ENKE,FL a0YOf6v6 N. VERILF—FL�6 WFr Wr• L6F1)+ Ieoo s.i./M� se,� swee m. PW-130 LM NTS 2 OF 7 PW130LMI-NOA A REgBTRATIQRF7>�e LAM. GLASS INSULARNG LAM.GLASS SMALL MISSILE IMPACT LARGE MISSILE IMPACT * N. 58705 _ =A'. S 24• w ]C 4r M' a4• Bl• �. 2Y 29• w 41• ar BY W 3s• BOA WA W.0 I no WA Ma WO m0 WA WO WA WO m0 m0 WA BOA WA ma 4F0 mo ma mo mA no m0 m0 BOB m0 mA m0 ma no M' 30' Y' 4r 4B' 6C W 61' 46• W' 2T 26' W' 1. 4r w W 4r BIJ m0 Bo.O m0 MA no BO a WD WA no Wa m0 WA— )02 701 mo Wa eu mJ no no 812 613 MA m.o 612 e13 mA WA 612 MA m0 ]o' ]B' 42' w 64• m. 2B• $ 41• 1]' sr W' 8P m. m0 no mo ma WA mA WA j"2:7U no BOA mA mA n3m• m,61 460 0.1 ml 24 311' 31• 44' 4B' 51• W' 61 ]r 2J' p $' 41' 4r 6T W' W ]l. WA W.0 W.0 mA WA BOA MA m0 mA BOA MA m0 RR ]03 no no 613 el3 W.0 no 643 x3 TLs 7M 48A 46B 611 0.1 460 46D 61A 64A 2a• 30• Y' 4r 48• w w Be 2J' i 15• 41 4r sr W" W. BOA no no WA WA Wa no no 762 m no mO no "A m0 no 61J e1J m0 WA su a43 n3 n3 W4 1 54 1 WA WA 24' W 36 ar 4B• 49• 9r 2]' 29' W ar ar 46• q. no MA M. WA m0 Wa no WA T ]6A mA mA W2 a53 MA WA we me WA no WA W.e mA MA 2r m• w 4r w 1w 23' b' b' 41' 4r lOr no WA m0 WA m0 WA W.0 BOA 7" 144 WO no 0.7 m7 W.o no W3 Bo3 m0 WA 20 SIY Sr 4r Im' 'd 2Y ss• 41- 16r mA MG mA WA WA ma W.o WA M 739 WA mA W4 W4 W.0 eoo �Wmwr -m nANee m6 m86 ➢00. m888 i Y6'81' 6 i W&W enDt M ,u+on+ N emx M 1Dlop1 (U M.(.) lW(-) w(+) ,W(-) 24• Y' 114 23' �• w 11Y BJp WA m0 WA WD WA m0 no AD M0 WA mA 81A 61A mo WA 24' W I6' 1w 23' g S' IIV WA BOA no mo m0 MA mo WA T14 M4 m0 m0 WA 6M WA mo 24• W M. W 121' 2Y 2r ss• Sr 1R0• WA m0 m0 WA WA WA m0 WA ns ]2s W.0 no WA axe mD eon FL1r1GE A6o0 1j' IYP. BAIX Oe15 K' TP. FIANGE FRAME BIICI( olA6—� EGUAL LEG FRAME eoCK DIMS-� FIN FRAME DANGE AWS r--6ucx W�5 NOIC GUm oAPACa6 ON MR SHFET AOE FUNGE ADAPTOR FRAME BASW ax Arn G co (3 N cusrs) ND fl VW WAaO COMW - OECIAM70M SfAIYFM pCV16-DEC-210 oLx06 ®I6. BOR ®W. BIA® ]YP88 Y6'a' 0{88B f!!Y b'6'B,' '601N M Um" 6UM Do 1EN N W4.) 1W(-) W(4) iW.(-) JY 4r 6 llr 61' 26 W 4r W-1/8• W" .� ma M0 no me WA WA WA W.0 boa MD WA no no mA BOA no WA Woo Wa no WA m0 WA WA 2Y1/r 3r te• 6 '/B' 61• 38-3/r 2s-1/2' .M' 47• s2-1/6• 60' -�. m8 WA WA WA WA mo WA WA WA W.0 m0 n.l n.f Wo WA n.l n., Ma no n.l n.l WA Wa 16-1/e' 2B-1/r 3Ts�. b• al. ]8-1/r 4h3/r re-1/6• 1 1/2• 36• 4T W-,/B• m• 74 1/P Bz-3/a• p no no WC mo WA BOA Wa WA BOA WA W.o WA 8+J BIJ W.O m0 56p 680 nA n.4 36a M0 nA nA my Mo na ne ma mo 7" m 18-1/8' 28-,/r 4B• 61• ]6-,I4' IB-,/B ]s-+/z• 4r eo' 74-,/4 B06 WA m0 no WA mA WD mA WA WA WA WA 813 sr3 WA WA 460 aBA 8r.o W 46.6 4 6,A s19 16-f/C 2A-,n• 4Y 53-1/C 81' la-1/B' 2B-,/r tT 52-1/8' 60' m0 m0 WA WA Wa m0 no ma 0u 61 WJ 460 PRODUCT R � WED "SENTINEL" SERIES 130 FIXED WINDOW - LM AGK w a DESIGN LOAD CHARTS OS122/19 .....•.� xana•�.� zoo56soA _ ;` No-Be7As Deft �'f..'.":.":� .Y-�"'^"^'^ ��'.�� IIaO B"MM 6ro B,-. 6w. BI�e PIiEPANEO BY IYNNMLLLFR NO CHANGES THIS SHEET. JR 05/07/20x�ER°L°fi^'E ',FS :f`"Orv�o�.-' G�. PW-730 LM xnc NTS sxr 3 OF 7 D=•Sx xa PW730LMI-NOA w: A AMwoR sP.wxD ro eE As PER sNEErs 1 s z (s4r)4WIeoD ., S/ tiN. q7 �.�AL +,.1 REGSTMTIAN620Aa ALYNN 4NLER.PE. PFJ 56Im m5- D/ 'Kumm MmeNw. Inc.' }/16' PRIL GI.yS 3(Ir NEAT SRtFNb GLA59 V. 1✓E IX2 : CE CORNING D.I 1 CORNNG 791, © 099, 983 OR 995 a ILS AT 1/4 PgN15 ON VIES CIAffi TVDE 'C' )/18' OImN1 VAI. fMA55 3/16- M91. 3/8' AR s a 3/16' RFAT I� 'Nwom/ Mmriw, Mc' SIREN'D GV55 WO• YHelloyer TreallN nterbyr B) 'Kwam/ Nne•ica. Inc 3/16' HEAT SIIER'0 GV55 4 GENAt$ m D 1 E DOW © , I CORNING MNG OR l.995 B9B, 96T OR M5 AT 1/4 IL ON tPEs WIDER THAN 3fi' CLASS TYPE V 7/18' DIpYLL iAm. Gum (L.M.I. ONLY) IN ORDER TO DUAUHY FOR SMALL MISSILE IMPACT RATING EYTERIOR PLY OF GLASS TYPES 'Cl' & 'D1' MUST BE TEMPERED. .07S $nllaa CP tMl PET Cae .075' S00•a CP WRP PET !h 'Eoalmm tlMmirol Co.' InfeHnrer 3/16- I T I3y 'Eoe4mn CPWniwl Co .090• SCOea borC Mtl Lahr Ghee StREN'D GLASS-\ BY k",* r 3/6' Am SPME, Safly Ciem MM Fi B • 'Fnvbmn CMnvml Co. , AnMke, MC '16' MW $IRp1'D GIA4 SLCODE: GE 1200, OOW CORNING 791. 899, 963 OR 995 $$O / LM 16 AT 1/t PONR O11 LIIfS LL4Mee -M TIUN 38' GLASS TYPE 'Cl' 1' OJER1tL LNSOL VM. GLASS • iCR WIUUk m CLASS INSTANA1 A9WE w IN THE IWHL, OR EGR s'AhIY C4LlG MMIGTN1115 P THE F THE ounimao LITE: (GP) mm at Ts,i B . Ivrierim. Mc' I6 HW SIRON-D CLAiS GE 12M GE N OOOW NPIC J a", 999, &T R 985 slu I GE IZO, DOW COm6NG 791, 899, 983 OR 9" •�i1-t1 �ryO / 1 AT 1/M fYlMS ON lRfS WIDER THAN 3r CLASS TYPE bl' r orl3mL NsuL uu clwA TIAe "SENTINEL" SERIES 130 FIXED WINDOW - LM �" AGK Impem ftwm ®WIIMms & DSm, enPaNn= 9Wn tesmlm� GLAZING DETAILS 05/22/19 PRCUYCT EEEMEsm vulMyg OeM�'�FpW �•" r� A' R+. We PREPARED aY LY1dl MR3E RDA.«e. za-osta.o9 MINOR SHEET REFORMATTING. JR 05/0720 101a TELNNaocrwwE lien Pmn $ N. WNICE.FL3 fi ,La. t6 L �� $Opp �•� QO•L'9 N' s"` 19at1 aeuteoo AE.n an P.ea.eFe PW-130 LM NTS 4 OF 7 PW130LMI-NOA A REGmTRATK>N�szea # T �VP I "I',, ONAL E ,'" .YNNMRLER.P.E P.E.t5m05 TYPICAL. INSTALLATION DETAILS THESE DETAILS ARE TYPICAL ON ALL FOUR SIDES OF WINDOW TYPICAL ANCHORS: S ELLV. Tort es w (FLANGE & EQUAL LEG FRAMES) -1/4' DIAL KWIK-CON II BY 'HILT1'(F-10 M. FY 157 KSO 1/4" DIA ULTRACON BY 'ELCO/DEWALY(FaIn M. F1 IM M) INTO 2YY WOOD BUCKS OR WOOD STRUCTURES 1-1/2' MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONCRETE OR BLOCKS / 1-1/4' MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) C 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLACKS 1-1/4' MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) 1-1/4- MIN. EMBED INTO BLOCKS (JAMBS) TYWCeL EDGE DISFs_NCr 94M CONCRETE AND MASONRY — 2 1/2- MIN. INTO WOOD STRUCTURE — I" MIN. A 1 /4' DIA, ULMMCON+ BY 'OEWALY (FwW NSI. Fp10 KSD INTO 20Y WOOD BUCKS OR WOOD STRUCTURES 1-3/8- MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONCRETE OR BLOCKS 1-3/8- MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) 1-1/4- MIN. EMBED IWO HOLLOW BLOCKS (JAMBS) 1-3/4- MIN. EMBED INTO FILLED BLOCKS (JAMBS) C DIRECTLY INTO CONCRETE OR BLOCKS 1-3/8- MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) 1-1/4- MIN. EMBED IWO HOLLOW BLOCKS (JAMBS) 1-3/4' MIN. EMBED INTO FILLED BLOCKS (JAMBS) INTO CONCRETE AND MASONRY - 1 9/16- MIN. INTO WOOD STRUCTURE — 1' MIN. 014 SMS OR W F DRII I ING SCREWS (GRADE 2 CRS) INTO MWA—DARE APPROVED MULLIONS OR INTO META. STRUCTURES (HEAD/SILL/JAMBS) M (3) THREADS MIN. PENETRATION BEYOND SUBTRATE ALUMINUM: 1/8' THK. MIN (8063—M MIN.) STEEL 1/8' THK. MIN. (Fy = 35 KSI MIN.) INSTALLATION DETAILS THRU /K WOOD BUC(S INTO CONCRETE PLANGE 10 INSTALIATNIN DETAILS THRU 2K BUCKS OR IWO WOOD STRUMNES F� 5Ff ELEW. 4BR YIDW MA:K NR SPAG4F EQUAL LE G EQUAL LEG INSTALLATION DETAILS DIRECTLY INTO CONCRETE FLANCT 1/1' M% _.. _ 1/C MAY, 5M13 EQUAL LIE C1 � mill h MSWJATKIN DETAILS INTO METAL STRUCTURES OR INTO APPRP/ED MULLIONS FLANGE WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WOW. MUST SUSTAIN LOADS IMPOSED BY GWJNG SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE I (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED TYPICAL ANCHORS: SEE E1.EV. FOR SPACKIG OR PAINTED) �' "SENTINEL" GTos 4` 0.,.'... FIN FRAI[E SERIES 130 FIXED WINDOW - LM AGK ® y TYPICAL EDGE DISTAL CIF (WOOF 2 INTO METAL STRUCTURE = 3/4' MIN. {1MW 4t INTO 2B TWO 2BY WOOD BUCKS OR WOOD STRUCTURES BUCKS TYPICAL TYPICAL INSTALLATION DETAILS 0522/19 WOOD AT HEAD, SILL OR JAM13S SG = 0.55 MIN 1-1/4' MIN. PENETRATION INTO WOOD 'TJ S IJ (� L %O'. �' Lk AY1. aaR' fltEPpRED OY LYT3N MILLER CONCRETE AT HEAD, SILL OR JAMBS fc = 3000 PSI MIN. TYPI U EDGE DISTANCE C-90 fm REFORMATED & ADDED ANCHOR TYPE JR 0510720 1010T�HNOI°eY DRIVE N.vENIGE. Fl31n4 STALL T '. S ' ';F'.<oRID?.: HOLLOW/FILLED BLOCK AT JAMBS = 2000 PSI MIN, INTO WOOD STRUCTURE = 1' MIN. "�•r s. /(Dee s� see �+a x> rw /TALL mlmo TONAL E.N . nuuP PW-130 LM TUTS 5 OF 7 PW130LMI�lOA A ALYNN MIMER,P£. P.E458TI$ TYPICAL INSTALLATION DETAILS THESE DETAILS ARE TYPICAL ON ALL FOUR SIDES OF WINDOW INSTALLATION Was THRU ix WOOD BUCKS INTO CONCRETE FLANGE ADAPTOR YWII-DICE CWNIY @ MULMIXI MICNgb r INSTAILATON DETAILS THRU U BUCKS OR WO TNOOD SDa1CRME4 FLANGE ADAPTOR MWD SIRUL' NOf 8Y CDI INSTAUXTION DETAILS DIRT Y IMO CONCRETE FLANGE ADAPTOR "sLT""`"`"•Bay. Tn sPAcwc C3 INSTALLATION DETAILS TTRU BN INTO WOOD SIRUCNRES INSTA1IATTON DETAILS INTO METAL. STRUCTURES OR INTO APPROVED MULLIONS lJ EIZCtj 40M9,jL SEEICLL ANgKx6 SEE SP Tow SPACING n 2 31r mic� MEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%*. THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. xoi er cp IAPPRaim EXTERIOR I I Iww-wDE eounr N�BIrvLn II STRUCTURES OR IMD MUuwNs waLloN siI tE I"m ANCTpTs x SEPAMTE NM II L 'I — — — PRODUCT MlVISEo ao�.Txw@.NN u. �KMCaM FLANGE Tmlrx x,cN "GA'"°' zo-os�B-°" SEE EIEV. ..M.. MR spA Bn YiYN `"1,. III I•, �•. ,Mc "SENTINEL" SERIES 130 FIXED WINDOW � AGK Mo: µ: �`•� a.ou PREPARED BY LYNN MI N.vENIGE PLs1ns LBa,Ta86,YW =1v: No. 58705 =.D Q ••T0'. ^ '. FS G��: ,�%S/ONA� E�',•�• nn ul„• pEYNN MRIER, P.E PEf>8T06 PEspWs TYPICAL INSTALLATION DETAILS CONT. oas 05=19 wnYbc REFORMATED B ADDED ANCHOR TYPE bx �: JR Rex WAIF 05/07/20 SnbyM.LN: PHi130 LM sma NTS NwY: 6 OF 7 Lw.rro Ne. PW130LMI-NOA Ra A REGISTRATDNR@B8 2305 L995 Al2 .995 .085 TW. 1.]SS 2565 Al2 4BS 90.5 0455 TYP. 1.J35 816 .9B5 TIP. .975 LIN GLAZING BEAD (LAM. GLAS 120 .895 , 1.1N ttP. GLAZING BEAD (LW. INSUL. C l.t .OftS 1.990 OSo 1395 NAIL FIN ADAPTER 1395y .180 o5R Oe5 FLUSH FRALIE COVER ANGLE (WA. INSUL MASS) I A30 1w 350 A50 E9 FLAME ADAPTOR 1.1 SB1 A50 O SCREW COVER Dfr PA / NBAl9FER O�fIOp Wffe014 Iota./Baen�/2®um El CW-118 4/ WpV. FIANCE FP/JE f�8]-18 E2 CW-119 4/ 11011. PUSH RLWF/FW FNWE WS,I-TB ES 011-121 4/WON. WAIIIG BEb (TAM MA4) WW-TN E4 0W-125 4/ WNW. WAZZEIG HEAD (Vol. MWA. CIAO) W W-T9 - 6 0GI-110 4/ WON. NAI-FN AOWIOR BC6T-TB E8 CW-109 4/ WON. FROM f1AtGE A61PNR 6oW-18 NI CW-]BPV AS REOB. WIAW WUB K(M1 PVC YB Icll!R 75- 91tl1E A Q M-124 AS REW. SCREW COVER- OFDONIL P1C NS CGI-112 AS REW. FLUSH FRAME OO PW: W OPRIXYL WA2NC .WGIE (1 2 1/2 R t/8) eoWYlS YS 2/ VIE SITTING BLOCI6 I EPW OniONflER B.StS SROIIE A S2 /lo W 1-1/4' 2/ tlIRIFR L&SSOMY SWILW I L. PH SQI I ST/ST CIRCULAR WINDOWS T RECT. OR SQUARE WINDOWS TYP CORNER DSTAD_S Ipc Ywe BA "SENTINEL" SERIES 130 FIXED WINDOW - LM AGK le I. wI Resisw WRR9Ws 8 own PRODUCT REVLSED I EXTRUSIONS, BOM 0522/19 ��I".HA a"P1wu. 9egbe Fµ 0: FWA oaee noAal.. 2oas9so9 I NO CHANGES THIS SHEET. I JR 1 05/0720 iOPsr LYcj M A.: No. Sb7O5 1F =v r:9 w.Pl.eP A I WIWI A INRE4'/l'TlOrnNnALP-13I NT17 —Si�lEl r.�. ALYNN LOITER PE PEW5Np5