Loading...
HomeMy WebLinkAboutSCHWARTZ RES.-ENERGY CALCFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SCHWARTZ RENO Builder Name: Street:2601 NW JUNIPER COURT Permit Office: ST. LUCIE COUNTY City, State, Zip: PALM CITY, FL, Permit Number: Owner:Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case?No 6. Conditioned floor area above grade (ft²)3733 Conditioned floor area below grade (ft²)0 7. Windows(610.0 sqft.) Description Area a. U-Factor:Sgl, U=0.29 412.00 ft2 S H G C :SHGC=0.21 b. U-Factor:Sgl, U=0.35 188.00 ft2 S H G C :SHGC=0.20 c. U-Factor:Sgl, U=0.31 10.00 ft2 S H G C :SHGC=0.18 Area Weighted Average Overhang Depth: 7.003 ft Area Weighted Average SHGC:0.206 8. Skylights Description Area U - F a c t o r : ( A V G ) N/A N/A ft2 S H G C ( A V G ) : N/A 9. Floor Types I n s u l a t i o n Area a. Slab-On-Grade Edge Insulation R= 0.0 3730.10 f t 2 b. N/A R = f t2 c. N/A R = f t2 10. Wall Types(3890.0 sqft.) I n s u l a t i o n Area a. Concrete Block - Int Insul, ExteriorR=4.1 3614.00 ft 2 b. Frame - Wood, Adjacent R=11.0 276.00 ft 2 c. N/A R = f t2 d. N/A R= f t2 11. Ceiling Types(3733.0 sqft.) I n s u l a t i o n Area a. Under Attic (Vented)R=30.0 3733.00 ft 2 b. N/A R= f t 2 c. N/A R= f t 2 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 325 b. b. Sup: Attic, Ret: Attic, AH: Attic 6 150 c . 13. Cooling Systems k B t u / h r Efficiency a. Central Unit 58.0 SEER:16.00 b. Central Unit 24.0 SEER:16.00 14. Heating Systems k B t u / h r Efficiency a. Electric Strip Heat 34.0 COP:1.00 b. Electric Strip Heat 17.0 COP:1.00 15. Hot Water Systems a. Electric Cap: 50 gallons EF: 0.950 b. Conservation features None 16. Credits None Glass/Floor Area:0.163 Total Proposed Modified Loads: 106.22 Total Baseline Loads: 114.94 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code.calculation indicates compliance with the Florida Energy Code. PREPARED BY: _________________________________ Before construction is completed this building will be inspected for DATE: _________________________________________ compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: __________________________________ BUILDING OFFICIAL: ____________________________ DATE: _________________________________________ DATE: _________________________________________ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 3/1/2022 1:44:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 3-1-2022 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title:SCHWARTZ RENO Address type:Street Address Building Type:Bedrooms:Lot #:User 3 --- Owner:Conditioned Area:Block/SubDivision:3733 --- Total Stories:PlatBook:1 --- Builder Name:Worst Case:Street:No 2601 NW JUNIPER COURT Permit Office:Rotate Angle:County:ST. LUCIE COUNTY 0 St. Lucie Jurisdiction:Cross Ventilation:City, State, Zip:No PALM CITY, Family Type:Whole House Fan: Detached No F L , New/Existing:Terrain: New (From Plans)Suburban Year Construct:Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range ___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume ___ 1 UNIT #2 1349 16188 ___ 2 UNIT #1 2384 28608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated ___ 1 FAMILY ROOM 320 3840 No 4 Yes Yes Yes ___ 2 BEDROOM 2 307 3684 No 1 1 Yes Yes Yes ___ 3 BATH 2 135 1620 No 0 Yes Yes Yes ___ 4 BEDROOM 3 208 2496 No 1 1 Yes Yes Yes ___ 5 BREAKFAST 221 2652 No 0 Yes Yes Yes ___ 6 KITCHEN 238 2856 Yes 0 No Yes Yes ___ 7 PANTRY 42 504 No 0 No Yes Yes ___ 8 LIVING ROOM 529 6348 No 0 Yes Yes Yes ___ 9 HALL 146 1752 No 0 No Yes Yes ___ 10 POWDER 42 504 No 0 No Yes Yes ___ 11 LAUNDRY 128 1536 No 0 Yes Yes Yes ___ 12 CLST.68 816 No 0 Yes Yes Yes ___ 13 FOYER 190 2280 No 0 Yes Yes Yes ___ 14 DINING 148 1776 No 0 Yes Yes Yes ___ 15 WIC 141 1692 No 0 Yes Yes Yes ___ 16 M BATH 192 2304 No 0 Yes Yes Yes ___ 17 MAST ERBEDROOM 479 5748 No 2 1 Yes Yes Yes ___ 18 LIBRARY 199 2388 No 0 Yes Yes Yes 3/1/2022 1:44:18 PM Page 2EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS (Total Exposed Area = 3730 sq.ft.) #Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet ___ 1 Slab-On-Grade Edge Ins FAMILY ROOM 25 0 320 ft 0.473 ---0.00 1.00 0.00 ___ 2 Slab-On-Grade Edge Ins BEDROOM 2 38.8 0 306.5 ft 0.473 ---0.00 1.00 0.00 ___ 3 Slab-On-Grade Edge Ins BATH 2 11 0 135 ft 0.473 ---0.00 1.00 0.00 ___ 4 Slab-On-Grade Edge Ins BEDROOM 3 20 0 208 ft 0.473 ---0.00 1.00 0.00 ___ 5 Slab-On-Grade Edge Ins BREAKFAST 17 0 220.5 ft 0.473 ---0.00 1.00 0.00 ___ 6 Slab-On-Grade Edge Ins KITCHEN 1 0 238 ft 0.473 ---0.00 1.00 0.00 ___ 7 Slab-On-Grade Edge Ins PANTRY 1 0 42 ft 0.473 ---0.00 1.00 0.00 ___ 8 Slab-On-Grade Edge Ins LIVING ROOM 19.8 0 529 ft 0.473 ---0.00 1.00 0.00 ___ 9 Slab-On-Grade Edge Ins HALL 1 0 146 ft 0.473 ---0.00 1.00 0.00 ___ 10 Slab-On-Grade Edge Ins POWDER 1 0 42 ft 0.473 ---0.00 1.00 0.00 ___ 11 Slab-On-Grade Edge Ins LAUNDRY 19 0 127.5 ft 0.473 ---0.00 1.00 0.00 ___ 12 Slab-On-Grade Edge Ins CLST.7.8 0 68 ft 0.473 ---0.00 1.00 0.00 ___ 13 Slab-On-Grade Edge Ins FOYER 5.3 0 190 ft 0.473 ---0.00 1.00 0.00 ___ 14 Slab-On-Grade Edge Ins DINING 20.5 0 147.6 ft 0.473 ---0.00 1.00 0.00 ___ 15 Slab-On-Grade Edge Ins WIC 9.9 0 140.5 ft 0.473 ---0.00 1.00 0.00 ___ 16 Slab-On-Grade Edge Ins M BATH 44 0 192 ft 0.473 ---0.00 1.00 0.00 ___ 17 Slab-On-Grade Edge Ins MAST ERBEDROOM 51.7 0 479 ft 0.473 ---0.00 1.00 0.00 ___ 18 Slab-On-Grade Edge Ins LIBRARY 34 0 198.5 ft 0.473 ---0.00 1.00 0.00 ROOF Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch #Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg) ___ 1 Hip Barrel tile 4170 ft²0 ft²Medium N 0.6 No 0.6 No 0 26.57 ATTIC #Type Ventilation Vent Ratio (1 in)Area RBS IRCC ___ 1 Full attic Vented 150 3730 ft²N N CEILING (Total Exposed Area = 3733 sq.ft.) #Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type ___ 1 Under Attic(Vented)FAMILY ROOM 30.0 Blown 320.0ft²0.053 0.10 Wood ___ 2 Under Attic(Vented)BEDROOM 2 30.0 Blown 307.0ft²0.053 0.10 Wood ___ 3 Under Attic(Vented)BATH 2 30.0 Blown 135.0ft²0.053 0.10 Wood ___ 4 Under Attic(Vented)BEDROOM 3 30.0 Blown 208.0ft²0.053 0.10 Wood ___ 5 Under Attic(Vented)BREAKFAST 30.0 Blown 221.0ft²0.053 0.10 Wood ___ 6 Under Attic(Vented)KITCHEN 30.0 Blown 238.0ft²0.053 0.10 Wood ___ 7 Under Attic(Vented)PANTRY 30.0 Blown 42.0ft²0.053 0.10 Wood ___ 8 Under Attic(Vented)LIVING ROOM 30.0 Blown 529.0ft²0.053 0.10 Wood ___ 9 Under Attic(Vented)HALL 30.0 Blown 146.0ft²0.053 0.10 Wood ___ 10 Under Attic(Vented)POWDER 30.0 Blown 42.0ft²0.053 0.10 Wood ___ 11 Under Attic(Vented)LAUNDRY 30.0 Blown 128.0ft²0.053 0.10 Wood ___ 12 Under Attic(Vented)CLST.30.0 Blown 68.0ft²0.053 0.10 Wood ___ 13 Under Attic(Vented)FOYER 30.0 Blown 190.0ft²0.053 0.10 Wood ___ 14 Under Attic(Vented)DINING 30.0 Blown 148.0ft²0.053 0.10 Wood ___ 15 Under Attic(Vented)WIC 30.0 Blown 141.0ft²0.053 0.10 Wood ___ 16 Under Attic(Vented)M BATH 30.0 Blown 192.0ft²0.053 0.10 Wood ___ 17 Under Attic(Vented)MAST ERBEDROOM 30.0 Blown 479.0ft²0.053 0.10 Wood ___ 18 Under Attic(Vented)LIBRARY 30.0 Blown 199.0ft²0.053 0.10 Wood 3/1/2022 1:44:18 PM Page 3EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS (Total Exposed Area = 3890 sq.ft.) Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below #Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade ___ 1 NE Exterior Conc. Blk - Int Ins FAMILY ROOM 4.1 2.0 0 12.0 0 24.0 0.149 0 0 0.50 0 % ___ 2 SW Exterior Conc. Blk - Int Ins FAMILY ROOM 4.1 7.0 0 12.0 0 84.0 0.149 0 0 0.50 0 % ___ 3 NW Exterior Conc. Blk - Int Ins FAMILY ROOM 4.1 16.0 0 12.0 0 192.0 0.149 0 0 0.50 0 % ___ 4 NE Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 19.0 0 12.0 0 228.0 0.149 0 0 0.50 0 % ___ 5 W Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 9.0 11 12.0 0 119.0 0.149 0 0 0.50 0 % ___ 6 NW Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 10.0 0 12.0 0 120.0 0.149 0 0 0.50 0 % ___ 7 NE Exterior Conc. Blk - Int Ins BATH 2 4.1 11.0 0 12.0 0 132.0 0.149 0 0 0.50 0 % ___ 8 NW Exterior Conc. Blk - Int Ins BEDROOM 3 4.1 7.0 0 12.0 0 84.0 0.149 0 0 0.50 0 % ___ 9 W Exterior Conc. Blk - Int Ins BREAKFAST 4.1 17.0 0 12.0 0 204.0 0.149 0 0 0.50 0 % ___ 10 W Exterior Conc. Blk - Int Ins LIVING ROOM 4.1 19.0 10 12.0 0 238.0 0.149 0 0 0.50 0 % ___ 11 SE Exterior Conc. Blk - Int Ins LAUNDRY 4.1 9.0 0 12.0 0 108.0 0.149 0 0 0.50 0 % ___ 12 S Exterior Conc. Blk - Int Ins CLST.4.1 7.0 10 12.0 0 94.0 0.149 0 0 0.50 0 % ___ 13 NE Exterior Conc. Blk - Int Ins FOYER 4.1 1.0 2 12.0 0 14.0 0.149 0 0 0.50 0 % ___ 14 E Exterior Conc. Blk - Int Ins FOYER 4.1 4.0 3 12.0 0 51.0 0.149 0 0 0.50 0 % ___ 15 NE Exterior Conc. Blk - Int Ins DINING 4.1 5.0 0 12.0 0 60.0 0.149 0 0 0.50 0 % ___ 16 E Exterior Conc. Blk - Int Ins DINING 4.1 5.0 8 12.0 0 68.0 0.149 0 0 0.50 0 % ___ 17 SE Exterior Conc. Blk - Int Ins DINING 4.1 6.0 0 12.0 0 72.0 0.149 0 0 0.50 0 % ___ 18 S Exterior Conc. Blk - Int Ins DINING 4.1 3.0 10 12.0 0 46.0 0.149 0 0 0.50 0 % ___ 19 NE Exterior Conc. Blk - Int Ins WIC 4.1 10.0 0 12.0 0 120.0 0.149 0 0 0.50 0 % ___ 20 NE Exterior Conc. Blk - Int Ins M BATH 4.1 14.0 0 12.0 0 168.0 0.149 0 0 0.50 0 % ___ 21 SE Exterior Conc. Blk - Int Ins M BATH 4.1 16.0 0 12.0 0 192.0 0.149 0 0 0.50 0 % ___ 22 SW Exterior Conc. Blk - Int Ins M BATH 4.1 14.0 0 12.0 0 168.0 0.149 0 0 0.50 0 % ___ 23 N Exterior Conc. Blk - Int Ins MAST ERBEDROOM 4.1 7.0 10 12.0 0 94.0 0.149 0 0 0.50 0 % ___ 24 SE Exterior Conc. Blk - Int Ins MAST ERBEDROOM 4.1 24.0 3 12.0 0 291.0 0.149 0 0 0.50 0 % ___ 25 S Exterior Conc. Blk - Int Ins MAST ERBEDROOM 4.1 3.0 7 12.0 0 43.0 0.149 0 0 0.50 0 % ___ 26 SW Exterior Conc. Blk - Int Ins MAST ERBEDROOM 4.1 16.0 0 12.0 0 192.0 0.149 0 0 0.50 0 % ___ 27 SE Exterior Conc. Blk - Int Ins LIBRARY 4.1 10.0 0 12.0 0 120.0 0.149 0 0 0.50 0 % ___ 28 SW Exterior Conc. Blk - Int Ins LIBRARY 4.1 15.0 0 12.0 0 180.0 0.149 0 0 0.50 0 % ___ 29 NW Exterior Conc. Blk - Int Ins LIBRARY 4.1 9.0 0 12.0 0 108.0 0.149 0 0 0.50 0 % ___ 30 SW Garage Frame - Wood FAMILY ROOM 11.0 23.0 0 12.0 0 276.0 0.092 0.23 0.50 0 % DOORS (Total Exposed Area = 30 sq.ft.) Width Height #Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area ___ 1 E Insulated FOYER None 0.39 4.00 3 7.00 0 29.8ft² WINDOWS (Total Exposed Area = 610 sq.ft.) Wall -----Overhang----- #Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening ___ 1 NW 3 Vinyl Low-E Single Yes 0.31 0.18 Y N 4.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 2 NW 3 Vinyl Low-E Single Yes 0.31 0.18 Y N 6.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 3 NW 3 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 4 NE 4 Vinyl Low-E Single Yes 0.29 0.21 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 5 W 5 Vinyl Low-E Single Yes 0.29 0.21 Y N 29.5ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 6 NW 6 Vinyl Low-E Single Yes 0.29 0.21 Y N 29.5ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 7 NE 7 Vinyl Low-E Single Yes 0.29 0.21 Y N 12.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 8 NW 8 Vinyl Low-E Single Yes 0.29 0.21 Y N 29.5ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 9 W 9 Vinyl Low-E Single Yes 0.35 0.20 Y N 94.0ft²16.0 ft 0 in 1.0 ft 4 in None None ___ 10 W 10 Vinyl Low-E Single Yes 0.35 0.20 Y N 94.0ft²16.0 ft 0 in 1.0 ft 4 in None None ___ 11 SE 11 Vinyl Low-E Single Yes 0.29 0.21 Y N 29.5ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 12 NE 15 Vinyl Low-E Single Yes 0.29 0.21 Y N 20.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 13 E 16 Vinyl Low-E Single Yes 0.29 0.21 Y N 20.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 14 SE 17 Vinyl Low-E Single Yes 0.29 0.21 Y N 20.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 15 SE 21 Vinyl Low-E Single Yes 0.29 0.21 Y N 12.5ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 16 SE 24 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²2.0 ft 0 in 1.0 ft 4 in None None 3/1/2022 1:44:18 PM Page 4EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS(Continued) ___ 17 SE 24 Vinyl Low-E Single Yes 0.29 0.21 Y N 23.5ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 18 SW 26 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 19 SW 26 Vinyl Low-E Single Yes 0.29 0.21 Y N 21.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 20 SW 28 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 21 NW 29 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²16.0 ft 0 in 1.0 ft 4 in None None INFILTRATION #Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s) ___ 1 Wholehouse Proposed ACH(50)0.00038 3733 204.80 384.50 0.1061 5.0 All GARAGE #Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ___ 1 504 ft²504 ft²64 ft 8 ft 1 MASS #Mass Type Area Thickness Furniture Fraction Space ___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 FAMILY ROOM ___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 2 ___ 3 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BATH 2 ___ 4 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 3 ___ 5 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BREAKFAST ___ 6 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 KITCHEN ___ 7 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 PANTRY ___ 8 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 LIVING ROOM ___ 9 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 HALL ___ 10 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 POWDER ___ 11 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 LAUNDRY ___ 12 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 CLST. ___ 13 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 FOYER ___ 14 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 DINING ___ 15 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 WIC ___ 16 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 M BATH ___ 17 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 MAST ERBEDROOM ___ 18 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 LIBRARY HEATING SYSTEM #System Type Subtype AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block kBtu/hr Entry Power Volt Current ___ 1 Electric Strip Heat None COP: 1.00 34.0 0.00 0.00 0.00 sys#1 2 ___ 2 Electric Strip Heat None COP: 1.00 17.0 0.00 0.00 0.00 sys#2 1 COOLING SYSTEM #System Type Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm ___ 1 Central Unit Split/Single SEER:16.0 58.0 0 0.70 sys#1 2 ___ 2 Central Unit Split/Single SEER:16.0 24.0 0 0.70 sys#2 1 3/1/2022 1:44:18 PM Page 5EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM #System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length ___ 1 Electric None LAUNDRY 0.95 (0.93)50.00 gal 61 gal 120 deg Standard None 132 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff ___ 1 No NA NA NA No NA NA NA None DUCTS Duct ---------Supply------------------Return---------Air CFM 25 CFM 25 HVAC # #Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool ___ 1 Attic 6.0 325 ft²Attic 6.0 65 ft²Default Leakage Attic (Default)(Default)1 1 ___ 2 Attic 6.0 150 ft²Attic 6.0 65 ft²Default Leakage Attic (Default)(Default)2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 ___ Cooling (WD)AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 ___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 ___ Heating (WD)AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 ___ Heating (WEH)AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/1/2022 1:44:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 CHECK2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name:SCHWARTZ RENO Builder Name: Street:2601 NW JUNIPER COURT Permit Office:ST. LUCIE COUNTY City, State, Zip:PALM CITY, FL, Permit Number: Owner:Jurisdiction: Design Location:FL, Fort Pierce County:St. Lucie(Florida Climate Zone 2) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope.Air-permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier.not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed.shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed.Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed.a material having a thermal resistance of R-3 per Knee walls shall be sealed.inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier.Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation.maintain permanent contact with the underside of above-garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors)of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped.shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface.thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs.be insulated. Electrical/phone box The air barrier shall be installed behind electrical or on exterior walls communication boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 3/1/2022 1:44:18 PM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index, the more efficient the home. 2601 NW JUNIPER COURT,PALM CITY,FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case?No 6. Conditioned floor area above grade (ft²)3733 Conditioned floor area below grade (ft²)0 7. Windows**Description Area a. U-Factor:Sgl, U=0.29 412.00 ft2 S H G C :SHGC=0.21 b. U-Factor:Sgl, U=0.35 188.00 ft2 S H G C :SHGC=0.20 c. U-Factor:Sgl, U=0.31 10.00 ft2 S H G C :SHGC=0.18 Area Weighted Average Overhang Depth:7.003 ft Area Weighted Average SHGC:0.206 8. Skylights Description Area U - F a c t o r : ( A V G )N/A N/A ft2 S H G C ( A V G ) :N/A 9. Floor Types I n s u l a t i o n Area a. Slab-On-Grade Edge Insulation R= 0.0 3730.10 f t2 b. N/A R = f t2 c. N/A R = f t2 10. Wall Types(3890.0 sqft.) I n s u l a t i o n Area a. Concrete Block - Int Insul, ExteriorR=4.1 3614.00 ft2 b. Frame - Wood, Adjacent R=11.0 276.00 ft2 c. N/A R = f t2 d. N/A R= f t2 11. Ceiling Types(3733.0 sqft.) I n s u l a t i o n Area a. Under Attic (Vented)R=30.0 3733.00 ft2 b. N/A R= f t2 c. N/A R= f t2 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 325 b. b. Sup: Attic, Ret: Attic, AH: Attic 6 150 c . 13. Cooling Systems k B t u / h r Efficiency a. Central Unit 58.0 SEER:16.00 b. Central Unit 24.0 SEER:16.00 14. Heating Systems k B t u / h r Efficiency a. Electric Strip Heat 34.0 COP:1.00 b. Electric Strip Heat 17.0 COP:1.00 15. Hot Water Systems a. Electric Cap: 50 gallons EF: 0.950 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: ___________________________________Date: _________________________ Address of New Home: 2601 NW JUNIPER COURT City/FL Zip: PALM CITY,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/1/2022 1:44:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1