HomeMy WebLinkAboutSCHWARTZ RES.-ENERGY CALCFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SCHWARTZ RENO Builder Name:
Street:2601 NW JUNIPER COURT Permit Office: ST. LUCIE COUNTY
City, State, Zip: PALM CITY, FL, Permit Number:
Owner:Jurisdiction:
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
2. Single family or multiple family Detached
3. Number of units, if multiple family 1
4. Number of Bedrooms 3
5. Is this a worst case?No
6. Conditioned floor area above grade (ft²)3733
Conditioned floor area below grade (ft²)0
7. Windows(610.0 sqft.) Description Area
a. U-Factor:Sgl, U=0.29 412.00 ft2
S H G C :SHGC=0.21
b. U-Factor:Sgl, U=0.35 188.00 ft2
S H G C :SHGC=0.20
c. U-Factor:Sgl, U=0.31 10.00 ft2
S H G C :SHGC=0.18
Area Weighted Average Overhang Depth: 7.003 ft
Area Weighted Average SHGC:0.206
8. Skylights Description Area
U - F a c t o r : ( A V G ) N/A N/A ft2
S H G C ( A V G ) : N/A
9. Floor Types I n s u l a t i o n Area
a. Slab-On-Grade Edge Insulation R= 0.0 3730.10 f t
2
b. N/A R = f t2
c. N/A R = f t2
10. Wall Types(3890.0 sqft.) I n s u l a t i o n Area
a. Concrete Block - Int Insul, ExteriorR=4.1 3614.00 ft
2
b. Frame - Wood, Adjacent R=11.0 276.00 ft
2
c. N/A R = f t2
d. N/A R= f t2
11. Ceiling Types(3733.0 sqft.) I n s u l a t i o n Area
a. Under Attic (Vented)R=30.0 3733.00 ft
2
b. N/A R= f t
2
c. N/A R= f t
2
12. Ducts, location & insulation level R ft2
a. a. Sup: Attic, Ret: Attic, AH: Attic 6 325
b. b. Sup: Attic, Ret: Attic, AH: Attic 6 150
c .
13. Cooling Systems k B t u / h r Efficiency
a. Central Unit 58.0 SEER:16.00
b. Central Unit 24.0 SEER:16.00
14. Heating Systems k B t u / h r Efficiency
a. Electric Strip Heat 34.0 COP:1.00
b. Electric Strip Heat 17.0 COP:1.00
15. Hot Water Systems
a. Electric Cap: 50 gallons
EF: 0.950
b. Conservation features
None
16. Credits None
Glass/Floor Area:0.163 Total Proposed Modified Loads: 106.22
Total Baseline Loads: 114.94 PASS
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code.calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: _________________________________ Before construction is completed
this building will be inspected for
DATE: _________________________________________ compliance with Section 553.908
Florida Statutes.
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT: __________________________________ BUILDING OFFICIAL: ____________________________
DATE: _________________________________________ DATE: _________________________________________
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
3/1/2022 1:44:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
3-1-2022
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:SCHWARTZ RENO Address type:Street Address
Building Type:Bedrooms:Lot #:User 3 ---
Owner:Conditioned Area:Block/SubDivision:3733 ---
Total Stories:PlatBook:1 ---
Builder Name:Worst Case:Street:No 2601 NW JUNIPER COURT
Permit Office:Rotate Angle:County:ST. LUCIE COUNTY 0 St. Lucie
Jurisdiction:Cross Ventilation:City, State, Zip:No PALM CITY,
Family Type:Whole House Fan: Detached No F L ,
New/Existing:Terrain: New (From Plans)Suburban
Year Construct:Shielding: Suburban
Comment:
CLIMATE
Design Design Temp Int Design Temp Heating Design Daily temp
Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range
___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
___ 1 UNIT #2 1349 16188
___ 2 UNIT #1 2384 28608
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
___ 1 FAMILY ROOM 320 3840 No 4 Yes Yes Yes
___ 2 BEDROOM 2 307 3684 No 1 1 Yes Yes Yes
___ 3 BATH 2 135 1620 No 0 Yes Yes Yes
___ 4 BEDROOM 3 208 2496 No 1 1 Yes Yes Yes
___ 5 BREAKFAST 221 2652 No 0 Yes Yes Yes
___ 6 KITCHEN 238 2856 Yes 0 No Yes Yes
___ 7 PANTRY 42 504 No 0 No Yes Yes
___ 8 LIVING ROOM 529 6348 No 0 Yes Yes Yes
___ 9 HALL 146 1752 No 0 No Yes Yes
___ 10 POWDER 42 504 No 0 No Yes Yes
___ 11 LAUNDRY 128 1536 No 0 Yes Yes Yes
___ 12 CLST.68 816 No 0 Yes Yes Yes
___ 13 FOYER 190 2280 No 0 Yes Yes Yes
___ 14 DINING 148 1776 No 0 Yes Yes Yes
___ 15 WIC 141 1692 No 0 Yes Yes Yes
___ 16 M BATH 192 2304 No 0 Yes Yes Yes
___ 17 MAST ERBEDROOM 479 5748 No 2 1 Yes Yes Yes
___ 18 LIBRARY 199 2388 No 0 Yes Yes Yes
3/1/2022 1:44:18 PM Page 2EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS (Total Exposed Area = 3730 sq.ft.)
#Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet
___ 1 Slab-On-Grade Edge Ins FAMILY ROOM 25 0 320 ft 0.473 ---0.00 1.00 0.00
___ 2 Slab-On-Grade Edge Ins BEDROOM 2 38.8 0 306.5 ft 0.473 ---0.00 1.00 0.00
___ 3 Slab-On-Grade Edge Ins BATH 2 11 0 135 ft 0.473 ---0.00 1.00 0.00
___ 4 Slab-On-Grade Edge Ins BEDROOM 3 20 0 208 ft 0.473 ---0.00 1.00 0.00
___ 5 Slab-On-Grade Edge Ins BREAKFAST 17 0 220.5 ft 0.473 ---0.00 1.00 0.00
___ 6 Slab-On-Grade Edge Ins KITCHEN 1 0 238 ft 0.473 ---0.00 1.00 0.00
___ 7 Slab-On-Grade Edge Ins PANTRY 1 0 42 ft 0.473 ---0.00 1.00 0.00
___ 8 Slab-On-Grade Edge Ins LIVING ROOM 19.8 0 529 ft 0.473 ---0.00 1.00 0.00
___ 9 Slab-On-Grade Edge Ins HALL 1 0 146 ft 0.473 ---0.00 1.00 0.00
___ 10 Slab-On-Grade Edge Ins POWDER 1 0 42 ft 0.473 ---0.00 1.00 0.00
___ 11 Slab-On-Grade Edge Ins LAUNDRY 19 0 127.5 ft 0.473 ---0.00 1.00 0.00
___ 12 Slab-On-Grade Edge Ins CLST.7.8 0 68 ft 0.473 ---0.00 1.00 0.00
___ 13 Slab-On-Grade Edge Ins FOYER 5.3 0 190 ft 0.473 ---0.00 1.00 0.00
___ 14 Slab-On-Grade Edge Ins DINING 20.5 0 147.6 ft 0.473 ---0.00 1.00 0.00
___ 15 Slab-On-Grade Edge Ins WIC 9.9 0 140.5 ft 0.473 ---0.00 1.00 0.00
___ 16 Slab-On-Grade Edge Ins M BATH 44 0 192 ft 0.473 ---0.00 1.00 0.00
___ 17 Slab-On-Grade Edge Ins MAST ERBEDROOM 51.7 0 479 ft 0.473 ---0.00 1.00 0.00
___ 18 Slab-On-Grade Edge Ins LIBRARY 34 0 198.5 ft 0.473 ---0.00 1.00 0.00
ROOF
Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch
#Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg)
___ 1 Hip Barrel tile 4170 ft²0 ft²Medium N 0.6 No 0.6 No 0 26.57
ATTIC
#Type Ventilation Vent Ratio (1 in)Area RBS IRCC
___ 1 Full attic Vented 150 3730 ft²N N
CEILING (Total Exposed Area = 3733 sq.ft.)
#Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type
___ 1 Under Attic(Vented)FAMILY ROOM 30.0 Blown 320.0ft²0.053 0.10 Wood
___ 2 Under Attic(Vented)BEDROOM 2 30.0 Blown 307.0ft²0.053 0.10 Wood
___ 3 Under Attic(Vented)BATH 2 30.0 Blown 135.0ft²0.053 0.10 Wood
___ 4 Under Attic(Vented)BEDROOM 3 30.0 Blown 208.0ft²0.053 0.10 Wood
___ 5 Under Attic(Vented)BREAKFAST 30.0 Blown 221.0ft²0.053 0.10 Wood
___ 6 Under Attic(Vented)KITCHEN 30.0 Blown 238.0ft²0.053 0.10 Wood
___ 7 Under Attic(Vented)PANTRY 30.0 Blown 42.0ft²0.053 0.10 Wood
___ 8 Under Attic(Vented)LIVING ROOM 30.0 Blown 529.0ft²0.053 0.10 Wood
___ 9 Under Attic(Vented)HALL 30.0 Blown 146.0ft²0.053 0.10 Wood
___ 10 Under Attic(Vented)POWDER 30.0 Blown 42.0ft²0.053 0.10 Wood
___ 11 Under Attic(Vented)LAUNDRY 30.0 Blown 128.0ft²0.053 0.10 Wood
___ 12 Under Attic(Vented)CLST.30.0 Blown 68.0ft²0.053 0.10 Wood
___ 13 Under Attic(Vented)FOYER 30.0 Blown 190.0ft²0.053 0.10 Wood
___ 14 Under Attic(Vented)DINING 30.0 Blown 148.0ft²0.053 0.10 Wood
___ 15 Under Attic(Vented)WIC 30.0 Blown 141.0ft²0.053 0.10 Wood
___ 16 Under Attic(Vented)M BATH 30.0 Blown 192.0ft²0.053 0.10 Wood
___ 17 Under Attic(Vented)MAST ERBEDROOM 30.0 Blown 479.0ft²0.053 0.10 Wood
___ 18 Under Attic(Vented)LIBRARY 30.0 Blown 199.0ft²0.053 0.10 Wood
3/1/2022 1:44:18 PM Page 3EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS (Total Exposed Area = 3890 sq.ft.)
Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below
#Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade
___ 1 NE Exterior Conc. Blk - Int Ins FAMILY ROOM 4.1 2.0 0 12.0 0 24.0 0.149 0 0 0.50 0 %
___ 2 SW Exterior Conc. Blk - Int Ins FAMILY ROOM 4.1 7.0 0 12.0 0 84.0 0.149 0 0 0.50 0 %
___ 3 NW Exterior Conc. Blk - Int Ins FAMILY ROOM 4.1 16.0 0 12.0 0 192.0 0.149 0 0 0.50 0 %
___ 4 NE Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 19.0 0 12.0 0 228.0 0.149 0 0 0.50 0 %
___ 5 W Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 9.0 11 12.0 0 119.0 0.149 0 0 0.50 0 %
___ 6 NW Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 10.0 0 12.0 0 120.0 0.149 0 0 0.50 0 %
___ 7 NE Exterior Conc. Blk - Int Ins BATH 2 4.1 11.0 0 12.0 0 132.0 0.149 0 0 0.50 0 %
___ 8 NW Exterior Conc. Blk - Int Ins BEDROOM 3 4.1 7.0 0 12.0 0 84.0 0.149 0 0 0.50 0 %
___ 9 W Exterior Conc. Blk - Int Ins BREAKFAST 4.1 17.0 0 12.0 0 204.0 0.149 0 0 0.50 0 %
___ 10 W Exterior Conc. Blk - Int Ins LIVING ROOM 4.1 19.0 10 12.0 0 238.0 0.149 0 0 0.50 0 %
___ 11 SE Exterior Conc. Blk - Int Ins LAUNDRY 4.1 9.0 0 12.0 0 108.0 0.149 0 0 0.50 0 %
___ 12 S Exterior Conc. Blk - Int Ins CLST.4.1 7.0 10 12.0 0 94.0 0.149 0 0 0.50 0 %
___ 13 NE Exterior Conc. Blk - Int Ins FOYER 4.1 1.0 2 12.0 0 14.0 0.149 0 0 0.50 0 %
___ 14 E Exterior Conc. Blk - Int Ins FOYER 4.1 4.0 3 12.0 0 51.0 0.149 0 0 0.50 0 %
___ 15 NE Exterior Conc. Blk - Int Ins DINING 4.1 5.0 0 12.0 0 60.0 0.149 0 0 0.50 0 %
___ 16 E Exterior Conc. Blk - Int Ins DINING 4.1 5.0 8 12.0 0 68.0 0.149 0 0 0.50 0 %
___ 17 SE Exterior Conc. Blk - Int Ins DINING 4.1 6.0 0 12.0 0 72.0 0.149 0 0 0.50 0 %
___ 18 S Exterior Conc. Blk - Int Ins DINING 4.1 3.0 10 12.0 0 46.0 0.149 0 0 0.50 0 %
___ 19 NE Exterior Conc. Blk - Int Ins WIC 4.1 10.0 0 12.0 0 120.0 0.149 0 0 0.50 0 %
___ 20 NE Exterior Conc. Blk - Int Ins M BATH 4.1 14.0 0 12.0 0 168.0 0.149 0 0 0.50 0 %
___ 21 SE Exterior Conc. Blk - Int Ins M BATH 4.1 16.0 0 12.0 0 192.0 0.149 0 0 0.50 0 %
___ 22 SW Exterior Conc. Blk - Int Ins M BATH 4.1 14.0 0 12.0 0 168.0 0.149 0 0 0.50 0 %
___ 23 N Exterior Conc. Blk - Int Ins MAST ERBEDROOM 4.1 7.0 10 12.0 0 94.0 0.149 0 0 0.50 0 %
___ 24 SE Exterior Conc. Blk - Int Ins MAST ERBEDROOM 4.1 24.0 3 12.0 0 291.0 0.149 0 0 0.50 0 %
___ 25 S Exterior Conc. Blk - Int Ins MAST ERBEDROOM 4.1 3.0 7 12.0 0 43.0 0.149 0 0 0.50 0 %
___ 26 SW Exterior Conc. Blk - Int Ins MAST ERBEDROOM 4.1 16.0 0 12.0 0 192.0 0.149 0 0 0.50 0 %
___ 27 SE Exterior Conc. Blk - Int Ins LIBRARY 4.1 10.0 0 12.0 0 120.0 0.149 0 0 0.50 0 %
___ 28 SW Exterior Conc. Blk - Int Ins LIBRARY 4.1 15.0 0 12.0 0 180.0 0.149 0 0 0.50 0 %
___ 29 NW Exterior Conc. Blk - Int Ins LIBRARY 4.1 9.0 0 12.0 0 108.0 0.149 0 0 0.50 0 %
___ 30 SW Garage Frame - Wood FAMILY ROOM 11.0 23.0 0 12.0 0 276.0 0.092 0.23 0.50 0 %
DOORS (Total Exposed Area = 30 sq.ft.)
Width Height
#Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area
___ 1 E Insulated FOYER None 0.39 4.00 3 7.00 0 29.8ft²
WINDOWS (Total Exposed Area = 610 sq.ft.)
Wall -----Overhang-----
#Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening
___ 1 NW 3 Vinyl Low-E Single Yes 0.31 0.18 Y N 4.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 2 NW 3 Vinyl Low-E Single Yes 0.31 0.18 Y N 6.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 3 NW 3 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 4 NE 4 Vinyl Low-E Single Yes 0.29 0.21 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 5 W 5 Vinyl Low-E Single Yes 0.29 0.21 Y N 29.5ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 6 NW 6 Vinyl Low-E Single Yes 0.29 0.21 Y N 29.5ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 7 NE 7 Vinyl Low-E Single Yes 0.29 0.21 Y N 12.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 8 NW 8 Vinyl Low-E Single Yes 0.29 0.21 Y N 29.5ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 9 W 9 Vinyl Low-E Single Yes 0.35 0.20 Y N 94.0ft²16.0 ft 0 in 1.0 ft 4 in None None
___ 10 W 10 Vinyl Low-E Single Yes 0.35 0.20 Y N 94.0ft²16.0 ft 0 in 1.0 ft 4 in None None
___ 11 SE 11 Vinyl Low-E Single Yes 0.29 0.21 Y N 29.5ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 12 NE 15 Vinyl Low-E Single Yes 0.29 0.21 Y N 20.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 13 E 16 Vinyl Low-E Single Yes 0.29 0.21 Y N 20.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 14 SE 17 Vinyl Low-E Single Yes 0.29 0.21 Y N 20.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 15 SE 21 Vinyl Low-E Single Yes 0.29 0.21 Y N 12.5ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 16 SE 24 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²2.0 ft 0 in 1.0 ft 4 in None None
3/1/2022 1:44:18 PM Page 4EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS(Continued)
___ 17 SE 24 Vinyl Low-E Single Yes 0.29 0.21 Y N 23.5ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 18 SW 26 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 19 SW 26 Vinyl Low-E Single Yes 0.29 0.21 Y N 21.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 20 SW 28 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 21 NW 29 Vinyl Low-E Single Yes 0.29 0.21 Y N 30.0ft²16.0 ft 0 in 1.0 ft 4 in None None
INFILTRATION
#Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s)
___ 1 Wholehouse Proposed ACH(50)0.00038 3733 204.80 384.50 0.1061 5.0 All
GARAGE
#Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
___ 1 504 ft²504 ft²64 ft 8 ft 1
MASS
#Mass Type Area Thickness Furniture Fraction Space
___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 FAMILY ROOM
___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 2
___ 3 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BATH 2
___ 4 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 3
___ 5 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BREAKFAST
___ 6 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 KITCHEN
___ 7 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 PANTRY
___ 8 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 LIVING ROOM
___ 9 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 HALL
___ 10 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 POWDER
___ 11 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 LAUNDRY
___ 12 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 CLST.
___ 13 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 FOYER
___ 14 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 DINING
___ 15 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 WIC
___ 16 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 M BATH
___ 17 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 MAST ERBEDROOM
___ 18 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 LIBRARY
HEATING SYSTEM
#System Type Subtype AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block
kBtu/hr Entry Power Volt Current
___ 1 Electric Strip Heat None COP: 1.00 34.0 0.00 0.00 0.00 sys#1 2
___ 2 Electric Strip Heat None COP: 1.00 17.0 0.00 0.00 0.00 sys#2 1
COOLING SYSTEM
#System Type Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block
kBtu/hr cfm
___ 1 Central Unit Split/Single SEER:16.0 58.0 0 0.70 sys#1 2
___ 2 Central Unit Split/Single SEER:16.0 24.0 0 0.70 sys#2 1
3/1/2022 1:44:18 PM Page 5EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
#System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length
___ 1 Electric None LAUNDRY 0.95 (0.93)50.00 gal 61 gal 120 deg Standard None 132
Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
System Type length length power Connected Flow Eff
___ 1 No NA NA NA No NA NA NA None
DUCTS
Duct ---------Supply------------------Return---------Air CFM 25 CFM 25 HVAC #
#Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool
___ 1 Attic 6.0 325 ft²Attic 6.0 65 ft²Default Leakage Attic (Default)(Default)1 1
___ 2 Attic 6.0 150 ft²Attic 6.0 65 ft²Default Leakage Attic (Default)(Default)2 2
TEMPERATURES
Programable Thermostat: N Ceiling Fans: N
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec
Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
___ Cooling (WD)AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
___ Heating (WD)AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
___ Heating (WEH)AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
3/1/2022 1:44:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6
CHECK2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name:SCHWARTZ RENO Builder Name:
Street:2601 NW JUNIPER COURT Permit Office:ST. LUCIE COUNTY
City, State, Zip:PALM CITY, FL, Permit Number:
Owner:Jurisdiction:
Design Location:FL, Fort Pierce County:St. Lucie(Florida Climate Zone 2)
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope.Air-permeable insulation shall
requirements The exterior thermal envelope contains a continuous air barrier.not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed.shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed.Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with
sealed.a material having a thermal resistance of R-3 per
Knee walls shall be sealed.inch minimum
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights The space between window/door jambs and framing, and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier.Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation.maintain permanent contact with the underside of
above-garage subfloor decking, or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors)of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation
with a Class I vapor retarder with overlapping joints taped.shall be permanently attached to the crawlspace walls.
Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and
conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building
envelope shall be sealed to the finished surface.thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall
on exterior wall and tubs shall separate them from the showers and tubs.be insulated.
Electrical/phone box The air barrier shall be installed behind electrical or
on exterior walls communication boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor, wall covering
or ceiling penetrated by the boot.
Concealed When required to be sealed, concealed fire sprinklers shall only
sprinklers be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
3/1/2022 1:44:18 PM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home.
2601 NW JUNIPER COURT,PALM CITY,FL,
1. New construction or existing New (From Plans)
2. Single family or multiple family Detached
3. Number of units, if multiple family 1
4. Number of Bedrooms 3
5. Is this a worst case?No
6. Conditioned floor area above grade (ft²)3733
Conditioned floor area below grade (ft²)0
7. Windows**Description Area
a. U-Factor:Sgl, U=0.29 412.00 ft2
S H G C :SHGC=0.21
b. U-Factor:Sgl, U=0.35 188.00 ft2
S H G C :SHGC=0.20
c. U-Factor:Sgl, U=0.31 10.00 ft2
S H G C :SHGC=0.18
Area Weighted Average Overhang Depth:7.003 ft
Area Weighted Average SHGC:0.206
8. Skylights Description Area
U - F a c t o r : ( A V G )N/A N/A ft2
S H G C ( A V G ) :N/A
9. Floor Types I n s u l a t i o n Area
a. Slab-On-Grade Edge Insulation R= 0.0 3730.10 f t2
b. N/A R = f t2
c. N/A R = f t2
10. Wall Types(3890.0 sqft.) I n s u l a t i o n Area
a. Concrete Block - Int Insul, ExteriorR=4.1 3614.00 ft2
b. Frame - Wood, Adjacent R=11.0 276.00 ft2
c. N/A R = f t2
d. N/A R= f t2
11. Ceiling Types(3733.0 sqft.) I n s u l a t i o n Area
a. Under Attic (Vented)R=30.0 3733.00 ft2
b. N/A R= f t2
c. N/A R= f t2
12. Ducts, location & insulation level R ft2
a. a. Sup: Attic, Ret: Attic, AH: Attic 6 325
b. b. Sup: Attic, Ret: Attic, AH: Attic 6 150
c .
13. Cooling Systems k B t u / h r Efficiency
a. Central Unit 58.0 SEER:16.00
b. Central Unit 24.0 SEER:16.00
14. Heating Systems k B t u / h r Efficiency
a. Electric Strip Heat 34.0 COP:1.00
b. Electric Strip Heat 17.0 COP:1.00
15. Hot Water Systems
a. Electric Cap: 50 gallons
EF: 0.950
b. Conservation features
None
16. Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ___________________________________Date: _________________________
Address of New Home: 2601 NW JUNIPER COURT City/FL Zip: PALM CITY,FL,
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/1/2022 1:44:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1