HomeMy WebLinkAboutAPPROVED, FL14083_R26_TPOhighlights NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT Carlisle SynTec Systems P.O. Box 7000 Carlisle, PA 17013 (717) 245-7264 Evaluation Report C33680.09.10-R26 FL14083-R26 Date of Issuance: 09/08/2010 Revision 26: 02/16/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Carlisle Sure-Weld TPO Single Ply Roof Systems for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus 98-pages of Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/16/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL14083-R26 Carlisle Sure-Weld TPO Single Ply Roof Systems Revision 26: 02/16/2021 Page 2 of 5 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Single Ply Roof Systems Compliance Statement: Carlisle Sure-Weld TPO Single Ply Roof Systems, as produced by Carlisle SynTec Systems, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2015 1504.6 Physical properties ASTM G155 2013 1504.7 Impact resistance FM 4470 2016 1507.11.2 Material standard ASTM D6163 2015 1507.13.2 Material standard ASTM D6878 2013 3. REFERENCES: Entity Exam Reference Date Entity Exam Reference Date ACRC (TST4671) Wind 07-051 08/29/2007 FM App (TST1867) FM 4474 3037400 09/02/2009 ACRC (TST4671) Wind 07-059 10/15/2007 FM App (TST1867) FM 4474 3033356 10/09/2009 ACRC (TST4671) Wind 10-009 05/19/2010 FM App (TST1867) FM 4474 3034297 11/13/2009 ACRC (TST4671) Wind 10-018 08/25/2010 FM App (TST1867) FM 4474 3036762 03/08/2011 ACRC(TST4671) Wind 10-019 08/25/2010 FM App (TST1867) FM 4474 3041535 06/08/2011 ACRC(TST4671) Wind 11-034 06/28/2011 FM App (TST1867) FM 4474 3039340 06/24/2011 ACRC(TST4671) Wind 11-035 06/28/2011 FM App (TST1867) FM 4474 3043858 08/25/2011 ACRC(TST4671) Wind 11-036 06/29/2011 FM App (TST1867) FM 4474 3041797 10/13/2011 ACRC(TST4671) Wind 11-037 06/29/2011 FM App (TST1867) FM 4474 3039073 11/22/2011 ACRC(TST4671) Wind 15-002 03/30/2015 FM App (TST1867) FM 4470 1X9A4.AM 12/06/2011 ACRC(TST4671) Wind 15-008 04/02/2015 FM App (TST1867) FM 4470 3000919 12/06/2011 ACRC(TST4671) Wind 15-009 04/06/2015 FM App (TST1867) FM 4470 3044748 12/06/2011 ACRC(TST4671) Wind 15-011 07/07/2015 FM App (TST1867) FM 4474 3040260 02/27/2012 ACRC(TST4671) Wind 15-012 07/07/2015 FM App (TST1867) FM 4474 3041799 03/29/2012 ACRC(TST4671) Wind 15-015 07/09/2015 FM App (TST1867) FM 4474 3043824 04/06/2012 ACRC(TST4671) Wind 15-016 07/09/2015 FM App (TST1867) FM 4474 3039762 09/07/2012 ACRC(TST4671) Wind 15-018 07/10/2015 FM App (TST1867) FM 4474 3047327 09/13/2012 ACRC(TST4671) Wind 15-019 07/14/2015 FM App (TST1867) FM 4474 3040639 09/18/2012 ACRC(TST4671) Wind 15-020 07/14/2015 FM App (TST1867) FM 4474 3043858 09/25/2012 ACRC(TST4671) Wind 15-021 07/15/2015 FM App (TST1867) FM 4474 3042075 10/23/2012 ACRC(TST4671) Wind 15-037 12/28/2015 FM App (TST1867) FM 4474 3045953 02/13/2013 ACRC(TST4671) Wind 15-038 12/28/2015 FM App (TST1867) FM 4474 797 (ribbon HP-NB) 04/25/2013 ACRC(TST4671) Wind 15-041 12/30/2015 FM App (TST1867) FM 4451 3049232 09/11/2013 ACRC(TST4671) Wind 15-043 01/04/2016 FM App (TST1867) FM 4474 3049189 03/11/2014 ACRC(TST4671) Wind 15-045 01/11/2016 FM App (TST1867) FM 4474 3048753 09/16/2014 ACRC(TST4671) Wind 15-046 01/11/2016 FM App (TST1867) FM 4474 3051392 (data) 10/15/2014 ACRC(TST4671) Wind 15-047 01/12/2016 FM App (TST1867) FM 4474 3054838 02/13/2015 ATI (TST1588) FM 4470 01-37050.01 03/13/2000 FM App (TST1867) FM 4474 3055462 04/01/2015 ATI (TST1588) FM 4470 01-39152.01 03/28/2001 FM App (TST1867) FM 4474 3055227 05/21/2015 ATI (TST1588) FM 4470 63524.01-111-47 03/16/2006 FM App (TST1867) FM 4474 3053933 06/30/2015 ATI (TST1588) FM 4470 76506.01-111-47 09/06/2007 FM App (TST1867) FM 4451 3054498 11/30/2015 ATI (TST1588) FM 4470 77891.01-111-47 10/26/2007 FM App (TST1867) FM 4474 3050229 01/25/2016 ATI (TST1588) FM 4474 C1141.01-109-18 09/13/2012 FM App (TST1867) FM 4474 3058125 02/04/2016 ATI (TST1588) TAS 114 D7772.01-109-18 07/09/2014 FM App (TST1867) FM 4474 3055167 02/10/2016 ATI (TST1588) TAS 114 D7772.02-109-18 07/14/2014 FM App (TST1867) FM 4474 3055824 05/31/2016 ATI (TST1588) TAS 114 E4981.01-109-18 02/26/2015 FM App (TST1867) FM 4474 3058058 11/04/2016 CTL (TST1577) FM 4474 CTLA-105R 10/13/2008 FM App (TST1867) FM 4474 RR206411 09/26/2018 CTL (TST1577) FM 4474 CTLA-105R-1 10/13/2008 FM App (TST1867) FM 4474 3056745 09/28/2016 CTL (TST1577) FM 4474 CTLA-105R-2 10/13/2008 FM App (TST1867) FM 4474 3058125 12/06/2016 CTL (TST1577) FM 4474 CTLA-106R 10/16/2008 FM App (TST1867) FM 4474 3062422 (data) 05/25/2017 CTL (TST1577) FM 4474 CTLA-106R-1 10/16/2008 FM App (TST1867) FM 4474 3062422 (data) 01/05/2018 CTL (TST1577) FM 4474 CTLA-106R-2 10/16/2008 FM App (TST1867) FM 4474 PR449852 (data) 03/29/2018 CTL (TST1577) FM 4474 CTLA-106R-3 10/16/2008 FM App (TST1867) FM 4474 3058463 05/22/2018 CTL (TST1577) FM 4474 CTLA-106R-4 10/16/2008 FM App (TST1867) FM 4470 3063373 07/23/2018 NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL14083-R26 Carlisle Sure-Weld TPO Single Ply Roof Systems Revision 26: 02/16/2021 Page 3 of 5 Entity Exam Reference Date Entity Exam Reference Date CTL (TST1577) TAS 117 CTLA 111R 01/13/2009 FM App (TST1867) FM 4474 PR451012 (data) 09/11/2018 ERD (TST 6049) Physicals U0215.05.06-1 05/30/2006 FM App (TST1867) FM 4474 PR449651 09/25/2018 ERD (TST 6049) FM 4470 E9490.03.08 03/25/2008 FM App (TST1867) FM 4474 3063085 10/05/2018 ERD (TST 6049) Criticality A35880.04.12-R1 10/26/2012 FM App (TST1867) FM 4474 PR451012 (data) 10/11/2018 ERD (TST 6049) FM 4474 SC10010.02.16 02/29/2016 FM App (TST1867) FM 4474 PR452297 (data) 12/05/2018 ERD (TST 11294) FM 4474 13380.01.17 01/27/2017 FM App (TST1867) FM 4474 PR452297 (data) 12/06/2018 ERD (TST 6049) FM 4474 CRL-SC13450.01.17 01/31/2017 FM App (TST1867) FM 4474 PR451012 (data) 12/13/2018 ERD (TST 11294) FM 4474 CLT16160.08.17-1 08/28/2017 FM App (TST1867) FM 4474 PR452773 (data) 01/30/2019 ERD (TST 11294) FM 4474 CLT16160.08.17-2 08/28/2017 FM App (TST1867) FM 4474 PR452773 (data) 02/01/2019 ERD (TST 6049) Criticality SFS-SC12250.10.17 10/23/2017 FM App (TST1867) FM 4474 PR451012 (data) 02/01/2019 FM App (TST1867) FM 4470 0V7A4.AM 06/10/1992 FM App (TST1867) FM 4474 3059662 02/05/2019 FM App (TST1867) FM 4470 3Z9A1.AM 10/15/1997 FM App (TST1867) FM 4474 PR453924(data) 06/19/2019 FM App (TST1867) FM 4470 3001580 11/16/1998 FM App (TST1867) FM 4474 PR451520 (data) 05/02/2019 FM App (TST1867) FM 4470 3001522 03/26/1999 FM App (TST1867) FM 4474 PR453044 05/30/2019 FM App (TST1867) FM 4470 3003393 03/30/1999 FM App (TST1867) FM 4474 3060914 06/20/2019 FM App (TST1867) FM 4470 3003337 06/11/1999 FM App (TST1867) FM 4474 PR453922 08/08/2019 FM App (TST1867) FM 4470 3006110 06/13/2001 FM App (TST1867) FM 4474 PR453353 01/31/2020 FM App (TST1867) FM 4470 3011329 06/10/2002 FM App (TST1867) FM 4474 PR453923 02/02/2020 FM App (TST1867) FM 4470 3012879 04/04/2003 FM App (TST1867) FM 4474 PR451812 04/24/2020 FM App (TST1867) FM 4470 3013584 06/27/2003 FM App (TST1867) FM 4474 RR223958 06/10/2020 FM App (TST1867) FM 4470 3014692 08/05/2003 FM App (TST1867) FM 4474 RR224173 06/30/2020 FM App (TST1867) FM 4470 3016355 09/15/2003 M-D (CER1592) Wind Uplift 12-0216.01 03/08/2012 FM App (TST1867) FM 4470 3019890 12/16/2004 M-D (CER1592) Wind Uplift 13-0617.20 09/05/2013 FM App (TST1867) FM 4474 3017662 06/07/2005 M-D (CER1592) Wind Uplift 13-0307.02 09/26/2013 FM App (TST1867) FM 4474 3023032 07/20/2005 NEMO (TST 6049) D6878 (PA) 4-CRL-18-002.04.18-1 04/03/2018 FM App (TST1867) FM 4474 3018631 11/03/2005 NEMO (TST 6049) D6878 (MS) 4-CRL-18-002.04.18-2A 04/03/2018 FM App (TST1867) FM 4474 3023999 11/08/2005 NEMO (TST 6049) FM 4474 4-CRL-18-003.05.18 05/15/2018 FM App (TST1867) FM 4474 3020845 01/25/2006 NEMO (TST 6049) FM 4474 CRL-SC16815.06.18 06/07/2018 FM App (TST1867) FM 4474 3021941 03/20/2006 NEMO (TST 6049) FM 4474 4L-CEL-18-001.12.18 12/14/2018 FM App (TST1867) FM 4474 3023340 03/20/2006 NEMO (TST 11294) FM 4474 2-CRL-18-002.04.18 05/15/2018 FM App (TST1867) FM 4474 3023458 07/18/2006 NEMO (TST 6049) Criticality 4S-CRL-18-005.11.18-R1 01/17/2019 FM App (TST1867) FM 4474 3024593 07/27/2006 NEMO (TST 11294) FM 4474 2a-CRL-19-LWWUS-01.A 05/13/2019 FM App (TST1867) FM 4474 3022174 09/25/2006 NEMO (TST 6049) D6878 (UT) 4r-CRL-19-SSTHP-02.A 08/23/2019 FM App (TST1867) FM 4474 3021235 06/01/2007 NEMO (TST 11294) FM 4474 2a-CRL-19-LWWUS-02.A 01/14/2020 FM App (TST1867) FM 4474 3026964 07/25/2007 NEMO (TST 6049) FM 4474 4L-CRL-18-003.12.18 01/14/2020 FM App (TST1867) FM 4470 3030926 08/07/2007 NEMO (TST 6049) FM 4474 4a-CRL-19-LSWUS-01.A 01/14/2020 FM App (TST1867) FM 4474 3028438 08/22/2007 NEMO (TST 11294) FM 4474 2-CRL-18-002.10.18-2-R1 01/23/2020 FM App (TST1867) FM 4474 3031350 09/27/2007 NEMO (TST 6049) FM 4474 4a-CRL-19-LSWUS-02.A 03/05/2020 FM App (TST1867) FM 4474 3030536 10/09/2007 NEMO (TST 6049) D6878 (MS) 4r-CRL-19-SSTHP-01.A 07/16/2020 FM App (TST1867) FM 4474 3028655 11/09/2007 NEMO (TST 6049) D6878 (UT) 4r-CRL-20-SSTHP-02.A 10/15/2020 FM App (TST1867) FM 4474 3026951 01/21/2008 NEMO (TST 6049) D6878 (MS) 4r-CRL-20-SSTHP-02.B 10/15/2020 FM App (TST1867) FM 4474 3031349 05/13/2008 NEMO (TST 6049) D6878 (UT) 4r-CRL-20-SSTHP-02.C 10/15/2020 FM App (TST1867) FM 4474 3031765 07/21/2008 NEMO (TST 6049) D6878 (MS) 4r-CRL-20-SSTHP-03.A 10/15/2020 FM App (TST1867) FM 4474 3029840 09/08/2008 NEMO (TST 6049) D6878 (UT) 4r-CRL-20-SSTHP-03.B 10/15/2020 FM App (TST1867) FM 4474 3033217 12/08/2008 PRI CMT(TST5878) FM 4474 CST-016-02-01 05/04/2011 FM App (TST1867) FM 4474 3034985 12/15/2008 PRI CMT(TST5878) FM 4474 CST-016-02-01 05/05/2011 FM App (TST1867) FM 4474 3034066 04/14/2009 UL, LLC. (TST9628) UL 1897 08CA15815 10/22/2008 FM App (TST1867) FM 4474 3034776 08/07/2009 UL, LLC. (QUA9625) QA Service Confirmation 12/14/2018 UL, LLC. (QUA9625) QA Florida BCIS Current 4. PRODUCT DESCRIPTION: This Evaluation Report covers Sure-Weld TPO Single-Ply Roof Membrane Systems installed in accordance with Carlisle SynTec Systems published installation instructions and the Limitations / Conditions of Use herein . TABLE 1: EVALUATED MEMBRANES Type Product Material Standard Plant(s) Reference Type Grade Roof Cover or Cap Ply Sure-Weld 45, 60-mil ASTM D6878 N/A N/A MS, PA, UT Sure-Weld EXTRA 72, 80-mil ASTM D6878 N/A N/A MS, PA, UT Sure-Weld HS 60, 80-mil ASTM D6878 N/A N/A MS Sure-Weld FleeceBACK FR 60-mil ASTM D6878 N/A N/A UT Sure-Weld FleeceBACK 100, 115 or 135 45, 60, 80-mil ASTM D6878 N/A N/A MS NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL14083-R26 Carlisle Sure-Weld TPO Single Ply Roof Systems Revision 26: 02/16/2021 Page 4 of 5 TABLE 1: EVALUATED MEMBRANES Type Product Material Standard Plant(s) Reference Type Grade Roof Cover or Cap Ply Sure-Weld FleeceBACK 115 45, 60, 80-mil ASTM D6878 N/A N/A UT Sure-Weld AFX 120, AFX 135 or AFX 155 45, 60, 80-mil ASTM D6878 N/A N/A MS Sure-Weld SAT-TPO 60-mil ASTM D6878 N/A N/A UT Sure-Weld FleeceBACK® RL™ with RapidLock Technology 60-mil ASTM D6878 N/A N/A MS Base Ply or Vapor Barrier Membranes SureMB 90 Base ASTM D6163 I S TX SureMB 90TG Base ASTM D6163 I S TX SureMB 120TG Base ASTM D6163 I S TX 5. LIMITATIONS: 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classificat ion. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low-slope roofs. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.6.2 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. 5.7.1 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL14083-R26 Carlisle Sure-Weld TPO Single Ply Roof Systems Revision 26: 02/16/2021 Page 5 of 5 5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: Carlisle Sure-Weld TPO Single Ply Roof Systems shall be installed in accordance with Carlisle SynTec Systems published installation instructions, subject to the Limitations / Conditions of Use noted herein. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC – QUA9625; (414) 248-6409; karen.buchmann@ul.com - THE 98-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 1 of 98 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 6-7 1C Wood New, Reroof (Tear-Off), Recover C-2 Mechanically Attached Insulation, Plate-Bonded Roof Cover 7-8 1D Wood New, Reroof (Tear-Off), Recover D-1 Insulated, Mechanically Attached Roof Cover 9 1E Wood New, Reroof (Tear-Off), Recover D-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 9 1F Wood New, Reroof (Tear-Off), Recover E-1 Non-Insulated, Mechanically Attached Roof Cover 10 1G Wood New, Reroof (Tear-Off), Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 10 1H Wood New, Reroof (Tear-Off), Recover G Optional Insulation, Loose-Laid Roof Cover, Pressure Equalizing Vent 10 2A Steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 11-12 2B Steel or structural concrete New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12-21 2C Steel or structural concrete New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Base Ply, Bonded Roof Cover 21-22 2D Steel New, Reroof (Tear-Off), Recover B-2 Mech. Attached Thermal Barrier, Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 23-24 2E Steel or structural concrete New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 24-35 2F Steel or structural concrete New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Base Ply, Bonded Roof Cover 36 2G Steel New, Reroof (Tear-Off), Recover C-2 Mechanically Attached Insulation, Plate-Bonded Roof Cover 36-39 2H Steel or structural concrete New, Reroof (Tear-Off), Recover D-1 Insulated, Mechanically Attached Roof Cover (Stress Plates) 40-46 2I Steel or structural concrete New, Reroof (Tear-Off), Recover D-1 Insulated, Mechanically Attached Roof Cover (RUSS Strips) 46 3A Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 47-67 3B Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Base Ply, Bonded Roof Cover 67-68 3C Structural concrete New, Reroof (Tear-Off), Recover C-2 Mechanically Attached Insulation, Plate-Bonded Roof Cover 68-70 3D Structural concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 71 3E Structural concrete New, Reroof (Tear-Off), Recover G Optional Insulation, Loose-Laid Roof Cover, Pressure Equalizing Vent 71 4A Lightweight concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 72-74 4B Lightweight concrete New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 74 4C Lightweight concrete / steel New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 75-77 4D Lightweight concrete / concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 78-79 5A Cementitious wood fiber New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 80-81 5B Cementitious wood fiber New, Reroof (Tear-Off), Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 82 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 83-84 6B Existing gypsum Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 84 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 85-89 7B Various Recover A-1 Bonded Insulation, Bonded Base Ply, Bonded Roof Cover 90-91 7C Steel Recover C-2 Mechanically Attached Insulation, Plate-Bonded Roof Cover 92-93 7D Steel Recover D-1 Insulated, Mechanically Attached Roof Cover 93 7E Steel Recover D-2 Insulated, Mechanically Attached Roof Cover (RUSS Strips) 94 7F Various Recover E-1 Non-Insulated, Mechanically Attached Roof Cover 95 7G Various Recover F-1 Non-Insulated, Bonded Roof Cover 96 7H Various Recover F-2 New LWC over Existing Roof, Bonded Roof Cover 97 8A/8B Guidance / Limitations for use of Hilti fasteners in Type B steel deck securement beneath Carlisle SynTec roof systems 98 NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 2 of 98 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. ➢ As-tested roof cover performance in accordance with FM 4474 and TAS 114, Appendix J indicates min. 22 ga., Type B, Grade 40 steel deck at max. 6 ft spans attached with 5/8-inch diameter puddle welds spaced 6” o.c., with deck side laps secured max. 24” o.c. w/ ¼”-14x1” long self-tapping hex-head screws, may be used for roof assemblies over steel deck up to a maximum design pressure of -60.0 psf. This does not preclude Note 1 above. ➢ Tables 8A and 8B provide guidance / limitations associated with use of fasteners from Hilti, Inc. to secure steel decking to structural members 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Sure-Seal HP Fastener with Sure-Seal Insulation Plate. Minimum 1-inch wood penetration. ➢ Steel Deck: Sure-Seal HP Fastener with Sure-Seal Insulation Plate. Minimum ¾-inch steel penetration, engage the top flute of the steel deck. ➢ Structural Concrete: Sure-Seal HD 14-10 Concrete Fastener, Carlisle CD-10 or HP Concrete Spike (1/4) with Sure-Seal Insulation Plate; Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). ➢ Carlisle INSUL-FAST Fastener may be used in place of Sure-Seal HP Fastener for preliminary attachment purposes over wood and steel deck. 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. ➢ Hot asphalt: Full-coverage at 25 lbs/square. ➢ FAST 100LV (FULL): Full-coverage at 1 gal./square. ➢ FAST 100LV (RIBBON): Continuous ribbons, 12-inch o.c. ➢ FAST Dual-Tank (FAST DT) (FULL): Continuous ribbons, 4-inch o.c. ➢ FAST Dual-Tank (FAST DT) (RIBBON): Continuous ribbons, 12-inch o.c. Note: When installing multiple layers of insulation, FAST Dual-Tank beads shall be placed perpendicular to those placed for attachment of the previous layer ➢ Flexible FAST (FULL): Continuous ribbons, 4-inch o.c. or spray-applied at 1 gal./square. ➢ Flexible FAST (SPLATTER): Splatter-applied at 0.5 gal/square (wet) = 4.7 lb/square (dry) ➢ Flexible FAST (RIBBON): Continuous ribbons, 12-inch o.c. ➢ Flexible FAST Dual-Tank (Flexible FAST DT) (FULL): Continuous ribbons, 4-inch o.c. or spray-applied at 1 gal./square. ➢ Flexible FAST Dual-Tank (Flexible FAST DT) (RIBBON): Continuous ribbons, 12-inch o.c. ➢ OlyBond 500 (OB500): Continuous ribbons, 12-inch o.c. using PaceCart, SpotShot or Canisters. Note: OlyBond 500 Green may be used where OlyBond 500 is referenced. ➢ Note: FULL applications may be used where RIBBON applications are referenced. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 3 of 98 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. ➢ FAST 100LV or Flexible FAST: MDP = -157.5 psf (Min. 0.5-inch thick) ➢ OlyBond 500 (OB500): MDP = -187.5 psf (Min. 0.5-inch thick) 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS MEMBRANE ADHESIVE APPLICATION RATE Sure-Weld or Sure-Weld HS Sure-Weld Bonding Adhesive Contact (both sides) 60 ft2/gal Sure-Weld or Sure-Weld HS Aqua Base 120 Bonding Adhesive (Aqua Base 120) Contact (both sides) 120 ft2/gal Sure-Weld or Sure-Weld HS Low VOC Bonding Adhesive (LVOC BA) Contact (both sides) 60 ft2/gal Sure-Weld or Sure-Weld HS Sure-Seal 90-8-30A Bonding Adhesive Contact (both sides) 60 ft2/gal Sure-Weld CAV-GRIP III Adhesive/Primer (CAV-GRIP III AP) Contact (both sides) 110 ft2/gal Sure-Weld FleeceBACK Aqua Base 120 Bonding Adhesive Wet lay (substrate) 120 ft2/gal Sure-Weld FleeceBACK HydroBond Water-Based Adhesive (HydroBond WB) Wet lay (substrate) 100 to 133 ft2/gal Sure-Weld FleeceBACK FAST 100LV, FAST Dual-Tank (FAST DT) Wet lay (substrate) RIBBON spaced as noted herein or FULL Coverage = 1 gal/square or continuous ribbons, maximum 4-inch o.c. Sure-Weld FleeceBACK Flexible FAST Wet lay (substrate) RIBBON spaced as noted herein or FULL Coverage = 1 gal/square or continuous ribbons, maximum 4-inch o.c. or splatter-applied at 0.5 gal/square (wet) = 4.7 lb/square (dry) NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 4 of 98 MEMBRANE / ADHESIVE COMBINATIONS MEMBRANE ADHESIVE APPLICATION RATE Sure-Weld FleeceBACK Flexible FAST Dual-Tank (Flexible FAST DT) Wet lay (substrate) RIBBON spaced as noted herein or FULL Coverage = 1 gal/square, continuous ribbons, maximum 4-inch o.c. or splatter-applied at 0.4 gal/square (wet) = 3.7 lb/square (dry) Sure-Weld AFX Carlisle Cold Applied Adhesive (C-CAA) Wet lay (substrate) 1.5 gal/square Sure-Weld AFX Hot asphalt Wet lay (substrate) 25 lbs/square Sure-Weld FleeceBACK® RL™ VELCRO® Brand Securable Solutions Only for use over InsulBase RL or SecurShield HD RL substrates. Roof cover is broomed into place and rolled with 150 lb roller to establish contact. 15A For single-ply membranes in System Type D-1 steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 15B For System Type C-2 (induction weld), care shall be taken to ensure that the plates do not line-up with membrane seams. This condition may preclude proper induction welding of the membrane to the plates. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A OR 3B: OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF)* TYPE APPLICATION C-VB-1. 702 Primer, 702 LV Primer, CAV-GRIP Primer or CAV-GRIP III LVOC-AP VapAir Seal 725TR Self-adhering Flexible FAST (RIBBONS, 12-inch o.c.) -157.5 C-VB-2. 702 Primer, 702 LV Primer, CAV-GRIP Primer or CAV-GRIP III LVOC-AP VapAir Seal 725TR Self-adhering Flexible FAST DT (RIBBONS, 12-inch o.c.) -172.5 C-VB-3. 702 Primer, 702 LV Primer, CAV-GRIP Primer or CAV-GRIP III LVOC-AP VapAir Seal 725TR Self-adhering Flexible FAST or Flexible FAST DT (RIBBONS, 6-inch o.c.) -270.0 C-VB-4. CAV-GRIP Primer or CAV-GRIP III LVOC-AP VapAir Seal 725TR Self-adhering Flexible FAST (FULL COVERAGE, 1 gal/square) -427.5 C-VB-5. ASTM D41 SureMB 90 Base Hot-asphalt Hot asphalt at 25 lbs/square -172.5 C-VB-6. ASTM D41 SureMB 90TG or 120TG Base Torch-applied Hot asphalt at 25 lbs/square -180.0 C-VB-7. ASTM D41 SureMB 90TG or 120TG Base Torch-applied Flexible FAST or Flexible FAST DT (RIBBON, 12-inch o.c.) -307.5 C-VB-8. ASTM D41 SureMB 90TG or 120TG Base Torch-applied Flexible FAST or Flexible FAST DT (RIBBON, 6-inch o.c.) -495.0 17 The following products are interchangeable within the scope of this Evaluation Report: ACCEPTABLE ALTERNATES Listed Product Alternate Sure-Weld Sure-Weld EXTRA and Sure-Weld HS Sure-Weld FleeceBACK Includes 100, 115 and 135 Sure-Weld AFX Includes AFX 120, AFX 135 and AFX 155 InsulBase InsulBase NH, H-Shield, H-Shield NH SecurShield SecurShield NH, H-Shield CG, H-Shield CG NH SecurShield HD SecurShield HD NH, H-Shield ND, H-Shield HD NH SecurShield HD Plus SecurShield HD Plus NH, H-Shield HD90, H-Shield HD90 NH SecurShield HD Composite H-Shield HD Composite StormBase H-Shield NB 18 For System Types B-1, B-2, C-1, C-2, D-1 or Type D-2, VapAir Seal MD may be installed atop the roof deck prior to installation of the insulation and roof cover. Refer to FM Loss Prevention Data Sheet 1-29 (February 2020) for design and installation recommendations. 19 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 5 of 98 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Vapor Barrier Base Insulation Layer Top Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Membrane Application SURE-WELD OR SURE-WELD HS MEMBRANE APPLICATIONS: W-1. 7/16-inch APA rated OSB; 2 ft spans None Min. 1.5-inch InsulBase, SecurShield Flexible FAST or Flexible FAST DT (RIBBON) (Optional) Additional layer(s) base insulation Flexible FAST or Flexible FAST DT (RIBBON) Sure-Weld CAV-GRIP III AP, LVOC BA or Sure-Weld BA -45.0* W-2. 7/16-inch APA rated OSB; 2 ft spans None (Optional) Min. 1.5-inch InsulBase, SecurShield Flexible FAST or Flexible FAST DT (RIBBON) Insulation: (Optional) Additional layer(s) base insulation Coverboard: Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch SecurShield HD, SecurShield HD Plus or EcoStorm VSH Flexible FAST or Flexible FAST DT (RIBBON) Sure-Weld CAV-GRIP III AP, LVOC BA or Sure-Weld BA -45.0* W-3. Min. 15/32-inch APR rated CDX plywood; 2 ft spans None Min. 1.5-inch InsulBase, SecurShield Flexible FAST or Flexible FAST DT (RIBBON) (Optional) Additional layer(s) base insulation Flexible FAST or Flexible FAST DT (RIBBON) Sure-Weld CAV-GRIP III AP, LVOC BA or Sure-Weld BA -67.5 W-4. Min. 15/32-inch APR rated CDX plywood; 2 ft spans None (Optional) Min. 1.5-inch InsulBase, SecurShield Flexible FAST or Flexible FAST DT (RIBBON) Insulation: (Optional) Additional layer(s) base insulation Coverboard: Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch SecurShield HD, SecurShield HD Plus or EcoStorm VSH Flexible FAST or Flexible FAST DT (RIBBON) Sure-Weld CAV-GRIP III AP, LVOC BA or Sure-Weld BA -67.5 SURE-WELD FLEECEBACK MEMBRANE APPLICATIONS (FULL BOND): W-5. 7/16-inch APA rated OSB; 2 ft spans None Min. 1.5-inch InsulBase, SecurShield Flexible FAST or Flexible FAST DT (RIBBON) (Optional) Additional layer(s) base insulation Flexible FAST or Flexible FAST DT (RIBBON) Sure-Weld FleeceBACK Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -45.0* W-6. 7/16-inch APA rated OSB; 2 ft spans None (Optional) Min. 1.5-inch InsulBase, SecurShield Flexible FAST or Flexible FAST DT (RIBBON) Insulation: (Optional) Additional layer(s) base insulation Coverboard: Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch SecurShield HD, SecurShield HD Plus or EcoStorm VSH Flexible FAST or Flexible FAST DT (RIBBON) Sure-Weld FleeceBACK Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -45.0* W-7. Min. 15/32-inch APR rated CDX plywood; 2 ft spans None Min. 1.5-inch InsulBase, SecurShield Flexible FAST or Flexible FAST DT (RIBBON) (Optional) Additional layer(s) base insulation Flexible FAST or Flexible FAST DT (RIBBON) Sure-Weld FleeceBACK Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -67.5 W-8. Min. 15/32-inch APR rated CDX plywood; 2 ft spans None (Optional) Min. 1.5-inch InsulBase, SecurShield Flexible FAST or Flexible FAST DT (RIBBON) Insulation: (Optional) Additional layer(s) base insulation Coverboard: Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch SecurShield HD, SecurShield HD Plus or EcoStorm VSH Flexible FAST or Flexible FAST DT (RIBBON) Sure-Weld FleeceBACK Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 6 of 98 TABLE 1B: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach SURE-WELD OR SURE-WELD HS MEMBRANE APPLICATIONS: W-9. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SecurShield HD, SecurShield HD Plus or EcoStorm VSH Carlisle InsulFast with SecurFast Insulation Fastening Plate 1 per 2.0 ft² Sure-Weld / CAV-GRIP III AP, LVOC BA or Sure-Weld BA -30.0 W-10. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SecurShield HD, SecurShield HD Plus or EcoStorm VSH Carlisle InsulFast with Insulation Fastening Plate 1 per 2.0 ft² Sure-Weld / CAV-GRIP III AP, LVOC BA or Sure-Weld BA -37.5 W-11. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Carlisle InsulFast with Insulation Fastening Plate 1 per 4.0 ft² Sure-Weld / CAV-GRIP III AP, LVOC BA or Sure-Weld BA -45.0* W-12. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Carlisle InsulFast with Insulation Fastening Plate 1 per 2.7 ft² Sure-Weld / CAV-GRIP III AP, LVOC BA or Sure-Weld BA -45.0 W-13. Min. 23/32-inch plywood (Optional) One or more layers, any combination, loose laid Min 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft² Sure-Weld / CAV-GRIP III AP or LVOC BA -45.0* W-14. Min. 19/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, InsulBase, SecurShield or ENRGY 3 Note 2 1 per 2.0 ft² Sure-Weld / Aqua Base 120, CAV-GRIP III AP or Sure-Weld BA -45.0* W-15. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Carlisle InsulFast with Insulation Fastening Plate 1 per 2.0 ft² Sure-Weld / CAV-GRIP III AP, LVOC BA or Sure-Weld BA -60.0 W-16. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Carlisle InsulFast with Insulation Fastening Plate 1 per 1.8 ft² Sure-Weld / CAV-GRIP III AP, LVOC BA or Sure-Weld BA -67.5 W-17. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Carlisle InsulFast with Insulation Fastening Plate 1 per 2.0 ft² Sure-Weld / CAV-GRIP III AP, LVOC BA or Sure-Weld BA -75.0 SURE-WELD FLEECEBACK MEMBRANE APPLICATIONS (FULL BOND): W-18. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SecurShield HD, SecurShield HD Plus or EcoStorm VSH Carlisle InsulFast with SecurFast Insulation Fastening Plate 1 per 2.0 ft² Sure-Weld FleeceBACK / Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -30.0 W-19. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SecurShield HD, SecurShield HD Plus or EcoStorm VSH Carlisle InsulFast with Insulation Fastening Plate 1 per 2.0 ft² Sure-Weld FleeceBACK / Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -37.5 W-20. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Carlisle InsulFast with Insulation Fastening Plate 1 per 4.0 ft² Sure-Weld FleeceBACK / Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -45.0* W-21. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Carlisle InsulFast with Insulation Fastening Plate 1 per 2.7 ft² Sure-Weld FleeceBACK / Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 7 of 98 TABLE 1B: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach W-22. Min. 23/32-inch plywood (Optional) One or more layers, any combination, loose laid Min 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft² Sure-Weld FleeceBACK / Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -45.0* W-23. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Carlisle InsulFast with Insulation Fastening Plate 1 per 2.0 ft² Sure-Weld FleeceBACK / Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -60.0 W-24. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Carlisle InsulFast with Insulation Fastening Plate 1 per 1.8 ft² Sure-Weld FleeceBACK / Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -67.5 W-25. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Carlisle InsulFast with Insulation Fastening Plate 1 per 2.0 ft² Sure-Weld FleeceBACK / Flexible FAST or Flexible FAST DT (FULL) or HydroBond W-B -75.0 TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE-BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer (Note 13) Attachment Roof Cover (Note 15B) MDP (psf) Fasteners (Note 11) Density RHINOBOND SYSTEMS: W-26. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Carlisle HP-X Fastener and RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) 1 per 6 ft2 (2 x 3 ft grid pattern) Sure-Weld or Sure-Weld EXTRA induction welded to RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) with RHINOBOND tool per manufacturer’s instructions. -22.5* W-27. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Carlisle HP-X Fastener and RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) 1 per 4.0 ft² (2 x 2 ft grid pattern) Sure-Weld or Sure-Weld EXTRA induction welded to RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) with RHINOBOND tool per manufacturer’s instructions. -30.0 W-28. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Carlisle HP-X Fastener and RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) 1 per 4.0 ft² (2 x 2 ft grid pattern) Sure-Weld or Sure-Weld EXTRA induction welded to RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) with RHINOBOND tool per manufacturer’s instructions. -37.5* W-29. Min. 19/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Carlisle HP-X Fastener and RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) 1 per 6 ft2 (2 x 3 ft grid pattern) Sure-Weld or Sure-Weld EXTRA induction welded to RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) with RHINOBOND tool per manufacturer’s instructions. -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 8 of 98 TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE-BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer (Note 13) Attachment Roof Cover (Note 15B) MDP (psf) Fasteners (Note 11) Density W-30. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Carlisle HP-X Fastener and RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) 1 per 2.7 ft² (12 parts per 4x8 ft board) Sure-Weld or Sure-Weld EXTRA induction welded to RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) with RHINOBOND tool per manufacturer’s instructions. -45.0 W-31. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Carlisle HP-X Fastener and RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) 6-inch o.c. in rows 60-inch o.c. Sure-Weld or Sure-Weld EXTRA induction welded to RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) with RHINOBOND tool per manufacturer’s instructions. -60.0 W-32. Min. 19/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Carlisle HP-X Fastener and RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) 1 per 2.7 ft² (12 parts per 4x8 ft board) Sure-Weld or Sure-Weld EXTRA induction welded to RHINOBOND Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO) with RHINOBOND tool per manufacturer’s instructions. -67.5 ISOWELD INDUCTION WELDING SYSTEM: W-33. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Dekfast DF-#15-PH3 with SFS isoweld® TPO Plates (FI-P-6.8-TPO) 1 per 6 ft2 (2 x 3 ft grid pattern) Sure-Weld or Sure-Weld EXTRA induction welded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -22.5* W-34. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Dekfast DF-#15-PH3 with SFS isoweld® TPO Plates (FI-P-6.8-TPO) 1 per 4.0 ft² (2 x 2 ft grid pattern) Sure-Weld or Sure-Weld EXTRA induction welded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -30.0 W-35. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Dekfast DF-#15-PH3 with SFS isoweld® TPO Plates (FI-P-6.8-TPO) 1 per 4.0 ft² (2 x 2 ft grid pattern) Sure-Weld or Sure-Weld EXTRA induction welded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -37.5* W-36. Min. 19/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Dekfast DF-#15-PH3 with SFS isoweld® TPO Plates (FI-P-6.8-TPO) 1 per 6 ft2 (2 x 3 ft grid pattern) Sure-Weld or Sure-Weld EXTRA induction welded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -45.0* W-37. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Dekfast DF-#15-PH3 with SFS isoweld® TPO Plates (FI-P-6.8-TPO) 1 per 2.7 ft² (12 parts per 4x8 ft board) Sure-Weld or Sure-Weld EXTRA induction welded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -45.0 W-38. Min. 15/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Dekfast DF-#15-PH3 with SFS isoweld® TPO Plates (FI-P-6.8-TPO) 6-inch o.c. in rows 60-inch o.c. Sure-Weld or Sure-Weld EXTRA induction welded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -60.0 W-39. Min. 19/32-inch plywood or wood plank (Optional) One or more layers, any combination, loose laid Dekfast DF-#15-PH3 with SFS isoweld® TPO Plates (FI-P-6.8-TPO) 1 per 2.7 ft² (12 parts per 4x8 ft board) Sure-Weld or Sure-Weld EXTRA induction welded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R26 for FL14083-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 02/16/2021 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 9 of 98 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER System No. Deck (Note 1) Insulation Layer (Note 13) Roof Cover (Note 15) MDP (psf) Type Attach (Note 5) Membrane Fasteners (Note 11) Fastener Spacing Lap Width Lap Spacing Seam Weld W-40. Min. 19/32-inch CDX plywood or wood plank; 2 ft spans One or more layers, any combination Prelim. Attach Sure-Weld, min. 60-mil or Sure-Weld FleeceBACK FR Carlisle HP-X Fasteners and Piranha Plates 12-inch o.c. 5.5-inch 114.5-inch o.c. 1.5-inch outside -22.5 W-41. Min. 19/32-inch CDX plywood or wood plank; 2 ft spans One or more layers, any combination Prelim. Attach Sure-Weld, min. 60-mil or Sure-Weld FleeceBACK FR Carlisle HP-X Fasteners and Piranha Plates 6-inch o.c. 5.5-inch 114.5-inch o.c. 1.5-inch outside -45.0 W-42. Min. 19/32-inch CDX plywood or wood plank; 2-ft spans One or more layers, any combination Prelim. attach Sure-Weld, min. 60-mil Carlisle HP-XTRA Fasteners and Piranha XTRA Plates 12-inch o.c. 5.5-inch 90.5-inch o.c. 1.5-inch outside -45.0 W-43. Min. 19/32-inch CDX plywood or wood plank; 2 ft spans One or more layers, any combination Prelim. attach Sure-Weld FleeceBACK FR Carlisle HP-XTRA Fasteners and Piranha XTRA Plates 6-inch o.c. 5.5-inch 54.5-inch o.c. 1.5-inch outside -45.0 W-44. Min. 19/32-inch plywood or wood plank; 2-ft spans One or more layers, any combination Prelim. attach Sure-Weld Carlisle HP-X Fasteners and Piranha Plates or #15 Roofgrip with 2-3/8” Eyehook Seam Plates (AccuSeam) 6-inch o.c. 5.5-inch 90.5-inch o.c. 1.5-inch outside -52.5 W-45. Min. 19/32-inch plywood or wood plank; 2-ft spans One or more layers, any combination Prelim. attach Sure-Weld Carlisle HP-X Fasteners and Piranha Plates or #15 Roofgrip with 2-3/8” Eyehook Seam Plates (AccuSeam) 6-inch o.c. 5.5-inch 66.5-inch o.c. 1.5-inch outside -67.5 TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Base Sheet Fasteners (Note 11) Attach Membrane Adhesive W-46. Min. 19/32-inch plywood; 2-ft spans One or more layers, any combination Loose-laid Atlas Summit Synthetic Underlayment Carlisle #12 InsulFast and Sure-Seal Seam Fastening Plates 12-inch o.c. at the 4-inch laps and 12-inch o.c. at three, equally spaced rows in the center of the sheet. Sure-Weld SAT-TPO Self-adhered -120.0