HomeMy WebLinkAboutAPPROVED, FL14645.10-2020FL 14645.10-R4 C2397-10 10.7.2020 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Classic Rib Panel Description: 36" wide coverage with (5) 3/4" high ribs Materials: Min. 29 ga., 80 ksi steel or min. 26 ga., 50 ksi steel Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Corrosion resistant as per FBC 2020 Section 1507.4.3. Deck Description: Min. 15/32" thick plywood or min. ¾" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2020. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws at 6" o.c. (Minimum) in the field and edges. Designed as per FBC 2020. New Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Substrate (optional): Min 1" x 4" No. 2 SYP wood purlins over one layer of asphalt shingles/felt (optional) and min. 15/32" thick plywood deck fastened to supports at maximum 24" o.c. Wood purlins shall be fastened to wood rafters with (2) #9 x 3" long wood screws. The wood purlins will be spaced same as panel fastener spacing along panel length. The wood purlin, purlin to the rafter connection and rafters must be designed by others to the carry the load imposed on the panels and installed as per FBC 2020. Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 68.4 psf at fastener spacing of 24" o.c. (Factor of Safety = 2) 138.5 psf at fastener spacing of 12" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. At panel ends 3.5"-5.5"-3.5" o.c. across panel width At intermediate 9" o.c. across panel width with two fasteners at each sidelap. FL 14645.10-R4 C2397-10 10.7.2020 Page 3 of 3 Sidelap Attachment: ¼"-14 x 7/8" long SDS with washer at 12" o.c. Recommended for (Optional) roof slope less than 3:12. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) ‘Uplift Resistance of Roof Assemblies’ & UL1897-98 ‘Uplift Tests for Roof Covering Systems’ and FM 4470 Section 5.5 ‘Resistance to Foot Traffic’. Test Equivalency: The test procedures in UL 580-94 comply with test procedures prescribed in UL 580-06. The test procedures in UL 1897-98 comply with test procedures prescribed in UL 1897-12. The test procedure in FM 4470 (1992) comply with test procedure prescribed in FM 4470 (2016) Section 4.6 ‘Resistance to Foot Traffic’. Code Compliance: The product described herein has demonstrated compliance with FBC 2020 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2020 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580/UL1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T206-10, Reporting Date 4/27/10 FM 4470 Test Report ENCON Technology Inc. C1587-2, Reporting Date 5/17/08