Loading...
HomeMy WebLinkAboutPlans - Gemini - Left - ImpactMetal roofing and underlayment intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. 12" .H. 3 5/8" thick light textured stucco on typical concrete --—————————————— — — — — —— block construction _ 12 4 SLOPE 12" RIGHT ELEVATION MM. 5/8" thick x 8"W cut coral finished stucco bands SCALE: 1/4" = 1'-0- Metal roofing and underlayment intstalled per Product Approval as shown on sheet 1 over CDX decking - see roof sheeting attachment diagram on roof plan. 11 5/8" thick light textured stucco on typical concrete block construction - LEFT ELEVATION 5/8" thick X 8"W cut coral finished stucco bands Product Approval Submittal Affidavit Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows t Skgllghts Opening Type NOA/FL NUMBER Product Model # Manufacturer Glass Attachment method TEST Expiration Date Desi n Pressure 9 of Approved Tests 1,2,3 44 FLU 23`1.4 Single Hun g g SHI-7700A Impact PGT 5/1�" 1/4" dia. tapcons w/ min. 1 3/8" penetration to be spaced per product approval. Contractor shall adhere to min. edge distances specified in Product approval + �5.0/-80.0 PS A FLU 15311.1 Overhead Garage Door Model 824/811 18'-2' max. width 16'—O" max height DAB Door Compan nsta x Buck to concrete oc wit soi a cellWith (U #5 bar vert. using 3/8" x G" Hilti HLC Sleeve anchors at 8" o.c. with 1.25" dia. washers with min. 4" edge distance. Install track to buck sing (I) 5/IG" x 1 5/8" Pull thread lag screws in each bracket maintaining min. of 1.5" edge distance - GC to strictly adhere to product approval rovide 1/I4" pushrut washer on roller shafts. + B FL# 15213.1 Fiberglass Smooth Fiberglass Plast-Pro 1/4" dia. tapcon with min 1.25" embedment at 6" max from corners and 14.6" o.c. max. thereafter in jambs. C FL# 251.4 Sliding Glass Door Series 770 SGD PGT 1" nom Type "GSA" 1/4" dia. tapcons w/ min. 1 3/4" penetration to be spaced per product approval. Contractor shall adhere to min. 2 1/2" edge distances specified in Product approval + 90.0 PSF — Product NOA/FL NUMBER Model 4 Manufacturer Attachment Method TEST Expiration Date Design Pressure 9 of Approved Tests Mullions FLU 15353.8 CM-18531 vertical mullion Mi Windows and doors For CMU use (2) 1/4" x 2 3/4" tapcons with min 1 1/4" embedment penetration into each Mull Clip. Attach mull to clip using (4) 410 x 1.25" self tapping screws per clip as shown in product approval. + 118.�1 PSF _ Roof FLU 33818.2 5V Crim p Metal Roofing Gulf Coast Supply and manufacturing 26�g a. 5v crimp metal roofing attached to plywood deck using #9-15 x 1.5" HWI� wood screws with self sealing washer at 12" o.c. max spacing er System no. 5V—Type I for max pressure —94.25 psf. Install per system V type 2 for max. pressure of —131.0 psf. Fasteners shall be installed through underlay— ment and attached to/throuoh I�twood per sheeting attachment detail on roof plan. Plywood to be 19/32 CDX. Roof Zone 1/2E/2R.- — g4.25 PSF 2N/3/3E/3R: -131.0 PSF Underlay FLU 208%.1 DuPont Protec 160 Tyvek DuPont Install two layers of Tyvek horizontally in shingle style fashion using 4" and 6" overlaps. Install using 1" dia. metal or plastic cap nails at 12" o.c. along course and end laps an a single row 24" o.c. along middle line of the field I.A.W. the product approval installation instructions. Stagger top layer using 26" undercourse strip parallel to eave edge and cover with full sheet. Overlap successive sheets bg 26" I.A.W. product approval installation instructs ns. Siding stucco on Block Soffit FLU 16503.1 12" Trlpple 4 Full-O-Vent Single SPAN VINYL SOFFI Kaycan LTD Install using 2" x 4" PT battens attached to wall using 3/1C dia. with I" min, embedment into wall. Attach Soffit channel to wall using 0.097" dia. x 1.5" T-nails at 12" o.c. per detail C in P.A. Install X channel to bottom of fascia using staples into soffit and same T—nails at hem and in vallet4s tier detail A in P.A. ( roduct a royal) ± 55,6 PSF have reviewed the above and approved it by mg seal below. ( Architect or Engineer of Record ) 12 SLOPE 4 Truss mfg to provide level - return to be 1" short of wall Aluminum Drip Edge t Fascla 2" x 4" Sub -Fascia Kaycan full o vent vinyl soffit installed per product approval form on sheet I. TYPICAL SOFFIT DETAIL SCALE: 1/4" = 1'-0" 8'-1" T.O.B. 1 0'-0" = Finished Floor 1" x 4" nailer attached to level return with (2) 8d ring shank nails with min. 1.5" penetration into soffit framing NTS 2" x 4" top plated I 1/2" drywall telling on truss bottom cord 1/2" drywall on 2" x 4" studs at 1i�" o.c. 4" concrete slab with fibermesh OR 6"x6" 1*10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill base -board 2" x 4" P.T. bottom plate Interior Non-Searina fi artltlon ELEVATION NOTES: - RETURN ALL STUCCO BANDS TO WINDOW OR DOOR. nts '-I" T 2" H Metal roofing and underlayment intstalled per Product Approval as shown on sheet I over CDX decking - see roof sheeting attachment diagram on roof plan. 12 �{ SLOPS 0 n 001 1=11rell L� -O" = Finished Flo or ---- --———— — — — — — —————— — — — — — — Finish Columns with 5/8" thick light textured 5/8" thick x 8"W cut 5/8" thick cut coral stucco on typical concrete coral finished stucco bands finished stucco bands block construction REAR ELEV/470N SCALE: 1/4" = 1'-0" Metal roofing and underlayment intstalled per Product Approval as Shown on sheet I over CDX decking - See roof sheeting attachment diagram on roof plan. 12 a 4 SLOPE 12 El El 1/8" Thick cut coral stucco over paper backed wire lath nailed to substrate through one layer of 15 lb felt using 8d nails. Substrate to be 19/32" CDX Plywood nailed at C o.c. in field and edges with IOd ring shank galvanized nails into truss webbing. NEI lmllml� 5/8" thick light textured stucco on typical concrete block construction FRONT ELEVATION 12"I D.H. 5/8" thick x 8"w cut coral finished stucco bands SCALE: 1/4" = 1'-0" PERMITTING INFORMATION (FORM 100) '• 3E 2N 3R 2R 2N 2E Florida Building Code Residential: -ITH Edition and ASCE -1-16 for Wind Loading Building Design is: Enclosed Risk Category: II Wind Speed: 165 mph ultimate 3E I L 3E Mean Roof Height: 13'-8" Roof Pitch: 6:12 2N 2E 5 Internal Pressure Cow ient: ± O"I8 Subjectabilitg to damage from: Weathering: Negligible Termites: Very Heavy 3R 3E 4 Width of Roof End Zone: 4'-0" Wind Exposure Classification: C 5 Adjustment factor for Exposure Height Using Allowable Stress Design and GABLE ROOF FROM Load Combination per ASCE 1-10 Section 2.4 DL+LL: DL+0.6WL: 0.6DL+0.6WL 2:12 TO 8:12 PITCH 2R I.00 Exp Height Add Factor: x Load Combo Factor 0.6 = 0.6 applied below 1. 3 2E 2E 3 ROOF Components t Cladding Wind Pressure: Zone: 1 +271.0/-6LO psf 2R Zone: 2E/2R +2-1.0/-88.0 psf 2E I, Zone: 2N/3/3E/3R +21.0/-114.Opsf 3 L 1 L 2R L 2E 5 Components t Cladding Wall End Zone Width: 3'-0" L 3 WALL Components t Cladding Wind Pressure: Zone: 4 +36.O/-39.0 psf Zone: 5 +36.O/-48.0 psf 5 Components t Cladding Wind Pressure (NET) on Garage Door: +30.0/-34.0 psf HIP ROOF 2:12 Shear Walls Considered for Structure? Yes TO 8:12 PITCH Continuous Load Path Provided? Yes E::] = Roof Zone I Are Components an Cladding Details Provided? Yes Walls Zone 4 Minimum Soil Bearing Pressure:2,500 psi, Presumptive: X By Test: psi This Building Shall Have the Following: END ZONE EM = Roof Zone 2E/2R IMPACT PROTECTION AS NOTED IN PRODUCT APPROVAL FORM ON SHEET I Walls Zone 5 CORNER ZONE � = Roof Zones 3/3E/3R ROOF LIVE LOAD: 20 psf ROOF DEAD LOAD: 15 psf Attic w/out storage: 10 f p p g ps FLOOR LIVE LOAD: 40psf FLOOR DEAD LOAD: 10 psf Attic with storage: 2O If Roof Zone 2N ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING OCCURS BETWEEN THE BUYER AND LUYNNE BUILDING CORP. AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE Digitally signed by Daniel R. Braden Date: 2021.08.25 15:51:06-04'00' N QC O E ( N O _ N — N I N � I � Ln N I (0N� �LQ Qa-3U I u imp I UQ � U OL O � U LL � w Z w U � � w E0 - U W w IV w Ul = O O < N N O 0c)Ms r r < 1 z CA CA � ~ O �CA j U � � m � �w—x., —1 (� �(a�, LL L U to IL -t� SHEET NO: 1_ OF S. JOB NUMBER: 17-208 B c < 0.1 �oo��"'o° °boa°°�°�s�On�fC FLOOR PL,4N TYPICAL NOTES: SCALE 1/4" = i'-O" I. Contractor to verify ALL notes and dimensions prior to = Water Heater proceeding with work. 2. Contractor to STRICTLY enforce ALL OSHA Requirements. 3. ALL Lumber to be used as Beam, Rafters, etc... to have a minimum 1,400 P.S.I. fiber stress. -4. No dissimilar metals to touch. S. ALL Concrete used for slabs shall be min. 2,S00 PSI concrete. ALL Concrete used for vertical filled cells, cont. tie beams etc.. to 0 shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix m �. Drywall at ceilings shall be leveled and attached to bottom chord of trusses with screws per FBC R102.3.5. 1. ALL wood In contact with concrete shall be pressure treated. 8. ALL wall dimensions are nominal and not finished wall or stud dimensions. mil. ALL plumbing fixtures to be low flow. 10. Contractor to Provide Drain at water heater in accordance with the current edition of the Florida Plumbing Code. 11. Contractor to Provide a 2'-8" wide door at one bathroom for H Hi handicap accessibility requirements. 2%2" 2%2" 12. Lowest finished floor to be set by Governing Building Department surveyor to set in field. 13. Separation between residence and garage shall be per FBC R302,� 14. Door between garage and residence shall be 1-3/4"t 20 min. rated door 15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 pper FBC R302.9.1 1�. Wall and ceiling finishes shall have a smoke -developed index of not greater than �f50 per FBC R302.9.2 11. All exposed attic insulation materials installed on attic floors shall have a critical radiant flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation materials exposed on the underside of the roof deck or on the attic walls shall comply With F.B.C. R31� - see permit info box of code edition 18. G psum board material shall conform to ASTM C3�, C19, C41S, CSI-4, C�30, C931 C`1�O, C1002, CIO-41,CII11, C1118, C1218, C1395, or C139and shall be Installed according to the following: (FBC R102.3.5) Drywall Thickness Location Orientation Framing Member Max. spacing of fasteners Nall sizing options for installation of drywall into Spacing Nails Screws Maximum wood framing members 2" x min, thickness Ceiling Perpendicular 24 12 13ga 1 3/8" long with 19/64" head 0.098" diameter x 1 1/4" long II �2 annular -ringed or 5d cooler nail OR Walls Either 16" 8" 16" 0.080" dia. xx 1 5/8" long with Direction 15/64 head OR Gypsum board nail 0.086" dia. x 15/8" with 9/32" head. Ceiling Perpendicular 24" ill 12 13ga 1 5/8" bong with 19/64" head OR 0.098" diameter x 1 3/8" long II annular -ringed or 6d cooler nail Walls Either 16" 81, 16" 0.092" dia. xR 1 1/8" long with Direction 1/4 head OR Gypsum board nail 0.0915" dia. x 11/8" with 19/64" head. Masonry Beam I" x 6" P.T. Buck nailed to " block with case hardened nails prior to door attachment head and jambs p00 Install SGD Frame thru buck into block using tapcons as stated in product approval form on sheet 1 CR/4SH POST DET741L N.T.S. 36" high bg 4" diameter steel crash post. Floor Flange with 4 - 3/8" AREA CALCULATiONS expansion bolts Into slab (3/8"t 50 ksi steel plate) Living ABC = 1839 sq. f t. F t P h = 2� ft 2' ," 2 0 '13i8 „ 2%2" 2 0 0 Head sliding door Verify sill attachment req. with product approval on Typical Flooring sheet I. N 1 1/2„ N Bottom Track 19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.�, A108.1, A118.1, A118.3, A13�.1 and A131.1 20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall be used as backer for the wall the in tub areas and wall panels in shower areas. 21. Insulation including facings such as retarders or vapor permeable members installed within floor -ceiling assemblies, roof -ceiling assemblies, wall, craWI Spaces and attics shall have a flame spread index not to exceed 2S with an accompanging smoke developed index not to exceed -450 when tested in accordance with ASTM E 8-4 insulation shall comply with F.B.C. R31�. LU d 0 LU S chdul� Mark Size Rough Open. Window Description PRESSURE ZONE x 63%�" Single Hung ZONE 4 2, 6'-2%8"x 5'-3 %8" �5" x 63 %�" Single Hung ZONE 4 3. 2'-2" x 3'-2 1/2" 21 %2" x 38 5,/8" Single Hung ZONE 4 4. 4'-5 %" x 4'-2 %8" 54 %8" x SOTS" Single Hung ZONE 4 5. 6'-O %"x 41-2V 15 %8"x 50Y8" Single Hung ZONE 4 ALL Windows to be aluminum windows w/ tint and mullions per elevations. ALL windows to withstand pressures in permit info box on ALL windows in bathrooms to be tempered All rough opening dimensions to be verified by contractor With manufacturer S specs prior to construction sheet D oor S ch�dul� Mark Size Rough opening g p g Door Description p PRESSURE ZONE A 9'-0" X -1'-0" 108" x 84" Overhead Garage Door IMPACT RATED ZONE 4 g 3'-0" X 6'-8" 41 %"x 83%" Fiberglass Panel - Inswing RATED ZONE 4 C 5'-O" X 6'-8" 62" x 83 %2" " Sin 9 le Lite French IMPACT RATED ZONE 4 D 2'-0" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 81 %2" E 2'-6" X 6'-8" Solid Core - Wood - 6-Panel -8" Solid Core - Wood - 6-Panel - double pocket G 2'-8" x 6'-8" x 1 %" Solid Core Wood, Steel, or Masonite Door H 2'-8" X 6'-8" Solid Core - Wood - 6-Panel 2'-6" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold K 4'-O" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold L I'-6" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold ALL Exterior doors to withstand pressures stated in permit info box on sheet :4 1 GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41 All rough opening dimensions to be verified by contractor with manufacturer s specs prior to construction ron orc sq. . Rear Porch = 100 sq, ft. Garage = 311 sq. ft. Total Under Roof= 2,282 sq, ft. Total Cubic Ft = 15,581,, Install doors thru buck Into block using tapcons as stated in product appproval form on sheet I. Exterior face Buck to be Z x 6" PT of wall arles See product approval for hinge screw Into wall req. Detail at Door INSTALL VULKEM BLOCK SEALANT ON ALL JAMB, HEADER, AND SiLL BLOCK PRIOR TO BUCK INSTALLATION NTS I" x 6" P.T. Buck nailed to block with case hardened nails prior to door attachment Masonry Wall Install SGD Frame thru buck into block using tapcons as stated in product approval form on sheet I. Jamb Sliding Door D&tall At Masonry Wall NTS 1 - r2,. 2,. r' VTR � 1 3„ 4, 1 LAVJI 1 LAVJI 2" BATH MASTERSTE2" WM-I 2' AAV we-1 JiL 2" LAV-1 2" 2" Lr '��r-I KITCHEN 2, Install windows thru buck into LAUNDRY I block using tapcons as stated Exterior face in product approval form on sheet I. of wall Varies r 1"x4" P.T. Buck nailed to block with case hardened nails prior to window attachment Detail at Windows NTS Metal roofing and underlagment intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. 12 4 Truss mfg to provide level return to be I" short of wall Aluminum Drip 12" I LAV-1 1 POWDER 2 \ 2" VTR WC -I 1L , MASTER BATH #2 �„ / 2 we -I LAVJI 3 C.O. LAVw1I I 2" CONNWT TO PLUMBiN RISER PRE-ENGINEERED TRUSSES at 24"o.c. TYPICAL (shop drawings bg manufacturer) Edge >k Fascia " \R-30 blown fiberglass 2" x 4" Sub -Fascia in bottom chord of trusses 12" I/2" drywall with smooth finish Kaycan full o vent vinyl soffit installed per product approval form on sheet I. Two rows of beam block filled with concrete and (1) #5 bar cont, in each row. Substitute precast lintel filled with concrete and (1) 45 I" x 4" nailer attached to bar cont. for bottom row over openings level return with (2) 8d ring shank nails with min. 1.5" 1/2" dr wall over 1" x furringg penetration into soffit framing strips al W, O.C. with R4.1 fl—foil insulation on typical 8" Block walls 5/8" thick light textured = All dr wall to be installed per FBC R102.3.1 y stucco on typical concrete Iand shall meet all pertaining ASTM codes. "M" block construction CID Mortar to be Type only proportioned� �pper FBC R601.1 and Mortar Joints shall comply with FBC R601.2.1. Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...) 45 bar vert. w/ 30" overlap Fill cell with grout and at each filled cell (I) 45 bar vert. (typical). Max. spacing shall not exceed 48" unless otherwise noted Wood see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR L 6"x6" 410/10 WWM on 6 mil Visqueen over clean compacted termite treated fill ao Grade a. .. a �.l — ff - ail I '' — HH w4ith (2)8#5 barscrete cont.fandn#5 1481transverse bars at 48 o.c. TYPiC/4L SECTION Scale : 1/2" = 1'-0" 7,_0„ EGRESS F------- 1 1 1 I I 12'-8" _I _NI 1 MASTER 1 I BEDROOM I 8'-6" A.F_F. 12'-O" I o 00 0 DEN o 00 Covered Porch N_ 10'-8" 10'-0n,qT O Coffer Ceiling 1 I I 8'-0" to 9'-8" A.F.F. L—— — — — — —— Vaulte Ceiling GREAT 6'-0" H B. Vanity to b OD 34 %2 " hi (] o J I rr r J 18" LINEN O CABINE Ll W �D O W `r Y_ ATH W O VentDryer through wall O I d 70e �r I N 2" filler-1,I N Q A / C R-II Batts nsuiatu m I N Meter O Provide auto closer ISO Amp P nel Rod & 6, helf 4„ I I� � 0 1 r cn 'LOc E I o I� Rod t Shelf ROM 20'-.8" I N 2" x 6" knee -wall 81 -0 to 9'-8" A.F.F. below counter top I Vaulted Ceiling DiNING Y; I ROOM a it Ow — — �\! 11 (4111) 'KITCHEN ° High Wall �; — Overhang 1 -� Flat Ceiling , -- — — —— Upper cabinets to P ntrg extend over Ref. N Ref. R n pernng — — rou46J� — — y�� I E BATH ' O_ OWDER� r 1 I 22 x 54 , �\ W - LiNEN ABINE' Attic Access with light I q s I — p Rom & Shelf Steel-Bsthar� `n— See detail on this sheet q I Q — I n CLOSET Vanity to 34r2"high be o m J cn w r GARAGE 6,_4„ �4„ O 8'-4" A F F.02, Flat Ceiling (11 64 B G r----------------- i — — — — — — — — Block wall in I HE RGEN Y 1 garage to be EGRESS struck block I MT O0 1 JUNIOR o 0 1 COVERED 1 MASTER PORCH 1 1 BEDROOM 1 ® \41 -1 #2 ------ O 0 O 1 8` A.F.F. �I Coffer Ceiling 1 DWI 0011 0 0 0 91_01, 3,_5„ 2,_7„ 1 I5'-10" 5'-2" 0 o 1 1 �---12=8=---J 12 N 0 H.B. PT 717 OD 0 0 00 N Digitally signed by Daniel R. Braden Date: 2021.08.25 15:50:53-04'00' 0 Q3 a� I oNCU Q3 (y � U .0�o U Q Q U Q LL w U Z O Q � L fl N w .• Z w Op u O < N N 'b �i 6 Q- � r r L < I Z NN # Lo ~ rr� 90 6 CA (17 T_ c<1 ~ W (� . �(v U_ U �U_ N Q a-+ SHEET NO: o OF 5. JOB NUMBER: 1�-208 B Z U U U vI FCuNEDATICN FL�N STRUCTURAL_ MOTES: 1. ANY CHANGES TO THE PLANS MUST BE SUBMITTED TO THE ARCHITECT FOR APPROVAL BEFORE PROCEEDING WITH CONSTRUCTION 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL NOTATION AND DIMENSIONS PRIOR TO START OF CONSTRUCTION 3. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN PROPER ENGINEERING DATA FOR DESIGN. `�.. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS 5. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION. SLAB ON GRADE TO BE A MINIMUM 4" THICK W/ 6X6 10/10 WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL (MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH. LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY PROCTOR VALUE. 8. GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE ATTENTION OF THE ARCHITECT. 9. GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR 10. CONTACTOR TO VERIFY ALL RECESS THICKNESSES AT SHOWERS FLOOR FINISH CHANGES, SPECIALTY EQ. ETC... 45 bar vert. w/ 30" overlap Fill cell with concrete and at each filled c (1) 45 bar vert. (typical). Max, spacing shall not exceed 48" unless otherwise noted SCALE: 1/4" = 1'-0" II. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS 12. CONTRACTOR TO PROVIDE SOLID FILLED CELL AND 45 BAR VERT. AT 48" O.C. MAX. PROVIDE (1) FILLED CELL ON EACH SIDE OF OPENINGS UP TO 5'-11" WIDE. PROVIDE (2) FILLED CELLS ON EACH SIDE OF OPENINGS 6'-O" WIDE AND UP. VERIFY ALL FILLED CELL LOCATIONS WITH FOUNDATION PLAN. 13. DESIGN LOADS ARE AS FOLLOWS: SEE PERMIT INFO BOX ON SHEET I. 14. ALL REINFORCING STEEL SHALL BE GRADE 6O, MEETING ASTM A-I6, t A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL. 15. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE. FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS, SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE. 16. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTING: 3" BEAMS: 1-1/2" 11. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS. 18. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI 19. ALL STANDARD STRUCTURAL LUMBER SHALL BE SYP WITH A MINIMUM SOUTHERN YELLOW PINE 42. MIN. Fb AS FOLLOWS: 2" x 4" = Fb 1,500 PSI 2" x 10" = Fb 1,000 PSI 2" x 6"/8" = Fb 1,200 PSI 2" x 12" = Fb 915 PSI 20. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING. 21. CONTRACTOR TO PROVIDE FORM BOARD SURVEY AND FURNISH TO TRUSS MFG PRIOR TO TRUSS CONSTRUCTION FOR ACCURACY TO FIELD Termite Protection for New Construction as per F B.C. R318.1 CONTRACTOR TO REFERENCE F.B.C-R FOR FURTHER REQUIREMENTS Wood see foundation plan notes for Thicken edge to 8"x8" Base spacing at openings with concrete and 4" concrete slab with fibermesh OR one U5 bar continuous 6"x6" #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill GRADE Grade II - —IIII IIII IIII III I111- I- 14"w x 18"d Concrete footing with (2) #5 bars cont, and 3*5 transverse bars at 48" o.c. 3" � 14" TYPICAL FOOTING DETAIL J SCALE 1/2" = 1'-0" 4" concrete slab with fibermesh OR 6"x6" 910/10 WWM on 10 mil Visqueen over clean compacted termite treated fill 45 bar cont. Step per foundation plan (V 9 P 34, 1 bars cont, bottom steel ef Io" 1 12' DETAIL AT GARAGE STEPDOWN 12" x 12" concrete column block filled with concrete and (2) #­1 bars vert. tied into lintels above Top of footer 16" below finished floor 1^10 SCALE 1/2" = 1'-0" 30"x30"xl6" concrete column footing with (4) #5 bars each wag SCALE 1/2" = 1'-0" #5 bar cont, in curb 4" concrete slab with fibermesh OR 6"x6" 410/10 WWM on 10 mil Visqueen over clean compacted termite treated fill PORCH SLAB EDGE DETAIL SCALE 1/2" = 1'-0" 45 bar vert. w/ 30" overlap at each filled cell Fill cell with grout and (1) 45 bar vert. (typical). Max. spacing shall not exceed Curb height Wood 48" unless otherwise noted Verify based on see foundation plan notes for foundation plan Base spacing at openings 4" concrete slab with fibermesh OR 6 x6 1*10/10 WWM on 6 mil Visqueen over CE clean compacted termite treated fill Grade — III- � I 'llE 3lill_ II — 14"w x 18"d Concrete footing with (2) 1*5 bars cont. and 1*5 $ transverse bars at 48" o.c. 14" GARAGE CURB DETAIL I/2" Min . SCALE 1/2" = 1'-0" Edge Dist E Contractor to provide (� proper foundation chairs for proper steel installation 30" min. 2" x C PT wood secured with \ Corner Steel L. a p 1/2"dia. x 6" expansion anchors with 2" sq. washer at 18" o.c. overhead door track secured to wood n t S jamb per manufacturer's product approval Garage Door Jamb Detail GARAGE DOOR TO WITHSTAND PRESSURES STATED N T S IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL. FOOTING SCHEDULE Mark Size Description FI 14°W x 18"D MONOLITHIC FOOTING WITH 2 1*5 BARS CONTINUOUS F 12 W X 12 D MONOLITHIC FOOTING WITH (2) 45 BARS CONTINUOUS 30" x 30" x 16"D COLUMN FOOTING WITH (4) #5 BARS EACH WAY F4 8"W x 8"D THICKEN SLAB EDGE WITH 1 #5 BAR CONTINUOUS F5 14"W x 18"D MONOLITHIC FOOTING WITH 2 1*5 BARS CONTINUOUS - CURB 8 0'-0" With Curb at Garage Filled Cell Masonrg Column With One #5 From Footing To Beam Each. Filled Cell Masonrg Column With One Grout fill To Be 3000 PSI #5 From Footing To Tie Beam See Floor Plan For Location Grout fill To Be 3000 PSI Double Filled Cell Column NTS See Floor Plan For Location Eo a Single Filled Cell Column NTS N.�0YI Digitally signed by Daniel R. Braden aAe�2_Date: 2021.08.25 15:50:41-04'00' 0 Q3 111 � I oN�0 00 (D U Q Q 1_U Z Z LL W Z LLI 0 W T N cal [L AL W zw OD < ODo N NOD O L ZCA OD # CA O6 ~ CA CA O rr� LU c<1 ~ W Qj LLL U (j) N N SI-IFFY NO: 3- OF 5, JOB NUMBER: 17-208 B o ®�®%4o0 Aft 9770 °° °Rn ���� 0 Provide 45 bars with 12" min. lap into beam and 48 bar dia. into vert. filled cell Provide Cast -Crete 8U16-IB/IT precast - lintel set in mortar Min. 8" Bearing Fill lintel solid with grout. CBS WALL 45 cont. beam steel to run through lintel and tie to down rods in jamb cells. Provide PT Buck attached per jamb letails into filled ce 4" Pre -cast Sill Grout Filled Cell Provide 45 bars with 12" min. lap into footing and 48 bar dia, into vertfilled cell. Scale: 1/2" = I'—C" Verify with Plan Concrete IZ"x 12" Lintel Column Block A � Rebar Rebar 48 Bar Dia. Min. Overlap Column to Lirt&l 4ttac:hm&nt NTS BEAM SCHEDULE Mark Size and Descrl tion Two rows of beam block filled with concrete and 1 #5 bar BI continuous in each row. Hook vert. bar over top bar with 45 90' bend bar with a 10" min. lap at top bar. Additional Precast Lintel „ „ 45 bars Lintel Bar Clear A„ B „ CLEAR Length Length Span Bars Bars �r N I 1 I 1 1 1 i 1 i 1 i 2'-10" 2'-8" 1'-6" 2,u3 none 1 1 1 1 1 1 3'-4" 2'-2" 2.u3 none 8F8-OB/IT 8F8-IB/IT 8F8-IB/2T Additional 3'-10" 2` 28" 2,U3 none #5 bars CLEA : `.'r: ;•� 4'-6" 4'-4" 3'-2" 2,U3 none One Row of "H" Block Above 5'-4" 5'-2" 4'-O" 2,3 none r' N Precast Lintel r''. 4 7 none 1 Additional 1 i 2,4 none 45 bars -6" 1'-0" 6'-2" 2,U5 none 8FI6-IB/IT 8FI6-8/2T 7'-10" �'-O" none NOTES: I. min. coverage of steel=1.5" 2. min. bearing required 9 ea. end=8" ALL reinforcing steel is grade 6O. 3. standard for reinf. steel=ASTM A615 TYPICAL LINTEL SECTION ( PRECAST CONCRETE > LINTEL SCHEDULE Mark Window or Door Unit Width Lintel Size Specification Rows of "H" Block Above " 11 Bottom Steel Size Top Steel Size Max. Gravity Load (PLF) Max. Uplift Load (PLF) Max. Lateral Load (PLF) L22 2'-2" V-6" 8FI6-IB/IT ONE 1 #5 1 u5 6113 3541 2854 L31 2'-6" 2'-8" 4'-0" 8FI6-IB/IT ONE 1 #5 1 u5 2931 3019 2128 L45 4'-5" P-10" 8FI6-IB/IT ONE 1 #5 1 u5 4360 2093 946 L50 5'-0" C-6" 8FI6-IB/IT ONE 1 #5 1 #5 3480 1880 1204 L60 6'-8" 1'-6" 8FI6-IB/IT ONE 1 #5 1 #5 2661 1634 891 L80 8'-0" 9'-4" 8FI6-IB/IT ONE 1 #5 1 #5 1843 1133 139 L90 9'-0" 10'-6" 8FI6-IB/IT ONE 1 #5 1 #5 1533 914 519 L90B 9'-0" 10'-6" 8FI6-IB/IT ONE 1 #5 1 #5 1533 914 519 LI00 10'-0" 11'-4" 8FI6-IB/IT ONE 1 #5 1 #5 1366 198 604 LIOOB 10'-0" ll'-4" 8FI6-IB/IT ONE I #5 I u5 1366 198 404 L120 12'-0" 13'-4" 8FI6-IB/IT ONE 1 #5 1 #5 1015 (006 433 L120B 12'-0" 13'-4" 8FI6-IB/IT ONE 1 #5 1 #5 1015 (006 43S L140 14'-0" 15'-4" 8FI6-IB/IT ONE 1 #5 1 #5 1250 485 341 LI60 - I1' 4" - 8F8 IB/IT - ONE I # 5 I # 5 950 404 251 LI60B I6'-O" I1'-4" 8FI6-IB/IT ONE I #5 I u5 950 404 251 - ALL LINTELS SHALL BE MADE BY CAST-CRETE OR LOTTS LINTELS - LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE - REFER TO CAST-CRETE CATALOG: FOR ALL INFORMATION REGARDING: LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ. REQUIREMENTS - LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED. HIP ROOF: SHEETING ATTACHMENT DETAIL I. Minimum Nail Size = 8d angular ring shank (min. 2.5" long) 2. Minimum Screw Size = 48 x 2.5" 3. Minimum Sheathing Thickness 19/32" COX PI wood 4. Use nails or screws based on pressure for roof stated in permit info box on ones. these plans for appropraite roof 36 4 FT 1E 3� TYPICAL GABLE 2N 'it2 YPICAL_ THIP En I 3® 4 FT 2R I 0 2R 4 FT R 2N — — — 4 A% LL 4 FT I 3E 4 FT 2E 4 FT Ke Area Ede Field Fastener Max. Pressure Zone I 8d x 2.5" ring shank 45 psf Zone 2E, 2R, 2N -4" 8d x 2.5" ring shank 16 psf Zone 3E/3R 4" 8d x 2.5" ring shank 84 psf ANY ZONE �" 1*8 x 2.5" Screw 263 ps SINGLE PLY REAR GIRDER TRUSS Nail 2" x 4" blocking to vert. leg of truss with IOd x 1.5" nails at 4" o.c. Install Simpson MGT into wall usingg 5/8" dia. threaded rod set min. 12" into wet beam and (22) IOd nails into truss Ir4sm: 3LOCKING DETAIL )ER STRAPPING TER BEARINGS POINT 1/8" thick light textured stucco installed per ASTM C 92(e over ASTM O type 2 paper backed wire lath nailed to substrate through one layer of - ASTM D Type 2 felt paper using 8d nails. Substrate to be 19/32' COX Plywood nailed at 6" o.c. in field and edges with IOd ring shank nails into studs. Metal roofing and underlayment intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. \ Simpson HETA 20 or equal hurricane anchor at each truss with (10) IOd x 1 1/2" nails ( 24" o.c.) supporting Max. 1810lbs. uplift Truss mfg to provide level return to be I" short of wall Aluminum Drip Edge t Fascia 2" x 4" Sub -Fascia 12" Kagcan full o vent vinyl soffit installed per product approval form on sheet I. I" x 4" nailer attached to level return with (2) 8d ring shank nails with min. 1.5" penetration into soffit framing 12" x 12" concrete column block filled with concrete and (2) 41 bars vert. tied--' into lintels above thicken edge to 8"x8" with concrete and one 45 bar continuous BEYOND Top of footer IC below finished floor 12 F 4 Aluminum Drip Edge & Fascia Flash and Counter flash Nail ledger to gable end truss with (2) IOd ils at each web 5/8" thick stucco on 3/8" hi -rib lath attached to horizontal and vertical wood framing with nails or staples to provide no less than 1-3/4" penetration into horizontal wood framing and 3/4" penetration into vertical wood framing members 5/8" thick light textured stucco on typical concrete block construction Varies - see plan tt5 bar vert. w/ 30" overlap at each filled cell Rear Patio/Slab to be flush with bottom of sliding door recess. Step per foundation plan ---------- _ Slope per foundation plan °D 6 T — - Tubical Wood Base Trusses at 24" o.c. >e shop drawings } others ceiling transition !" 'ded using metal studs erify exact configuration es Ceding transition Insulation 2.41' Co crete Anchors Per Ma ufacturers Specs Poured Concrete or concrete block wall 1/4" Max. I I I � - Aluminum Panel I Sizes per manufacturer s v'� See Tupical Stud De p 1/r a I I ■ I Iappropriate 'Z's 7/8" x 3/32" Win washer I `v per manufacturer's .063' I � s m ._ 094" 5 I c — I I I I I ' x � — I I I Stud Detail Poured Concrete or % I Stud w/ Die Cast concrete block wall I Nickel Plated Wing I/4' Concrete Anchors Per a. Manufacturers Specs Flush Mounted Shutter Detail Brace Gable end with 2" x 4" SYP 42 8ft back nailed to bottom of top chords using (2) IOd nails at each truss PRE-ENGINEERf-D WOOI 24"o.c. TYPICAL ( shop drawings bg manufac1 " \R-30 blown fiberglass in bottom chord of trusses I/2" drywall with smooth finish Two rows of beam block filled with concrete and (1) 45 bar cont. in each row. Substitute precast lintel filled with concrete and (1) 45 bar cont. for bottom row over openings 1/2" drywall over I" x furringg strips at 16 o.c. with R4.1I-foil insulation on typical 8" Block walls All drywall to be installed per FBC R-102.3. and shall meet all pertaining ASTM codes. oo Mortar to be Type "M" only proportioned �pper and Mortar joints shall comply with FBC R2 C Provide Dur-O-Rock at all wet areas (ex. s Fill cell with Grout and (I) 45 bar vert. (typical). Max, spacing shall not exceed 48" unless otherwise noted see foundation plan notes for spacing at openings — 4" concrete slab with fibermesh OR — ROO1= PITCH AT -4:12 UNLESS OTHERWISE NOTED ON THIS SHEET L"xL" 410/10 WWM on L mil Visqueen over — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER /clean compacted termite treated fill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION. ALL TRUSS TO TRUSS CONNECTIONS BY TRUSS MANUFACTURER III— 11,. FI n at Front Porch Scale : 1/2" = I'—C" Strap truss to wall using Simpson MGT with 5/8' dia. threaded rod with min 12" embedment Into beam either wet set or in epoxy with R-30 Batts (22) IOd nails into truss. Add blocking to *ia- .a. .la*eid +1— �1a_+ Simpson HETA 20 hurricane anchor at each try ( 24" o.c.) supporting Max ""^ I uplift ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR Digitally signed by TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO Daniel R. Braden PROVIDE FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO Z2 Date:2021.08.25 TRUSS CONSTRUCTION 15:50:30-04'00' �11 Q W Z W QL N cal AL W W 0 � z w � � o ' � '\ < N N O �I �I I— L OD 00 # Z (A O ~ �WU��.�� O rr� T c<1 ~ W � Qj LLL U � �LL N 4-3 SI—IFFY NO: OF 5, JOB NUMBER.