Loading...
HomeMy WebLinkAboutNotice of Acceptance REVIEWED FORof Too", MIAMIDADE ° CODE COMPLIANCE i MIAMI-DADE , 00747 o ST® LUCIE COUNTY PRODUCTCONTROL M gr o �J � 11805 SW 26 Street, ' 08 DEPARTMENT OF REGULATORY AND ECONOMIC REG�R)-� Miami,Florida 3317 BOARD AND CODE ADMINISTRATION DIVISION i T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA). www.miamidade.2oy/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke;modify,or suspend the use of such product or materiall within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to.meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Floril a Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built-Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. d TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade(County,Florieda,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. j INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1030.01and consists of pages I through tf:o,��� The submitted documentation was reviewed by Jorge L.Acebo. ! � Vj ` NOA No.: 18-0919.07 MIAMI•DADE COUNTY Expiration(Date: 11/04/23 Approval Date: 11/08/18 Page 1 of 27 p4 Taft ROOFING SYSTEM APPROVAL 0 9a22-0000074r a 02124M a Category:. Roofing Sub-Category BUR Material: Fiberglass Deck Type• Wood ' Maximum Design Pressure: -97.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1, Test Product d Product Dimensions Specification Description GAFGLAS®Ply 4 39.37"(1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat; Tri-Ply®Ply 4 39.37"(1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat. GAFGLAS® 39.37"(1 meter) ASTM D2178 Smooth surfaced asphaltic ply sl�eet reinforced FlexP1yT'6 Wide with fiberglass mat. GAFGLAS®#75 39.37"(1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Base Sheet Wide with fiberglass mat. Tri-Ply'#75 Base 39.37"(1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Sheet Wide with fiberglass mat. i GAFGLAS®#80 39.37"(1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Ultima'Base Sheet Wide with fiberglass mat! d GAFGLAS® 39.37"(1 meter) ASTM D4897 Smooth surfaced asphaltic perforated venting base Stratavent® Wide sheet reinforced with fiberglass mat. Perforated Venting Base Sheet GAFGLAS® 39.37"(1 meter) . ASTM D4897 Smooth surfaced asphaltic nailable venting base Stratavene Nailable Wide sheet reinforced with fiberglass mat. Bottom side Venting Base Sheet surfaced with granules. Ruberoid®20 39.37"(1 meter) ' ASTM D6163 SBS polymer-modified asphalt base or Smooth Wide anchor sheet reinforced with a fiberglass mat. Ruberoid®Mop 39.37"(1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or Smooth wide anchor sheet reinforced with a polyester mat. a Ruberoid'°Mop 39.37"(1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or anchor Smooth 1.5 wide sheet reinforced with a polyester mat. Ruberoid®Mop 39.37"(1 meter) ASTM D6164 Smooth surfaced mop applied SOS base or Plus Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid® HW 25 39.37"(1 meter) ASTM D6163 Smooth surfaced torch applied SBS base or anchor Smooth wide sheet reinforced with a fiberglass!mat. d NOA No.:18-0919.07 MIAMI•DADH COUNTY Expiration Date: 11l04/23 i Approval Date: 11/08/18 Page 2 of 27 d a of Taft,,®c . PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: ; TRADE NAMES OF P ; SM-00000747 TABLE 1 a 0y= ab Test Product OP,, Product Dimensions Specification Description Ruberoid® HW 39.37"(1 meter) ASTM D6164 Smooth surfaced toich applied SBS base or anchor Smooth wide sheet reinforced with a polyester�mat. GAFGLAS® 39.37"(1 meter) ASTM D3909. Granule surfaced asphaltic cap sheet reinforced Mineral Surfaced Wide with fiberglass mat: Cap Sheet Tri-Ply®BUR 39.37"(1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Granule Cap Sheet Wide with fiberglass mat, GAFGLAS® 39.37"(1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced EnergyCap' Wide with fiberglass mat; Cap sheet is factory coated Mineral Surfaced with TOPCOAT®EnergyCote"'�lastomeric Cap Sheet Coating. Topcoat®Surface 5 or 55 gallons ASTM D6083 Solvent-based thermoplastic rubber Seal SB sealant designed tol protect and restore aged roof surfaces and to increase roof reflectivity. Topcoat® 1,5 or 55 gallons ASTM D6083 Water-based elastomenc coating Membrane Topcoat®MB Plus 5 or 55 gallons Proprietary Water based,low VOC primer designed to block asphalt bleed-through. Topcoat®FireOut"' 5 or 55 gallons Proprietary Low VOC,water Based fire barrier coating. Fire Barrier.Coating ' 1 VersaShield®Fire- 12»x 100 rolls ASTM D226 Non-asphaltic,fiberglass reinforced underlayment Resistant Roof and/or fire barrier Deck Protection VersaShield®Solo' 42"roll wide, 100 ASTM D146, Non-asphaltic,fire',resistant fib Irglass Fire-Resistant Slip ft. D828,D4869, underlayment Sheet D6757 I Topcoat® 1, 5 gallons or TAS 139 Solvent-based elastomeric sealant. F1exSeal" 1 qt.tube i i I I i i i NOA No.:18-0919.07 MIAMI•DADE COUPITY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 3 of 27 I . I ct Tarn, APPROVED INSULATIONS: °, �sa22-00000747 o4 _ TABLE 2 opt yo�Q Manufacturer Product Name Product Description with Current NOA1 EnergyGuard'Polyiso Polyisocyanurate foam insulation jGAF Insulation EnergyGuard7 Tapered Polyisocyanurate foam insulation JGAF Polyiso Insulation i EnergyGuard'Ultra Polyiso Glass-faced polyisocyanurate foam insulation ! GAF Insulation EnergyGuard7'RA Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard'RA Composite Polyisocyanurate-foam insulation with high GAF Polyiso Insulation density fiberboard or permalite EnergyGuard'RH Polyiso Polyisocyanurate foam insulation IGAF Insulation EnergyGuard'RH Tapered Polyisocyanurate foam insulation !GAF Polyiso Insulation EnergyGuard7 RN Polyiso Polyisocyanurate foam insulation GAF Insulation a EnergyGuard'Perlite Roof Perlite insulation board GAF Insulation EnergyGuard7 Perlite Recover Perlite recover board GAF Board Securock®Gypsum-Fiber Roof Gypsum board United States Gypsum Corp. Board Securock®Glass-Mat Roof Glass faced gypsum board United States Gypsum Corp. Board Structodek®High Density Fiber High density fiberboard Blue Ridgl Fiberboard,Inc. Board Roof Insulation DensDeck®Prime Roof Board Gypsum board Georgia-Pacific Gypsum LLC DensDeck®Roof Board Gypsum board Georgia-PaL ific Gypsum LLC 'i j NOA No.:18-0919.07 MiaMi•DaoE COUNTYExpiration Date: 11/04/23 Approval Date: 11/08/18 Page 4 of 27 . r i of Tap,e'oc BM-00000747 APPROVED FASTENERS: oa, OZtZ4f22 • TABLE 3 m.,e Fastener Product Product Manufacturer Number Name Description Dimensions Mih Current NOM I i 1. Drill-Tec71N#12 Fastener Phillips head,modified #12 x 8"max. GAF buttress thread,pinch point, length,#3 head.s carbon steel fastener for use Phillips � in steel or wood decks.With CR-10 coating.Available with a pinch point or drill point. 1 i 2. Drill-Tec'#14 Fastener Truss head,self-drilling, #14 z 16" GAF pinch point,high thread max.length, fastener for use in steel,wood #3 Plillips or concrete decks. head. 3. Drill-Tec"'ASAP 3S Drill-Tec''#12 Fastener with See GAF Drill-Tec'3"Standard Steel components Plate. 4. Drill-Tec''3"Steel Plate Round Galvalume®steel 3"Round GAF stress plate with reinforcing ribs and recessed for use with Drill-Tec'fasteners. 5'. Drill-Tec'°'3"Standard Steel Galvalume®coated steel 3"Round GAF Plate stress plate for use with approved Drill-Tec" fasteners. 6. Drill-Tec'AccuTrac®Flat A2-SS aluminized steel plate. 3"square; GAF Plate for use with Drill-Tec"" .017"thick fasteners. 7. Drill-Tec'AccuTrac® Galvalume®steel plate with 3"square; GAF Recessed Plate recess for use with Drill- .017"thick Tech"fasteners. 8. Drill-Tec 3 in.Ribbed Round Galvalume®plated 3"Round GAF Galvalume Plate(Flat) steel stress plate with w reinforcing ribs for use with ' Drill-Tec'fasteners. 0 r I { 1 I , NOAi No.: 18-0919.07 MIAMI•DAD;COUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 . Page 5 of 27 j " of Torn sP o7a7 o2Jti2402alz2 EVIDENCE SUBMITTED: a m m Test Agency Test Identifier Description o, Factory Mutual Research Corp. 3014547 4470 OS/22/0 3029832 4470 05/11/01 3033135 4470 11/24/08 3034312 4470 04/09/09 3036980 4470 08/14/00 3038278 4470 11/18/11 3040738 4470 a 11/16/10 3041769 4470 05/26/1.1 3042887 4470 11/14/11 3042905 4470 01/10/12 3046081 4470 I 02/13/13 3046388 4470 09/24/12 3047636 4470 08/08/13 ODOA8.AM 4470 07/09/99 OD 1 A8.AM 4470 07/29/94 OY9Q5.AM 4470 ; 04/01/98 1B9A8.AM 4470 ! .09/04/97 2B8A4.AM 4470 07/02/97 3B9Q1.AM 4470 01/08/98 3D4Q2.AM 4470 05/30/97 797-03221-267 4470 i 09/27/07 797-03825-267 4470 ; 07/21/08 797-10228-267 4470 01/23/15 UL LLC R1306 UL 790 08/21/18 PRI Construction Materials GAF-122-02-01 TAS 139 05/07/06 Technologies,LLC GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-OlRev ASTi l D6083 12/16/10 GAF-276-02-02 ASTM D226 11/15/10 GAF-306-02-01 AS IM E96 9 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-417-02-01 ASTM C1289 05/28/13 GAF-464-02-01 ASTM C1289 10/22/12 GAF-464-02-01 ASTM C1289 02/06/14' GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 ! 03/12/14 GAF-549-02-01 TAS 114 08/08/14 GAF-549-02-02 TAS 114 08/08/14 GAF-559-02-01 TAS 117(B) 09/30/14 GAF-559-02-04 ASTM D 1876 10/01/14 GAF-559-02-05 ASTM D 1876 10/15/14 GAF-559-02-06 TAS 114(M 10/02/14 GAF-559-02-07 ASTM D 903 10/02/14 GAF-559-02-08 ASTM D 903 10/02/14 NOA No.: 18-0919.07 Miarn•nAoe courmr Expiration Date: 11/04/23 Approvsal Date: 11/08/18 Page b of 27 - I of Tam, a BM-00000747 EVIDENCE SUBMITTED: (CONTINUED) { a 02►24/22 Test Agency Test Identifier Description o° 11 Pop PRI Construction Materials GAF-559-02-09 ASTM D 903 10/02/1 Technologies,LLC GAF-559-02-11 TAS 114 10/14/14 GAF-559-02-12 TAS 114 10/14/14 GAF-559-02-13 TAS 114 10/15/14 GAF-559-02-14 TAS 114 10/15/14 GAF-559702-15 TAS 114 10/15/14 GAF-559-02-16 TAS 114 10/15/14 GAF-559-02-18 TAS 114 10/15/14 GAF-559-02-19 TAS 114 04/16/15 GAF-628-02-01 ASTM C1289 05/31/16 IRT of S.Fl. 02-005 TAS 114 01/18/02 02-014 TAS 114 03/22/02 Trinity I ERD C8500SC.11.07 TAS 117 11/30/07 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 I 03/31/10 G33470.01.11 ASTM D6164 11/16/11 G34140.04.11-2 ASTM D6163 04/25/11 .1 G34140.041-4-R2 ASTM D6401 06/04/15 G34140.04.11-5-R3 ASTM D4897 06/04/15 G36780.07.11-R1 4470.=TAS 114 07/18/11 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D6164 01/07/14 G40630.01.14-2A-1-RI ASTM D6164 , 04/10/14- G43610.0.1.14 ASTM D3909 01/22/14 G6850.08.07-1 ASTM D3909 { 08/13/07 SC6870.08.14-R1 ASTM D3909 I 09/04/14 SC9700.08.15-R1 ASTM D2178 I 8/31/2015 SC10680.05.16 ASTM D6163 , 5/10/2016 SC13105.03.17-R1 ASTM D6164 3/23/2017 Dynatech Engineering Corporation #4482.02.95-1 TAS 114 09/01/95 Atlantic&Caribbean Roof 11-053 TAS 114 1 08/12/11 Consultants,LLC I i y i I NOA No.: 18-0919.07 QMIAMMIMADECOUNTY Expiration Date:. 11/04/23 Approval Date: 11/08/18 I Page 7 of 27 1 - I I of Taft, Membrane Type: BUR ; sPz2•o®raj Deck Type 1: Wood,Non-insulated 'ob°yam oc0 Deck Description: 19/32"or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c.at max.. System Type E(1): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat®FireOuf 'Fire Barrier Coating,VersaShield®Fire Resistant Roof Deck (optional) Protection,VersaShield®Solo'"'Fire-Resistant Slip Sheet installed per manufacturer's- installation instructions. Base sheet: GAFGLAS®#80 UltimaT"Base Sheet, Stratavent®Nailable Venting Base Sheet,Ruberoid® 20 Smooth, Ruberoid®SBS Heat-Weld'"Smooth or Ruberoid®SBS Heat-Weld'25 base sheet mechanically fastened to deck as described below; Fastening: GAFGLAS®Flex Ply"'6,�GAFGLAS'#75 Base Sheep,Tri-Ply®#75 Base Sheet or any of _":d Oown.#1: the above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of'9" o.c. at the 4"lap staggered and in twolrows 9"o.c. in the field. (Maximum Design Pressure—52.5 psf.See General Limitation#7) Fastening GAFGLAS®#80 Ultima"'Base Sheet,Ruberoid®20 Smooth or Ruberoid®Mop Smooth Option#2: attached to deck with approved 1%4"annular ring shank'nails and inverted 3"steel plate at a fastener.spacing of 9" o.c.at the 4"lap and in two rows'staggered with a fastener spacing of 9"o.c. in the center of the membrane. (Maximum Design Pressure—60 psf.See General Limitation#7) I Ply Sheef ;;i One or M6 of A of GAFGLAS®Ply 4,Tri-Ply®Ply 4 or GAFGLAS®#80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20401bs./sq. installed per manufacturer's installation instructions. CapSeef (Optional) One ply of GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®BUR Granule — Cap Sheet or GAFGLAS®EnergyCap''Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes;required for smooth membranes.Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq.and 3001bs./sq.respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat®Membrane or Topcoat®Surface Seal SB applied at 1 to 1.5'gal./sq. OR Topcoat®MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer)followed by Topcoat®Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options i NOA,No.: 18-0919.07 QMIAMI-DAoE COUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 21 of 27 i .a G�C1 04 Tan,,'ec WOOD DECK SYSTEM LIMITATIONS: 9P22-00000747 0 02124122 '4 1 A slip sheet is,required with GAFGLAS®Ply 4 and GAFGLAS®Flex PlyT'6 when used as a mechanica ' to apo7 60� base or anchor sheet. 2. Minimum'/4"DensDeck''Roof Board or''/Z"Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: I. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq..,or mechanically attached using the fastening pattem of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12"diameter circles,24" o.c.; or strip mopped 8"ribbons in three rows,one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation.,Encircling of the strips is not acceptable.A 6"break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached;systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official, a revised fastener spacing, prepared,signed and sealed by a Florida Registered Professional Engineer,Registered Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value - taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. i 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117.Calculations prepared,signed and sealed by a Florida registered Professional Engineer, Registered Architect,or Registered Roof Consultant(When this limitation;is specifically referred within this NOA, General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS 11 I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners).(When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. - END OF THIS ACCEPTANCE NOA No.: 18-0919.07 MIAMI-DADE COUNTY EXpiratibn Date: 11/04/23 Approval Date: 11/08/18 Page 27 of 27 Y TGFU.R1306 - ROOFING SYSTEMS FIECENED MAR 1202Z St.LUCIe 00A o Ct Aermitting i 0�° -0 d Roofing Systems See General Information for Roofing Systems 9 i GAF R1306 1 CAMPUS DR PARSIPPANY, NJ 07054 USA "RUBEROID®20 Smooth"or"RUBEROIDQ Mop Smooth"or"RUBEROID®Mop Smooth 1..5"may be utilized as an alternate to Type G2."GAFGIAS®#75 Base Sheet"or"Tri-PIye #75 Base Sheet"or"GAFGLAS®#80 Ultirna- Base Sheet"base sheets in any of the following Classifications. Torch applied"RUBEROID@ HW"SBS roofing membranes may be.used as alternates to"RUSEROIDp Mop"SBS roofing membranes in any applicable Classification as follows: A. "RUBEROID® HW Smooth" may be used as an alternate to "RUBEROID® Mop Smooth" or "RUBEROID0 Mop Smooth 1.5" B. "RUBER006 HW 25 Smooth" may be used as an alternate to "RUBEROID(g) 20 Smooth,, C. "RUBEROID® HW Granule" may be used as an alternate' to "RUBEROID® Mop Granule" D. "RUBEROID0 HW Plus Granule" may be used as an alternate to "�RUBEROID® Mop .Plus Granule" E. "Ruberoid® HW Granule FR" may be used as an alternate to "Ruberoid® Mop Granule FR" F. "RUBEROID® HW Plus Granule FR" may be used 'as an alternate tl "RUBEROIDO Mop Plus Granule FR" G. "RUBEROID @ EnergyCap HW Plus Granule FR" may be used as an alternate to "RUBERO.ID® EnergyCap Mop Plus Granule FR" ' gOOFING SYSTEMS UL Product iQ Page 2 of 4 1/2-in.thick(minimum)gypsum board or 1/4-in.thick(minimum)Georgia-Pacific Gypsum LLC"DensDecko Roofboard"or "DensDeck@ Prime Roofboard"or"DensDeck@ DuraGuardT"Roofboard"or 1/4-in.thick(minimum)United States Gypsum Co. "SECUROCK®Roof Board"(Type FRX-G)or"SECUROCK@ Glass-Mat Roof Board"(Type SGMRX)may be used in any existing noncombustible deck Classification.When this is done,the resulting roofing system Is acceptable for use over,'combustlble(IS/32-In. thick minimum) roof decks. However,the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard" or"DensDeck@ Prime Roofboard"or"DensDeck®DuraGuardT"' Roofboard"are to offset a minimum of 6-in.wiith the butt joints in the roof deck. If polystyrene is part of the'roof system,It must be placed below the overlayment board, 1/4-in.thick(minimum) "SECUROCK®Roof Board"(Type FRX-G)and"SECUROCK@ Glass-Mat Roof Board" (Type SGMRX)are Iimited;to a maximum 3:12 slope when used over a combustible deck in a system with any UL Classified Insulation except polystyrene. Multiple plies of Type Gl"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4"or"GAFGLAS@ Flex Ply 6"or"Tri-Ply®Ultra-Flexible Ply 6" may be adhered to Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard"or"DensDeck@ Prime Roofboard"or"DensDeck@ DuraGuardT" Roofboard"in hot roofing asphalt. "GAFGLAS®FlexP1yT"6 51."and"GAFGLAS@ FlexPlyT"6"may be used interchangeably in any roof covering system listed below,' "EnergyGuardTM Ultra"is an acceptable alternate to"EnergyGuardT""in any applicable Classification. "GAFGLAS®Stratavent@ Nailable Venting Base Sheet"may be mechanically fastened or fully adhered with hot roofing asphalt over noncombustible decks and as a recover over existing roof systems. , "EnergyGuardT" Perlite Insulation"may be utilized as a cover board over"EnergyGuardT""in any of the following systems. unless otherwise indicated,the roof insulation is mechanically fastened,fully adhered with hot roofing asphalt or UL Classified urethane insulation adhesive.Polystyrene referenced in any of the following Classifications include insulation. Unless otherwise indicated,all insulations may be adhered with any UL Classified Insulation Adhesive per the!rranufacturer's installation instructions(excluding %RFAdhesive 0")in any applicable Non-Combustible Roof Deck Classificahans. "EnergyGuardT"Tapered"is an acceptable alternate to"EnergyGuardT""in any applicable Classification. "EnergyGuardT"Ultra Tapered"is an acceptable alternate to"EnergyGuard'"Ultra"in any applicable Classification. "EnergyGuardT"NH Tapered"is an acceptable alternate to"EnergyGuardT"'NH"in any applicable Classification. "EnergyGuardT"NH Ultra Tapered"is an acceptable alternate to"EnergyGuardT"'NH Ultra"in any applicable Classification. 'EnergyGuardT" Barrier Tapered"is an acceptable alternate to"EnergyGuardT" Barrier". 'EnergyGuardT"NH Barrier Tapered"is an acceptable alternate to"EnergyGuardT"NH Barrier". Minimum 1-in. thick"EnergyGuardT"Barrier"is an acceptable alternate to"EnergyGuardT"Ultra"in any applicable Classification.. Minimum 1-in.thick"EnergyGuardT" NH Barrier"is an acceptable alternate to"EnergyGuardT" NH Ultra"in any applicable Classification. "Tapered EnergyGuardT"RA"may be substituted for"EnergyGuard'TM RA"in any of the systems listed below that utilize "EnergyGuardT" RA" "EnergyGuardT" RA"may be perforated on one side for use as the contact side for SUP,br modified bitumen membrane. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet("GAFGLAS@#75 Base Sheet"or"Tri-Ply@#75 Base Sheet"or"GAFGLAS®#80 Ultimal Base Sheet")is a suitable alternate for Type GI asphalt glass fiber ply sheet("GAFGLAS@.Ply'4"or"Tri-Ply@ Ply 4"or%AFGLAS@ Flex Ply 6"or"Tri-Ply(D Ultra-Flexible Ply 6")in the Gass A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet"GAFGLAS@ Stratavent@ Nailable Venting Base Sheet"or"GAFGLAS@ Stratavent@ Perforated Venting Base Sheet". Perforated,base sheets to.be loose laid or fully adhered with hot roofing asphalt and,nallable base sheets are to be mechanically fastened granule side down. As an•option Type G2 asphalt glass mat base sheet("GAFGLAS@#75 Base Sheet"or"Trl-Plyp#75 Base Sheet"or"GAFGLAS@#80 UitimaT Base Sheet"or"GAFGLAS®Stratavent(D Nallable Venting Base Sheet")may be substituted for Type G=asphalt glass-fiber ply sheet("GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4" or"GAFGLAS@ Flex Ply 6"or"Tri-Ply(D Ultra-Flexible Ply 6")as the railed base Ply in the following systems. Bottom ply or base sheet may be fully adhered with hot roofing asphalt or mechanically fastened. Unless otherwise indicated, all insulations may be fully adhered with hot roofing asphalt or mechanically fastened. "GAFGLAS®Flashing"or"RUBEROID@"may be used for flashing in any of the Class A, B or C systems Iistedi below. r ROOFINU SXS-1-EMS UL Product i I y Page 3 of 4 When"perlite"is referenced,this includes any UL.Classified perlite insulation. Crushed stones or slag are suitable alternates for gravel in any of the Class A,B or C systems listed. Structural cement fiber building units are considered suitable to be Included as a deck In the following Class A,B or C systerns listed over C-15/32 or NC. 1 The use of gypsum board under any of the following Class A,B or C systems does not adversely affect the rating.The use of 1/2-in. minimum thick gypsum board is an acceptable alternate for minimum Insulation over C-15/32 thick roof decks. The use of polystyrene Insulation board between minimum 3/4-in.thick perlite-board and deck with rosin paper(perlite/rosin paper/polystyrene/perlite)is a suitable alternate for polyisocyanurate board in the following Class A, B or C,systems. Trumbull"Perma Mop"may be utilized with any of the following"Asphalt Felt Systems with;Hot Roofing Asphalt". "GAFGLAS@*80 UltimaTM Base Sheet"may be used in any of the following systems. "GAFfEMP Perrnalite Recover Board"may be used in lieu of any perlite insulation in any of the following NC(Classifications. i Unless otherwise indicated,any of the"Asphalt Felt Systems with Hot Roofing Asphalt"may;be surfaced with"United Coatings— FireShield MB Roof Coating"applied at a rate of 2-1/2 to 3-gal/100-ft2. Class A, B and C I Hot roofing asphalt,for use with glass felts or modified bitumen membranes. Torch applied"RUBEROID®Heat Weld"SBS roofing membranes may be used as alternates to"RUBEROID " ®Mop"SBS roofing membranes in any applicable Classification. I 'RUBEROIDO HW 25 Smooth"may be used as an alternate to"RUBEROID®Mop Smooth"or"RUBEROIDe Mop Smooth 1.5". Class A 1. Deck:C-15/32 incline:3 .Barrier Board (Optional):—One or more layers rni imurn 1/4-in.-thick Georgia-Pacific Gypsum LLC "Densbeck® Roofboard"or"Densbeck® Prime Roof oard" or"DensDeck® DuraGuard Roofboard or minimum 1/4-in.thick United States Gypsum Co."SE-UROCKe Roof Board" (Type FRX-G) or"SECUROCKO Glass-Mat Roof Board"(Type SGMRX)_ i/apor Barrier(Optional):—One or more plies "GA 11 e SA Vapor Retarder":self-adhered Insulation:—One or more layers perlite or wood fibzr or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/uretha a composite or wood fiber/polyisocyanurate composite or phenolic;any thickness. Ply Sheet:—Three or more plies Type G1 "GAFGLAS0 Ply 4"or"Tri-Plye Ply 4" or"GAFGLASO Flex Ply 6" or"Tri-Plye Ultra-Flexible Ply 6",fully adhered with h of roofing asphalt Surfacing:—.Gravel. 2.Deck C-15/32 Incline: Barrier Board (Optional):—One or more layers mir imum 1/4-in.thick Georgia-Pacific Gypsum LLC "Densbeck® Roofboard"or"DensDecke Prime Roofooard" or"Densbeck® DuraGuardTM' Roofboard" or minimum 1/4-in.thick United States Gypsum Co."SECUROCK® Roof Board Glass-Mat Roof Board"(Type SGMRX). (Type FRX-Gj or"SECUROCKe Insulation:—One or more layers perlite or wood fiber or glass fiber or Poly'iso anurate or urethane or perlite/polyisocyanurate composite or perlite/urethar ie or phenolic,any thickness. composite or wood fiber/polyisocyanurate composite i Ply Sheet:--Three or more plies Type G1 "GAFGLAS e Ply 4"or"Tri-Ply® Ply 4"or"GAFGLAS® Flex Ply 6" or"Tri-Plye Ultra-Flexible Ply 6",fully adhered with h t roofing asphalt. littps://iq.ulprospector.con-1/en/profile?e=148955 2/13/2019 I. d ��UUr1NCi SY s`l i;vla.� UL Product 1q Page 4 of 4 1..y i Cap Sheet:---Type G3 "GAFGLAS® Mineral Surfai ed Cap Sheet" or"Tri-Ply® BUR Granule Cap Sheet'° or "GAFGLAS® EnergyCapTm Mineral-Surfaced Cap SI eet",fully adhered with hot roofing asphalt. 3. Deck:NC Inclin :2 j Barrier Board(optional):—One or more layers. ninimum 1/4-in.thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or"DensDeck® Prime R ofboard"or"DensDeck® DuraGuard-�Roofboard" or minimum 1/4-in.thick United States Gypsum Co." ECUROCK®. Roof Board" (Type FRX-G)',or"SECUROCKqD Glass-Mat Roof Board"(Type SGMM. i Insulation (optional):—One or more layers per,{to or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite di perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,2-i .maximum. i Ply Sheet:—Two or more plies Type G1 "GAFG : S® Ply 4"or"Tri-PlyD Ply 4" or"GAFGL�S® Flex Ply 6"or "Tri-Ply® Ultra-Flexible Ply 6",fully adhered with 1,of roofing asphalt. Cap Sheet:—Type G3"GAFGLASO Mineral SurFa A Cap Sheet"or"Tri-PlydD BUR Granule Cap Sheet" or "GAFGLASO EnergyCapTM Mineral-Surfaced Cap S!ieet",fully adhered with hot roofing asphalt. NV 4.Deck:C-15/32 i Incline:1 —SUpShee4- O tionai :--Red rosin paper,nailed'to deck. -- atkwi--(Optional):—Any thickness perlite or wood fiber or glass fiber or;polyisocyanurate mechanically fastened or adhered with OMG Inc."Ol Bond Fastening System"or any UL Classified insulation adhesive. Base Sheet:l One ply Type G2"GAFGLASO#75 Base Sheet"or"Tri-Ply® #75 Base Sheet' or"GAFGLASO 080 Ultima"" Base Sheet" or"GAFGLAS® Stratavent® Nailable Venting Base Sheet", mechanically fastened. Ply Sheet:—One or more elies T e G1 "GAFGLASR PI 4"or"Tri-Ply® Ply 4" or GAFGLASO Flex Ply 6"or °Tri-Ply® Ultra-Flexible Ply 6",fully adhered with hot roofing asphalt. Cap Sheet:—Type G3"GAFGLASO Mineral Surfaced Cap Sheet"Pr"Tri-Plyo BUR Granule;Cap Sheet" or "GAFGLASO EnergyCap— Mineral-Surfaced Cap Sheet",fully adhered with hot,roofing asphalt. .Coalhig(Opti®naq:—"United Coatings-TOPCOAT® EnergyCot6l Roof Coating" or"TOPCOAT® MB Plus Coating" or"United CoatingsTm Roof Mate MB Plus Coating"applied at a rate of 2-gal./100-ft.z. i i I d , { i i https://iq.ulprospector.com/mVpro file?e=148955 2/13/2019 I , i