Loading...
HomeMy WebLinkAboutNotice of Acceptance { a REVIEWED FOR FILE COPY �++ CODE COMPLIANCE z� ST. LUCIE CO TV D�9/�� i MIAMI-DADE COUNTY MIAMI• ! I BOC PRODUCT CONTROL SECTION �� qJilZ 1 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION TI(786)315-2590 F(7 99 86)315-25 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy ICP Adhesives and Sealants,Inc. 12505 NW 441"Street 1 " Coral Springs,FL.33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of jconstruction materials..The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority,Having Jurisdiction(AHJ). . t stated below. The Miami-Dade C oun Product Control Section I.This NOA shall not be valid after.the expirationda e s ,ty reserve the right to have this product (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) p r material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the o p q tY p� p p revoke modify, or suspend the use manufacturer will'incur the expense of such testing and the AHJ may immediately ,� fy, p of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. I DESCRIPTION: ICP Adhesives Polyset®AH-160 LABELING: Each unit shall bear.a permanent.label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise'noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed a;d there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been!a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. j ADVERTISEMENT: The NOA number preceded by the words Miami=Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire,NOA shall be provided to the user by the manuf 1 cturer or its distributors and shall be available'for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 htiartuDaoecout�rr Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 d J ROOFING COMPONENT APPROVAL:' Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset®AH-160 as manufactured by ICP Adhesives and Sealants,Inc. as described in this Notice of Acceptance.For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset®AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A TAS 101 -.Two component polyurethane foam adhesive Polyset®AH-160 ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPacV N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset®AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX. PHYSICAL PROPERTIES: Pro a Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40'F.,2 weeks +6.0%Volume Change @158°F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 M�Aht�•�e COUNTY NOA Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 i EVIDENCE SUBMITTED: Test Agency Test Identifier ,. Test Name/Report 1 Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS.101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ' ASTM D 1623 02/01/94 Polymers Division d Ramtech Laboratories,Inc: 9637-92 ASTM E 10& 04/30/93 i Southwest Research Institute 01-6743-011 ASTM E 108 .11/16/94 01-6739-062b[l] ASTM E 84 .01/16/95 Trinity Engineering. 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 1101 I 02/21/12 TAS 123 9 Celotex Corp.Testing Services 528454-2-1 -TAS 101 10/23/98, 528454-9-1 { 528454-10-1 J 520109=1 . TAS 101 1 12/28/98 520109-2 520109-3 520109-6 j 520109-7 J 520191-1 TAS 10.1 I 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset®AH-160 shall solely be used with flat,low, &high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofmg Application Standai d RAS 120.. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset®AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 1 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. i . 9 NOA No.: 17-0322.03 MIAMIOADECOUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset®AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset®AH-160. 2. ICP Adhesives Polyset®AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset®AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and Sealants, hie. ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required-before application' of any adhesive. The mix ratio between the "A" component and the"B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack®30& 100 dispensing equipment only. 7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset®AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 MI�I•oane couNrY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 • I • I I I. Table 1:Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Area Weight Minimum Paddy Contact , Minimum Paddy Gram Eave Course-Flat,Low,High AllEave Course 17-23 s inches 45-65 Profiles q� Flat,Low;High Profiles #1 17-23 sq-inches 45-65- Flat Profile 42 10-12 sq.,inches 30 Low Profile #2 12-14 sq.:inches 30 High Profile #2 17-19 sq., inches 30 Flat,Low,High Profiles 43 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq.inches ai overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead I Two Piece Barrel(Pan Tile) Two Piece 65-70 sq, inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the . I manufacturer's name or logo,and following statement. Miami-Dade County Product Control Approved" or the Miami- Dade g tY pP Dade County Product Control Seal as shown below. vt"i = COUNTY BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. 1 V - 322 NOA No.: 17 03 MIAMI•DADE COUNWM Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 I ADHESIVE PLACEMENT DETAIL# 1 vNO plastic Paddy(Banomfir") Flat/Low Profile Tile urntrflsyfni"t 41 1. Starting at the eave course, apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm) foam paddy onto the underlayment positioned as shown, r'f under the strengthening rib closest to the overlock '\ 1a t of the tile being set. Eaveeourseti 2. Continue in same manner.Insure approximately 17 °t n (109.7 cm2)—23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2 yn,i > Eatio Cluyur" a Nall throughplast'rccement Medium Profile/ Double Pan Tile {when reQsilred) 1. Starting at the eave course, apply a minimum 2" (50.8'mm)x 10" (254 mm)x 1"(25.4 mm) foam paddy onto the underlayment positioned as shown 1 under the pan portion of the tile closest to the " t J overlock of the tile being set. 20iramwld�'� " 2. Continue in same manner:Insure approximately 17 Battens op4lo"al ( :- r �, (109.7 cm2)—23 (148.4 cm2) square inch adhesive ,, 4 contact with the underside of the tile. 6-7 101" Live closure EaticCoursic f r -• .Fascia —kil tlroush PLsstle torr,a"a High Profile/Single Pan Tile ;m4imrrequlredl f f p ddy1BanK+ahTilel g g 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10" (254 mm)x 1"(25.4 mm) foam paddy onto the underlayment positioned as shown toz".X under the pan portion of the the closest to the 2 in. wlda " ' `` overlock of the tile being set. Battens ` 2. Continue in same manner.Insure approximately 17 °po°"a' V"ZN (109.7 cm')—23 (148.4 cm') square inch adhesive contact with the underside of the tile. s EasV course'` i 1 y Weephole Eave ctosure NOA No.: 17-0322.03 Mh4MI-DADE COuN7Y Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 lUUAaUUSbLLUUUUUU , I � ADHESIVE PLACEMENT DETAIL#2 I W1,through pUslic'mmMnt Paddy(8*nr*1hTFl4) Flat/Low Profile'Tile *ben required) Umdothymant 1. Starting at the eave course apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"r(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of '\ in. �'1 = the tile being set.Insure approximately 17 (109.7 cmZ) 23 (148.4 cmZ) square inch adhesive contact with the Buttaes optional / >3vac4u/. =' . underside of the tile. 2. At the second course a � 50.8mm pPlY a minimum 2"( ) Fasaa x 7" (177.8 mm)x 1"(25.4 mm)foam paddy.onto the. ' underlayment positioned as shown under the strengthening rib closest to the overlock of the tile FWM Close being set. 3. Continue in same manner.Insure approximately 10" (64.5 cmZ)- 12 (77.4 cmZ) square inch adhesive contact with the underside of the tile. Medium Profile/Double Pan Tile Nail through plastic cement (when required) ��.Paddy i0eneathTile) 1. Starting at the eave course, apply a minimum 2"(50.8 mm)x 1.0"(254 mm)x 1"i(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to.the overlock of the .q � tile being set;Insure approximately 17 (109.7 cmZ)— ''"` �' 23 (148.4 crnz) square inch adhesive contact with the underside of the tile. Battensoptionat ,� .' r CO 2. At the second course,apply a minimum 2"(50:8mm) x 7" (177.8 rim)x 1" (25.,4 mm) foam paddy onto the- FA"M%Uf* underlayment positioned L shown under the pan Eyya canrRr portion of the tile closest to the overlock of the tile F.� being set. 3. Continue in same manner,Insure approximately 12" (77.4 cm2)- 14(90.3 cmZ)square inch adhesive contact with the underside of the tile. I I (Instructions continued on nextpage) { NOA No.: 17-0321.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 9 • If you're having_trouble making your payment,please contact us. We're glad to have you as our customer Your home matters and we look forward to continually providing the information and resources you need.To make the most of your Wells Fargo customer relationship go to:wellsfargo.com/mortgage/welcome. _ Sincerely, J.R. Russell Senior Vice President Wells Fargo Home Mortgage The Servicemembers Civil Relief Act(SCRA) may offer protection or relief to members of the military, their spouses, partners, and dependents. If you have been called to active duty,.or are the spouse,partner in civil union,domestic partner, or financial dependent of a person who has been called to active duty, and you haven't yet made us aware of your status,please contact us as indicated below: 0 • Wells Fargo Home Mortgage military customer: Call 1-866-936-SCRA(1-866-936-7272) or fax your Active Duty Orders to IL-877-658-4585, attention SCRA. o A In addition, please be aware that prior to seeking a refinance of your existing mortgage loan,you should co consult with your legal advisor regarding the potential loss of any benefits you are entitled to under the z Servicemembers Civil Relief Act or applicable state law. z z z Fee schedule z Fees for assumptions,partial releases,and other services will be quoted upon request.Allowable fees for checks and drafts that are not honored z by your bank vary by state and will be assessed automatically.States with fixed fees are as follows:KS-$3o;PA-$50;ID-$20;CO,NC&OK-$25; z HI,IA,&MN-$3o;SD-$40.Fees are subject to change without notice. z 0 0 N Wells Fargo Home Mortgage is a division of Wells Fargo Bank,N.A.©2017 Wells Fargo Bank,N.A.All rights reserved.NMLSR ID 399801 0 0 au V N O m m N 4, d I ADHESIVE PLACEMENT DETAIL#2(CONTINUED) Nall ftouOl Owk a faddy tB"WA t+Titat High Profile/Single Pan Tilel (»than wqu et� aar�n+ni 1. Starting at the;eave course, apply a minimum 2"(50.8 1 C nm)x 10"(254 mm)x 1"(25.4 mm)foam paddy ,Y onto the underlayment positioned as:shown under the pan porCiori of the file closest to the overlook of the the being set.Insure approximately 17(109.7 cnzZ)— 7 23 (148.4 cmZ)square inchl adhesive contactwith the tieens a�tiaml s underside of the tile. 2. At the second course,apply a minimum 2"(50 8mm) Y.: azda x 7"(177.8 min)x 1"(25.4 mm) foampaddy onto the } ` 1�aaib#k• underlayment positioned as shown under the pa n° to ,; 2 kL portion of the;tile closest to the.overlock of the the oa�ce being set. 3. Continue in same manner.Insure approximately 17" (109.7 cm2) - 19(122.6 cm 2)square inch adhesive contact with the underside lof the tile. i MIAMM >_COUNTY. NOA No.1�032Z 03 APPROVE Expiration Aate: 0�/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL#3 Nail through plastic cement paddy cbetween tiles) twhenrequired) 1. On the eave course only, apply a minimum 2" (50.8 Battens optional ° mm)x 10"1(254 mm)x 1" (25.4 mm)foam paddy ° Paddy(under tile) onto the underlayment positioned as shown,under Singlepaddy the strengthening rib for flat tile or under the pan on top of the i 1 portion of the tile for low or high profile tile closest ` to the overlock of the tile being set.Leave r.: 4x4in. single pad ,Ga+�'-, approximately 4" (101.6 mm)up from the eave sin lepaddy un erN �`�= edge free of foam to prevent the expanded adhesive on wrderta t ` i� z x a in, �' from blocking the weep;holes. Insure °t approximately 17-23 in2 (109.7-148.4 cm)of adhesive contact with the underside of the tile loinin. fascia Save Closure 2. Apply a 4",(101.6 mm);x 4" (101.6 mm)x 1" (25.4 mm)foami,paddy onto the underlayment just below Hat/Low Profile Tile the second course line positioned foam paddy under the strengthening rib for flat tile, or under the Nag through plastic cement Single paddy under.tile pan portion of the tile, closest to the underlock for (when required) Paddy cbetweentiles) the second,course tile to be installed. Insure approximately 8-9 in'(51.6-58.1 cmZ) of adhesive Battens Paddy(under tile) contact with the underside of the tile. Optional a -� v f shwfie (Instructions continued on next page) r" on top of tile r4x41n. 2x41n uunndggerhyym ent n " -s to in ' 2in. f� Eave Closure EaveCourse Fascia I' Medium ProflleTile i i r f i NOA No.: 17-0322.03 MtaMt•DADE COUNTY 1 Expiration Date: 05/10/22 Approval Date: 04/27/17 . - .__._..._ _ .... -- _., ......._. ._. .w..; ._ -- Page.9.of 1.1-- - Xr meriHome mortgage PO Box 77404 Ewing NJ 08628 + 0840327 000010933 09SP02 00064001 OE Maria Del Pilar Mora Francisco Ulloa 1368 NW 129th Way Sunrise FL 33323 —m =o - =m —m �Y F ADHESIVE PLACEMENT'DETAIL#`3:(CONTINUED) ImlitnK660PUS& -4epa underWo :. . t+•h��eyutre 3. Also a 1 j;a 2" 50.8 mm .x 4". 101.6 mm x W 1�(bPttree�tliesi PP Y, . ( � ) , (,. ) : . ,.: ..( 19 mm ad the a ve p dy on top of a course file , easea�s Pbd�tuadvtUei surface as shown,on tc :of the strengthening rib °4"O7A for flat tile{!or on top of a pan portion of the tile,v closest to the underlock11of.ttie first course of tile. � Install second course of file Insure approximately _ 9(58,1 cn?):-:11 (71cm2)square"inch adhesive * contact with the underside of the the at the overlap �2:aln and.7.(45.2 cmz)-9(58.1.cm?)square inch adhesive contact with the underside of the tile.at ,, . the head of the tile:.Coiitiniie in same manner Evecourse yob, 2tn Eaneao ,re D"Ped1 . ....:...:. i i i u ,I I MIAMI-DMECOUNTY N M No 1'7 032 03 :. E.spiratlon Date; 05/IQ122 A r""oval Date:04727/17 Page 10 of 11 r J ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL I Two Piece Barrel(Cap and Pan)Tile 1. Starting at the eave course, apply a minimum 2" 7i Place enough.adhesiveto achieve.56.to.70sgan. Stere0pitch'applicatl6ns. „ ee in contact with the pan.tile. (whenrequked). (50.8 mm)X 10 (254imm)X 1 (25.4 mm)foam 2jTurn;coveisupside.down.Place adhesive in' paddy onto the underlayment positioned as to in.from outside edge:of cover tile. shown under two adjacent pan tiles. Support eave Then install thetile:Eri3ure 20 fo. 25.sgan:contagarea. tiles from rocking until adhesive has a chance to ;. cure. Underlayment 2. Continue in same mariner bringing two pan . courses up toward the ridge. Insure approximately 65 (419.4 cmz)—70 (451.6 cmZ) square inch adhesive contact with the underside Sheathing of the pan tile. y tf s Eave closure cv' (motarshown) 3. Turn covers upside down exposing the underside weephole of the tile.Apply a minimum 1"(25.4 mm)x 10" Fascia Board (254 mm)bead of adhesive directly on the inner Remove too liortionoftheeave course cover'tile.Atiuttosecond course of edge of each side of the cover tile. Leave pan tiles Ensure eave end of pan and cover tiles are flush-at eave line.. „ „ approximately 3/4 (19 mm)to 1 (25.4 mm) Two Piece.:Barrel-High Profile Tile from the outside edge of the tile,inward,free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course.Insure a minimum of 20 (129 cmz) -25 (161.3 cmZ) square inch contact area on each side of the cover tile to the pan tile.,Continue in same manner. Trim away any cured exposed foam adhesive.Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required,2"(50.8 mm)x 4"(101.6 mm)nailers or the tie wire system using galvanized, stainless steel,or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE 1 I I NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 r ? Approval Date: 04/27/17 j Page 11 of 11 I ]q 3