HomeMy WebLinkAboutNotice of AcceptanceENGINEER
File C®py
EVALUATE
TEST
NEMO I etC.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
CONSULT
Deerfield Beach, FL 33442 Date of Issuance: 12/21/2020
(954)233-1330
SCOPE: ,
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code,. Residential Volume. The products
described herein have been evaluated for compliance with the 71h Edition (2020) Florida' Building Code sections noted
herein.
DESCRIPTION Polyglass Roof Underlaymerits, for use m FBC NVHZ�urIs,- idlohs
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1. j
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named pro,duct(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to'the product(s) change. Acceptance of
our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report
relative to updated Code requirements with each Code Cycle. j
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Jett. Evaluated" may be displayed
in advertising literature. If any portion of the Evaluatio Report is displayed, then it shall be done in -its entirety. INSPECTION:! Upon request, a copy of this entire Ev; Ilion Report shall be provided to the user by the manufacturer Ir its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by:
_ 07
Robert J.M. Nieminen P.E.�'c' `' �'` The facsimileseal
� �.�e```:.;_.:••-.-r appealing was authorized by Robert Nieminen, P.E.
Florida Registration No. 59156, Florida DCA ANE1983 ; ' on 12/21/2020. This does not serve as an electronicallysi�ned
document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it'evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
©2019 NEMO ETC, LLC
NEi%PIO etC.
ROOFING COMPONENT EVALUATION:
~
�✓;'Vry
4Fr%S�-i..: "'_`lv.�'�. +:'f 2
i3.,. r _ S_'`i.,3ai!'��-:+r'La. a:�
'?d�`.�_i�
��i y" _ 5.' f'i%r-:-.�i- - _ �-`� V'^s77'F%� sys "T^�^C
Product Category:,
Roofing
Sub -Category:
Underlayment
Compliance Statement:
Roof Underlayments, as produced
by Polyglass USA,
Inc., have demonstrated compliance with the
following sections of the
7t' Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the
Installation Requirements and Limitations / Conditions
of Use set forth herein.
r,ME
=11r
„x
,
Section
-Property
StandardYear
RAS 115, TAS 110
Material standard
ASTM D226
2009
TAS 110
Material standard
ASTM D1970
2015
TAS 110
Material standard
TAS 103
2020
TAS 110
Material standard
ASTM D6163
2015
TAS 110
Material standard
ASTM D6164
2011
TAS 110
Material standard
ASTM D6222
2011
TAS 110 .
Accelerated Weathering
ASTM D4798
2011
Entity
Examination
Reference
Date
Entity
Examination
Reference
Date
FRO (TST 6049)
TA5114(J)
11757.08.01-1
9/13/2001
NEMO (TST 6049)
ASTM D1970
4-PLYG-18-004.03.18
3/29/2018
ERD (TS1 6049)
. TAS 114(C)
P1740.01.07
1/4/2007
NEMO (TST 6049)
. ASTM D1623, TAS 103
4S-ICP-18-001.07.18-R1
7/23/2018
FRD (TS F 6049)
ASTM D1623, TAS 103
P11030.11.09-1
11/30/2009
NEMO (TST 6049)
A5TM D6163
4S-PLYG-18-002.01.19-A
1/24/2019
ERD (IST 604g)
TAS 117(8) / TAS 114(C)
P11030.11.09-2
11/30/2009
NEMO (TST 6649)
ASTM D6222
4S-PLYG-18-002.05.19-C
5/20/2019
EP.D.(TSf 6049)
ASTM D4977/TAS 103
P13030.11-09.3
11/30/2009
NEMO (TST 6049)
TAS 103
4S-PLYG-18-004.10.19-G
10/8/2019
ERD (rS r 60;t9)
ASTM D1970, D4798
P37300 10.11
10/19/2011
NEW (TST 6049)
TAS 103
4S-PLYG-18-004.10.19-1
10/8/2019
FRO (rST6049)
TAS 103
P40390.03 12-1
8/6/2012
NEN10 (TST 6049)
TAS 103
45-PLYG-18-004.10.19-L
10/9/2019
FP.O (1Sf 60:7)
ASTM D1623, TAS 103
P40390 09.12-2
8/7/2012
NEMO (TST 6049)
TAS 103
4S-PLYG-18-004.12.19-F
12/18/2019
ERD (TST 60.19)
ASTM D1623, TAS 103
C41420.09.12-3
9/11/2012
PIE M0 (TST 6049)
TAS 103
4j-PLYG-I9-SSUDL-02.A
1/2/2020
ERD (TST 6049)
ASTM D6509 I
P37590.03.13-1-R1
2/5/2013
N E M 0 (TST 6049)
A5TNI D1970. D4 pI93
45-PLYG-18-004.01.20.H
1/14/2020
ERD ( TST 6049)
TAS 114(1) I
P39680.03.13
3/4/ 2013
NEN10 (TST 6049)
ASTiM Di970, D4Y98
4S-PLYG-18-004.01.20.K
1/14/2020
FRO (rsr 6049)
A5TM D6164
P37590.03.13-3A
3/6/2013
NEMO (TST 6049)
TAS 103 (tile slippage)
4S-PLYG-18-004.01.20.A
1/16/2020
FRO (TST 6049)
ASTM D6164
P37590.07.13-1
7/2/2013
NEMO (TST 6049)
ASTib1 D6164
45-PLYG-18.004.01_20 B
1/16/2020
ERD (TST 60-'9)
ASTNI D4601
P45940.09.13
9/4/2013
NEMO (TST 5049)
TA5 103
PLYG-SC15855.10S.20.A
5/29/2020
ERD (TST 60!'J)
ASTM D1623, TAS 103
P45270.05.14
5/12/2014
NEMO (TST 6049)
TA5 103
4j-PLYG-20-5SUDL-01
7/6/2020
ERD (rsr 6049)
ASTM D1623, TAS 103
6020.09.14-6
9/8/2014
NEMO (TST 6049)
ASTM D6222
4q-PLYG-I9-SSMBB-0S.A
7/23/2020
ERD (TST 60-19)
TAS 103
P44360.10.14-R1
10/7/2014
NEN10 (TST 6049)
ASTM D4798, D1623
4j-PLYG-I9-SSU0L-05.A
9/10/2020
FRO (rST 5049)
ASTM D1970, D4798
P43290.10.14
10/17/2014
NEMO (TST 6049)
ASTM D1970
41-PLYG-20-SSUDL-OS.A
9/30/2020
FRD (TST 5049)
TAS 114(J)
P39680.03.13
3/4/2013
NEMO (TST 6049)
TAS 103
41-PLYG-20-SSUDL-05.0
9/30/2020
ERD (TST
A5TM D1970, D4798
PLYG-SC10130.06.15-1
6/27/2016
NEMO (TST 6049)
TAS 103
4j-PLYG-20-SSUDL-11.A
10/21/2020
FRO (TST 6049)
ASTM D1623, TAS 103
PLYG-SC1o130.06.16-2
6/27/2016
NEMO (TST 6049)
ASTM D1970, D4798
45-PLYG-18-004.12.19.D
10/27/2020
I
ERD (TST 6049)
TAS 103
PLYG-SC10130.06.16-3
6/27/2016
NEMO (TST 6049)
ASTM D1623ITAS 103
4p4CP-20-5SLAP-01.A
12/15/2020
FRO (TST 60-'9)
TAS 103 (,tile slippage_)
PLYG-SC13040.12.16
12/27/2016
UL (QUA9625)
Quality Control
Service Confirmation (FL)
09/13/2018
ERD (TST 6049)
TAS 103 (tile slippage)
PLYG-SC12115.08.17
8/8/2017
UL (QUA9625)
Quality Control
Service Confirmation (TX)
11/07/2019
ERD (TST 6049)
TAS 103
PLYG-SC13035.08.17
10/31/2017
UL (QUA9625)
Quality Control
Florida OCIS
Current
NEM-3 ETC, LLC. Evaluation Report3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7 " EDMO`d (2020) FBC HVH2 EVALUATIO`i FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 2 of 11
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
.9
0
5.2
5.3
5.4
Product Material Standard Plant(a) i DescHo ion
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester-reinforced;SBS modified1bitumen
base sheet
Elastoflex 56 G
ASTM D6164
FL, PA
Polyester -reinforced; SBS modfied]bitumen
cap sheet
Ta51n� /nart,an
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS Inodified1bitumen
cap sheet
TAS 103 (partial)
Polyflex G
ASTM D6222
FL
Polyester -reinforced; APP modified bitumen cap sheet
TAS 103 (partial)
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced; APP modified bitumen cap sheet
�
TAS 103 (partial)
I
J
Polyflex SA P
ASTM D6222
FL, TX
Polyester -reinforced;' APP modified bitumen cap sheet
TAS 103 (partial)
j
Polyflex SA P FR
ASTM D6222
FL, TX
Polyester -reinforced; APP modified bitumen cap sheet
TAS 103 (partial)
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate surface
Polystick us
ASTM D1970
FL, NV, PA,
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
TX
membrane, glass fiber reinforced, surfaced with poly -film
surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
membrane with a 190 g/mllpolyester fabric surface
Polystick TU P
TAS 103
FL, PA, TX
Nominal 130-mil thick rubberized 'asphalt waterproofing
membrane, glass-fiber/polyest r reinforced, with a granular
surface
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
ASTM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced,jsurfaced with a textured
film surface
This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, i6 any way, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for.permitting or design guidance
unless retained specifically for that purpose.
This Evaluation Report is not for use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami -
Dade Counties).
This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction. it
This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam
plastic insulation.
� II
NEPAO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7 " EDITION (2020) FBC HVHZ EVALUATION FL5259-P.32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 3 of 11
i
I
yi;^ V�3t
NEI✓10 retC.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
r
TABLE 1: ROOF COVER OPTIONS
FBC Section:
TAS 110(510),
TAS 110(S21),
RAS 133
TAS 110(511)
RAS 130
RAS 115
RAS 118,119 & 120
Underlayment
Asphalt
Clay and Concrete Tile
Metal
Slate or Slate-
Wood
Mechanical Attach
Adhesive -Set
Shingles
Type Shingles
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase
(Alternate to
(as Base Sheet,
(as Base Sheet,
(Alternate to
(Alternate to
(Alternate to
D226, Type II)
See 5.8)
See 5.8)
D226, Type II)
D226, Type II)
D226, Type II)
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase P
(Alternate to
(as Base Sheet,
(as Base Sheet,
(Alternate to
(Alternate to
(Alternate to
D226, Type II)
See 5.8)
See 5.8)
D226, Type II)
0226, Type II)
D226, Type II)
Elastoflex S6 G
No
Yes
Yes
No
No
No
(See 5.6.1)
Elastoflex S6 G FIR
No
Yes
No
No
No
No
Polyflex G
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex G FR
No
Yes
No
No
No
No
Polyflex SA P
No
Yes
Yes
No
No
No
(See 5.6.1)
j Pol flex SA P
No
Yes
No
No
No
No
Polystick IR-Le
Yes
No
No
No
Yes
Yes
Polystick PATS Plus I
Yes I
Yes
No
Yes
Yes
Yes
Polystick TU Max
No
yes `
Yes
Yes
No
Yes
Polystick TU P I
No
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Polystick TU Plus
Yes
i
(Sze 5.6.1)
Polystick XFR I
Yes
Yes I
No
Yes
Yes I
Yes
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE
COMBINATIONS'
Underlayment
Adhesive
Florida Product
Approval
Polystick TU Max or Polystick TU Plus
DAP Foam "Touch 'n Seal
NOA 20-0309.05
StormBond Roof Tile Adhesive"
Polystick TU Max or Polystick TU Plus
Dupont "Tile Bond- Roof Tile
Adhesive" Adhesive"
Elastoflex S6 G, Polyflex G, Polyflex SA P, Polystick TU Max or Polystick TU
ICP Adhesives and Sealants
Plus
"Polyset' AH-160"
NOA 17-0322.03
Polystick TU Max or Polystick TU Plus
ICP Adhesives and Sealants
"Polyset'
NOA 18 0131.02
RTA-1"
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Appr vol for Overturning Moment Resistance Performance
i EN10 ETC, LL_. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization#32455 i EuIT10?: (2DZC) FeC HVH? EVALi AT10?i FL52SS-P.32 ;HVH2)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 4 of 11
NINEMO etC.
5.7 Allowable Substrates: ;a
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Substrates (designed to meet wind loads for project)
Type
Primer
;_. Matenal(s)
Polystick IR-Xe, Polystick MTS Plus,
Polystick TU Max, Polystick TU P,
. _ -...
Polyflex SA P or Polyflex SA P FR
colf_�rlhnrina
Deck
ASTM D41
structural concrete
- ,
Elastoflex S6 G or Elastoflex S6 G
FR
hot asphalt
Deck
ASTM D41
structural concrete I
Base Sheet N/A
ASTM; D226, Type II felt, Elastobase, Elastobase P
Polyflex G or Polyflex G FR
torch -applied
Deck
ASTM D41
structural corcrete
Base Sheet N/A
Elastobase, Elastobase P
!
5.8 Attachment Limitations:
Refer to Section 6
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS .
- i -
Underlayment
PrInepared Roof Cover
I - - I
stallation Type
Maximum
Exposure (days)
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
li
Mechanically attached
30
Polystick IR-Xe
Mechanically attached
90
Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick
XFR
Any type (per Table 1)
180
Elastoflex S6 G, Polyflex G or Polyflex SA P
Adhesive -set tile roof1system
180
Elastoflex S6 G, Elastoflex S6 G FR, Polyflex G, Polyflex G FR, Polyflex SA P or
Polyflex SA P FR
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method I,
Maximum Staging Slope
Elastoflex S6 G or S6 G FR
Flat or Lugged
I 6-tile stack (4 over 2)
Prohibited without battens
Polyflex G or G FR
Flat or Lugged
6 the stack (4 over 2)
i 4:12
Polyflex SA P or SA P FR
I Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
j 5:12
Lugged
I 6-tile stack (4 over 2)
4:12 I
Polystick TU Max
Flat
16-tile stack (4 over 2) or 104ile stack
I 7:12
Lugged
i 6-tile stack (4 over 2)
7:12
Lugged
10-tile stack !; .
6:12
Polystick TU P
I Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
I 6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
,
6:12
P lystick XFR
Flat or Lugged
Prohibi ed without battens
;Prohibited without battens
MEMO ETC, LLC.
Certificate o/Authorization #32455
7 - EDITION (2020) F5C HVHZ EVALUATION
Polyglass, Roof Underlayments
Evaluation Report 3m-PLYG-20-FBCER.A
FL5259-R32 (HVHZ)
Revision 28: 12/21/2020
Page 5 of 11
I
NEM0 etC,
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3
6.3.1
6.3.2
6.3.3
Approved Assemblies:
Deck Type 1: Wood, Non -Insulated
veCK uescnpuun: iviin. t`i/3z piywooa or wooa planK .
System Type E: Underlayment mechanically fastened to deck
Underlayment: One or more plies of Elastobase or Elastobase P with a minimum 4-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch O.C.
in a grid -pattern between the overlaps.
Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood
shakes or wood shingles.
Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Cap Ply:
Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied or
Polyflex SA P, self -adhering
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.S).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum I -inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Cap Ply:
Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch -applied or
Polyflex SA P FR or Polystick TU P, self -adhering
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
1 N1,0 E. LLC. Evaluation Report3m-PLYG-20-FBCER.A
Certificate afAutnorization #32455 7 _ EDMC)e-, (2020) F5C HV: IZ E`v'ALUATIO`i R 5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 6 of 11
6.3.4
6.3.5
A
Deck Type 1:
Wood, Non -Insulated
Deck'Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Approved D226, Type II felt
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ ASTM with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.,
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
Cap Ply:
Polystick IR-Xe self -adhering and back -nailed max.12-inch o.c,: using FBC HVHZ Approved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles.
Deck Type l:
Wood,. Non Insulated j
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck?
,
6-inch lap and 12-inch
Fastening:
FBC-HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), o.c.lat�the -edges D.C.
in a grid -pattern between the overlaps.
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch D.C. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5) it
Cap Ply:
Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging
limitations.
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywo d or wood plank i
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
I!
Base Ply:
,
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Max, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5). I'
Surfacing:
FBC HVHZApproved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles. Refer to Table 4 for tile stagging limitations.
NEMO ETC, LLC.
Certificate of Authorization #32455
7'" EDITION (20Z0) FBC HVHZ EVALUATION
Polyglass Roof Underlayments
Eval I ation Report 3m-PLYG-20-FBCER.A
i
FL5259-R32 (HVHZ)
Revision 28: 12/21/2020
Page 7 of 11
I,
Y-y
NEM0 etc.
6.3.7
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max: 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Plus, self -adhering and back -nailed Max.. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
6.3.8 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC. HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max or Polystick TU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.S).
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table lA for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.9 f Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 6-inch end_ lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap -edges and 18-inch o.c. in two (2)
equally spaced, staggered center rows.
Cap Ply: Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table lA for
allowable tile adhesives and Table 4 for tile stagging limitations.
iEr,10 ETC, LL-. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 % " Eui T ION (2020) FBC HVHZ E`✓ALUATIO`! FL5259-P.32 (H'/H=j
Polyglass Roof Underlayments Revision 29: 12/21/2020
Page 8 of 11
NEMO eta.
6.3.10 Deck Type 1: Wood, Non Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch D.C. at the lap -edges and 8-inch D.C. in three (3)
!. +
Primer: PG100 or ASTM D41 primer applied to stress plates j
Cap Ply: Polyflex SA P, self -adhering and back -nailed max. 12-inch D.C. using FBC HVHZ Approved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached or adhesive-set,itile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
6.3.11 I
Deck Type 1:'
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch D.C. at the lap -edges land 18-inch D.C. in two (2)
equally spaced, staggered center rows.
Cap Ply:
Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch -applied
and back -nailed max. 12-inch D.C. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
6.3.12
Deck Type 1:
Wood, Non -Insulated
Deck Descripti n:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
i
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch D.C. at;the lap-edgesjand 8-inch D.C. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Cap Ply:
Polyflex SA P FR or Polystick TU P, self -adhering, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)�
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to j Table 4 for tile stagging
limitations.
NEiAO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate ofAuthorizotion #32455 7- EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 9 of 11
l
NErAo etc.
6.3.13
Deck Type 17
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P felt with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c, using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging
limitations.
6.3.14 Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails andl tin caps (FBC HVHZ 1517.S)
Cap Ply: Polystick TU Max, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails Ind
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZApproved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles. Refer to Table 4 for tile stagging limitations.
6.3.15 i Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap ar1d 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
Base Ply:
Cap Ply:
Surfacing:
N&1,110 ETC, LLC.
Certificate of Authorization #32455
PG100 or ASTM D41 primer applied to stress plates
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Polystick TU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
7 = EDITION 1"2020 FBC HVHZ EVALUATION
Polyglass Roof Underlayments
Evaluation Report 3m-PLYG-20-FBCER.A
FL5259-11321-i 1i7_)
Revision 28: 12/21/2020
Page 10 of 11
..."NEMO etC,
6.3.16 Deck Type 1:,Wood, Non -Insulated
Deck Description: Min.19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap-eciggsiand 8-inch o.c. in three (3)
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus, self -adhering and back -nailed max: 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max or Polystick TU Plus, self -adhering and back_nailed Max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5). 1
Surfacing: FBC HVHZ Approved adhesive -set the roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.17 Deck Type 3: Structural concrete, non -insulated
Deck Description: Min. 21500 psi structural concrete
System Type F: Underlayment adhered
Primer: ASTM D41
Underlayment: Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied or
Polyflex SA P, self -adhering
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.18 Deck Type 3: Structural concrete, non -insulated
Deck Description: Min. 2,500 psi structural concrete
System Type F: Underlayment adhered
Primer: ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhering
Cap Ply: Polystick TU Max or Polystick TU Plus, self -adhering
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
As required by the Building Offic
Contact the named QA entitylormanufacturing facilities covered by F.A.C. Rule 61G2'
herein for products and production locations having met codified material standards.
UL LLC — QUA9625; (414) 248-6409; Karen.buchmann@ul.com
- END OF EVALUATION REPORT -
QA requirements. Refer to Section 4
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authodwrion#32455 7- EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 11 of 11