HomeMy WebLinkAboutConstruction PlansII PRECAST DOUBLE TEE REPAIR GENERAL NOTES II CONCRETE RESTORATION NOTES 2 5 EXTENT OF REPAIR TO BE DETERMINED IN FIELD CHIP & REMOVE SPALLED CONCRETE, CLEAN ALL REINFORCEMENT COAT ALL REINFOCEMENT WITH SIKA ARMATEC 110 EPOCHEM FILL AREA WITH SIKATOP 123-PLUS W/ 3/4" COVER MINIMUM PRECAST CONCRETE JOIST & COMPOSITE FLOOR SLAB NOTE: 1. CARE SHOULD BE TAKEN TO AVOID DAMAGING ANY EXIST. CABLES. IF ANY CABLES ARE EXPOSED DURING THE REPAIR PROCESS THE E.O.R TO BE NOTIFIED SO THEY CAN BE EVALUATED. CABLES REPAIRED WILL REQUIRE GRABB-IT CONNECTORS IF DAMAGED OR CORRODED BADLY 2. IF REBAR CORROSION IS GREATER THAN 10% OF BASE STEEL REPORT DAMAGE TO FOR FOR DETAIL EXIST. CONC. SLAB PROVIDE (1) SHORING POST ON EACH SIDE OF REPAIR. (WACO OR SIMILAR W/ 5 KIP CAPACITY EACH MIN.) DOUBLET STEM REPAIR SECTION 1/4" = T-0" CHIP BACK CONCRETE AROUND EXPOSED REINF OR VISIBLE SPALLING TO EXPOSE REINFORCEMENT WITHOUT DAMAGING IT CLEAN ALL REINFORCEMENT COAT ALL REINFOCEMENT WITH SIKA ARMATEC 110 EPOCHEM FILL AREA WITH SIKATOP 123-PLUS W/ 3/4" COVER MINIMUM NOTE: DETERIORATION OF REINFORCEMENT IS LESS THAN 30% MISSING OF INDIVIDUAL WIRE AFTER CLEANING DOUBLE T FLANGE SECTION DEMO MINOR DAMAGE 1/4" = 1'-0" EXTENT OF REPAIR TO BE DETERMINED IN FIELD EXIST. CONIC. SLAB BEAM REPAIR SECTION 1/4" = 1'-0" KI 1. GOVERNING CODE: FLORIDA BUILDING CODE 7TH EDITION (2020). 2. REFERENCE STANDARDS: REFERENCE TO ASTM AND OTHER STANDARDS SHALL MEAN THE LATEST EDITION IN EFFECT ON THE BID DATE OR DATE OF OWNER - CONTRACTOR AGREEMENT UNLESS NOTED IN THESE DOCUMENTS OR DESIGNATED BY THE GOVERNING CODE, 3. NOTES: NOTES ON THE INDIVIDUAL STRUCTURAL DRAWINGS SHALL TAKE PRIORITY OVER STRUCTURAL NOTES ON THIS SHEET. 4. SPECIFICATIONS: REFER TO THE SPECIFICATIONS FOR INFORMATION IN ADDITION TO THESE NOTES AND THE STRUCTURAL DRAWINGS. 5. DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN THE PLANS, SPECIFICATIONS, REFERENCE STANDARDS & GOVERNING CODE, THE MORE STRINGENT REQUIREMENTS SHALL GOVERN. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH WORK. 6. SITE VERIFICATION: THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING WORK, AND THE ARCHITECT SHALL BE IMMEDIATELY NOTIFIED, IN WRITING, OF ANY DISCREPANCIES. IN NO CASE SHALL DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THE DRAWINGS. 7. OMISSIONS/CONFLICTS: IN CASE OF OMISSIONS AND CONFLICTS BETWEEN THE PLANS, SPECIFICATIONS AND SITE CONDITIONS, THE ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH THE WORK. 8. CONTRACTOR RESPONSIBILITIES: THE CONTRACTOR IS FESPONSIBLE FOR SAFETY AT THE SITE AND FOR THE STRENGTH AND STABILITY OF ALL PARTLY COMPLETED STRUCTURES. 9. LOAD LIMITS: LOADS ON THE STRUCTURE SHALL NOT EXCEED THE DESIGN LOADS SHOWN UNDER "DESIGN CRITERIA". 10. SUBMITTALS: WHERE SHOP DRAWINGS, MILL TESTS, OR OTHER ITEMS ARE REQUESTED, SUBMITTAL SHALL BE MADE TO THE STRUCTURAL ENGINEER PRIOR TO FABRICATION OR INSTALLATION IN THE STRUCTURE, UNLESS SPECIFICALLY NOTED. 11. ALTERNATES: ALTERNATES FOR SPECIFIED ITEMS SHALL BE SUBMITTED TO ENGINEER FOR APPROVAL. CONTRACTOR SHALL BUDGET FOR ENGINEERING FEES ASSOCIATED WITH THE REVIEW OF THESE MATERIALS. CHIP CONCRETE 1" MIN OR 1/4" ABOVE RUSTED STEEL / DAMAGED CONCRETE EXTENT OF INDIVIDUAL REPAIRS TO BE DETERMINED IN FIELD EXIST. CONC. SLAB CHIP & REMOVE SPALLED CONCRETE. CLEAN & TREAT STEEL PER SPECIFICATIONS. REPAIR PER SPECIFICATIONS. DOUBLE T ROOF SLAB NOTE: DETERIORATION OF REINFORCEMENT IS MORE THAN 30% MISSING OF INDIVIDUAL WIRE AFTER CLEANING OR WIRE BROKEN PROVIDE (1) SHORING POST ON EACH SIDE OF REPAIR. (WACO OR SIMILAR W/ 5 KIP CAPACITY EACH MIN.) DOUBLE T FLANGE SECTION DEMO MAJOR DAMAGE 1/4" = 1'-0" CHIP & REMOVE SPALLED CONCRETE. CLEAN ALL REINFORCEMENT COAT ALL REINFOCEMENT WITH SIKA ARMATEC 110 EPOCHEM FILL AREA WITH SIKATOP 123-PLUS W/ 3/4" COVER MINIMUM DOUBLE T ROOF SLAB NOTE: 1. CARE SHOULD BE TAKEN TO AVOID DAMAGING ANY EXIST REBAR. 2. IF REBAR CORROSION IS GREATER THAN 10% OF BASE STEEL REPORT DAMAGE TO FOR FOR DETAIL PROVIDE (1) SHORING POST ON EACH SIDE OF REPAIR. (WACO OR SIMILAR W/ 5 KIP CAPACITY EACH MIN.) 1. THIS PROJECT REQUIRES CONCRETE RESTORATION TO THE BEAM AND PRECAST DOUBLE T'S. DUE TO THE RUSTING OF THE REINFORCING STEEL WITHIN THE CONCRETE. 2. THE STRUCTURE SHALL BE INSPECTED AND THE EXACT SCOPE OF REPAIR WORK DETEMINED BY AN CONTRACTOR PRIOR TO BID. 3. REPAIR OF THE CONCRETE AND TREATMENT OF THE STEEL SHALL BE DONE IN ACCORDANCE WITH THE ATTACHED DRAWINGS. 4. ALL RESTORATION SHALL BE PERFORMED UNDER THE SUPERVISION OF AN ENGINEER. SCOPE OF WORK 1. REPAIR OF ON AN EXISTING CAST IN PLACE BEAM AND PRECAST DOUBLE T'S OF AN EXISTING BUILDING. PLACE WWR 3X3 W2.9XW2.9 COAT ALL REINFOCEMENT WITH SIKA ARMATEC 110 EPOCHEM FILL AREA WITH SIKATOP 123-PLUS W/ 3/4" COVER MINIMUM DOUBLE T FLANGE SECTION REPAIR MAJOR DAMAGE 1/4" = 1'-0" FIL COP' 3S3 RGD CONSULTING ENGINEERS JUPITER'.ORLANDO '.. 561-743-0165 407-845-6630 WWW.RGDENGINEERS.COM STRUCTURAL RGD CONSULTING ENGINEERS ENGINEER: 2151 SOUTH HIGHWAY AIAALT SUITE 2000, JUPITER, FL 33477 SIGNATURE AND SEAL: RGD ENGINEERS: STEPHEN G PETERS DISCIPLINE: STRUCTURAL FL P.E. NO. 88497 CERT. OF AUTH, 5454 1��11rrrllrll/�fJjr{ �4tol i i s STA(y/�J //7 ♦ w: DATE REVISIONS: NO. DESCRIPTION DATE KEY PLAN AREA DESCRIPTION PROJECT ADDRESS 3150 WILL FEE RD, FORT PIERCE, FL 34982 PROJECT NAME: ST. LICIE COUNTY MOSQUITO CONTROL CARPORT REPAIR DATE: 11/04/2021 RGD PROJ. NO: 21-1173 SCALE: AS SHOWN DRAWN: JP CHECKED: SGP SHEET NAME: PRECAST DOUBLE TEE REPAIR DETAILS SHEET NO. S1.1 PROJECT PHASE: PERMIT SET `NOT ISSUED FOR CONSTRUCTION Q Q „ Q Q 40 - 0 13' - 4" J, 13' - 4" 13' - 4" v �o EXIST. ROOF FRAMING PLAN 3/16" = V-0" OF DOUBLE T FLANGE 4G AND/OR REBAR VISIBLE SPALLING TYPICAL 31.1 EM SIBLE AL (LJ 3 2 5 EXIST. PRECAST DOUBLE TEE TO REMAIN SECTION 3/4" = 1'-0" EXIST. PRECAST -1 `•' F DOUBLE TEE TO REMAIN 4 SECTION 3/4" = 1'-0" (1) 3/4" 0 A325 THROUGH BOLT @ 12" O.C. (2) 1" 0 A325 THROUGH BOLT AT EXIST. CONC. COLUMN LOCATION ELEVATION 3/4" = 1'-0" (2) 1" 0 A325 THROUGH BOLT AT EXIST. CONC. COLUMN LOCATION ELEVATION 3/4" = 1'-0" —(1) 3/4" 0 A325 THROUGH BOLT @ 12" O.C. STEEL CHANNEL BEAM PER PLAN EXIST. CONCRETE BEAM TO REMAIN PAD (2) 1" 0 A325 THROUGH BOLT AT EXIST. CONC. COLUMN LOCATION STEEL CHANNEL BEAM PER PLAN EXIST. CONC. BEAM TO REMAIN EXIST. CONC. COLUMN TO REMAIN EXIST. PRECAST DOUBLE TEES TC REMAIN 5" 5" 7" ITI ( !� NEW STEEL CHANNEL PER PLAN I 1) ), EXIST. CONCRETE BEAM �� <-• I TO REMAIN I EXIST, CONCRETE COLUMN ` TO REMAIN EXIST. PRECAST DOUBLE TEES TO REMAIN 7„ i^ NEW STEEL CHANNEL F - `�-"—•�—`� PER PLAN d I, EXIST. CONCRETE BEAM •'-• ".0 TO REMAIN (1) 3/4" O A325 THROUGH BOLT i @ 12" O.C. I EXIST. CONCRETE COLUMN -� TO REMAIN GENERAL STRUCTURAL NOTES APPLICABLE CODES AND STANDARDS 1. 2020 FLORIDA BUILDING CODE (7TI-I EDITION) 2. ASCE/SEI 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES 3. AISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS 4. ASTM MATERIAL STANDARDS AS NOTED. MATERIALS OF CONSTRUCTION 1. STRUCTURALSTEEL ANGLES, CHANNELS AND PLATE -ASTM A36 Fy = 36 KSI BOLTS ASTM A325 CONSTRUCTION NOTES A. GENERAL CONSTRUCTION NOTES 1. THE CONTRACT DOCUMENTS CONSIST OF DRAWINGS AND DESIGN INFORMATION PREPARED BY MULTIPLE DISCIPLINES AND MUST BE USED AS A WHOLE AND IN COORDINATION WITH EACH OTHER. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY APPARENT DISCREPANCIES OR OMISSION OF INFORMATION NOT SHOWN ON THE STRUCTURAL DRAWINGS DURING THE SHOP DRAWINGS SUBMITTAL PROCESS. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTING ERRORS RESULTING FROM LACK OF COORDINATION OF DOCUMENTS. 2. STRUCTURAL DRAWINGS SHOULD NOT BE SCALED. PRINTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS AND LARGE SCALE DETAILS OVER SMALL SCALE. 3. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS. CHECK AND VERIFY EXISTING DIMENSIONS AND ELEVATIONS AND TAKE ADDITIONAL MEASUREMENTS AS NEEDED BEFORE STARTING ANY WORK NOTIFY ENGINEER OF ANY DISCREPANCY BETWEEN ACTUAL CONDITIONS AND INDICATED CONDITIONS. MODIFICATION OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE ENGINEER. 4. TYPICAL DETAILS SHALL APPLY IN GENERAL CONSTRUCTION UNLESS SPECIFICALLY DETAILED, WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. 5. THE CONTRACTOR SHALL PROVIDE AND BE RESPONSIBLE FOR THE PROTECTION AND REPAIR OF ADJACENT EXISTING SURFACES AND AREAS WHICH MAY BE DAMAGED BY NEW WORK, 6. UNLESS NOTED OTHERWISE, TESTING AND INSPECTION SERVICES CALLED FOR SHALL BE PAID BY THE OWNER, AND ARE NOT PART OF THE BASIC DESIGN SERVICES OF THE STRUCTURAL ENGINEER. B. STRUCTURAL STEEL 1. FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS", LATEST EDITION. ALL STRUCTURAL STEEL CONSTRUCTION SHALL CONFORM TO THE CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES. 2. ALL FIELD BOLTED SHEAR CONNECTIONS SHALL BE MADE WITH 3/4" DIAMETER ASTM A325 HIGH STRENGTH BOLTS UNLESS NOTED OTHERWISE. BEAM SHEAR CONNECTIONS SHALL BE DESIGNED BY THE FABRICATOR FOR THE REACTIONS SHOWN ON THE PLANS, OR IF NOT SHOWN, PROVIDE THE MAXIMUM NUMBER OF BOLTS THAT CAN BE INSTALLED AT 3" ON CENTER IN ONE ROW, 3. STRUCTURAL STEEL MEMBERS OUTSIDE OF THE BUILDING ENVELOPE SHALL BE PRIMED AND PAINTED UNLESS NOTED OTHERWISE. 4. STRUCTURAL STEEL SHOP DRAWINGS, PREPARED BY THE STEEL SUBCONTRACTOR, SHOWING COMPLETE DIMENSIONS AND DETAILS, SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION OF THE STEEL COMPONENTS. THE STRUCTURAL STEEL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING, VERIFICATION AND COORDINATION OF DIMENSIONS AND DETAILS WITH THE STRUCTURAL AND OTHER PORTIONS OF THE CONTRACT DRAWINGS, THE STEEL SUBCONTRACTOR SHALL NOT REPRODUCE ANY PORTION OF THE STRUCTURAL CONTRACT DRAWINGS FOR UTILIZATION AS SHOP DRAWINGS, UNLESS APPROVAL OF THE STRUCTURAL ENGINEER IS OBTAINED. C. SHOP DRAWINGS 1. SHOP DRAWINGS SHALL BE SUBMITTED IN COMPLETE PACKAGES FOR THE FOLLOWING: A. STRUCTURAL STEEL & CONNECTIONS. 2. PRE-ENGINEERED ITEMS SHALL BE SUBMITTED SIGNED AND SEALED BY A SPECIALTY ENGINEER REGISTERED IN THE STATE OF FLORIDA. NOTE: ONCE STRUCTURAL REPAIRS ARE COMPLETED (1) ALL CONCRETE AREAS ARE TO BE SEALED WITH A PENETRATING CONCRETE SEALER SUCH AS SIKAGUARD SN-40 (2) A ROOF SPECIALIST SHALL REVIEW ROOF MEMBRANE AND MAKE ANY REPAIRS NECESSARY TO KEEP WATER FROM FURTHER DAMAGING STRUCTURE. SPECIAL NOTICE 10 BE TAKEN AT AREAS WHERE REBAR DETERIATION HAS OCCURED. ESPECIALLY AT JOINTS BETWEEN DOUBLE T'S. RGD CONSULTING ENGINEERS JUPITER ORLANDO 561-743-0165 407-845-6630 W W W. RGDENGINEERS.COM STRUCTURAL RGD CONSULTING ENGINEERS ENGINEER: 2151 SOUTH HIGHWAY A1AALT SUITE 2000, JUPITER, FL 33477 SIGNATURE AND SEAL: RGD ENGINEERS: STEPHEN G PETERS DISCIPLINE: STRUCTURAL FL P.E. NO. 88497 CERT. OF AUTH. �5+454 N ENS ........... •' V / l 0. S to .01 DATE REVISIONS: NO. DESCRIPTION DATE KEY PLAN AREA DESCRIPTION PROJECT ADDRESS: 3150 WILL FEE RD, FORT PIERCE, FL 34982 PROJECT NAME: ST. LICIE COUNTY MOSQUITO CONTROL g CARPORT REPAIR " DATE:11/04/2021 RGD PROJ. NO: 21-1173 SCALE: AS SHOWN DRAWN: JP CHECKED: SGP SHEET NAME: GENERAL NOTES, PLANS & DETAILS SHEET NO. S1.0 PROJECT PHASE: PERMIT SET `NOT ISSUED FOR CONSTRUCTION