miAm � MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Clopay Building Products Company
8585 Duke Boulevard
Mason, OH 45040
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In
Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code, including
the High Velocity Hurricane Zone.
DESCRIPTION: Commercial Ribbed W6 DP36 Steel Sectional Garage Door up to 12'-2" Wide with
Optional EPS Insulation
APPROVAL DOCUMENT: Drawing No.104811, titled "Commercial Ribbed Steel Doors up to 12'-2"
W", sheets 1 through 3 of 3, dated 04/15/2015, with revision 5 dated 09/09/2020, prepared by Clopay
Building Products Company, signed and sealed by Mark Westerfield, P.E., bearing the Miami -Dade County
Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -
Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model number, the
positive and negative design pressure rating, indicate impact rated if applicable, installation instruction drawing
reference number, approval number (NOA), the applicable test standards, and the statement reading `Miami -Dade
County Product Control Approved' is to be located on the door's side track, bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 20-0512.03 and consists of this page 1 and evidence pages E-1 and E-3, as well as
approval document mentioned above.
The submitted documentation was reviewed by Sifang Zhao, P.E.
NOA No 20-0922.53
t�u� an.couNn ` Expiration Date: July 02, 2025
12/24/2020 Approval Date: December 24, 2020
Page 1
`i
Clopay Building Products Company
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs
A. DRAWINGS
1. Drawing No. 104811, titled "Commercial Ribbed Steel Doors up to 12'-2" W", sheets 1
through 3 of 3, dated 04/15/2015, prepared by Clopay Building Products Company, signed
and sealed by Mark Westerfield, P.E. "Submitted under NOA #15-0423.06"
2. Drawing No. 104811, titled "Commercial Ribbed Steel Doors up to 12'-2" W", sheets 1
through 3 of 3, dated 04/15/2015, with revision 3 dated 07/17/2017, prepared by Clopay
Building Products Company, signed and sealed by Mark Westerfield, P.E.
"Submitted under NOA #17-0809.20"
B. TESTS
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
4) Forced Entry Test, per FBC TAS 202-94
5) Tensile Test per ASTM E8
along with marked -up drawings and installation diagram of Clopay Model 524, 12'-2" wide x
8' high, 24 ga. steel garage doors, prepared by American Test Lab, Inc., Test Report No.
ATLNC 1103.01-14, dated 12/22/2014, signed and sealed by David W. Johnson, P.E.
"Submitted under NOA #15-0423.06"
3. Test report on Salt Spray per ASTM B 117 of painted G40 galvanized painted and G90 panels,
prepared by Fenestration Testing Laboratory, Inc., Test Report No.7890, dated 10/01/2014,
signed by Idalmis Ortega, P.E. "Submitted under NOA #15-0423.06"
C. CALCULATIONS
1. Anchoring calculations prepared by Clopay Building Products Company, dated 04/20/2015,
signed and sealed by Mark Westerfield, P.E. "Submitted under NOA #15-0423.06"
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Test report on Ignition Properties of Plastics per ASTM D1929 of Premier Industries' Type I
EPS, Report No. 3082959-500, prepared by Intertek Testing Services, NA, Inc., dated
09/16/2005, signed by C. Anthony Penaloza. "Submitted under NOA #15-0423.06"
2. Test report on Surface Burning Characteristics, per ASTM E84 of Premier Industries' Type I
EPS, Report No. 3082960-500, prepared by Intertek Testing Services, NA, Inc., dated
10/04/2005, signed by Javier Trevino. "Submitted under NOA #15-0423.06"
F. STATEMENTS
1. Statement letter of code conformance to 2010, P Edition (2014) and 6t" Edition (2017) FBC
issued by Clopay Building Products Company, dated 08/02/2017, signed and sealed by Mark
Westerfield, P.E. "Submitted under NOA #17-0809.20"
1. Certificate of amendment changing the company name from Clopay Building Products
Company, Inc. to Clopay Corporation, issued by the State of Delaware, dated 08/27/2019.,
"Submitted under NOA #20-0512.03"
C
Sifang Zhao P.E.
Product Control Examiner
NOA No 20-0922.53
Expiration Date: July 02, 2025
Approval Date: December 24, 2020
E-1
Clopay Building Products Company
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
3. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. 104811, titled "Commercial Ribbed Steel Doors up to 12'-2" W", sheets
1 through 3 of 3, dated 04/15/2015, with revision 5 dated 09/09/2020, prepared by
Clopay Building Products Company, signed and sealed by Mark Westerfield, P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 6th Edition (2017) FBC, 7th Edition (2020)
FBC, and Statement letter of no financial interest, issued by Clopay Corporation,
dated 09/15/2020, signed and sealed by Mark Westerfield, P.E.
Sifang Zhao P.E.
Product Control Examiner
NOA No 20-0922.53
Expiration Date: July 02, 2025
Approval Date: December 24, 2020
E-2
4 J
L
I1
CLOPAY / IDEAL / HOLMES
SHEET
REVISIONS
524
/ C4ST / 224 / 24GA 1-7/8' RIBBED
1 OF 3 REV. NO. ZONE:
I DATE:
I ECN NO. APPVD:
DESCRIPTION
524V
/ C4SV / 224V / 24GA 1-7/8' RIBBED INSULATION
524S
/ C4SS / 224X / 24GA 1-7/8' RIBBED INSULATION WITH STEEL BACKER
02 -
a/75/75
- MWW
REVISED LAYOUT 10 3 PAGES
520
/ COST / --- / 20GA 1-7/8' RIBBED
03 -
7/17/17
- SH
UPDATED CODE COMPLIANCE STATEMENT TO ADD 6TH EDITION FBC.
520S
/ COSS / --- / 20GA 1-7/8' RIBBED INSULATION WITH STEEL BACKER
04 -
3/W20
- MWW
UPDATED TITLE BLOCK
OS -
9/9/20
- SH
UPDATED CODE COMPLIANCE STATEMENT TO 7TH EDITION FBC
3" x 20 GA. GALV. STEEL U-BARS ARRANGED WITH 2 U-BARS
PER SECTION U-BARS ATTACHED AT EACH STILE LOCATION
WITH (2) 1/4" x 3/4" SELF -TAPPING SCREWS
.0'
I ' �l I7i111 �
•1
n ■ n
I —I —I —II —I ■
L--mAX.
,■■' WIDTH,
PRODUCT REVISED
as compWIng with the Florlda
Building Code
NOA-No. 20.0922.53
Expiration Data
D�gata 07/02/2025
By
Miami -Bade Product Control
A
A Zb
ra
Aw
TAnI C 1
A'
DOOR EIG
TOTAL U-BARS
REQUIRED
TO 6 0
6
63 TO 80
B
103 TO 12T0
1102
34
14'3 TO 16 0'
16
163 TO 18
.18
#14x5/8' SHEET
VMETAL SCREWS.
TA/PPING
3/4• SELF
SCREWS. O
14 GA. END HINGES 14 GA. (MIN INTERMEDIATE HINGE
VIEW •B" VIEW "C"
SNAP LATCH ENGAGES
ONTO VERTICAL TRACK.
ONE SNAP LATCH ON
SLIDE BOLT LOCK EACH SIDE OF DOOR.
END ENGAGES INTO
STILE VERTICAL TRACK.
ONE LOCK ON
EACH SIDE OF OUTSIDE
DOOR. KEYED END
HANDLE STILE.
INSIDE SLIDE BOLT INSIDE HANDLE
LOCK OPTION. OUTSIDE KEYED LOCK WITH
SNAP LATCH LOCK OPTION,
3
DOOR HEIGHT `A'
NUMBER OF
SECTIONS
UP TO 8'-0'
4
8'-3' THRU 10'-0'
5
10'-3' THRU 12'-0'
6
12'-3' THRU 14'-0'
7
14'-3' THRU 16'-0'
B
16'-3' THRU 18'-0'
9
Illy
IN
THIS PRODUCT CONFORMS
TO THE REQUIREMENTS OF
GTH AND 7TH EDITION OF
THE FLORIDA BUILDING
END
CODE
STILE.
MANUFACTURING PRODUCT CODE
C—PAN—lE448
OUTSIDE
DESIGN LOADS: +36.0
P.S.F. & -42.0 P.S.F. PART NO.- N/A
HANDLE LOCK BAR
ENGAGES IN
U.1— Stnt d Othenhe
TOLERANCES
rj'QP ay,]
85&5 Duke boulevard W[N➢LOAD RATING
uason, oR 45040 usa
A
TRACK ON
R. �: 51 W 6 D P 3 6
EACH SIDE
.0 a f.0S1
PORATION
,�e°ss
OF DOOR.
•00 a t.015
DESCRIPTION: COMMERCIAL RIBBED STEEL DOORS UP TO 12'2'W
OUTSIDE KEYED LOCK WITH
.000 o t.005
0000 f.001
DRAWN BY: SH
DATE 12/1/14 SCALE: Nis DWG.
LOCK BAR LOCKING.
Degrees - tt/2
CHECKED BY: MWW
DATE: 4/15/15 SHEET 1 OF 3 SIZE
i.
Diums Ns dAREEIIN I ' mmEs. DWG. NO.: 104811
VER: M-D
2
CLOPAY / IDEAL / HOLMES SHEET-
524 / C4ST / 224 / 24GA 1-7/8' RIBBED 2 OF 3 REV,
524V / C4SV / 224V / 24GA 1-7/8' RIBBED INSULATION
524S / C4SS / 224X / 24GA 1-7/8' RIBBED INSULATION WITH STEEL BACKER 05
520 / COST / --- / 20GA 1-7/8' RIBBED
520S / COSS / --- / 20GA 1-7/8: RIBBED INSULATION WITH STEEL BACKER
D
NRQONTAL (TOP) JAMB
(N LOAD FROM DOOR)
FASTENER
TYPE
MAX. O.C.
2.6 VERTICAL JAMB
3
PRODUCT REVISED
as compiying with the Florida
Building code
NOA-No. 20-0922.53
Expiratiti'oon DData 07/02/2025
By
Miami -Dade Product Control
DESIGN EN351" R.
MARK WESTERFIELD, P.E.
FLORIDA P.E. #4E495
4
JAMB TO SUPPORTING STRUCTURE ATTACHMENT
NOTES:
1 TTHE 2x66 THE VERTICAL SYP THE
S2 ODOOR IS TRANSFERRED TTER) JAMBS. NOT OAD�FROM TTHHE DOOR OM IS TRACK TO
TRANSFERRED TO THE HORRONTAL (TOP) JAMB.
2. EACH VERTICAL JAMB SEES A MAXIMUM DESIGN LOAD OF +185 LB & -220 LB. PER LINEAR
FOOT OF JAMB.
3. ALL JAMB FASTENERS MAY BE (BUT ARE NOT REQUIRED TO BE) COUNTERSUNK TO PROVIDE A
FLUSH MOUNTING SURFACE
4. A 1/3 STRESS INCREASE FOR WIND LOAD WAS HU USED IN THE CALCULATION OF ALLOWABLE
LOADS FOR ANCHORS AND FASTENERS FOR STEEL, CONCRETE AND MASONRY.
NOTE: 2X6 WOOD JAMBS ARE NOT REQUIRED WITH CONTINUOUS ANGLE MOUNT TRACK. HOWEVER,
IF DESIRED ON STEEL. JAMBS OR CONCRETE OR BLOCK WALLS, APPROVED FASTENERS AS
DETAILED BELOW SHOULD BE INCREASED IN LENGTH BY 1-1/2' AND INSTALLED DIRECTLY
THROUGH THE ANGLE AND 2x6 WOOD JAMBS INTO THE STEEL JAMBS OR CONCRETE OR BLOCK
WALLS. ANCHORS CAN BE (BUT ARE NOT REQUIRED TO BE) COUNTERSUNK TO PROVIDE A FLUSH
MOUNTING.SURFACE CONTINUOUS ANGLE TRACK CAN BE ANCHORED DIRECTLY TO GROUT
REINFORCED BLOCK WALL OR 3,000 PSI MIN. CONCRETE COLUMN OR STEEL JAMBS.
1-13„ - VIEW "E'
1 _7 /A4 3' TALL 50 KSI U-BAR
1-7q
20 GA GALV. STEEL
FASTENER ATTACHMENT TO SUPPORTING STRUCTURE SCHEDULES
Z I 1
REVISIONS
DATE: ECN NO. APPVD: I DESCRIPTION
-- - -- I SEE REVISION HISTORY ON SHEET ONE
OPTIONAL It POLYSTYRENE INSULATION
CSEE MODEL EXPLANATION)
TONGUE 8 GROOVE
BUILDING TYPE
FASTENER TYPE
FASTENERS*EOUIBETWEEN
TEEL
REDI
HOLLOW OC
4' - 4' I
' O.D.
GROUT FILLED BLOCK W
1 4 x 1-3 4 MiN. EMBED ULTRACON CONCRETE CHOR1
O.D.
2000 Psi MIN. CONCRETE
1 4 x 1 MIN. EMBED ULTRACON CONCRETE ANCHOR1
41h._1111
O.D.
2000 PSI MIN. CONCRETE
1 4 x 1 MIN. EMBED TAPCON CONCRETE ANCHOR1'
O.D.3
8 x 1-3 4 MIN. EMB WEJ-IT AN.TITSSLEEVE ANCHOR4000
PSI MIN. N
--
N U5
3'
7 0.0.114GA
STEEL 0-060- MIN.)_
_
1 0. ._
_1
.D.
I
O.D.
• FIRST (BOTTOM) ANCHOR STARING AT NO MORE THAN HALF OF THE MAXIMUM ON -CENTER DISTANCE HIGHEST ANCHOR INSTALLED
AT LEAST AS HIGH AS THE DOOR OPENING.
CLOPAY DOES NOT SUPPLY JAMB ATTACHMENT FASTENERS.
MINIMUM DISTANCE BETWEEN CENTER OF ANCHOR AND EDGE OF CONCRETE BLOCK 2-1/2', EXCLUDING STUCCO THICKNESS.
3
3' X 20 GA GALV STEEL U-BAR. TWO U-BARS ON
EYERY SECTION. SEE TABLE 1.
EACH U-BAR ATTACHED WITH (2) 1/4'x3/4'
SELF -TAPPING SCREW PER STILE LOCATION.
METAL SCREWS ADJUSTABLE SLIDE
ATTACHED TO TOP MET WITH (W
1/4'xI/2' SULTS AND NUTS PER BRACKET,
14 GA. GALV. ROLLER MING. EACH
M NGE FASTENED WITH (4)
014x5/S'-SHEET METAL-SCREVS
AND (4) 1/4'0/4' SELF -TAPPING
SCREWS. SEE VIEW B
BOTTOM ROLLER BRACKET OF 13 GA
GALV, STEEL (MEASURING 3' x
9-1/8' MIN), FASTENED WITH (4) t14
BOTTOM SECTION RED,fFURCE➢ X 5/e' LG SHT. KTL SCREWS
WITH TEMPERED ALUMINUM
EXTRUSION WITH INTEGRAL O
RETAINER FOR FLEXIBLE VINYL
ASTRAGAL
SECTION A -A (SIDE VIEW
s
'n
IN
I:
C-PAN-lE448
DESIGN LOADS: +36.0 P.S.F. & -42.0 P.S.F.
PART NO.: N/A
UM— Stated Oth—I a
85M Duke Boulevard
WINDLOAD RATING
A
TOLERANCES a a
Clopa Maso➢, OH 45040 USA
Tox No.513-nG-4853
W 6 D P 3 6
.0 = f.031
CORPORATIO Fax No. STD-T70-4853
DESCRIPTION: COMMERCIAL RIBBED STEEL DOORS UP TO 12'2'W
.00 d:.015
.000 t.005
.0000 = d:.001
DRAWN BY: SH
DATE: 12/1/14
SCALE: NITS
DWG. D
Degr = tl/T
CHECKED BY: MWW
DATE: 4/15/15
SHEET 2 OF 3
ISIZE .1,
U,d— Stated OU mrisa
OwEwoxs ARE IN INCHES.
DWG. NO.: 104811
VER: M-D
pj
7
CLOPAY / IDEAL / HOLMES
524 / C4ST / 224
/ 24GA 1-7/8' RIBBED
524V / C4SV / 224V
/ 24GA 1-7/8' RIBBED INSULATION
524S / C4SS / 224X
/ 24GA 1-7/8' RIBBED INSULATION WITH STEEL BACKER
520 / COST / ---
/ 20GA 1-7/8' RIBBED
520S / COSS / ---
/ 20GA 1-7/8' RIBBED INSULATION WITH STEEL BACKER
2' TRACK CONFIGURATION
HORIZONTAL TRACK
DOORS UP TO 800 LBS,
SUPPORT BY DOOR
INSTALLER (TO SUIT).
DOOR
NOTE DOUBLE TRACK
DOOR COUNTERBALANCE SYSTEM
'I
HEADROOM, HI-UFT TRACK,
HEIGHT
,-0
FOLLOW -THE- ROOF
TRACK, AND VERTICAL UFT
TRACK ARE AVAILABLE
3 GA GALV. STEEL FLAG BRACKET ATTACHED TO
AMB WITH (3) 5/16' X 1-5/8' LAG SCREWS
-
',
_
OPTIONS.
�••ND
TO TRACK WITH (2) 1/4' RIVETS.
TRACK CONFIGURATION
fam-E-ED
8 -0 t
ABOVE THE DOOR OPENING
EQUENT TRACK BRACKETS ON 24'
9-0
DOES NOT AFFECT THE
TERS. AS REQUIRED: SPACING NOT TO
WIND LOAD RATING.
=
30' O.C. FRON TOP TRACK
.� _� ,
x
0
t
13 L'
x
PRODUCT REVISED
i
as comptying with the Florida
Building Code
o
..Na. 20-0922.53
Expiration Date 07/02/2025
By
Mlami-Dade Product Control
3' TRACK CONFIGURATION
DOORS 800 LBS AND OVER,
N= DOUBLE TRACK
HEADROOM, HI-UFT TRACK,
FOLLOW -THE- ROOF
TRACK, AND VERTICAL LIFT [/
TRACK ARE AVAILABLE
OPTIONS.
TRACK CONFIGURATION
ABOVE THE DOOR OPENING
DOES NOT AFFECT THE
WIND LOAD RATING.
A
DESIC
MARK N
u
w
x
t
VERTICAL
cTH �
2 x
6 z
108
3 0
156
I
4
BRACKET AND FAG BRACKET.
62't4' 2' GALV. STEEL TRACK,
TRACK THICKNESS: 0.060'.
TYP. 2-1/2' X 12 GA GALV.
STEEL TRACK BRACKETS OR
TRACK CUPS, ATTACHED TO JAMB
WITH (1) 5/16' X 1-5/8' LAG
SCREW PER TRACK BRACKET OR
TRACK CUP.
L I I
SHEET' REVISIONS
3 OF 3 REV. NO. ZONE: DATE: ECN NO. APPVD: I DESCRIPTION
05 - -- - -- I SEE REVISION HISTORY ON SHEET ONE
JAMB CONFIGURATION
DOORS UP TO 800 LBS. ANGLE MOUNT JAMB CONFIGURATION
OPTIONAL STOP MOULDING 2x6 SYP JAMB (IF PRESENT;
BY INSTALLER (TO SUIT).
D
BRACKET MOUNT JAMB CONFIGURATION
SEE JAMB NOTES ON SHEET 2).
18 CA GALV 2-3/4' WIDE STEEL GALV. END STILE VERTICAL TRACK BE
1' DOOR OVERLAP (EACH SIDE)
FASTENED TO DOOR SIGN WITH TOG-L-LOC, 2 EACH
()
CONTINUOUS OR REVERSE
TOP &BOTTOM, AND (4) VERTICALLY.
1 ;1;r•:
X12ANGLE
1-3/4' % 2-1/4' % 12 CA.
2x6 SYP WOOD JAMB.
2'x1-7/8' 18 GA GALV. INTER. STILE ATTACH
Yi•.(X.t;f.,�::"
WALL ANGLE. 12 GA TRACK
REQUIRED FOR BRACKET
TO SKIN WITH LOG-L-LOCS (2) AT TOP &
„(`;5�'`.'3,?;',' CUPS ATTACHED TO WALL ANGLE
MOUNT.
BOTTOM AND (1) AT EACH "OR RIB.
WITH TWO 1/4' RUM PER CUP.
TRACK CUPS ARE ATTACHED TO
TRACK WITH EITHER TWO 1/4'
2-1/2' % 12 GA GALV. STFi1
RIVETS OR ONE 1/4' BOLT AND
TRACK BRACKETS FASTENED TO
b NUT. ONE X 5/8 LAG
WOOD JAMBS WITH 5/6' X
EACH K CUP
7/16' I.D. ROUND SCREW AT EACH TRACK CUP
1 -5/8' LAG SCREWS NOT TO
PUSH NUT FASTENER. LOCATION. ALSO TWO LAG
EXCEED 30' ON -CENTER.
14 GA. CALV. STEEL CENTER
HINGE FASTENED TO SECTION SCREWS LOCATED ABOVE
W/(4) EACH a14x5/8' SHEET VERIICAL/HORIZONTAL TRACK
METAL SCREWS. JUNCTION.
2' GALV. STEEL TRACK FASTENED TO
14 GA. GALV. STEEL ROLLER HINGES FASTENED TO END STILES W/(4) EACH Q14x5/8'
12 GA GALV STEEL TRACK BRACKETS
WITH EITHER (2) 1/4' OIA. RIVETS OR
SHEET METAL SCREWS AND (4) 1/4' SELF TAPPING SCREWS PER END HINGE
C
(1) 1/4' X 5/8' BOLT & NUT PER
2' DIA. x 4-1/2' LONG STEM (7/16' DLl SHAFT), 10 BALL STEEL ROLLER WITH STEEL
TRACK BRACKET.
OR NYLON TIRE
SECTION C-C
LHR BRACKET (2-1/2' x 5-3/4' x 12GA)
ATTACHED WITH (2) 1/4' x 3/4' SELF TAPPING
PREPARATION
OF JAMBS BY OTHERS.
SCREWS.
JAMB CONFIGURATION
HANG REQUIRED FOR DOORS 800 LBS AND OVER,
OVER 8' HIGH. 1' DOOR OVERLAP (EACH SIDE)
7 3' GALV. TAPERED STET TRACK AND ANGLE. TRACK
THICKNESS: 0.101". ANGLE THICKNESS: 0.080".
MIN. ANGLE DIMENSIONS 3-1/4' x 2-7/8'.
�_VERTICAL/HORIZONTAL TRACK
JUNCTION. TWO 1/4' BOLTS
& NUTS FOR EACH TRACK.
AS ROD: SPACING NTE 30' O.C. BETWEEN TOP VERTICAL
TRACK MOUNTING SLOT AND VERT./HORR. TRACK JUNCTION
ADDITIONAL MOUNTING SLOTS
SPACED AT 24' CENTERS.
2x6 SYP JAMB (IF PRESENT;
SEE JAMB NOTES ON SHEEP 31.EEE
HORIZONTAL TRACK
SUPPORT BY DOOR
INSTALLER (TO SUIT).
3-1/4' z 2-7/8' MIN. x 0.080' TAPERED
ANGLE SEE LAG BOLT MOUNTING AT TRACK
CONFIGURATION BELOW.
DQURLE TRACK
LOW HEADROOM OPTION
(AVAIL FOR BOTH 2' AND 3' TRACK)
t�.Okucv HORIZONTAL
OPTIONAL STOP MOULDING BY DOOR INSTALLER (TO SUIT).
18 GA GALV. 2-3/4' WIDE STEEL GAIN. END SOLE
FASTENED TO DOOR SKIN WITH TOG-L-LOC, (2) EACH
TOP & BOTTOM, AND (4) VERTCALLY.
27x1-7/8' 18 GA GALV. INTER. SALE ATTACHED B
TO SKIN WITH LOG-L-LOCS (2) AT TOP &
,. BOTTOM AND (1) AT EACH MAIOR RIB.
14 GA GALV. STEEL CENTER HINGE
FASTENED TO SECTION W/(4) EACH
/ 1 L 7/16' I.D. ROUND —#14x5/8' SHEET METAL SCREWS.
J1L PUSH NUT FASTENER.
0.101' THICK 3' GALV. STEEL TRACK FASTENED 14 GA GALV. STEEL ROLLER HINGES FASTENED TO END
TO TAPERED ANGLE TRACK ATTACHED TO STILES W/(4) EACH Q14x5/8' SHEET METAL SCREWS
TAPERED ANGLE WITH ONE 1/4'x5/8' BOLT & AND (4) 1/4' SELF TAPPING SCREWS PER END HINGE.
NUT ATTACH MOUNTING SLOT.
3' DIM. x 5-1/2' LONG STEM (7/16' DIAL SHAFT) BALL BEARING STEEL ROLLER.
riFn� SECTION C-C MANUFACTURING PRODUCT CODI
PREPARATION OF JAMBS BY OTHERS. C-PAN-1E448
ONE Y' TRACK BOLT AND NUT AT EACH
/ MOUNTING SLAT LOCATION.
10'
.77
ONE 5/16' x 1-5/8' LAG SCREW SPACED AT THE SAME
DISTANCES As THE TRACK BOLTS (I.E. 3-1/2', 107, 34', 58%
LTC.). TWO LAG SCREWS ALSO LOCATED ABOVE
VERTICAL/HORIZONTAL TRACK JUNCTION.
DESIGN LOADS: +36.0
P.S.F. & -42.0 P.S.F.
PART NO.: N/A
^
Fi
UNere stated otherrfse
TOLERANCES are
.0 d:.031
.00 a t.015
.000 = t,005
.0000 t.001
De9reeo = d:t/z
Urd— Stated Other..
DwENsoNs ARE IN mim.
— /11'O a
4 �►
CORPORA 10
8585 Duke f?aulevatd
TeL 513 0-48
Fax No. 513-770-4853
WIN➢LOAD RATING
�A/ 6 D P 3 6
DESCRIPTION: COMMERCIAL RIBBED STEEL DOORS UP TO 12'2'W
DRAWN BY: SH
DATE: 12/1/14
SCALE: NTS
DWG.R
CHECKED BY: MWW
DATE: 4/15/15
SHEET' 3 OF 31
SIZE L
DWG. NO.: 104811
VER: M-D