Loading...
HomeMy WebLinkAboutProduct Approval Exterior DoorOd5W(n) fcr�g, Business •Professional R `s • f rr f BCIS Home Log In ( User Registration I Hot Topics ( Submit Surcharge I Stats & Facts i Publications' Contact Us I BCIS Site Map i Links I Search Fbfl� Product Approval s USER: Public User .,pr i ProductApproval Menu > Product or Application Search > Application Ust > Application Detail FL # FL22513-R3 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived 0 �o Manufacturer M.a^sni1 Internaional tProduct Address/Phone/Email 1955 Powis Roa West Chicago, IL 60185 (800) 663-3667 sschrelber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Ext�eRlo_r,.=Jg9ts Subcategory Swinging�EzterlbjDoor . s em Ml s7i 4 .0 Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 11/06/2020 Date Validated 11/09/2020 Date Pending FBC Approval Date Approved 11/17/2020 FL # I Model, Number or Name I Description 22513.1 HPC Wood -edge Steel Side -Hinged 6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o Door Unit I Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When Impact resistance is required, hurricane protective system is required. Door top rails stamped "HPC". See DWG-MA-FL0212 for details. Certification Agency Certificate FL22513_R_3_C_CAC _NI013747.01-R2.pdf Quality Assurance Contract Expiration Date 06/30/2025 Installation Instructions FL22513_R3_II_FL0212.pdf Verified By: IN Accreditation &Management Institute Created by Independent Third Party: Evaluation Reports FL22513_R3_AE_514008B.pdf Created by Independent Third Party: Yes 22513.2 I Wood -edge Steel Side -Hinged Door 8'-0" Opaque I/S or O/S Single Door Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 8'-0" max nominal size. When Impact resistance is required, hurricane protective system not required. See DWG-MA-FL0215 for details. Certification Agency Certificate FL22513_R3_C_CAC_NI013747.04-Rl.pdf Quality Assurance Contract Expiration Date 06/30/2025 Installation Instructions FL22513_R3_II_FL0215._pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22513_R3_AE_514009B.pdf Created by Independent Third Party: Yes 22513.3 Wood -edge Steel Side -Hinged Door 8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. When impact resistance is required, hurricane protective system not required on opaque panels, but is required on glazed sidelites. See DWG-MA-FL0215 for details. Certification Agency Certificate FL22513_R3_C_CAC _NI013747.04-RI.pdf Quality Assurance Contract Expiration Date 06/30/2025 Installation Instructions FL22513_R3_II_FL0215.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22513_R3_AE_514007B.pdf Created by Independent Third Party: Yes 22513.4 Wood -edge Steel Side -Hinged Door 8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-45 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-0" max nominal size. When impact resistance is required, hurricane protective system not required on opaque panels, but Is required on glazed sidelites. See DWG-MA-FL0215 for details. 22513.5 Wood -edge Steel Side -Hinged Door Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. When Certification Agency Certificate FL22513_R3_C_CAC_NI013747.04-Rl.pdf Quality Assurance Contract Expiration Date 06/30/2025 Installation Instructions FL22513_R3_II_FL0215.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22513_R3_AE_514007B.pdf Created by Independent Third Party: Yes 8'-0" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites Certification Agency Certificate FL22513_R3_C_CAC_NI013747_06=R1_pdf Quality Assurance Contract Expiration Date 06/30/2025 Installation Instructions FL22513 R3_I1_FL0217.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Impact resistance is required, hurricane protective system is FL22513.__R3_AE_514007B.pdf required. See DWG-MA-FL0217 for details. Created by Independent Third Party: Yes 22513.6 } I Wood -edge Steel Side -Hinged Door 6'-8" Opaque I/S or O/S Single Door Unit I Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. When Impact resistance is required, hurricane protective system not required. See DWG-MA-FL0211 for details. Certification Agency Certificate FL22513_R3_C_CAC _NI013747-R2.pdf Quality Assurance Contract Expiration Date 06/30/2025 Installation Instructions FL22513_R3_II_FL0211..p4f Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22513_R3_AE_514010B.pdf Created by Independent Third Party: Yes 22513.7 Wood -edge Steel Side -Hinged Door 6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o Unit I Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: Evaluated for use in locations adhering to the Florida Building Code, Including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When. impact resistance is required, hurricane protective system not required on opaque panels, but is required on glazed sidelites. See DWG-MA-FL0211 for details. 22513.8 Wood -edge Steel Side -Hinged Door Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When impact resistance is required, hurricane protective system is required. See DWG-MA-FL0214 for details. Certification Agency Certificate FL22513_R3_C_CAC_NI013747-112.pdf Quality Assurance Contract Expiration Date 06/30/2025 Installation Instructions FL22513_R3_II_FL0211,pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22513_R3_AE_514008B.pdf Created by Independent Third Party: Yes 6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites Certification Agency Certificate FL22513_R3_C_CAC_NIO13747.03-R2.pdf Quality Assurance Contract Expiration Date 06/30/2025 Installation Instructions FL22513_R3_II_FL0214.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation. Reports FL22513_R3_AE_514008B,pdf Created by Independent Third Party: Yes Badc Nett Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. _Cgpydght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here_.' Product Approval Accepts: ®®070®® Credit Card s.: s4we . - NOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation Certification No.: NI013747-R2 1955 PowisRoad Certification Date: 06/08/2017 West Chicago, IL 60185 Expiration Date: 06/30/2025 Revision Date: 07/27/2020 Product: Wood -Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites (w/Wood Frame unless noted) Specification: TAS 201/202/203-94 Impact: Large Missile Impact Rated Non -Impact Glazing: Insulating Glass (Tempered) The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertification.com. NAMI's Certification Proeram is accredited by The American National Standards Tnstitnte tANsn- Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & Outswing Opaque Size Pressure Pressure Rated Comments X US Opaque 3'0" x 6'8" +70/-70 0.0 psf Yes ATLNC.1001.01-13 Single Maximum Panel Size: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 X O/S Opaque 3'0" x 6'8" +70/-70 3.0 psf' Yes ATLNC 1001.01-13/W-1857 Sitigle 4.5 psf' Maximum Panel Size: 3'0" x 6'8" 7.50 sf �•^•5 Anchor Detais DWG-MA-FL0211' 17 XX I/S Opaque 6'0" x 6'8" +55/-55 0 psf Yes NCTL-210-2930-1 Double Maximum Panel Size: 3'0" x 6'8" Anchor Details-DWG-MA-FL021 I-17 XX O/S Opaque 6'0" x 6'8" +55/-55 3.0 psfl Yes NCTL-210-2930-1 Double 4.5 psf' Maximum Panel Size: 3'0" x 6'8" 7.50 psf Anchor Details-DWG-MA-FL0211-17 XO/OX I/S Opaque Door 6'0" x 6'8" +551-55 0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelite g Glazed Sidelite Sidelite-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 XO/OX O/S Opaque Door 6'0" x 6'8" +55/-55 3.0 psfl Door -Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite 4.5 psf' Sidelite-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50 psf' Anchor Details-DWG-MA-FL0211-17 OXO US Opaque Door 9'0" x 6'8" +55/-55 0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 OXO O/S Opaque Door 910" x 6'8" +55/-55 3.0 psfl Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50psf' Anchor Details-DWG-MA-FL0211-17 OXXO I/S Opaque Door 12'4" x 6'8" +55/-55 0 psf Door -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL021 I-l7 OXXO O/S Opaque Door 12W' x 6'8" +55/-55 3.0 psfl. Door -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 1 1 7.50psf' Anchor Details-DWG-MA-FL0211-17 1-Denotes Bumper Outswing Threshold 2 -Denotes Z-Series Outswing Threshold 3-Hi-Dam Outswing Threshold 4-Pro T4 Threshold 5-HP Outswing Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: �.