Loading...
HomeMy WebLinkAboutLetter- Pre-Building Addendum1, OWN MATHERS ENGINEERING CORPORATION PRE -BUILDING PERMIT ADDENDUM Date: February 22, 2022 To: St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 EB#004456 Referenced Project: Concrete Restoration for Exterior Balconies (decks, beams & columns) For Unit Numbers for Stack 6 (106, 206, 306, 406, 506, 606 and 706) for Oceanrise Condominium Located at 10310 S. Ocean Drive, Jensen Beach, FL 34957 Contractor: DMF Construction 312 S. Old Dixie Hwy. Jupiter, FL 33458 Background: The removal and restoration of deteriorated concrete and steel within beams, columns, decks and adjacent walls will comply with the IRCI Guideline No. 03730 (a copy of which is attached hereto) or as modified by Engineer as work progresses. The anticipated work involves the initial demolition, and then the removal, replacement and restoration of concrete and reinforcement as required. The degree of restoration is currently unknown, until such time as the initial demolition has begun. The anticipated sequence of repairs is as follows: • Shoring required for repairs of all columns, beams and decks (if required by engineer) • Removal and restoration of concrete and reinforcement steel within beams, columns and decks. (ICRI Guideline No. 03730) • Minor chipping and patching of areas not requiring full depth repairs. • Applied deck coating. The following materials are approved for anticipated use in this restoration (see attached manufacturers specifications): • Sikacrete 211 Concrete Mix. • SikaQuick 1000. • Sika Armatec 110 EpoCem bonding agent and rebar coating. • Sika FerroGard 903. • Sikagard 701 W. • SikaTop 123 PLUS. • TREMCO Vulkem® 350NF 2431 SE Dixie Highway I/ Stuart, FL 34996 MATHERS ENGINEERING Phone: (772) 287-0525 CORPORATION EB#004456 See enclosed plan showing location of restoration. The above sequence is general in nature and will be modified as restoration work progresses. Observations of the initial demolition will determine any required modifications to the above procedures and materials selected for the final restoration process. Based on initial visual observations, repairs will not require shoring; however, in the event the demolition work reveals that shoring will be required, the engineer will instruct the contractor to shore the area as well as the number of levels required. The instructions given to the contractor will be submitted to the Building Department with the final close-out documents. We have been authorized by the Association to work with the contractor during the restoration and, will inspect work partially completed as well as observe results of the new demolition prior to field authorizing the repairs to be completed. The proposed concrete restoration work, except as authorized by the engineer's modified instructions, will comply with specifications outlined in the IRCI Guideline No. 03730, as well as the applicable minimum building codes and the applicable fire safety standards as determined by the local authority in accordance with Chapter 553 and Chapter 633 of the Florida Statutes where applicable to concrete restoration. \\\��`� J I A4,1 �//ii Approve�� \P.---=- William J. ivia�tMAJ II�W• Florida License #19658 Special Inspector FL License #SI-155 2