HomeMy WebLinkAboutTruss LayoutARCHITECT
Architectonic Inc
nc;6kAq
CONNECTOR SCHEDULE
TRUSS NO.
BEARING
POINT(S)
TRUSS ACTUAL
UPLIFT ( GROUPED,
WORST CASE)
SIMPSON
CONNECTOR(S)
CONNECTOR(S)
UPLIFT DESIGN
FASTENERS
A-ATC, D-GRA,
GRAT, GRID
EACH
824#
(1) HETA 20
1810#
(9) 10d x 1 1/2"
B1-B4
1ST BRG
732#
(1) HETA 20
1810#
(9) 10d x 1 1/2"
2ND BRG
666#
(1) MTS 16
990#
(14) 10d x 1 1/2"
GRB
1ST BRG
1676#
(1) HETA 20
1810#
(9) 10d x 1 1/2"
2ND BRG
1734#
(1) MTS 16
(1) H10S
990#
910#
(14) 10d x 1 1/2"
(8) 8d x 1 1/2" TO TRUSS, (8) 8d x 2 1/2" TO STUDS
GRP
EACH
2O75#
(1) HHETA 20
2120#
(10) 10d x 1 1/2"
KING JACKS
1ST BRG
743#
(1) HETA 20
1810#
(9) 10d x 1 1/2"
2ND BRG
591#
(1) MTS 16
990#
(14) 10d x 1 1/2"
HIP JACKS
1ST BRG
157#
(1) HETA 20
1810#
(9) 10d x 1 1/2"
2ND BRG
591# NAILED PER TRUSS COMPANY
VALLEY TR.
48" O.C.
672#
(1) MTS 16
990#
(14) 10d x 1 1/2"
PIGGY BACK
48" O.C.
203#
(1) MTS 16
990#
(14) 10d x 1 1/2"
TRUSS INFORMATION TAKEN FROM MANUFACTURER'S SHOP DRAWINGS. CHAMBERS TRUSS, JOB # 77700, DATED 07/30/21. ALL LOADS REPRESENT WORST
CASE LOADING FOR GROUPED CATEGORIES. REFER TO MANUFACTURER'S TRUSS LAYOUT FOR TRUSS ID AND STRAPPING PLACEMENT,
806 DELAWARE AVENUE
FORT PIERCE, FLORIDA 34950
T: 772 460 7751
F: 772 460 4244
W W W.ARCHITECTON IC ING.COM
STATE REG # AA26003348
COPYRIGHT 2021
1 PROJECT
REVELS
RESIDENCE.
IST. LUCIE COUNTY, FL
CLIENT
1 CONSULTANTS
1 REGISTRATION
Sc
u}; 9
C,, •,, t l 23 �7.�.z�
MICHAEL J SEAL, AIA
AR96898
REVISIONS
INO.1 DATE I REVISION
V
KEY PLAN
SHEET TITLE / SHEET
1NUMBER
T ®® S 6®
N. .
PROJECT NUMBER R18102
DATE 11/09/2021