Loading...
HomeMy WebLinkAboutBuilding Plans 12-21-21ATTIC VENTILATION CALC MIN CITY OF • AREA RATIO AREA REQ SOFFIT VENTS FRONT PORCH 617 SFJ 150 592 SI 51 82 LFI 16 LF REAR PORCH 383 SFI 1501 368SIl 3 48 LF1 6 LF GARAGE 563 SF 150 540 SI 5 32 LF 6 LF 1'd/11RXRX1M12111 i2/2r/zt THICKNESS ON FLOOR ID DESCRPTION SPECS PLAN FLOOR PLAN- DIMENSIONED PROJECT SPECS: 1. INSULATION: R20 SPRAYFOAM @ CONDITINED ROOF DECK, & ATTIC SEPARATING KNEE WALLS @ PORCHE,' & GARAGES. R-13 BATT @ GARAGESEPARATING WALL, FLOOR TO CLG. PROVIDE ACCESS HATCH TO CONNECT ATTIC SPACES. SLOPE AS PER ELEV METAL OVER PEEL/STICK OVER 5/8" CDX PLY OVER PE WOOD _ ROOF TRUSS AS PER FRAMING PLAN. PE TRUSS AS PER FRAMING PLANS - INSULATION AS PER PROJECT SPECS SEE FRAMING PLANS OR CONNECTOR SCHEDULE METAL DRIP OVER PT WOOD DRIP OVER 2x8 CEDAR FASCIA TO TRUSS ENDS W/ (2) #16d NAIL, -5.5" TRUSS HEEL UNVENTED ALUM SOFFIT PANELS LINTELS PER DOOR/WINDOW/LINTEL SCHEDULE STUCCO OVER 8x8x16 CMU W/ #5 VERT REBAR @ 48" OC W/ CONT CMU BOND BEAM TOP (2) COURSES W/ #5 REBAR EA COURSE- 1/2" OR 5/8" GWB OVER OVER 3/4" FURRING STRIP. GARAGE WALLS TO BE UNINSULATED & UNFINISHED. WALL REINF AS PER NOTE 16.8/GN-1. DOWELS PER NOTE 17.2 GN-1. PROJECT SPECS: A-1 GENERAL NOTES: GN-1 FOOTING PER FOUNDATION PLAN & FOOTING SCHEDLE- REINF PER FOOTING SCHEDULE GRADE AS PER SITE PLAN TYP WALL SECTION SCALE: 1/2"= V-0" SEE ELEVS Y 1/2" OR 5/8" GWB OVER WOOD PE TRUSS BC. GARAGE HOUSE F3 OPTIONAL CJ/EJ MONO & STEP M OPTIONAL CJ/EJ * W ° MONO fill CURB/ RECESS _ ° e ! SOG/FILLICOMPACTION PER l FOUNDATON PLAN AND NOTE 17/GN-1 9 W SHEET INDEX A-1 floor plan A-2 elevs A-3 foundation/ framing A-4 elect, plumb GN-1 general notes PROJECT DESCRIPTION NEW 1 STORY SF RESIDENCE. ZONING INFORMATION: PARCEL ID: 3402-607-0239-000-0 RS-3 (ST LUCIE COUNTY) FLOOD ZONE: X FORMATION: gas: n/a sewage: septic potable water: public AREA CALCULATIONS: conditioned living area 1,991 Sf garage 563 sf front porch 617 sf rear porch 383 sf total building area 3,554 sf conditioned volume 18,915 cf FDOH in St. Lucie County Environmental 'Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTDS C-7-37qvy & Well # Date: IZ/ 247d /l Reviewer! _ DOOR/ LINTEL SCHEDULE DESCRIPTIONACTUAL D1 31 41.7 3-0 8-0 CC 8RF14-1B/1T IS, SWING, GLAZED D2 31.9, -41.7 6-0 8-0 CC 8RF14-1B/1T I D. SWING, GLAZED D3 28 2, -31.5 16-0 8-0 CC 8F16-iB/2T I SECTIONAL OVERHEAD SEE GEN NOTE 26. CC= CASTCRETE WINDOW/ ACTUAL W1 33.4, -44.8 ( ) 3-0 5-2 :• 8-0 LINTEL SCHEDULE TYPE NOTES CC 8F164BAT (2) S. HUNG W2 33.4, -44.8 3-0 5-2 8-0 CC 8F16-18/1T S. HUNG W3 33.4, -44.8 (2) 3-0 5-2 8-0 CC 8F16-1B/1T (2) S. HUNG W4 33.4, -44.8 3-0 5-2 8-0 CC 8F36.1B/1T S. HUNG WS 33.4, -44.8 (2) 3-0 5-2 8-0 CC 8F16-1B/1T (2) S. HUNG EGRESS W6 33.4, -44.8 (2) 3-0 5-2 8-0 CC 8F16-1B/1T (2) S. HUNG EGRESS W7 33.4, -44.8 3-0 4-6 8-0 CC 8F16-1B/1T IS. HUNG W8 33.4, -44.8 3-0 2-0 8-0 CC 81`16ABAT FIXED W9 33.4, -44.8 2-8 5-2 8-0 CC 8F16-1B/1T S. HUNG EGRESS W10 133.4, -44.8 2-8 5-2 8-0 CC 8F16-1B/1T IS. HUNG SEE GEN NOTE 26. CC= CASTCRETE PRODUCT APPROVAL AFFIDAVIT GLASS ITEM TYPE ID,BUILDING DP, PR PRODUCTD, TYPE, MODEL,,,°• , OVERHEAD ALL 31.9, -41.7 36,-44 N/A DAB ANY NOA 20-0107.06 S. SWING, GLAZED ALL 31.9, -41.7 50, 50 IMPACT 16Id Wen ANY FL 16674.2 SWING, GLAZED ALL 31.9,-01.7 50, 50 IMPACT leld Wen ANY FL 16674.4 ADOORD. FIXED ALL 33.4,-44.8 55,55 IMPACT Jeld Wen ANY FL 14088.3 S. HUNG ALL 33.4,-44.8 65,-70 IMPACT Jeld Wen ANY FL 14095.1 S. HUNG ALL 33.41-44.8 65, 70 IMPACT Jeld Wen ANY FL 14095.4 WINDOW IMULUON IALL 144.8 157 1 N/A lJeld Wen I1x3 I FL 11870.1it-clip w/ (4) .25"x1.5' embed ea clip ROOFING UNDERLAYMENT ALL N/A N/A N/A Owens Corning WeatherLock NOA 18-0523.02 self adhered -56.1 geld, - ROOFING METAL ALL 78.8 edge -166 N/A Dynamic Metals 1500 FL 27499.12 clip @ 16" oc/ 4" ends 1. 'ID' as per door & window schedule, or all meaning worst case of all similar items of that type. 2. If building dp are left blank- see door & window schedule or design pressure chart. 3. This affidavit is only to verify product's compliance with wind loads. 4. Unless products are specifically submitted for verification by contractor, they are assumed. S. If glass type is not specified more than 'impact', may use any of the impact glass type in the install instructions to achieve the stated building design pres{Tares. 6. If fasteners is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures. 7. 1 have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wi8d loads and forces specified by current code provisions. ~ )_ 0 v m Qz o S E O U y ma C= c- O f0 C L = 0 C Q M + c. o ? CO CO C4 CO 0 to + �0 C O U M r� C J fis I.L. U. L C) U a a U IL w wr 0 w w O 0 0 w W w U N Z � e ( LLJ 0 C) 0 U c J U Z W U_ a LL o Q } m J LL 0 U) w W iJ 0 N I.L 0 Z W 4- N a J Z (ci ru a W QN F W i- o �z 0 zz z 2 w t7 z �d 0 y z z O w 0 v; u� 0 z LU O U Q 0 floor plan 8/27/21 SHEE.■T A IJ• F C%S P. L/Ee,�PY 1 AR97108 SCALE: 1/4"= V-0" RIGHT ELEVATION SCALE: 3/16"= 1'-0" LEFT ELEVATION SCALE: 3/16"= T-0" F11 El FRONT ELEVATION SCALE: 3/16"= 1'-0" E ++ cc r. 0 U U NC) C= 0Ea �Q 7 + Cp V; En_ C 7 m N 04 N M N p C� ; p — N = c0r-- 'y y N N d A + r Y C r co LL LL U U U W O K a U LL U W N N_ S 0 LL 0 a O w w ZO 6 ❑ W J >O W W ❑ W V C\l Z000/�0 0) U W 0 Mst V � J Z W LL w a LLJ Z J m J LL L W LL W G( O u- O Z w w w a Z J C� ' z C 5 � W m~ 0 W I— w ZU O Z_ W W z❑ Q N N Z C7 N W NQ❑ W F Z W O U Iu Q O elevs 8/27/21 SHEET A-2 -J. os P. LlFe� AR97108 KFp. V '''lv;�� _ � REAR ELEVATION SCALE: 3/16"= 1'-0" ROOF PLAN SCALE:NTS FOOTING SCHEDULE CNECTION (CXN) SCHEDULE ON ACTUAL CONNECTED�CTUAL ELEMENTS REACTIONr UPLIFT GRAVITY CONNECTOR ID AIltrussto on eam locations uno truss CO-1 valley truss to ea supporting truss truss CO-6 or CO-7 truss GR2 truss CO-8 truss GRA 18,27 truss CO-9 truss GRB 18 truss CO-9 truss GRBl truss CO-9 1. Connector ID references the connector (CO) schedule. 2. All loads are checked by architect, loads left blank were checked but are not required to be listed. 3. Actual loads listed in this schedule are worst case, actual may be lower than listed but never higher. 4. If 'connected elements' contains 'truss', reference loads in truss package. If no reaction points specified use connector for all nesessary points. CONNECTOR(CO)SCHEDULE ALLOW ALLOW ID CONNECTED ELEMENTS UPLIFT GRAVITY QTY MFR MODEL FASTENERS CO-1 see CXN sched 1810 1 Simpson HETA 20 To truss w/ (9) 10d x 1.5" CO-2 see CXN sched 2035 2 Simpson HETA 20 To single ply truss w/ (10) 10d x 1.5" CO-3 see CXN sched 2500 2 Simpson HETA 20 To multi ply truss w/ (12) 16d To conc w (4) .25' x 2.25" tapcon. To truss w/ (10) CO-4 missed or misplaced co-1 1175 1 Simpson HTSM20 30d x 1.5" To conc w (4) .25' x 2.25" tapcon. To truss w/ (10) CO-5 missed or misplaced co-1 2350 2 Simpson HTSM20 SOd x 1.5" To valley truss be w (3) 10d x 1.5". To supporting CO-6 see CXN sched 370 1 Simpson VTCR truss tc w/ (4) 10d. To valley truss be w (4) 10d x 1.5". To supporting CO-7 see CXN sched 500 1 Simpson MST12 truss tc w/ (4) 10d x 1.5. To truss w (16) 10d. To conc w (2) 5 8" TR epoxied CO-8 see CXN sched 10980 1 Simpson HGT-2 12" into bond beam. To truss w (22) 10d nails. To conc w 5 8" TR epoxied CO-9 see CXN sched 1 39651 11 Simpson IMGT 12" into bond beam 1. Refer to connection CXN schedule for connector locations. 2. 'CITY' referes to the number of connectors used per per ea connection (connected elements). If qty left blank, refer to drawings. CAST-CRETE LINTEL DIAGRAM r F = FILLED WITH GROUT / U = UNFILLED 1 r QUANTITY OF #5 FIELD ADDED REBAR AT BOTTOM OF U-LINTEL CAVITY FOR GRAVITY LOAD 8F16-1 B/1 T NOMINALWIDTH- QUANTITY OF#6 FIELD ADDED REBAR AT TOP OF NOMINAL HEIGHT COMPOSITE U-LINTEL FOR UPLIFT LOAD #5 FIELD ADDED REBAR AT TOP OF COMPOSITE U - LINTEL MIN. (1) REQ'D 1.112" CLEAR w FIELD PLACED C.M.U. x J a i m i GROUT 05 FIELD ADDED REBAR AT # BOTTOM OF U-LINTEL CAVITY BOTTOM REINFORCING 7-6/S"ACTUAL PROVIDED IN U-LINTEL 8"NOMINAL WIDTH (SEE REINFORCING SCHEDULE) LINTEL AS PER WINDOW/DOOR SCHEDULE DOOR & WINDOW BUCKAS PER GEN NOTE 26.2 FLASHING AND SEALING AS PER GEN NOTE 26.7 WINDOW FRAME W/ FLANGE, ATTACH TO MASONRY/CONC AS PER MFR SPECS HiWind MASONRY SILL BY CASTCRETE EXT "1i:`; INT TYP OPENING BUCK DETAIL SCALE: 1"= V-0" HORIZ BOND BEAM STEEL CONT BAR TO MATCH HORIZ OR CORNER BARS W/ 25" LAP MIN COURSE/STEEL OTY/SIZE PER SPECS, USE BEAM OR KNCKOUT BLOCK °"rift i r HORIZ BOND BEAM STEEL SECTION ELEVATION CHANGE- ELEVATION VIEW CORNER BAR W/ 25" LAP MIN ) °s TO MATCH HORIZ SIZE, CITY I> HORIZ STEEL Ip INTERSECTION. PLAN VIEW CORNER- PLAN VIEW BOND BEAM/ LINTEL CONTINUITY DETAILS SCALE: NTS V (D p E O U E c. T _ 0 .. (D C L 0vNC coen CL a2m"1 Q LID E� C.p C_ 3 C C N �@ 7 04 CO r0IM= rn C> CV Y G V r f` LL LL r-- U U W O ac Q. U LL U W Q. _m x z 0 LL ❑ w a 0 J W W O Z Q w J O W W w U N Z 00 TT 0) U W 0_ M V U) J Q Z W LLLU a n/ LL z o 0 j ~ m MMMMM LL L W ❑ LL W Q o OC LL o 1W Z W a� w 0. a Z J w W _ Z w VJ N W I- Z O NZ_ F Z W W iZQgq� 4 ❑ N a z z O W w ❑ JJ Q F- Z W O U W F- Q foundation/ framing 8/27/21 SHEET A=3 O F. F� Obi y' NCIS P. L/Fe % 4 <OP AR97108 FOUNDATION/SLAB PLAN SCALE: 1/4"= V-0" N W E2 W I I I I I I I I I L5- - I I I I I I I I LS I I I I I I I I L5 1 i i i I i I I I I I I I i I I I I I I I I I I I I L5 I I I I I I I I I I LS I I I I I I I I I LS I I I I I I I LS E5 E2 I I I I I I I I I I I I I I I I I I I 1 I I i i I i I I I I I I i I I I LS I I I I I I L5 I I I I I I I L5 I i I I I I i ❑ I pJj I I I W I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I 1 I I I I I I I L5 I ^ L5 LS - LS E2 DETACHED GARAGE/SHED ELECT PLAN SCALE: 3/16"= T-0" SK 1.5" AAV DWV PLUMBING PLAN SCALE: 1/8"= T-0" E2 I I l I I I 1 I i I I I I I I I I I I I I I E2 ES L5 I I I I I I i 1 I II I I 1 I 1 I I LS w E2 J 2" E1 E2 E3 E4 E5 E6 E7 E8 E- L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 S EX EXL FL FA JB SD TV L 171 L12 r r l r r r r r L4 -- -; -- -- 0 rQ ` l W \ i I I I \ r I 1 L1 ` r b E-CU E5 L1 L1 L1 W W L1 L1 E1 I I I I I I I I I I I 1 ELECT PLAN NOTES: 1. SEE GENERAL NOTES 27 ON GN-1. 2. GFI PER PLAN & GEN NOTE 27.4. INCLUDING ALL RECEPTACLES IN LAUNDRY ROOM, WASHER, DISHWASHER, GARAGE DOOR OPENER. 3. PROVIDE DISCONNECTS FOR WATE'--R HEATER, CU, AHU 4, ALL 120 VOLT BRANCH CIRCUITS SL)pPLYING RECEPTACLES INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT (NEC 210.12(8)). L1--------------- L1 ----------------- U1-----------------L1 I I I I I I _> FL L1 L1-------------- L1----------------L1 LU ` N W �\ W FA Et egg W w C5 w o3 w w `x ww E2 L1 L1 E1 - _ _ �' I I E1 -4- - - - - - - - - - -LV L1 W / SD E1 LU E-RG FA E1 I I W w w IT SO I // m L5 ^^ �- L1 / i L1 i E2 L1 L--- LB ; E1 I I I SID LU L9 --I-; ------------------------- E1 I `� �\ `—--- — — ---— L1 \` L1 \ E2 LS \ l Lu / I I I u Owl\ W E1 \ L1 ---- L1--------------- r \ r L1 L1 /' - ------ 9,---_ L12 I I Td I I _ j�I EX SD E2 W I E1 W wOp i w3 SO /�\ E1 FF7= E1 I i FA I I \ \ I I I 1 I I \ I FA I L5 I E1 1 I i E1 I I I I I L9 E2 I L1\ ' L1- ---- i L1 E1 L1-------- I L1 E1 W w W Lu J II II W I TALL LII L1=_--------------L1-------------------------L1 --------------------- L1-------------------- L1 L11 .ECT PLAN LEGEND ELECT PLAN SCALE: 3/16"= V-0" 120V DUPLEX RECEPTACLE 120V GFCI DUPLEX RECEPTACLE 120V RECEPTACLE recessed for tv 120V GFCI DUPLEX RECEPTACLE- soffit 120V GFCI DUPLEX RECEPTACLE w/ water protected box 240V RECEPTACLE- gene backfeed w/ panel lockout 120V RECEPTACLE- floor PANEL FOR RV: 120V- 20A GFI, 240V- 30A & 50A ELECTRIC FOR LABLED APPLIANCE RECESSED CAN LIGHT FLUSH MOUNT CLG LIGHT FLUSH LED STRIP LIGHT VANITY WALL LIGHT SHOP LIGHT CHANDELIER LIGHT PENDANT LIGHT UNDER CABINET LIGHT EXTERIOR WALL SCONCE WALL MOUNT READING LIGHT EXTERIOR MOTION DETECTOR LIGHT RECESSED CAN LIGHT- wet location RECESSED CAN LIGHT- exterior soffit LIGHT SWITCH EXHAUST FAN- vent to roof if vented soffit, soffit if unvented EXHAUST FAN WITH LIGHT- vent to roof if vented soffit, soffit if unvanted FAN/ LIGHT COMBO FAN W/O LIGHT JUNCTION BOX SMOKE/CO2 DETECTOR- interconnected, hardwired w/battery TELEVISION CABLE NEW METER •Qm m0 VO N U N J U J aQ nQ nQ �o do 30 GEC TO CWP, UFER, INTERSYSTEM NEW UNDERGROUND WIRE SIZE BY ELECTRICAL CONTRACTOR ELECTRICAL RISER DIAGRAM SCALE: N.T.S. a3i c Electric Load Calculation 220.12 General Lighting Load L11 E5 L 171 3 valfe of floor area, Including unused space adaptable for future use. Floor Area= 1991 to 5,973 va Basement Floor Area = ft° va 220.52(A) Small Appliance Load 1500 va for each 20 amp branch circuit required per 210.1(C)(1) in EACH kitchen, pantry, breakfast room, dining room, or similar areas. # of Small Appliance Branch Circuits= '1500 va= 3,000 va 220.52(8) Laundry Load # of Laundry Branch Circuits= "1500 va= 1,500 va Total General Lighting & Appliance Load- 10,473 va 220.42 Lighting Load Feeder Demand Factors 220.54 220.55 220.61 First 3000 or less at t00% 3,000 ve From 3001 to 12o,000 at 35% 2,616 va Remainder over 12o,000 at 2S% - va Total Lighting Demand Loatl= 5,616 va Electric Clothes Dryers city I Electric Dryer#1 5.00 kw 5,000 w Ory o Electric Dryer #21 kw w Electric Cooking -Ranges, Stove Tops and Wall Wens Ory OtY kw Otykw Electric Cooking Demand Load= 10,400 w Fixed Electric Space Heating Loads or Air Conditioning Load: Fixed Electric Space Heat#a 10.0 kw AC#i/Geo 16 SEER 4Ton 5.1 kva Fixed Electric Space Heat#a kw AC#a/Geo kva Fixed Electric Space Heat#3 kw AC#3/Geo kva Fixed Electric Space Heat #4 kw AC#4/Geo kva Fixed Electric Space Heat#5 kw AC#5/Geo kva Total Heat & AC Load = 15,078 va 220.14 Appliance load--Dweliing Units ON Deserintinn vslumea\ 0 1 Dishwasher 1,2W 1 Refrigerator 1,440 i Microwave I'M 0 0 0 1 Electric Range Nameplate 8.00 1 Wall Oven Nameplate 8.00 0 QN Description vaiwags) Total Connected Appliance Load = 31,220 va 220.53 Appliance load -Dwelling Units Total Appliance Demand Loatl= 23,415 va 220.50 Motor Loads @120 Volts OtY Description va(watts) Description vs(watts) i 3/4hpPol*Spa Pump 563 o 112hpG "Iage DiBposa 375 _ 0 i i/2hpG. rDOorOpener 375 0 0 0 Total Motor Load = 1,313 va 430.24 Several Motors or a Motors) and Other Load($) 25%of Largest Motor Load = 141 va Total Motor Demand Load= IA54 va TOTAL CALCULATED DEMAND LOAD In Volt-amperes = 60,962 va TOTAL CALCULATED DEMAND LOAD In AMPS ,@1201240V iph3W - 254 amps EXISTING §ERVICE SRE NEW AMPS MINIMUM§ERVICE SRE 400 AMPS SERVICE SIZE REQUESTED= 400 amps 3 C r O O = rn LB 0 p) C E -- � o Leo tJi. U w K a U U W N N 0 w 0 w 0 ❑ a w J 0 w W❑ U � Z � W _ M V (/l J G Z W / `?- � N01S P. LIFe _. AR97108 , Note: Electrical contractorto verify accuracy and completenessof load calculation. HVAC specs are esitimates only BASIS OF STRUCTURAL DESIGN: SOIL BEARING: 2500 psf (assumed) WIND: 160mph (ult), risk cat 2, exp C, wind borne debri region, .18 enclosed design FROST DEPTH: 12" THE DESIGN APPROACH FOR MASONRY ROLLED STEEL AND LIGHT WEIGHT STRUCTURAL STEEL IS WORKING STRESS DESIGN. THE DESIGN APPROACH FOR REINFORCED CONCRETE IS ULTIMATE STRENGTH DESIGN, THE DESIGN SERVICE LOADS ARE AS FOLLOWS: ROOF LIVE LOAD 20 PSF(slope<4:12), 15 PSF(slope24:12) ROOF DEAD LOAD 10 PSF TC (shingles, metal, modified bitumen) ROOF WIND LOAD (SEE DRAWINGS) CEILING DEAD LOAD 10 PSF BC WALL WIND LOADS (SEE DRAWINGS) FLOORDEAD LOADS D OAD 15 PSF TC 5 PSF BC FLOOR LIVE LOADS SEE BELOW FLOOR LIVE LOADS: Uninhabitable attics without storage 10 psf Uninhabitable attics with limited storage 20 psf Habitable attics and attics served with fixed stairs 30 psf Balconies (exterior) and decks 40 psf Fire escapes 40 psf Guardrails and handrails 200 lb Guardrail in -fill components 50 pit Passenger vehicle garages 50 psf Rooms other than sleeping room 40 psf Sleeping rooms 30 psf Stairs 40 psf WIND PRESSUR COMPONENT AND CLADDING LOADS... FROM TABLE FBC R301.2(2) ZONE EFFECTIVE WIND AREA (SF) 160 1 10.0 24.9 -56.1 1 20.0 21.5 -56.1 1 50.0 16.9 -43.3 1 100.0 13.6 -33.4 2r 10.0 24.9 -73.1 Hip Roof 2r 20.0 21.5 -65.8 to de 720 deg 2r 50.0 16.9 -56.3 2r 100.0 13.6 -49.0 2e, 3 10.0 24.9 -78.8 2e, 3 20.0 21.5 -70.9 2e, 3 50.0 16.9 -60.4 2e, 3 100.0 13.6 -52.4 Wall 4 10.0 33.4 -36.3 4 20.0 31.9 -34.7 4 50.0 30.0 -32.8 4 100.0 28.4 -31.2 4 500.0 24.9 -27.7 5 10.0 33.4 -44.8 5 20.0 31.9 -41.7 5 50.0 30.0 -37.8 5 100.0 28.4 -34.7 5 1 500.0 1 24.9 -27.7 Garage Door 9'xT I 1 29.4 -33.3 16'x7' I 1 28.2 -31.5 1.21 adjustment factor used m o.sn y� f - _1 r - c , I a I I I I I I 101 0 I I too I I I I e.l 1 1 G.WU-1- 1 � - - - J I - - J I MAN Gable and Flat R�oaN_1y_e:55_7°_.L__�_ _� I I 1 � , _, 1 J M , GLOM and Flat ROOK 7" <e S 45" PLIVN ft Roo6 T < a S 45" walls a -' T_�_ III 1 �%.anan e h a-'-- F1 FI 1, My I GENERAL NOTES- residential 1. CODE COMPLIANCE: 16. CONCRETE MASONRY: 23. PE TRUSSES: ABBREVIATIONS: 1.1. This project was designed under t following s. T p ! g u e he o owing code he construction documents cannot reference all of the codes require for the 16.1. CMU DESIGNED AND TO BE IN ACCORDANCE ACI 530-13lASCE 5-13frMS 402-13, "BUILDING CODE REQ FOR 23.1. CONFIGURATION FIELD VERIFY WITH ARCHITECT EXACT LOCATION AND C N IGURATION BEFORE MODIFYING EXISTING construction of this building. By submitting these construction documents for permit or commencing work, the contractor, hereby MASONRY STRUCTURES", "COMMENTARY ON BUILDING REQ FOR MASONRY STRUCTURES". TRUSSES. DO NOT CUT ANY FRAMING MEMBERS OR TRUSSES WITHOUT EXPRESS WRITTEN AUTHORITY AB ANCHOR BOLT agrees to comply with all local, state, and federal regulations having jurisdiction over this project, and to comply with all governing 16.2. MASONRY STRENGTH If DESIGN) UNO: FROM THE ENGINEERAND ARCHITECT. A/C AIR CONDITIONER codes, including but not limited to, the most current editions as adopted by the state of Florida, of the following: -BLOCK STRENGTH = 1900, ASTM C90 23.2. FIELD VERIFY DIMENSIONS OF NEW PRE-ENGINEERED TRUSSES PRIOR TO CONSTRUCTING. AHU AIR HANDLING UNIT -2020 FBC: RESIDENTIAL, 7th ad -2017 NATIONAL ELECTRIC CODE -MORTAR STRENGTH = 1800, TYPE S 23.3. CONTRACTOR TO SUBMIT THE TRUSS ENGINEERING TO ARCHITECT TO REVIEW FOR ADHERENCE WITH AT ACOUSTICAL TILE -2020 FBC: ENERGY CONSERVATION, 7th ed -ASCE 7-16 -GROUT STRENGTH = 2000 DRAWINGS PRIOR TO CONSTRUCTION. ARCHITECTS SEAL WILL NOT BE APPLIED. 16.3. GROUT SHALL HAVE A SLUMP OF 8 TO 11 INCHES, BE IN CONFORMANCE WITH ASTM C 476-02 AND ATTAIN A 23.4. TRUSS CONFIGURATION DRAWN ARE SCHEMATIC ONLY, HOWEVER THE SUPPORTING STRUCTURE HAS B.M. BENCH MARK 2. ALL GENERAL NOTES COMPRESSIVE STRENGTH OF 3000 PSI. GROUT SHALL CONFORM TO REQUIREMENTS OF FLBC STANDARDS. BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL BM BEAM 2.1. THE FOLLOWING SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO SUPPLEMENT THE DRAWINGS. IN CASE OF USE SUFFICIENT WATER FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT FINAL LAYOUT MY MFR. EXACT TRUSS WEB, CHORD SIZES AND LAYOUTARE TO BE DETERMINED BY THE BC BOTTOM CHORD CONFLICT NOTIFY ARCHITECT. THESE DRAWINGS IN CONJUNCTION H T WITH OTHER SUBMITTALS, REPORTS, OR E SEGREGATION. ALL CELLS IN CONCRETE BLOCKS CONTAINING REINFORCING SHALL 8E FILLED SOLID WITH MFR. TRUSS MFR TO DESIGN ANY PERMANENT BRACING REQUIRED FOR STABILITY. BILK BLOCK WRITTEN INSTRUCTIONS BYARCHITECT OR CONSULTANTS, SHALL BE CONSIDERED THE COMPLETE CONSTRUCTION GROUT. ALL MASONRY BELOW FINISHED FLOOR OR GRADE SHALL BE GROUTED SOLID. HOLD GROUT 23.5. ALL TRUSSES FURNISHED SHALL BE SUPPLIED WITH SIGNED AND SEALED TRUSS DIAGRAMS PROVIDING g0 BY OWNER DOCUMENTS. DOWN 1-1/2" BELOW TOP OF BLOCK AT GROUT LIFT JOINTS AND AT CONCRETE PLACED OVER MASONRY. THE MFR'S TRUSS SPECIFIC REQUIREMENTS FOR BRACING AND LATERAL MOVEMENT. ALL TRUSS-TO- BOTT BOTTOM 2.2. THE FOLLOWING GENERAL & SPECIFIC NOTES SHALL APPLY EQUALLY TO ALL CONTRACTORS, SUBCONTRACTORS, 16.4. CONCRETE MASONRY UNITS SHALL BE PLUMB, TRUE TO LINE, WITH LEVEL COURSES ACCURATELY SPACED TRUSS CONNECTORS TO BE SUPPLIED BY THE TRUSS MFR. VERIFY THAT THE CAPACITY OF THE TRUSS BP BOTTOM PLATE AND SUPPLIERS ENGAGED IN EXECUTION OF WORK ON THESE PLANS. AND BUILT TO THE THICKNESS AND IN A RUNNING BOND AS INDICATED AND CONFORMING TO THE ANCHORS CALLED OUT ON THE CONSTRUCTION DRAWINGS MEET OR EXCEED THE UPLIFT VALUES ON 2.3. GENERAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF DRAWINGS AND ADDENDUM'S TO ALL TOLERANCES SPECIFIED IN ACI 531.1 AND 530.1. THE TRUSS ENGINEERING. ANY TRUSS ANCHORS CALLED OUT THATARE OF INSUFFICIENT CAPACITY CJ CONTROL CONSTRUCTION JOINT (CONSTRUCTION) SUBCONTRACTORS ON THE JOB AND COORDINATE THEIR WORK. ANY DISCREPANCIESAND/OR CONFLICTS IN THE E 16.5. REINFORCING BA E FORC NG BARS SHALL BE PLACED IN THE MIDDLE OF THE CELLS UNLESS NOTED OTHERWISE, AND SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR SUBSTITUTION. CL CENTER LINE DRAWINGS SHALL BE NOTIFIED TO THE ARCHITECT BEFORE PROCEEDING WITH ANY INSTALLATION. FAILURE TO DO TIED OR OTHERWISE SECURELY SUPPORTED AT THE TOP AND BOTTOM TO ENSURE THATTHE BAR DOES 23.6. BRACE BOTTOM CHORD AS PER MFR SPECS, IF NOT PROVIDED, PROVIDE CONTINUOUS 'RAT RUN' CLG CEILING SO WILL BE THE ENTIRE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ANY COSTS ARISING TO CORRECT THE NOT MOVE DURING GROUTING. LATERAL BRACE PERPENDICULAR TO BC 2x4 @ 12' OC (2) 12d NAILS EA BC. CLR CLEAR DISCREPANCY AND/OR CONFLICT SHALL BE BORNE BY THE RESPONSIBLE PARTY. 16.6. MORTAR DROPPINGS AND OTHER DEBRIS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE GROUTED. 23.7. PREFABRICATED WOOD TRUSSES, JOISTS, AND GIRDER TRUSSES SHALL BE DESIGNED TO SUPPORT CMU CONCRETE MASONRY UNIT 2.4. NO DEVIATION OF THE APPROVED SET OF DRAWINGS WILL BE MADE IN THE FIELD WITHOUT THE EXPRESSED 16.7. CONTROL JOINTS SHALL BE PROVIDED IN ACCORDANCE WITH THE LOCATIONS AND DETAILS SHOWN ON THEIR SELF -WEIGHT, PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. INCLUDING, BUT NOT LIMITED CO CONNECTOR WRITTEN CONSENT OF THE ARCHITECTAND BUILDING OFFICIAL. IN SUCH CASE THE ARCHITECT SHALL PREPARE A THE DRAWINGS. CONTROL JOINTS SHALL NOT EXTEND THROUGH THE TOP BOND BEAM COURSE. THE TO, WALLS EITHER PARALLEL OR PERPENDICULAR TO THE SPAN, ALL MECHANICAL AND OTHER COL COLUMN REVISION IN ACCORDANCE WITH THE CHANGE. APPROVAL FROM THE BUILDING OFFICIAL SHALL BE OBTAINED BY THE JOINTS ON BOTH SIDES OF THE WALL SHALL BE SEALED AND TOOLED SMOOTH. EQUIPMENT, AND SHALL DESIGNED TO RESISTALL DRAG FORCES, SHEARWALL UPLIFT AND DOWNWARD CONIC CONCRETE CONTRACTOR BEFORE PROCEEDING WITH ANY WORK. 16.8. WALL REINFORCEMENT: VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SPECIFIED LOADS, AND OTHER SPECIAL LOADS NOTED ON STRUCTURAL, MECHANICAL, PLUMBING, OR CONT CONTINUOUS ON THE DRAWINGS. DESPITE IF SHOWN ON DRAWINGS- PLACE VERTICAL REINFORCING BARS AT ARCHITECTURAL DRAWINGS OR CALCULATIONS. MINIMUM ALLOWABLE SHEAR SHALL BE 95 PSI, CU CONDENSING UNIT OR COPPER 3. ARCHITECT & CONTRACTOR RELATIONSHIP CORNERS, EA CELL WITHIN 16" OF CORNER, JAMBS OF OPENINGS, EA CELL WITHIN 16" OF JAMBS FOR BRIDGING SIZE AND SPACING SHALL BE AS DESIGNATED BY TRUSS MFR UNLESS NOTES OTHERWISE. CW COLD WATER 3.1. UNLESS CONTRACTED DIRECTLY BY CONTRACTOR, THE ARCHITECT AND CONTRACTOR ARE NOT IN A CONTRACTUAL OPENINGS WIDER THAN 12% BELOW BEAM BEARING, BELOW GIRDER TRUSS BEARING, AND IN WALLS AS CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ERECTION DRAWINGS AND DESIGN CALCULATIONS CXN CONNECTION RELATIONSHIP, THE ARCHITECT IS AN AGENT OF THE OWNER. BY SUBMITTING THESE CONSTRUCTION DOCUMENTS INDICATED ON THE DRAWINGS. IF NOT SPECIFIED IN TEXT ON DRAWINGS USE #5 @ 48" OC. WALL SEALED BYA REGISTERED ENGINEER. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED FOR PERMIT, THE CONTRACTOR ACKNOWLEDGES THAT THEY ARE COMPETENT, UNDERSTAND THE DOCUMENTS, AND REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICBO APPROVAL. THE MFR SHALL DESIGN D NAIL SIZE (PENNY) ARE BOUND BY THE TERMS OF THE DOCUMENTS. IF THE CONTRACTOR VEERS FROM THESE PLANS, THEY ARE SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. 8" TOLERANCE ALLOWED CONNECTION OF TRUSS REQUIRING PREFABRICATED HARDWARE HANGER OR OTHER. DF DRINKING FOUNTAIN ACCEPTING LIABILITY THAT MAY ARISE DUE TO CHANGES. ARCHITECT IS NOT LIABLE FOR THE CONTRACTOR'S FOR WALL REINF SPACING. SEE DOWEL NOTE 17.2 BELOW. 23.8. FABRICATOR TO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE DIA DIAMETER INCOMPETENCY TO UNDERSTAND THE CONSTRUCTION DOCUMENTS. IT IS NOT THE ARCHITECT'S ERROR OR 16.9. REINFORCED MASONRY LINTELS SUCH AS CAST CRETE TO BE INSTALLED AS PER MFR INSTRUCTIONS. AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER). SPECIALTY ENGINEER MAY SUBMIT DIM DIMENSION OMISSION IF THE ARCHITECT DOES NOT SPECIFY/REFERENCE SOMETHING THAT IS REQUIRED BY THE CODES LINTELS TO HAVE 4" MINIMUM BEARING. CONTINUOUS REINF ACROSS COLUMNS. IF SPECIFIED, CA LINTEL PREFERRED CONNECTION AND OTHER DETAILS IF DIFFERENT FROM SAME ON DRAWINGS FOR DISP DISPOSAL MENTIONED, THE CONTRACTOR AND SUBS ARE REQUIRED TO UNDERSTAND AND ADHERE THE BLDG CODES NO LENGTH IS +/- AS LONG AS MIN ERG IS MET. DOORIWINDOW LINTELS CAN BE DEEPER(TALLER) THAN APPROVAL. DN DOWN DIFFERENT THAN THE ARCHITECT. SPECIFIED BUT NOT SHORTER. DR DRYER 16.10. UNO HORIZ JOINT REINFORCEMENT @ 16" OC IN MASONRY WALLS IS SUGGESTED BUT NOT REQUIRED TO 24. CONNECTORS/FASTENERS: DTL DETAIL 4. WORKMANSHIP: CONTROL CRACKING. 24.1. CONNECTORS BY SIMPSON OR APPROVED SIMILAR TO BE HDG OR ZMAX COATED IF UNEXPOSED TO DW DRIVEWAY 4.1. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY CRAFTSMEN SKILLED IN THEIR 16.11, BOND/TIE BEAMS/LINTELS- CONTINUE REINFORCING BARS CONT (UNINTERRUPTED) AROUND ALL WEATHERAND TO BE STAINLESS STEEL IF EXPOSED TO WEATHER UPON COMPLETION. RESPECTIVE TRADES. CORNERS, OVER OPENINGS, ACROSS WALL INTERSECTIONS, THROUGH TIE COLUMNS, AND UP/DOWN AT 24.2. UPLIFT CONNECTORS MAY BE SUBSTITUTED WITH CONNECTORS WITH Z THE DOCUMENTED UPLIFT 'E' EXISTING CHANGES IN BOND BEAM ELEVATION. VALUE IS Z SPECIFIED CONNECTOR. UNLESS SPECIFIED UPLIFT CONNECTORS ARE NOT REQUIRED ON EA EACH 5. COORDINATION: 16.12. ALTERNATE WINDOW SILL: 4"H MIN x 8"W CAST CONC WI (1) # 5 EXTENDED 4" INTO FILLED JAMB CELLS. LOADBEARING WALLS THATARE NOT SUBJECT TO UPLIFT OR SHEAR. SPACE NAILS AT STRAPS AS TO EJ EXPANSION JOINT 5.1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF WORK FOR ALL TRADES. NOT SPLIT WOOD, USE MINIMUM NAIL OTY REQUIRED BY MFR. IF MULTIPLE FASTENER OPTIONS USE EL BUILDING ELEVATION 5.2. A DRAWING MAY INADVERTENTLY OMIT SOME RELATED ITEM FROM ANOTHER DRAWING. THIS DOES NOT MEAN THAT 17. FOUNDATIONS: EITHER UNLESS SPECIFIED BY ARCHITECT. ELECT ELECTRICAL THE SECONDARILY OMITTED ITEM IS NOT REQUIRED IN SO FARAS IT AFFECTS THE TRADES. ALL TRADES SHALL 17.1. BUILDING AREA TO BE STRIPPED/GRUBBED OF SURFACE DEBRIS/VEGITATION. FILL TO BE CLEAN ELEV ELEVATOR OR ELEVATION INCLUDE EVERYTHING NECESSARY FORA COMPLETE AND PROPERLY FUNCTIONING CODE - ACCEPTABLE PROJECT, GRANULAR & UNIFORMLY COMPACTED TO 95% DENSITY (ASTM D 1557) AND MEASURED IN 12" LIFTS. AT 26. EXTERIOR DOORS AND WINDOWS: EW EACH WAY UNLESS CERTAIN ITEMS ARE SPECIFICALLY INDICATED AS BEING PROVIDED BY OTHERS AS "NIC" (NOT IN CONTRACT). DISCRETION OF CONTRACTOR OR BLDG INSPECTOR, ARCHITECT RECOMENDS SOIL TO BE TESTED BY 26.1. INSTALL OVERHEAD DOORS (INCLUDING BUCKS), EXTERIOR DOORS, AND WINDOWS AS PER MFR'S EWC ELECTRIC WATER COOLER GEOTECH ENGINEER TO ENSURE MINIMUM SOIL BEARING PRESSURE CAPACITY & RECOMEND SITE PREP. SPECIFICATION/ PRODUCT APPROVAL. EWH ELECTRIC WATER HEATER 7. CONDITIONS NOT DETAILED: 17.2. DOWEL VERTICAL REINFORCING BARS OUT OF THE FOUNDATION OR STRUCTURE BELOW WITH BARS OF 26.2. PT 1x BUCK: ATTACH TO MASONRY/CONC W/ADHESIVE & RECESSED 3/16"x2" MIN TAPCON OR 6D CASE EXP EXPOSED 7.1. CONSTRUCTION DOCUMENTS CANNOT DETAIL EVERY CONDITION OR INSTRUCT THE CONTRACTOR ON HOW TO THE SAME SIZE AND SPACING OF WALL ABOVE. THERE SHALL BE A DOWEL FOR EACH VERTICAL HARD NAILS OR T NAILS @ 12"W END. PT 2x BUCK: ATTACH TO MASONRYICONC W/ADHESIVE & EXT EXTERIOR PERFORM THE WORK. EVERY CONNECTION, CORNER, FLASHING, ETC. MUST BE RESOLVED. NOTIFY ARCHITECT IF A REINFORCING BAR. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. RECESSED 1/4"x3 1/4" MIN TAPCON @ 12"A" END. EXTG EXISTING CONDITION NEED ADDITIONAL DIRECTION OR DETAIL. ARCHITECT IS NOT LIABLE FOR WORK THAT IS NOT S For #5: MINIMUM 30"LAP W 1 " U LA / 0 HOOK UNO. SEE WALL REINFORCEMENT NOTE 16.8 ABOVE. FOR MISSED 26.3. MIN OVERHEAD DOOR BUCK: 2x6 @SIDES TO FILLED CELL W/ WEDGE ANCHOR @ 24" OC MIN, 12" FROM DETAILED/SPECIFIED BY ARCHITECT. IF DRAWINGS HAVE DETAILED SPECIFICATION FOR A CERTAIN PRODUCT, EMBEDDED DOWEL, EPDXY EMBED W/ 1/8" OVERSIZED HOLE DIA., 6" EMBED W/ CLEAN HOLE. ENDS. WEDGE ANCHOR TO BE 1l2" x 6" W/ 2" x 1/8" WASHER. 2x6 @ TOP TO LINTEL W/ 1/4" x 2.75" F7 FOOTING #1 CONTRACTOR MAY REQUEST SUBSTITUTION APPROVAL BY ARCHITECT. IF DRAWINGS HAVE GENERIC 17.3. BUILDING SLABS -ON -GRADE TO BE REINFORCED WITH 6x6 10110 WWF MIN WITH MESH UP CHAIRS OVER 6- TAPCONS STAG @ 24- OC. FA FASTENER SPECIFICATION CONTRACTOR IS FREE TO USE ANY PRODUCT THAT MEETS WHAT IS SPECIFIED WITHOUT APPROVAL MIL MINIMUM POLYETHYLENE FILM VAPOR RETARDER OVER TERMITE TREATED COMPACTED GRADE UNO. 26.4. CONTRACTOR TO VERIFY THE FOLLOWING WITH MFR/SUPPLIER PRIOR TO CONSTRUCTION: FD FIELD (FLOOR) DRAIN BYARCHITECT. SUGGESTION TO PROVIDE DIAGONAL 36" #4 REBAR ATALL INSIDE'REENTRANT CORNERS. -ROUGH OPENING DIMS, EGRESS COMPLIANCE (FBC R310), SAFETY GLASS COMPLIANCE (FBC R308.4) FE FIRE EXTINGUISHER 17.4. CONTINUOUS FOOTINGS, STEM OR MONOLITHIC, TO BE REINFORCED CONTINUOUS, WITH LAPS AS PER 26.5. CONTRACTOR TO FIELD VERIFY OPENINGS BEFORE ORDERING DOORS/WINDOWS. FF FINISH FLOOR S. VERIFY SITE INFORMATION: STATED DEVELOPMENT LENGTH IF NOTED OR 48x BAR DIAMETER MIN UNO. 30" MIN CORNERS BARS TO 26.6. DOORS BETWEEN GARAGE & RESIDENCE TO BE 20 MINUTE FIRE RATED OR 1-3/8" THICK SOLID WOOD AS FIN FINISH 8.1. CONTRACTOR IS TO VERIFY ALL SITE INFORMATION AND ASSUMPTIONS, ESPECIALLY SUBTERRANEAN CONCEALED MATCH LONGITUDINAL REBAR. PER FBC R 302.5.1. FLR FLOOR CONDITIONS INVOLVING HIDDEN UTILITIES AND SOIL CONDITIONS. SHOULD ANY CONDITIONS AFFECTING THE WORK 17.5. SUGGESTION TO PROVIDE A 4-INCH MEDIUM TO COARSE SAND OR GRAVEL COMPACTED DRAINAGE FILL 26.7. FLASHING AS PER FBC R703.4 AND REFERENCED FMA/AAMA DOCUMENTS. FP FIRE PROTECTION BE DISCOVERED BY THE CONTRACTOR, HE IS TO NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VERIFY BELOW ALL INTERIOR SLABS -ON -GRADE. 26.8. GLASS TO HAVE: LOW-E, U-FACTOR 5 0.4, SHGC 5 0.25 EPS EXPANDED POLYSTYRENE THAT EXISTING SOILS MEET THE MINIMUM CAPACITY PER THE STRUCTURAL DESIGN. 17.6. SOILAND SUBGRADE IS TO BE TERMITE TREATED. 26.9. SIZES ARE NOMINAL AND CAN VERY +/- 2" IN SIZE IF EGRESS IS NOT EFFECTED. FTG FOOTING 17.7. SLAB FINISHES UNO: FT FOOT (OR FEET) 9. PRIOR TO ANY EXCAVATION WORK: -MAIN BUILDING: STEEL TROWEL FINISH 27. ELECTRICAL & LIGHTING NOTES 9.1. THE CONTRACTOR IS REQUIRED TO LOCATE ANY AND ALL UTILITIES IN OR UNDER CONSTRUCTION, AND MAKE -GARAGE: STEEL TROWEL, THRESHOLD: LIGHT BROOM 27.1. PLANS ARE SCHEMATIC. EXACT LAYOUTISIZING OF CIRCUITS, RECEPTACLES, FIXTURES, AND GALV GALVANIZED ARRANGEMENTS FOR THEIR LEGAL RE-ROUTING, AS ACCEPTABLE TO GOVERNING AGENCIES, AUTHORITIES, -DRIVEWAY, DRIVEWAYAPRON, PORCHES/PATIOS: LIGHT BROOM EQUIPMENT, SHALL BE DETERMINED BYAN ELECTRICAL CONTRACTOR. IF LAYOUT/SIZING IS PROVIDED GFI GROUND FAULT INDICATOR A LAFFECTED TILITY PANIESAND INFORM THEM OF UTILITIES AND OWNER. CONTACT LU COM HE IMPENDING 17.8. GARAGE, AND ALL EXTERIOR HARD SURFACES TO SLOPE AWAYFROM BLDG MIN 1/8"/FT. ELECTRICAL CONTRACTOR TO VERIFY. GSF GROSS SQUARE FEET CONSTRUCTION, AND OBTAIN THEIR ASSISTANCE IN LOCATING THEIR UTILITIES. 17.9. CONCRETE PADS FOR VIBRATING EQUIPMENT SUCH AS PUMPS OR MOTORS TO BE SEPARATED FROM 27.2. ALL 120V 15AAND 20A DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT TYPE. GWH GAS WATER HEATER HOUSE SLAB WITH A MINIMUM OF AN ASPHALT EXPANSION JOINT. 27.3. PROVIDE AFIC AS DETERMINED BY NEC 210.12 OR FBC R 3902. GWB GYPSUM WALL BOARD 10. DIMENSIONS: 17.10. RECESS SGD &GARAGE DOOR THRESHOLDS 3/4"-VERIFY EXACT DIMENSIONS WITH SUJ PLIER/MFR. 27.4. PROVIDE GFIC AS DETERMINED BY NEC 210.8 OR FBC R 3902. 10.1. DIMENSIONS ON ARCHITECTURAL DRAWINGS MAY BE "ROUGH" OR "FINISH." SEE PLANS FOR REQUIREMENTS. 17.11. COLUMN/WALLAND FOOTING CENTERLINES SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 27.5, ALL EXTERIOR OUTLETS TO BE GFIC WITH WEATHER TIGHT PROTECTIVE COVER. HS HOSE BIB ARCHITECTURAL DIMENSIONS SHALL TAKE PRECEDENCE OVER STRUCTURAL OR OTHER DIMENSIONS, IF NO OTHER 17.12. SLOPE GRADES AWAY FROM BUILDING ON ALL SIDES A MINIMUM OF 6" OVER 10', 4:1 SLOPE MAX. 27.6. SMOKE ALARMS SHALL BE HARD WIRED, INTERCONNECTED, W/ BATTERY BACKUP PER FBC R314. HC HOLLOW CORE CONFLICT RESULTS. DOCUMENT ANY SUCH DISCREPANCIES TO ARCHITECT IN WRITING. DO NOT RELY ON SCALED 27.7. CARBON MONOXIDE ALARM TO BE INTEGRAL WITH SMOKE ALARM AND COMPLY WITH FBC R315. HOG HOT DIPPED GALVANIZED DIMENSIONS. NOTES TAKE PRECEDENCE OVER GRAPHICS. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS FOR 18. STRUCTURAL STEEL: 27.8, PROVIDE POWER RECEPTACLE & LIGHT, WHEN ATTIC CONTAINS AHU OR HAS STORAGE AREA. HORIZ HORIZONTAL WORK TO EXISITING BUILDINGS. 18.1. ALL STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A-36AND THE "SPECIFICATION FOR THE HW HOT WATER DESIGN, FABRICATIONAND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" BY THE AMERICAN 28. PLUMBING: HWH HOT WATER HEATER 11. HEIGHT ELEVATIONS: H GHT INSTITUTE OF STEEL CONSTRUCTION, A PIP A - TYPE F = S CO STRUC ION. ALL STEEL E SHALL CONFORM TO ASTM A 53 E 35 1 28.. PLANS ARE SCHEMATIC. ACTUAL LOCATION MATERIAL, ,AND SIZE OF PIPES, DRAINS, AND VENTS SHALL 11.1. BUILDING HEIGHT ELEVATIONS TYPICALLY USE THE MAIN FLOOR SLAB AS ELEVATION U-0" (BUILDING ELEVATIONS MAY KSI). BE DETERMINED BYA LICENSED PLUMBER, IF LAYOUT/SIZING IS PROVIDED PLUMBING CONTRACTOR TO IN INCH I B NOTED A "BLDG EL. " OR "EL. " OR "AFF. "ANY ELEVATION NOT OTHERWISE DESIGNATED AS A SITE E NO S G ) 18 .2. ALL SHOP CONNECTIONS T E WELDED AND FIELD CONNECTIONS N T BE BOLTED N OTHERWISE O S O B EL C O S 0 OL ED UNLESS HER SE VERIFY. INT INTERIOR ELEVATION IS ON ANY PLANS OTHER THAN THE SITE PLAN IS ASSUMED TO BE A BUILDING ELEVATION SITE SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS. ALL WELDING IN ACCORDANCE WITH AWS D1.1 28.2. SEPTIC & DRAIN FIELD IS SCHEMATIC, EXACT LAYOUT/SIZING SHALL BE BYA LICENSED SEPTIC ELEVATIONS MAY BE BASED ON THE SURVEY, WHICH MAY USE MEAN SEA LEVEL, NAVD, OR OTHER HEIGHT AS A "STRUCTURAL WELDING CODE". USE E70XX ELECTRODES LINO, CONTRACTOR AND ADHERE TO 64E-6, F.A.C. JT JOINT REFERENCE DATUM. SITE ELEVATIONS MAY BE NOTED AS: "SEL OR "_ NAVD" OR "+X.X' ". CONSULTARCHITECT 18.& ALL STEEL TO RECEIVE ONE SHOP COATAND ONE FIELD TOUCHUP COAT OF APPROVED PAINT. 28.3. NO PLUMBING REQUIREMENTS SHALL INTERRUPT THE STRUCTURAL INTEGRITY OF THE BUILDING. _" FOR ANY QUESTIONABLE LOCATIONS PRIOR TO CONSTRUCTING. 18.4. ALL BOLTED CONNECTIONS SHALL CONSIST OF ASTM A325 HIGH STRENGTH BOLTSAND HARDENED MAX MAXIMUM WASHERS AS SHOWN ON THE STRUCTURAL DRAWINGS. ALL BOLTED CONNECTIONS SHALL CONFORM TO 29. ROOF PENETRATIONS: MEP MECH/ELECT/PLUMB 12. AMBIGUITY: THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" BY THE AMERICAN 29.1. VERIFY ALL REQUIRED ROOF PENETRATIONS FROM HVAC, PLUMBING, ELECTRICAL, AND OTHER MFR MANUFACTURER 12.1. IN THE EVENT OF ANY AMBIGUITY OR QUESTION WITH REGARD TO THE INTENT OF THE DOCUMENTS, THE ARCHITECT INSTITUTE OF STEEL CONSTRUCTION. DRAWINGS. PROVIDE ALL NECESSARY PENETRATIONS WITH REQUIRED ACCESSORIES TO PREVENT MIN MINIMUM SHALL INTERPRET THE CONSTRUCTION DOCUMENTS. 18.5. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A36 ORA307 (THREADED ROD). MOISTURE INTRUSION AND RETAIN STRUCTURAL STABILITY, IN ADDITION TO THOSE INDICATED ON THE MO MASONRY OPENING 12.2. IN CASE OF CONFLICTS BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS, CONSULT WITH ARCHITECT. IN 18.6. SUBMIT SHOP DRAWINGS FOR REVIEW OF CONFORMANCE TO DESIGN CONCEPT. ROOF PLAN. CONSULTARCHITECT IF ROOF PLAN CONFLICTS WITH ANY REQUIRED ROOF PENETRATIONS. MW MICROWAVE CASE OF CONFLICT BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS, CONSULT WITH ARCHITECT. 18.7. GROUT FOR COLUMN BASE PLATES SHALL BE NON -SHRINK GROUT 5000 PSI MINIMUM. 31. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: NIC NOT IN CONTRACT 13. FLORIDA PRODUCT APPROVALS / SUBMITTALS / SHOP DRAWINGS: 19. LIGHT GAGE METAL STUDS & MISC. METAL FRAMING: 31.1. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: NTS NOT TO SCALE 13.1. THE SUBMISSION OF REQUIRED NOTICES OF ACCEPTANCE INCA) I PRODUCT APPROVALS ARE THE RESPONSIBILITY 19.1. ALL LIGHT GAGE METAL INTERIOR STUDS SHALL BE G90 GALVANIZED 25 GA MINIMUM, USE 20 GA STUDS 31.2. FINISHES TO COMPLY WITH THE BELOW FIGURES AS PER FBC R302.9 - 302.10 NSF NET SQUARE FEET OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO MAKE THESE AVAILABLEATTIME OF INSPECTION. EVEN WHERE HEAVY LOADS ARE HUNG FROM SUCH AS TV'S OR WALL CABINETS. ALL WALL TRACKS SHALL BE 25 31.3. INSULATION FLAME SPREAD: <25, INSULATION SMOKE DEVELOPED: <450 IF THE ARCHITECT PROVIDES THESE THE CONTRACTOR MAY CHANGE TO A DIFFERENT PRODUCT THAT MEETS THE GA. 31.4. WALUCLG FLAME SPREAD: <200, WALUCLG SMOKE DEVELOPED: <450 L-1 LINTEL #1 SAME OR HIGHER BUILDING DESIGN PRESSURES, SOME JURISDICTIONS WILL REQUIRE A REVISION. IF THERE ISA LF LINEAL FOOT DISCREPANCY BETW THE FASTENING OF PRODUCTS, ACCORDING TO MFR INSTALLATIONAND ARCHITECT'S SPECS, 20. HVAC: 32. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA: VERIFY W/ ARCHITECT. 20.1. N H T PLANS ARE SCHEMATIC. MATI C EXACT LAYOUT/SIZING OF UNITS DUCTS RETURN D SUPPLY U AIR GRILLES AN 32.1. WEATHERING: NEGLIGIBLE TERMITE AREA: VERY HEAVY OA OVERALL 13.2. SHOP DRAWINGS/SUBMITTALS WILL BE REVIEWED FOR DESIGN C CONFORMITY AN L 0 D GENERA CONFORMANCE TO GRILLES ETC, SHALL BE DETERMINED BYA HVAC LICENSED CONTRACTOR. IF LAYOUT/SIZING IS PROVIDED OC ON CENTER CONSTRUCTION DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING HVAC CONTRACTOR TO VERIFY. 33. MISC: OAS OR APPROVED SIMILAR DIMENSIONS ATJOBSITE FOR TOLERANCE, CLEARANCE, QUANTITIES, FABRICATION PROCESSES/TECHNIQUES OF 20.2. PROVIDE MANUFACTURED CONCRETE PADAND BRACKETS RATED FOR SPECIFIED WIND LOAD FOR 33.1. ROOF SYSTEM & FLASHING AS PER MFR INSTRUCTIONS. CONSTRUCTION, COORDINATION OF HIS WORK WITH OTHER TRADES, AND FULL COMPLIANCE WITH CONSTRUCTION CONDENSING UNIT. FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE 38.2.,UARDRP <;,S PER FBGP81= PL PROPERTY LINE OR PLATE DOCUMENTS. MANUFACTURER'S SPECIFICATIONS. PLY PLYWOOD o.4. '00.+. E SYSTEMS ' BF nor ER FSG Ro22rte fuvr' o, o � c,v,o i' a"re, AS PER PT PRESSURE TREATED 14. GENERAL STRUCTURAL 21. WOOD FRAMING 33.5. MECHANICAL APPLIANCES TO BE PROTECTED IF INSTALLED ON FLOOR IN GARAGE AS PER M1307.3.1. PVC POLYVINYL CHLORIDE 14.1. ONCE SIGNED & SEALED BYARCHITECT OR ENGINEER. DESIGN PROFESSIONAL CERTIFIES THATTHE CONSTRUCTION 21.1. ALL STRUCTURAL (LOAD BEARING) LUMBER SHALL BE S.Y.P. OR DOUGLASS FIR, GRADE #2, KD 19% (Fb FOR USE 2" DIA x 36"H PIPE W/ COLLAR BASE, ATTACH COLLAR TO SLAB W/ (4) 1/4" x 2.25" TAPCON. DOCUMENTS MEET THE LOAD REQUIREMENTS STATED IN THE APPLICABLE FBC REFERENCED. LUMBER SIZES NOTED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONALFOREST 33.6. CAULK BOTTOM OF SOLE PLATE AT GARAGE COMMON FRAME WALL. R RADIUS 14.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION. PRODUCTS ASSOCIATION NATIONAL DESIGN STANDARD SUPPLEMENT TABLE 4B), AND SHALL CONFORM TO 33.7. IGNITION BARRIER NOT REQUIRED FOR SPRAY FOAM IN ATTIC UNO. R!A RETURN AIR PROVIDE APPROPRIATE SUPERVISION THROUGHOUT THE PROJECT. CONSTRUCTION SITE SAFETY, INCLUDING ALL THE NATIONAL GRADING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND 33.8. PROVIDE FIRE BLOCKING AS PER FBC R 302.11. RCB REINFORCED CONCRETE BEAM ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT IS THE THE SOUTHERN FOREST PRODUCTS ASSOCIATION. ALL NON -LOAD BEARING FRAMING LUMBER (INTERIOR 83.9. RCC REINFORCED CONCRETE COLUMN RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE THE WALLS) TO BE #2 S.P.F. OR BETTER. THAN ^ 0998F AS PER rBG R392 12 RD ROOF DRAIN NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. TEMPORARY BRACING 21.2. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE AND/OR MASONRY TO BE PRESSURE TREATED. ALL REF REFRIGERATOR AND SHORING SHALL BEDESIGNED TO RESIST ALL CONSTRUCTION LOADS INCLUDING THE WEIGHTS OF ALL WOOD EXPOSED TO THE WEATHER OR IN CONTACT WITH THE GROUND TO BE PRESSURE TREATED TO 0.80 34. FINISHES: REINF REINFORCING SUPPORTED MATERIALS PLUS A LIVE LOAD OF 50 PSF ON HORIZONTAL SURFACES. MAINTAIN TEMPORARY BRACING CCA. 34.1. GWB: MOISTURE RESISTANT GWB @ ALL WET AREAS, CEMENT BOARD INSIDE SHOWER COMPARTMENTS. REQ REQUIRED AND RETAIN IN PLACE UNTIL PERMANENT STRUCTURAL SYSTEMS ARE CAPABLE OF RESISTING ALL CONSTRUCTION 21.3. SPLICING FOR MULTI -PLY HEADERS/BEAMS/COLUMNS: USE 5/8" TYPE X GWB ON GARAGE CEILING IF CONDITIONED/HABITABLE AREA ABOVE. GARAGE RIW RIGHT-OF-WAY PHASE LOADS. -2x4-10d COMMON NAIL @ 6" OC EACH LAYER STAGGERED. SEPARATION WALL TO HAVEA MINIMUM OF ONE 112" LAYER OF GWB ON THE GARAGE SIDE OF WALLAS RTU ROOF TOP UNIT 14.3. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND START OF -2x6- 2 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. PER FBC R302.6. SEE DOOR GEN NOTE 26.6. CONSTRUCTION. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL CONSTRUCTION AND ITS CONTENTS. -2x8- 3 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. 34.2. EXTERIOR LATH AS PER FBC R703.7.VASTM C1063-11A. FOR EXTERIOR CEILINGS/SOFFITS USE MIN, 5/8" S. SIMPSON (MFR) 14.4. SPECIFIC PRODUCT DATAMUST BE PROVIDED TO ARCHITECT FOR APPROVAL OF HEAVY FINISHES SUCH AS TILE -200- 4 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER, STUCCO ON RIBBED LATH. ATTACH TO BOTTOM OF WOOD FRAMING W/ 11GA NAILS W/ 3/8" HEAD @ 6" OC SBS STYRENE BUTADIENE STYRENE ROOFS OR STONE ON RAISED FLOORS. -2xl2- 5 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. W/ 1-3/4" EMBED INTO WOOD. TYP TRANSITION FROM WOOD TO CONIC (I.E. @ GABLE END) TO HAVE SEL SITE ELEVATION -LOCATE SPLICES OVER BRG SUPPORTS. GLUE BETW LAYERS. USE 16D IF 1/2" PLYSPACER USED VINYL CONTROL JOINT IN STUCCO. SF SQUARE FOOT 15. CAST -IN -PLACE CONCRETE 21.7. END STUDS OF EXTERIOR FRAME WALL CH TO CONC OR DESIGNATED INTERIOR SHEAR WALLS TO 34.3 T EXTERIOR T&G WOOD CEILING. ATTACH tx4 OR tx6 BOARD W/ 2' 16GA FINISH NAIL EA RAFTER/JOIST/BC. SIM SIMILAR 15.1. ARCHITECT OR ENGINEER OF RECORD TO BE NOTIFIED IN WRITING PRIOR TO POUR, TO GIVE ARCHITECT THE WALL W/ .25" x 3.25" TAPCON @ 16" OC/8" ENDS, FOR INTERIOR BRG WALLS USE 1/4" x 2.75" TAPCON @ 32" TO CHANGE ORIENTATION USE 2x4 FLAT PURLINS ATTACHED TO EA RAFTER/JOIST/BC W/ (2)16D NAIL. SK SINK OPTION TO INSPECT THE REINFORCEMENT FOR OVERHEAD BEAMS AND SLABS OC/8" ENDS. SOG SLAB ON GRADE 15.2. CONCRETE PROPORTIONING, PLACING, FINISHING AND CURING SHALL BE AS PER THE LATEST EDITION OF THE PCA 21.8. ALL WOOD NAILING AS PER FBC R 602.3 UNO. SS STAINLESS STEEL MANUAL. LEAVE SUPPORT FOR ELEVATED CONCRETE IN PLACE UNTIL THE CONCRETE HAS REACHED ITS DESIGN STAG STAGGERED STRENGTH: 22. PLYWOOD SHEATHING: -OVERHEAD SLABS AND BEAMS TO BE 4000 PSI CONCRETE MIN UNO 22.1. ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING. INSTALL PLYWOOD WITH FACE GRAIN PERPENDICULAR TBD TO BE DETERMINED -COLUMN AND WALL CONCRETE TO BE 3000 PSI CONCRETE MIN UNO TO SUPPORTS, PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON THE PLANS. TC TOP CHORD -FOOTINGS AND SLAB -ON -GRADE TO BE 3000 PSI CONCRETE MIN LINO 22.2. UPPER PANELS TO BE ATTACHED TO THE TOP MEMBER OF THE UPPER DOUBLE TOP PLATE AND TO RIM THE TO MATCH EXISTING -A G R A T PILE T B 0 PSI CONCRETE IN O U E G S O E5 00 S CO C M UN JOIST AT BOTTOM OF WALL. PROVIDE BLOCKING PLYWOOD OC NG FOR ALL EDGE NAILING OVER LENGTH OF O TOB TOP OF BEAM 15.3. CONCRETE, WHEN PLACED, SHALL HAVE SLUMP OF 6 INCHES MAXIMUM AND 1 INCH MINIMUM EXCEPT FOR SLABS 22.3. FOR EXTERIOR AND INTERIOR SHEAR WALLS USE 1/2" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE TOB TOP OF COLUMN ON -GRADE WHICH SHALL HAVE A MAXIMUM SLUMP OF 5 INCHES AND A MINIMUM OF 3 INCH. NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF CORNERS. NAIL SPECS: ASTM F1667 RSRS-03 (21/x" x 0.131") TOS TOP OF SLAB 15.4. COMPLY WITH ALL REQUIREMENTS OF ACI 117-10. ACI 318-14, ACI.315 22.4. FOR ROOF USE 5/8" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE TP TOP PLATE 15.5. ALL REINFORCING SHALL CONFORM TO ASTM 615 FOR GRADE 60 STEEL; WELDED WIRE MESH TO ASTM A-185. WITHIN 4' OF EAVESIRIDGES/GABLES. TPO THERMO PLASTIC OLEFIN ARRANGEMENT AND BENDING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF 22.6. FOR SUBFLOOR USE 3/4" PLYWOOD AND 2.5" #8 SCREWS & GLUE OR 8d RINGSHANK GALV NAILS & GLUE. TYP TYPICAL THE ACI DETAILING MANUAL AND THE CONCRETE REINFORCING STEEL INSTITUTE. DON'T SPLICE IN MIDDLE 1/3 OF SPACE FASTENERS 6" FIELD, 6" EDGE. BEAM OR COLUMN SPAN, IF A SPLICE IN SPAN IS UNAVOIDABLE, FOLLOW DEVELOPMENT LENGTH/LAP DISTANCE IF 22.6. FOR ATTIC FLOOR USE 5/8" PLYWOOD AND 6d RINGSHANK GALV NAILS. SPACE NAILS 12" FIELD, 12" EDGE. UG UNDER GROUND NOT NOTED VERIFY W/ ARCHITECT ONLYALLOWED WHERE TRUSS ENGINEERING SPECIFIES. UNO UNLESS NOTED OTHERWISE 15.6. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC., PRIOR TO PLACING CONCRETE. VB VAPOR BARRIER 15.7. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. VERT VERTICAL START INITIAL CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM THE CONCRETE SURFACE AFTER VTR VENT THRU ROOF PLACING AND FINISHING. KEEP CONTINUOUSLY MOIST FOR NOT LESS THAN 7 DAYS IN ACCORDANCE WITH ACI 301 PROCEDURES. PERFORM CURING OF THE CONCRETE BY CURING AND SEALING COMPOUND, BY MOIST CURING, BY W! WITH MOISTURE RETAINING COVER CURING OR BY COMBINATION THEREOF. WA WASHER MACHINE 15.8. SEE THE DRAWINGS FOR CONCRETE COVER FOR REINFORCING STEEL, BUT IN NO CASE SHALL THE COVER BE LESS WP WATERPROOF THAN THAT REQUIRED BY ACI318: WD WOOD -CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH; 3" WWF WELDED WIRE FABRICIMESH -CONCRETE EXPOSED TO EARTH OR WEATHER: #5 BARS AND SMALLER, 1 1/2" INCHES; #6 BARS AND LARGER, 2" 15.9. CONCRETE SLAB ON GRADE CONTROL JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLAN OR TYPICAL # POUND OR NUMBER DETAILS. WHERE CONTROL JOINTS ARE NOT SHOWN ON PLANS, ALL CONCRETE SLABS ON GRADE SHALL BE BOUND BY KEYED, DOWELED OR SAW -CUT CONTROL JOINTS SUCH THATTHE ENCLOSED AREA DOES NOT EXCEED 260 SQUARE FEET. POST -TENSIONED CONCRETE SLABS ON GRADE SHALL NOT HAVE CONTROL JOINTS UNLESS SPECIFICALLY NOTED ON THE PLANS. EXPANSION JOINT FILLER SHALL BE NON -EXTRUDED PREMOLDED MATERIAL OF ASPHALT IMPREGNATED FIBERBOARD (ASTM D1751) 15.10. CONSTRUCTION JOINTS OR POUR JOINTS IN STRUCTURAL ELEMENTS (BEAMS, COLUMNS, ELEVATED SLABS, ETC.) NOT SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS REQUIRE PRIOR APPROVAL OF THE ARCHITECT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING PROPOSED JOINTS TO ENGINEER FOR APPROVAL. 15.11. ALL CONCRETE SHALL UTILIZE A MINIMUM OF 20% FLYASH CONTENT. 15.12. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. PLACE VERTICAL REINFORCING BARS AT CORNERS, JAMBS OF OPENINGS, BELOW BEAM BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. VERTICAL WALL REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. -TIES/STIRRUPS TO STARTATA DISTANCE FROM SUPPORT OF 1/2 TIE SPACING 15,13. NO HOLES, CHASES, OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT ARCHITECT'S APPROVAL. o r.+ 4)- 3 1,_ U E O 0 0 0 ' -, (. _ a)c n C 2.0 -a UQ : " O 'Cc (1)-L►,_ C:)C m <Y Lo E -� 3+ c,r- 7 V d y+� Y0 0 O V m (0 LL "' LL C) of C) U 8 0 W Y 6 w 0 w = 1- a: 0 1. W 0 0 Cl f 0 J 0 W w w V N Z /N W 0) U ItW W UJ 0 M ° V J 0 Z W LL w 0 UJ �/ LL z 0 a z LL �/ U) _J 2 s✓ w 1J W 0 W 0 ,I Z W CD Ei Z _j � V E w w 3: a W w U5Z = w 6 m W I-- 0 z 6 e z r w w 0 I 0 a z 0 w 0 a F- Z W 2 z> O () F < 0 general notes 8/27/21 SHEET GN-1 .: -*- AR97106 . =LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read and given special attention to all persons installing trusses. SPACING NOTE All trusses are to be set 2'-0" on center except as noted. MULTIPLE PLY TRUSSES MUST BE FASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING Jal TO DETERMINE IF MULTIPLE PLY. DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Sp n or less ' Spre er Bar 60 degrees or less Tag line a*— 112 span �)/ Tag line —ApP 213 �� of approx 1l2 of span, REFER TO BCSI REFER TO BCSI Truss must be set this way R crane is used. Truss must be set this way If crane is used. Truss is an example, your truss may not match. Truss is an example, your truss may not match. Insist crane operator sap truss this way. insist crane operator sets truss this way. All load bearing walls, headers, beams, & lintels must be in place at indicated height before trusses are installed. A -- AIR HANDLER NOTE Unless noted elsewhere on this layout, these trusses are not designed for air handlers in the roof or for any other A/C requirements. This may be in conflict with building code and A/C Design requirements. Consult with Building Department and A/C Contractor. z`Do not s nd on trusses until they are braced per BCSI & properly nailled to straps and hangers !! A ARI,RANG WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 41' - 46' IN LENGTH!! Assail— L WARNING 1 The size of these trusses makes it necessary that they a set by a profeesional builder familiar with and experienced in the problems and dangers of setting large span trusses. The builder and erector should consult with an engineer licensed in Florida specializing in wood roof trusses about the safe erection of these trusses. The engineer should be at the job site when trusses are erected to provide supervision and advice. REPRESENTS THE LEFT SIDE OF EACH TRUSS DRAWING SEAT PLATES BY CHAMBERS TRUSS REPRESENTS A HANGER HANGER SCHEDULE USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN CARRIED TRUSS CARRYING TRUSS HANGER ID FASTENER FOR CARRYING TRUSS GRB1 GR2 THD26 1/2 E12-10d 18-16d `Please refer to Standard Engineering package for general Instuction on instamng nangers 10d-0.148" x 3" 16:14.162" x 312" Hatch Legend WALL HEIGHT 9'-411 3-08-00 GR1 0 0 & R GR4 10-08-00 61-08-00 61-08-00 2-02-08 W a U) 0 0 0 943v 38-04-00 C�Zi UNSUPPORTED JACK CONNECTION DETAIL MT816 slurp (or equal) over Top Chord and! under Bottom Chord with tad x 1.5" nails7 .,Is in Canner Jack; 7 in Hip Camer Double straps for 5' Jacks JACK 5' Trwseos beginning "JU" and other ,insupported truss should be in- ailed this way. PLUMB CUT END 2 2X4 TOP CHORD WALL HEIGHT 9'-4" 4 r END DETAIL: TYPICAL FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED The undersigned acknowledges and agrees: 1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for determining successful fabrication of the trusses. 2. All dimensions in this layout have been verified by the undersigned. 3. Unless written notice Is provided by certified mail to Chambers Truss within ten (10) days of delivery the undersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss Shall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.' After 10 days of delivery remedy will be according to Florida statute 558. 4. The undersigned acknowledges receipt of "BCSI" summary sheet by TPI & WTCA 5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has the sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will �e responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has io redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is iesponsibe to Chambers Truss for loafing costs due to site conditions. 6. Price as shown in paragraph 7 below is subject to change if any charges are made in this layout. A $60 per hour I flee for revisions may be charged by Chambers Truss. I 7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price. invoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of delivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss reasonable atlomeys fee for collections in event of payment not timely made. 1-12 % per month service charge w it be added for all sums not paid within terms. B. Signature or inifials anywhere on this sheet constitutes agreement to all terms herein. 9. In consideraflon of Chambers Truss extending credit for this material the undersigned unconditionally guarantees payment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the Undersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the recipient. 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to'. herein, the parties agree that the sole venue for any such action will be Saint Lurie County, Florida. I 11. Design responsibilities are per luNational Standard And Recommended Guidelines On Responsibilifies For construction Using Metal Plate Connected Wood Trusses ANSI/TPINPfCA 4 - 2002m t2. Warranty is per Chambers Truss Warranty attached. I DATED SIGNED FOR TITLE A spreader bar may be required per "BCSI'' to prevent injury & damage. Multiple ply trusses must be fastened together per engineering before they are set, failure to do so can result in roof collapse„ Temporary and permanent bracing are required and can save life and property l and is the responsibility of the truss erector. Study the contents of the information packet included on delivery before setting trusses. Trusses must be set and braced per design to prevent injury & damage. Trusses must be set plumb and square i I Do not set bunks or stack of plywood, roofing material or any other concentrated loads on trusses, this can cause collapse. DO NOT INSTALL TRUSSES USING THIS USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC "TflMllcan er Tvenue Fort Pierce, Florida 34982-6423 800.551.5932 Fort Pierce 772-465.2012 Fax 772.465.8711 Vero Beach 772-569-2012 Stuart 772-286.3302 Web Site: CHAMBERSTRUSS.COM Email: MAIL@CHAMBERSTFIUSS.COM LOADINGIDESIGN CRITERIA REDUCIBLE PER CODE SUCH AS SBC 1e(M.6.1 DESIGN CRITERIA County ST. LUCIE j Building Department ST. LUCIE CO. Wind Design Criteria ASCE 7-16 - Wind Design Method MWFRS(Directional)/C-C hybrid Wind ASIDE 7-16 Roofing Material Shingle or Shake Loading in PSF Roof R.D.L. Floor Top Chord Live 20 0 Top Chord Dead 10 4.2 0 Bottom Chord Live '10-Non Conccurent 0 Bottom Chord Dead 10 3 0 Total Load 50 7.2 0 Duration Factor 1.25 0 Wind Speed 160mph Top Chord C.B. Sheathing by builder Bottom Chord C.B. Sheathing by builder i Highest Mean Height 15' Building Type Enclosed Building Category II: Non Restrictive Exposure Category C>Open Terrain with scattered obstructions Miles from Ocean 5 Conforms to Florida Building Code 2020 R.D.L=Restraining Dead Load C.6=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record Chambers Truss Inc. Drawing Name: 77419 SCALE: 1 /4" = 1 I 151 total trusses, 45 unique designs Designer: RAC Reviewed by: _ Date:04/13/21 Revised:0$/17/21 FOR LORI ANN WINN DESCRIPTION: WINN Page 1 of 1 CUSTOMER INITIALS EACH PAGE 77419