Re: Permit # SLC-2107-0549
Certification of Inspection Revision per SLCBD—After The Fact Garage
Widner Residence
4871 Jorgensen Road
Fort Pierce, FL
Dear St. Lucie County Building Official:
Please be advised that Benchmark Engineering has approved the following inspections at the
aforementioned location and herby certifies that the construction is in substantial compliance
with FBC2020 and plans produced by Benchmark Engineering. Inspection dates and field notes
are provided and attached hereto. Inspection services by Benchmark Engineering are limited to
specific inspection requirements as defined by SLCBD and construction plans produced by
Benchmark Engineering. Voluminous photos were obtained from the owner during construction
and also taken during the inspections. Photos shall be retained at Benchmark Engineering.
Clarified inspection 116 (denote quantity of rebar) & 141 (specify wall insulation) are bolded in
the inspection chart attached for easy reference.
Thank you for your diligence and please feel free to contact me at (772) 267-1399 with any
comments or concerns that you may have.
Sincerely,
Bowdoin G. Hutchinson Digitally signed by Bowdoin G. Hatchinson
Date: 2022.01.10 18:23:53 -05 00
Bowdoin G. Hutchinson P.E.
G. NUrc /i
`�� 00,,•''��o tiny i This item has been electronically signed
_ N and sealed by Bowdoin G. Hutchinson, P.E.
T : 087 = using a Digital Signature and Date. Printed
copies of this document are not considered
OF ,%�\ signed and sealed and the signature must
•A-
�i p " .�RIDA #44' be verified on any electronic copies.
//////0IV�111100
AI
Inspection Date of Method of Inspection, Notes Result
Inspection
104 Compaction Test N/A Request Exemption per Section 1803.2; Garage is Approved
built adjacent to existing home w/no fill added
121 Termite Spray 3/1/18 Owner to provide Certificate of Termite Approved
Treatment
116 Mono Pre-Pour 12/27/21 Review of owner's photos: (3)#5 rebar in footer Approved
per plan
140 Const. Rough Framing 12/28/21 Visual, cut sample view port thru drywall & review Approved
owners photos
141 Insulation 12/14/21 Visual, R-30 batt ceiling, R-19 batt walls Approved
Visual, drywall & reviewed owners photos,
148 Window/Door Attach 12/29/21 Approved
conformed w/NOAs
Visual, cut sample view port thru drywall & review
650 Frame-All 12/28/21 owners photos, conductors inspected @ rect. & Approved
switches
133 Window/Door Bucks 12/29/21 Visual, removed sample partial trim, back out ws Approved
& reviewed owner's photos
Visual, removed partial 5-V, 5/8" CDX w/clips
134 Roof Sheathing 12/14/21 modified bitumen underlayment, 10D coil @ 4" Approved
OC all, in truss cords w/Zircon MT 6 Metal
Detector
Visual, cut sample view port thru drywall & review
135 Wall Sheathing 12/28/21 owners photos, 12D @ 4" OC w/Zircon MT 6 Approved
Metal Detector
Visual & review owners photos, HTS 16s field,
145 Truss DRWG 12/14/21 LSTA gable @ 48" OC Approved
167 Roof Final 12/14/21 Visual, removed#9 self-sealing screws Approved
280 Electrical Final 12/28/21, Visual, removed sample recpt. & switch plates, Approved
1/3/22 trip test all GFI, Reinspected; Replaced (1) GFI
993 Final Site Survey N/A Previously provided to SLCBD (on file) Approved
999 Final Inspection 1/3/22 As noted Approved