BLOWER DOOR TEST FORM.
House Infiltration Test Certification
Prescriptive and Performance Method
Date: 3/28/2022 Permit #: 2106.0593
Contractor: RENAR HOMES.
Job Address: - 425 SEAFOAM/CIR
Construction: ( X ) New Construction -Complete ( )Existing -After Addition
House Infiltration Test Fkesults SM-Climate Zone 2 3/28/2022
CFM (50) = I 1 'rest Date: _--
Volume
ACH (50) = CFM (50) x 60 / Volume = Mes nlca! Ventilation required less than 3 ACH
Passing results must be & ACH (SO) or less (. Pass .( ) Fall
FBC, Energy
The buiiding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 2 air changes per
hour in Climate Zone 1, Z and 3 air changes per hour In Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553,993(5) or (7), Florida statutes or individuals licensed as set forth in 5ectiori 489.105 (3)(0, (9) or (i) ar an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c, (50 Pa) in accordance with Section 11402.4.12 of the Florida Building Code, Energy Conservatlon
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Compa ECO-INNOVATIVE LLC 10670 S US HWY 1, STE 300. PORT ST LUCE, FL 34952
Company Name; Address;
_ _
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accyrdapce with Se rR2,4-1.2-Cllmate Zone 2.
Signature: . Y"
Printed Name: KATHLEEN CONNOLLY
License/Certification #: 5.060036