Loading...
HomeMy WebLinkAboutCompaction Test ®Ardaman Soil Density - Nuclear Client: Project: �•&Associates, Inc. Gauge Orrie Fenn 113-22-64-5418 Permit#SLC 2201-0304 5811 SPRUCE DRIVE 5811 Spruce Drive Pon St Lucie Branch Report Date:03/23/2022 FORT PIERCE,FL 34982 5811 Spruce Drive Florft Ra9164a4on No.5950 Test Method:ASTM D6938 Fort Pierce,FL 34982 460 NW Concourse Place,Urth t Pon St Lucie,FL 34998 Phone:TT2.8T8-0072 Test Results Maximum In Place In Place -Optimum-— —Dry--, --ImPlace— -"Dry - Wit Probe - - Soil Moisture Density (pcf) Moisture Density Density Depth Percent Min Comp. Test# Of Test Date Proctor ID Method Classification % 0/6 pct) in Compaction % Remark 1 03118/22 22-051 A - 11 A 113.5 7.6 109.1 117.6 12 96 95 Pass Modified 2 03118/22 22-051 A - 11.0 113.5 8.3 108.1 117.1 12 95 95 Pass (Modified) - _ - 3 03/18/22 22-051 A - 11.0 113.5 10.1 107.4 118.3 12 95 95 Pass (Modified) 4 03118/22 22-051 A - 11.0 113.5 11.3 107.8 120.0 12 95. 95 Pass Modified Test Information Gauge Test# Test Location Elevation Reference Make I Model/SH I Calibrated Field Technician 1 Building-Slab on Grade:Shed Slab NE Area -1.0 Top of Subgrade Troxler/3430P/80551/ Tech,Port St Lucie 2 Building-Slab on Grade:Shed Slab NW Area -1.0 Top of Subgrade Troxler/3430P/80551/ Tech,Port St Lucie 3 Building-Slab on Grade:Shed Slab SW Area -1.0 Top of Subgrade Troxler 13430P 180551/ Tech,Port SL Lucie 4 l Building-Slab on Grade:Shed Slab SE Area -1.0 Top of Subgrade Troxler/3430P 1805511 Tech,Port St.Lucie Remarks Comments Pass:Density Pass Tests are"Direct Transmission"(Method A)unless probe depth is noted as "Badcscatter".Gauge calibration data on file with the testing agency. RECEIVED r F MAR 2 5 2OZ2 i St-Lucie County �� f Perm��ti�� n M 0%— Y X h_ AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE'SUSMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 1 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. 9 r 10 -'A rd a m a n W Conn u Associates,Inc. 460 NW Concourse Place,Unit 1 Port St.Lucie,FL 34986 & Associates Inc. Phone(772)878-0072 FAX(772)878-0097 Florida Certificate of Authorization No.00005950 MODIFIED PROCTOR (ASTM D-1557) Project Name: 5811 Spruce Drive Date Sampled: 3/18/2022 Project Location: 5811 Spruce Drive,Fort Pierce,FL Sampled By: ML File Number: 22-5418 Date Tested: 3/22/2022 Client Name: Orrie Fenn Tested By: FIT 1000.0 Z � cc 1— I -F- -i _� - - _I- I w 100.0 I __.,-- i i LBR VALUE(%) LL +4 MATERIAL(%) _T_ 4 MATERIAL(%) 10.o i i 1 -- — _ — _ -- J - -- J - 1.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 201 a MOISTURE CONTENT(%) 130 i Tl L v Il L, MAX. DRY\� �,--I- Ii Ii i A�(fil ! i I "fi'�-i- i� (i i ( Z fL _ „ v�)i Fi f �� DENSITY(pcf) Tl t 125 I �I11 ! r r 11�� ii l �jl k { t _ _ L jj� _ ,_ a H �_l —I t 113.5 -� �I ! � - ('1� ��I _i' .,� �I 1_ ,� - r FIT I 1 I ..CL 120 i ? j Y ,7 I j I( , I I I i f_�at l � i i IL �: l' ' (' 11 I } i k MOISTURE l Z ri 1� I - I �"I I"L L_.f r 4 - \C {" I �-- 11.0 f; i1 — �t7 lf1 1 v* II II. w r i �11` I i r1 - rr II ,tl T , {li rr t-v Ij4 rrr , PERCENT 115 I I i. ' --L-- L j 1 1 j r I-i -1.. \I , I o F _ ) f rf r �rj �i� LI�}I } I FINES(/°). I l I { 'r`I �/A -�. {"' , .mod Z ,-1 }� T 1-1rI r�i- :11- 110 1 + , t i 11 i Curves of 100%Saturation ry r��L for Specific Gravity Equal to: G _.l Ia r �w �J- .f. 7 .. Li 1-- T If I )I+ _C i 2.60 105 i -11 6 11 �� I �i r I ,fit--` 1'' - .�� �-�. rf I i�, 1y-7-' I t f 11 I t i 2.65 - �"� ['r 1 1 ,� i l l I 1 -� -y- I) I f I r I T T I �I 1 100 � t I — { -}I-,-t i{ 1 Lr rt� rr 2.70 ————— 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 MOISTURE CONTENT SAMPLE NUMBER: 22-051 140. 53265 6� SAMPLE DESCRIPTION: Dark Brown Slightly Clayey Fine Sand with Organics SAMPLE LOCATION: In-Place : PROPOSED USE: Shed Pad(Sub grade) / /► I P Our letters and reports are fo'r the exclusive use of the client to whom they are addressed and shall not be � ON \ reproduced except in full without the approval of the testing laboratory.The use of our name must receive our / M \ written approval.Our letters and reports apply only to the sample tested and.or inspected,and are not - indicative of the quantities of apparently indentical or similar products. 6 2; son Pj Manni 1g,P Florida License No.53265