HomeMy WebLinkAboutAPPROVED, Notice of Acceptance'I
MIAMI•DiADE
DEPARTI•IEN I OF REGI
BOARD AND CODE .WW
NOTICE OF A!L�b
APR 1.2 2022
. Lucie County
Permitting
LATORY AND ECONOMIC RESOURCES (RER)
INISTRATION DIVISION
7EPTANCE (NOA)
_�o`��pStl"
il"I FOR
I
UNTf
P
NIIA1I1-DADS COUNTY PC/
PRODUCT CONTROL SECTION �j /
�1L
11805 SW 26 Street, Room 208
Miami, FL 33175
T (786) 315-2596 F (786) 315-2599 .
CGI Windows and Doors, Inc.
3780 W 104'h Street
Hialeah, FL 33018'
SCOPE:
This NOA is being issued under the applicable roles and regulations governing the use of constructiorf
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where. allowed by the Authority
Having Jurisdiction (�Ahi [ i).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product.Control
I;
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product for material tested for quality assurance purposes. If this product .or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to °revoke this acceptance, if it is determined by Miami -Dade County Product Control.
Section that this product or material fails to meet the requirements of the applicable building code.
This product is appro,.ed as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity. Hurricane Zone.
DESCRIPTION: Series "Sentinel" Unclipped Mullion - L.M.I.
li
APPROVAL DOCUMENT: Drawing No. MD-SENMUL, titled "Series Sentinel. Unclipped Mullions",
sheets 1 through 7 oi;7, dated 06/03/2020, prepared by manufacturer, signed and sealed by Anthony Lynn
Miller, P.E., beating & Miami -Dade County Product Control Revision stamp with -the Notice of Acceptance
number and expiration date by the Miami —Dade County Product Control Section.
I�
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Fachl unit shall bear a permanent label with the manufacturer's name or logo, city, state,.
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product:
TERMINATION of this NOA will -occur after the expiration date or if there has been a revision or change -
in the materials, use and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
.followed, by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A (copy of this entire NOA shall be provided to the user by the manufacturer or its'
distributors and shat'llbe available for.inspection at the job site at the request of the Building Official.
This NOA revises acrid renews NOA# 18-0117.01 and consists of this page I and evidence pages E-1 and "
E-2, as well as approval document mentioned above.
The submitted documentation was reviewed by Sifang Zhao, P.E.
.; NOA No. 20-0610.11
09/10/2020 Expiration Date: September 22, 2025
Approval Date: September 10, 2020
Page 1
FILE Copy
y
�wt. yz Op
cu ?OZ�
Aoncfe,o9 n�
DL'PgRTJ'11FNT OF
I) Al 11) ; REGUI,AI'0111r AND ECONOMIC RESOURCES (RER)
(O�l AI)1411NISTRATION DIVISION
NET -CE OF ACCEPTANC'
E NOA)
Wllldotivs and Doors, Inc.
3780 W 104',Street
Hialeah, FL 3301.8
SCOPE:
RE'VIEWED', FOR
CODE COMPLIANCE
ST. LUCIE COUN,Ty BOCC
MIAMI-DADS COI.1 TY Gs
PRODUCT CONTROL SECT'ON /
11805 SW 26 Street, Room 208 LZ 2
Miami, FL, 33l175
T (786) 315-2590 F (786) 315-2599
This NOA is being issued under the applicable rules and regulations governing the use of construct
materials. The documentation submitted has been .reviewed and accepted', by Miami=Dade County REI
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authoi
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miaiiii-Dade County Product Cont
Section (In Miami Dade County) and/or the AHJ (in areas other than Mianii Dade County) reserve the ri;
to have this product or material tested for quality assurance purposes. if,this product or material fails
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ n
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. R
reserves the right to revoke this acceptance, if it is determined by Miarnil-Dade County Product Cont
Section that this product or material fails to meet the requirements of the app,i�icable building code.
This product is approved as described herein, and has been designed to coinply with the Florida Build
I
Code, including the High Velocity Hurricane Zone. ;!
r�
DESCRIPTION: Series "Sentinel" Unclipped Mullion -L.M.I.
APPROVAL DOCUMENT: Drawing No. MD-SENMUL, titled "Series Sentinel Unclipped Mullions",
sheets 1 through 7 of 7, dated 06/03/2020, prepared by manufacturer, signed and sealed by Anthony Lynn
Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp,lwith the Notice of Acceptance
number and expiration date by the Miami —Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
• RENEWAL of this NOA shall be considered after a renewal application has! been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there;',has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse ofithis NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Faililre
to comply with any section of this NOA .shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -,Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request (if 'ihe,Building Official.
This NOA revises and renews NOA# 18-0117.01 and consists of this page 1 and evidence pages E-1 and
E-2, as well as approval document mentioned above. j
The submitted documentation was reviewed by Sifang Zhao, P.E.
i{ I
S.
t I
.; i NOA No. 20-0610.11
MIa�ItivaoEcouren Expiration!Date: September 22, 2025
e 09/10/2020 Approval Date: September 10, 2020
�1 Page I
i
ANCE:
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS, 'I
1. Manufacturer's die drawings and sections. (Submitted under NOA No.10-0510.14)
2. DrawiIrig No M10-01, titled "Series Sentinel Unclipped Alum. Mullions", sheets l
through 7 of 7, dated 04/02/10, with revision D dated 11/08/17, prepared by AI-Farooq .
Corpo�e` tion, signed and sealed by Javad Ahmad, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
along ,with marked -up drawings and installation diagram of an aluminum tube mullion,
prepared by Hurricane test Laboratory, LLC, Test Report No. HTL-0080-0303-11,
dated �03/24/1 1, signed and sealed by Vinu J. Abraham, P.E.
(Subrrritted under NOA No.11-0330.22)
2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94 .
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of an alumij'uun tube mullion,
prepared by Hurricane test Laboratory, LLC, Test Report No. HTL-0080-0301-10,
dated.03/30/10, signed and sealed by Vinu J. Abraham, P.E.
(Sub I fitted under NOA No. 10- 0510.14)
I:'
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 611
Editio in (2017), dated 10/15/14 and updated on' 09/25/17, prepared by Al-Farooq
Corporation, signed and sealed by Javad Ahmad, P.E.
D. QUALITY ASSURANCE
1. Miarr%i-Dade Department of Regulatory and Economic Resources (RER).
E. MATERIA CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 511 Edition (201.4), and of no
financial interest, dated October 4, 2014, issued by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E.
2. Laboratory compliance letter for Test Report No. HTL-0080-0303-11, issued by
Hurricane Test Laboratory, LLC, dated March 24, 2014, signed and sealed by Vinu J.
Abraham. P.E. (Submitted under NOA No. 11-033 0.22)
Sifang Zhao, P.E.
Product Control Examiner
NOA No. 20-0610.11
Expiration Date: September 22, 2025
Approval Date: September 10, 2020
E-1
3
Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEME �TS (CONTINUED)
3. Laboratory compliance letter for Test Report No. HTL-0080-0301-10, issued by
Hurricane Test Laboratory, LLC, dated March 30, 2040, signed and sealed by Vinu J.
Abraham, P.E. (Submitted under NOA No. 10-0510.14)
4. Proposal No. 09-1942 issued by BCCO, dated November 05, 2009, signed by Manuel
Perez, P.E. (Submitted under NOA No.10-0510.14)
I
G. OTHERS' i
1. Notice, of Acceptance No. 14-1103.09, issued to CGI Windows & Doors for their
Seriesi. '`Sentinel" Unclipped, Extruded Aluminum Tube Mullion - L.M.I. approved on
03/05' 15 and expiring on 09/22/20.
2. NEW EVIDENCE SUBMITTED
A. DRAWINGSi
1. Drawing No. MD-SENMUL, titled "Series Sentinel Unclipped Mullions", sheets 1
through 7 of 7, dated 06/03/2020, prepared by manufacturer, signed and sealed by
Anthony Lynn Miller, P.E.
B. TESTS
1. None !'
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC-6th
Edition (2017) and FBC-7` (2020) dated 05/27/2020, prepared by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL' CERTIFICATIONS
1. Nonel;
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 61h Edition (2017) and with FBC
7th Edition (2020), and of no financial interest, dated June 03, 2020, signed and sealed by
Anthony Lynn Miller, P.E.
2. Statement letter of successor engineer per 61 G15-27.001 Florida Administrative Code.
G. OTHERS I'
1. Notice of Acceptance No. 18-0117.01, issued to CGI Windows & Doors for their'
Seri es;"Sentinel" Unclipped, Extruded Aluminum Tube Mullion - L.M.I. approved on
03/61 / l 8 and expiring on 09/22/20. "
Sifang Zhao, P.E.
Product Control Examiner
NOA No. 20-0610.11
Expiration Date: September 22, 2025
Approval Date: September 10; 2020
E-2
SERIES SENTINEL UNCLIPPED ALUMINUM MULLIONS
WINDOW FRAME MEMBER INCLUDED IN PROPERTIES
THESE MULLIONS TO BE USED WITH
SERIES 130 SENTINEL FIXED WINDOW
SERIES 110 SENTINEL SINGLE HUNG WINDOW
SERIES 120 SENTINEL HORIZ SLIDING WINDOW
•
+{ 1.000
�{ 1.000
1.000 r
4.000
2.500
3.000
.125 TYP. F-
.125 TYP. h-
.125 IYP. I�
1 X 2-1/2 STD. TUBE
1 X 3 STD. TUBE
6063-T6
1 X 4 STD, TUBE
6063-T6
6063-T6
FOR WINDOWS IMPACT AND LOAD RATINGS SEE
CORRESPONDING NOA'S.
LOWER DESIGN PRESSURE FROM WINDOW APPROVALS
OR MULLION CHARTS WILL APPLY TO ENTIRE SYSTEM.
NOTES'
THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE
REQUIREMENTS OF THE 2017 (GTH EDITION)/2020 (7TH EDITION) FLORIDA
BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ).
ALL GLAZING PRODUCTS USED WITH THESE MULLIONS MUST MEET THE
APPLICABLE CODE REQUIREMENTS I.E.: WIND LOAD, WATER INFILTRATION,
FORCED ENTRY RESISTANCE. SAFEGUARDS ETC.
1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE
DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT
LOADS TO THE BUILDING STRUCTURE
ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON
DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED
EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR
STUCCO.
A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD
ONLY.
ALL SHIMS TO BE HIGH IMPACT. NON-METALLIC AND NON -COMPRESSIBLE.
MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT
COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE
REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED
STANDARDS.
THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE
INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS
PRODUCT, ADEQUACY OF STRUCTURE RECEIANG THIS PRODUCT AND
SEAUNG MOUND OPENING FOR WATER INFILTRATION RESISTANCE ETC.
CONDITIONS NOT SHOWN IN THIS DRAWING ME TO BE ANALYZED
SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL -
THESE MULLIONS ARE RATED FOR LARGE & SMALL MISSILE IMPACT
INSTRUCTIONS:
USE CHARTS AS FOLLOWS.
STEP 1 DETERMINE DESIGN LOAD REQUIRED PER ASCE 7
FOR PARTICULAR OPENING.
STEP 2 USE CONNECTION OF WINDOWS TO MULUON AS PER
PRODUCT APPROVAL
USING CHARTS ON SHEETS 3 THRU 5 SELECT MULLION TYPE
STEP 3 AND ANCHOR QUANTITIES WITH DESIGN RATING MORE THAN
THE DESIGN LOAD SPECIFIED IN STEP 1 ABOVE
STEP 4 CAPACITY OF SELECTED CGI-S WINDOWS AND MULLION
MUST EQUAL OR EXCEED REQUIRED LOADS.
PRODUCT REVISED
as aompl ing with the Florida
Building Code
Non -No. 20.0610.11
Expiration Date 09/2212025
Be __ I -- -
A) UPDATED TO FBC 2020.
AK - 06 m()
W
N
=a
J
> H
0
O
Zz
J > n O
LLU
V-v F-
O
<
(n
O
mZJLL
❑
N
Fg
UMWG
C
W 8 2 Z W
W
.OGN
0¢. I- w'- a:
~O
Z
Dma
Kowa
z
O
Z
O
LL
O
z
~
w
H o IIq
a
laaas
(A
z
.y ail ri Oco
J
z
G N
z
Q C�
n
to
J
0 0
o
z
Z
mz..
OMJ
LU
t7ngm22
V 2
-....�sa0
apll
saue5
`�11�1lilll/!/
NY LYN1V
`•,� No.58705
Q '• STA OF
COI NAL
A LYNN MILLER, P.E.
P.E# 58705
1 OR 2 ANCHORS FLANGE, FLANGE ADAPTOR AND FLUSH FRAM
AT EACH SIDE OF HAT 'A' F (AT WINDOW FRAME) SEE CHART 'B' FOR CAPACITY SEE CHART 'A' FOR CAPACITY CAN REUSED AT ALL MULLION COMBINATIONS.
TYPICAL SEE CHART 'A' FOR CAPACITY
11 L—J EXTERIOR
FIND TO FMD
SEE CHART 'A' FOR CAPACITY
z
a
in
z
0
WI
J_ wz J
IIOR
S.H. TO S.H.
SEE CHART 'A' FOR CAPACITY_, ,
a
W
z
3
N
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 20-0610.11
Expiration Date 09/22/2025
_ _Miami-Dade.Produ_c_t_C0n_tral_ _ —
W1 1 1. W2
A) N0 CHANGES THIS SHEET.
I SEE SHEEP 7 FOR FRAME DETAILS 0 AK-OBlD8/20
FRAMES MAY BE
ri FLANGE OR EQUAL LEG TYPE �
:RIOR L—J EXTERIOR
H.R. TO H.R. WIDTH (W) = wi + w2
SEE 2
I_
CHART 'AFAR CAPACITY
N
z
3
Ir
wT
w2 I
CD
tS
.
S
W N naa
J Ili ,D
W
O N O ainQ Y Z
H O UJ
W �G
= � B
� IIMDIQ
KU W U. W 'ON
a~W� � Z QMQ
w.o > � O
a�z� � n
LL
O
y c a la°us
QNno02w0. v F Z Z
j W aloa5
LL
O � O W z
asap eijl 1119'si
NYI LYNN
air°•••;
Ei� •F??�<<
NQ. 58705
G�
S/ONALL��•\•
A LYNN MILLER, RE
P.Ek 58706
S
W N naa
J Ili ,D
W
O N O ainQ Y Z
H O UJ
W �G
= � B
� IIMDIQ
KU W U. W 'ON
a~W� � Z QMQ
w.o > � O
a�z� � n
LL
O
y c a la°us
QNno02w0. v F Z Z
j W aloa5
LL
O � O W z
asap eijl 1119'si
NYI LYNN
air°•••;
Ei� •F??�<<
NQ. 58705
G�
S/ONALL��•\•
A LYNN MILLER, RE
P.Ek 58706
CHART'A' DESIGN LOAD CAPACITY - PSF
MULLION WITH ANY COMBINATION OF SERIES SENTINEL
FIXED, HORIZONTAL SLIDING OR SINGLE HUNG WINDOWS
CHART'A'DFSICTI LOAD CAPACITY- PSF
MULLION WITH ANY COMBINATION OF SERIESSENTINEL
FIXED, HORIZONTAL SLIDING OR SINGLE HUNG WINDOWS
WINDOW DIMS.
I ANCHOR AT
EACH SIDE OF MULLION
2 ANCHORS AT
EACH SIDE OF MULLION
WINDOW DIMS.
I ANCHOR AT
EACH SIDE OF MULLION
2 ANCHORS AT
EACH SIDE OF MULLION
WIDTH (W)
MULL SPAN
MULLTUBE
IX2-12
MULLTUBE
IX3
MULLTUBE
IX4
MULLTUBE
IX2-12
MULLTUBE
IX3
MULLTUBE
1 X 4
WIDTH (W)
MULL SPAN
MULLTUBE
1X2-12
MULLTUBE
IX3
MULLTUBE
1X4
MULLTUBE
IX2-12
MULLTUBE
IX3
MULLTUBE
IX4
19-1/8"
26-12"
37"
49"
53-18"
50-58"
90.0
90.0
90.0
90.0
90.0
90.0
24"
30"
36"
42"
48"
54"
60"
48"
-
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
82.9
82.9
-82.9
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
76.9
76.9
76.9
90.0
90.0
90.0
$6.9
86.9
86.9
90.0
90.0
90.0
76.9
76.9
76.9
90.0
90.0
90.0
85.5
85.5
85.5
90.0
90.0
90.0
-19-18"-"
-26.1/2-
- 37"-
49"
53-18"
-----
_ ,
---90.0-----
90.0---
-90.0
90.0
90.0
90.0
85.5 -
85.5
_85.5_
90.0 __.
90.0
90.0
-74.7-
-74.7-
-74.7-
-90.0-
_90 U
90.0
85.5
85.5
85.5
90.0
90.0
90.0
- -63"-
-59:8--
---59.8-
-59:8-=
-83:3-
-=90.0-
-90.0-
_ - 24'=-
30"
36"
42"
48"
54"
60"
- -- -
60"
-85.5=
--85.5-
-85.5�
=-90.0----
90.0
-.---90.0- _
90.0
_90:0-
90.0
52.2
52.2
1 52.2
70.7
90.0
90.0
73.0
73.0
73.0
50.9
50.9
50.9
68.5
90.0
90.0
65.1
65.1
65.1
90.0
90.0
90.0
19-18"
26-12"
37"
49"
76"
77.5
77.5
77.5
81.5
90.0
90.0
60.1
60.1
60.1
90.0
90.0
90.0
59.2
59.2
59.2
60.2
80.3
90.0
57.0
57.0
57.0
84.9
90.0
90.0
45.3
46.3
46.3
45.3
60.4
90.0 -
55.3
55.3
55.3
81.7
90.0
90.0
37.0
39.0
39.0
37.0
49.3
77.3
54.7
54.7
54.7
80.6
90.0
90.0
53-18"
35.2
37.5
37.5
35.2
47.0
73.4
24"
30"
36"
42"
49"
54"
60"
72"
68.4
68.4
68.4
77.8
90.0
90.0
19-18"
26-12"
37"
49"
53-118"
85"
57.9
68.3
68.3.
57.9
77.3
90.0
57.6
57.6
5,7.6
63.9
85.3
90.0
42.6
51.8
51.8
42.6
56.8
90.0
50.7
50.7
50_3
55.0
73.4
90.0
31.7
40.0
40.0
31.7
42.3
74.3
46.0
46.0
46.0
49.0
65.4
90.0
25.5
33.2
33.2
25.5
34.0
59.3
42.8
42.8
42.8
45.0
60.0
95.5
24.1
31.7
31.7
24.1
32.2
1 55.9
40.5
40.5
40.5
42.2
56.2
81.1
19-1/8"
26-12"
37"
49"
90"
48.7
64.0
64.0
48.7
65.0
90.0
39.1
39.1
39.1
40.3
53.8
78.2
35.7
47.7
48.4
35.7
47.7
83.7
24"
30"
36"
42"
48"
1 54"
84"
48.4
57.0
57.0
48.4
64.6
90.0
26.5
35.3
37.2
26.5
35.3
62.1
39.5
47.6
47.6
39.5
52.7
90.0
21.1
28.2
30.7
21.1
28.2
-49.5
33.7
41.5
41.5
33.7
44.9
78.4
19-18"
26-12"
37"
96"
40.0
53.4
59.6
40.0
53.4
90.0
29.7
37.2
37.2
29.7
39.6
68.8
29.3
39.1
44.9
29.3
311
68.7
26.9
34.2
34.2
26.9
35.8
61.9
21.6
28.9
34.3
21.6
28.9
50.7'
24.8
32.0
32.0
24.8
33.1
56.9
NOTE:
MULLIONS RATED IN THESE CHARTS WITH ANY COMBINATION
OF FIXED, SINGLE HUNG OR HORIZ. SLIDING WINDOWS
MAY BE ORIENTED VERTICALLY OR HORIZONTALLY.
(INTERPOLATION BETWEEN WIDTHS ALLOWED)
MULLION SPAN
1 OR 2 ANCHORS AT EACH SIDE OF MULLS
ALL OTHER ANCHORS TO BE AS PER
WINDOW NOA DETAILS
�. W7 W2
24"
30"
36"
42"
48"
96"
32.2
43.0
48.9
32.2
' 43.0
75.5
26.1
34.9
40.5
26.1
34.9
61.2
22.2
29.6
35.1
22.2
29.6
51.9
25.9
31.3
25.9
45.5
23.2
28.5
23.2
40.8
MULLION SPAN
1 OR 2 ANCHORS AT EACH SIDE OF MULLS
ALL OTHER ANCHORS TO BE AS PER
WINDOW NOA DETAILS
W1 W2
O
C
WIDTH (W) = W1 + W2
FLANGE OR FLUSH FRAMES
PRODUCT REVISED
as complying with the Florida
Building Code
NDA-No. 20-0610.11
Expiration Date 09/22/2025
-_ _ - =Miami-Dado:Froduc;-Control_ _. _
A) NO CHANGES THIS SHEET.
.o AK-06103120
rc
WIDTH (W) = w1 + W2
2 NOTE:
FIN FRAMES REFER TO PAGE 2 FOR OTHER COMBINATIONS.
WCD
ro
N
00
nay
J W N
Z K
O
O
J
g
J N O
a1o0
1d
(9
Z
>•��o a4
Q
❑
❑ Z Ld
mw
u0
�UUd W
'aN
om0
V
o
Z
O
n �
�
LL
O
rn z
CV)
Gt Yi
a
leans
'ra o7t 0{�
Yn o Z W
o� �
(n
U
Z
❑
F
Z
ca �
N
G
LL'
Q
J
aioas
C
E3 �LL
L=i
z
0�r'+
❑
h
r2
Z
0 � .
OJ
LLJ
CO
O eh M
�so0
a/71
rauaS
ANY LYNNM� /,�
No.58705
VAF
S • G,
TONAL +�r1.�.
A. LYNN MILLER, P.E.
P.E# 58705
CHART'B' DESIGN LOAD CAPACITY-PSF
CHART'B' DESIGN LOAD CAPACITY- PSF
MULLION WITH COMBINATION OF SERIES
SENTINEL
MULLION WITH COMBINATION OF SERIES SENTINEL
SINGLE
HUNG WINDOWS
OR FIXED
TRANSOM
SINGLE
HUNG WINDOWS
OR FIXED T
RANSOM
WINDOW DIMS.
I ANCHOR AT
EACH SIDE OF MULLION
2 ANCHORS AT
EACH SIDE OF MULLION
WINDOW DIMS.
1 ANCHOR AT
EACH SIDE OF MULLION
2 ANCHORS AT
EACH SIDE OF MULLION
WIDTH (W)
MULL SPAN
MULL TUBE
1X2-1/2
MULL TUBE
1X3
MULL TUBE
IX4
MULL TUBE
1X2-12
MULL TUBE
IX3
MULL TUBE
1 X 4
WIDTH (W)
MULL SPAN
MULL TUBE
1X2-1/2
MULL TUBE
IX3
MULL TUBE
IX4
MULL TUBE
IX2-12
MULL TUBE
IX3
MULL TUBE
IX4
PRODUCT REVISED
as complyIng with the Florida
Building Code
NOA-No. 20-0610.11
19-1l8"
26-I2"
37"
50-5/8"
90.0
90.0
90.0
90.0
90.0
90.0
24"
30"
36"
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
82.9
82.9
82.9
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
90.0
49"
42"
48"
Expiration Date 09/2212025
76.9
76.9
76.9
90.0
90.0
90.0
86.9
86.9
86.9 1
90.0
90.0 •
90.0
53-1/8"
48"
-54" -
-
-
_
-MiamiDado-Product;Control_ _
I
76.9
76.9
76.9
90.0
90.0
90.0
85.5
85.5--
85.5
- 90.0
- 90.0
90.0
19-1/8--
-
- - -
--
___ 90:0-
-
_-90.0�
_-90:0=
90:0
900_
-90.0-
-85:5-
85:5.
-85:5.-
-90.0-
-90.0-
-9 0.0
74.7
74.7
74.7
90.0
90.0
90.0
85.5
85.5
85.5
90.0
90-.0
--90.0----
---
26-12"
60"
- -
37"
49"
53-1/8"'
63"
59.8
59.8
59.8
90.0
90.0
90.0
24"
30"
36"
85.5
85.5
85.5
90.0
90.0
90.0
A) NO CHANGES THIS SHEET.
AK-06103120
52.2
52.2
52.2
90.0
90.0
90.0
73.0
73.0
73.0
90.0
90.0
90.0
50.9
50.9
50.9
89.4
90.0
90.0
65.1
65.1
65.1
90.0
90.0
90.0
42"
60"
19-1/8"
77.5
77.5
77.5
90.0
90.0
90.0
60.1
60.1
60.1
90.0
90.0
90.0
26-12"
48"
59.2
592
59.2
78.5
90.0
90.0
57.0
57.0
57.0
90.0
90.0
90.0
37"
76"
54"
46.3
463
46.3
59.0
74.2
90.0
55.3
55.3
55.3
90.0
90.0
90.0
49"
60"
Q
39.0
39.0
39.0
48.2
60.6
78.1
54.7
54.7
54.7
90.0
90.0
1 90.0
53-1/8"
K
w
2 > N
z o '°
> ti O
F
j s'�'
a z u_ . N
� w U m w
w c w z
a ^o
a z
0
N
O
m
o
slop
U
F-
¢
U
Q
•asap
Y
0
uxo o
ney
37.5
37.5
37.5
46.0
57.7
75.0
24"
30"
36"
42"
48"
54"
60"
72"
68.4
68.4
68.4
90.0
90.0
90.0
19-1/8"
26-12"
37"
49"
53-1/8"
85"
683
683
683
75.6
90.0
90.0
57.6
57.6
57.6
83.4
90.0
90.0
J
D
z
LU
U)
51.8
51.8
51.8
55.6
69.8
90.0
50.7
50.7
50.7
71.8
90.0
90.0
40.0
40.0
40.0
41.4
52.0
80.1
46.0
46.0
46.0
64.0
80.4
90.0
33.2
33.2
33.2
33.2
41.7
66.5
42.8
42.8
42.8
58.6
73.7
85.5
31.4
31.7
31.7
31.4
39.5
63.5
40.5
40.5
40.5
55.0
69.1
81.1
19-1/8"
26-12"
37"
49"
90"
63.5
64.0
64.0
63.5
79.8
90.0
39.1
39.1
39.1
52.6
66.1
78.2
46.6
48.4
48.4
46.6
58.6
90.0
24"
30"
36"
42"
48"
54"
8411
1
57.0
57.0
57.0
63.2
79.4
90.0
zz
J
j
�
w
OL
U
j
-1
z
z
U
ell!1
ON
DAM
. 34.5
372
37.2
34.5
43.4
70.1
47.6
47.6
47.6
51.5
64.7
90.0
27.5
30.7
30.7
27.5
34.6
55.9
41.5
41.5
41.5
43.9
55.2
82.9
r
ILL
O
v
laays
19-1/8"
26-12"
37"
96"
52.2
59.6
59.6
52.2
65.6
90.0
37.2
37.2
37.2
38.7
48.7
74.4
38.2
44.9
44.9 1
38.2
48.1
77.6
34.2
34.2
34.2
35.0
44.0
68A
o z
"m 0 e 3
vi on o
2 y o Z
30 w
G C
E 3 �' N f J H
S a-
O 8 3
UMS�
`-
28.2
34.3
34.3
28.2
35.4
57.3
32.0
32.0
32.0
32.4
40.7
64.0
NOTE:
MULLIONS RATED IN
MAY BE ORIENTED
(INTERPOLATION BETWEEN
MULLION SPAN_,
�__
THESE CHARTS
VERTICALLY OR
WIDTHS
WITH SINGLE
HORIZONTALLY
ALLOWED)
Wl
HUNG FRAMES
AS SHOWN
'
1
ALL
WINDOW
W2
BELOW.
OR 2 ANCHORS AT
OTHER ANCHORS
NOA DETAILS
EACH SIDE
TO BE AS
OF MULLS
PER
24"
30"
36"
42"
48"
96"
42.0
34.1
28.9
25.3
22.7
48.9
40.5
35.1
31.3
26.5
48.9
40.5
35.1
31.3
28.5
42.0
34.1
28.9
25.3
22.7
52.8
42.8
36.3
31.8
28.5
85.3
69.2
58.7
5 L4
46.1
rn
~
z
"logs
J
Z
W
�
seises
vc-
Q':' ••.�
o,
: No. 58705
E� 4j
�0.'. STATE
G
0NAL I��•\•
WIDTH W -
W1 + W2
2
A. LYNN MILLER, P.E.
P.Ep 58705
CHART'C' DESIGN LOAD CAPACITY - PSF CHART 'C' DESIGN LOAD CAPACITY - PSF
HORIZONTAL M ULLION WITH COMBINATION OF SERIES SENTINEL HORIZONTAL MULLION WITH COMBINATION OF SERIES SENTINEL
FIXED OVER HORIZ. SLIDING WINDOW FIXED OVER HORIZ. SLIDING WINDOW
WINDOWDIINS. 1 ANCHORAT 2 ANCHORSAT WINDOWDIMS. I ANCHOR AT. 2 ANCHORSAT
EACH SIDE OF MULLION EACH SIDE OF MULLION EACH SIDE OF MULLION EACH SIDE OF MULLION
WINDOW WINDOW TRANSOM MULLTUBE MULL TUBES MULLTUBE MULLTUBE WINDOW WINDOW TRANSOM MULLTUBE MULLTUBES MULLTUBE MULLTUBE
WIDTH HEIGHT HEIGHT I X 2-12 I X 4 1 X 3 I X 4 WIDTH HEIGHT HEIGHT 1 X 2-12 I R 4 1 X 3 I X 4 PRODUCT REVISED
12" 90.0 90.0 90.0 90.0 12" 90.0 90.0 90.0 90.0 as complying with the Florida
18" 90.0 90.0 90.0 90.0 18" 90.0 90.0 90.0 90.0 BullCode
NOA-N o. 20-0610.11
24" 90.0 90.0 -90.D 90.0 24" 90.0 90.0 90.0 90.0 Expiration Date 09/22/2025
- - - -52=18" - -- - --30"- 90.0 -90.0 90.0 90.0 36" ' 30" 90.0 90.0 90.0 90.0 /^
-36" -90.4- _90.0- _90.0_ _90_0 36" 90.0 90.0 90.0 90.0 - 13y- - - - --- - - --
- - - - - _Miami -Da duet Control
42"-_-90:0 --90.0 90:0 90:0-- - - -- - -- - 42"- -90.0 90.0-- - -90.0- ==90 0-
25" 48" 90.0 90.0 90.0 90.0 48" 90.0 90.0 90.0 90.0
12" 90.0 90.0 90.0 90.0 12" 90.0 90.0 90.0 90.0 .. A) NO CHANGES THIS SHEET.
18" 90..0 90.0 90.0 90.0 18" 82.4 82.4 90.0 90.0 o AK - 06/03/20
24" 82.9 82.9 90.0 90.0 24" 76.4 76.4 90.0 90.0
c
73° 30" 74.3 74.3 90.0 90.0 52-1B" 62" 30" 1 72.2 1 72.2 90.0 90.0
1 42" 1 63.6 1 63.6 . 1 85.0 1 90.0 1
52-IB"
37-38"
73"
36"
24"
52-I8" 49-58" 30"
86.3
86.3
90.0
84.8
84.8
90.0
90.0
%0
90.0
78.3
78.3
90.0
69.7
69.7
90.0
63.5
63.5
88.0
58.9
58.9
80.0
55.5
55.5
73.3
90.0
75.7
.3
90.0 '
73"
42" 17.4 67.4 90.0 90.0
48" 66.4 66.4 90.0 90X0
12" 64.2 1 64.2 85.5 1 90.0
18" 1 57.7 1 57.7 1 77.9 1 90.0
24" 60.1 60.1 sz.7 9a.0 FrW OVER A.R.
73" 30" 55.5 55.5 75.6 90.6
36" 1 52.0 1 52.0 1 69.6 1 90.0
44.3 57.5 75.7
42.7 54.0 71.5
1 OR 2 ANCHORS
AT EACH SIDE OF MULLION (AT WINDOW FRAME)
TYPICAL
SEE CHART FOR CAPACRY
2
s
O
N
2
0
_ WINDOW WIDTH
o
Q
as
cc
Wco
J {t1 a
N
N
O
J
z it o
o
g
>9 O
a+oa
Y
C
Z
0
}off
z 0 � N
�g
Mv0
w=w
'
�UUo W
'oN
a 1'- w W
Z
91A0
'X
O
LL
W
O
Lo
oz
H Q ! 3
W
Oa
laa4S
H OIJ
s 3g 3tpm
F
J
Z
Z
p, C Z N
Q
J
aia�s
e3 <$�
f)
z
o'=a.
Q
Z
poWn
®
O
W
Z
o
J
(j)
0
qll
sauo5
U i'I1j/'/
oNY IvAt
...
No.58705 •�
G
,
,
A LYNN MILLER, P.E.
P.E# 58705
TYPICAL ANCHORS
1 OR 2
#8 SMS
1-1/4" MIN. WOOD EMBED
1BY AT EACH SIDE OF MULL(AT
W000 BUCKn SEE SHEET 3 & 4
WINDOW FRAME) METAL 2BY WOOD BUCK 1 OR 2
STRUCTURE OR AT EACH SIDE OF MULL
d ; •' . ' .a • I FOR CAPACITY X
v.'•
WOOD STRUCTURE SEE FOR CAPACITY
N � it a . { • e
d.
REVIthe SED
• t• •G I
6
�PRODU 9 with
I
Building Code
N0A No. 20-0610.11
Expiration Date 09/22/2025
= x x
By-
- -Miami-Dade Produet_Control_. -
-
A) ADDED ULTRACON+
o ANCHORS.
TYPICAL ANCHORS TYPICAL ANCHORS TYPICAL ANCHORS
1 OR 10R2 1 OR2
AT EACH SIDE OF MULL AT EACH SIDE OF MULL AT EACH SIDE OF MULL
SEE SHEET 3 & 4 SEE SHEET 3 & 4 SEE SHEET 3 & 4
> AK-08103/20
FOR CAPACITY FOR CAPACITY FOR CAPACITY
TYPICAL ANCHORS: SEE ELEV. FOR SPACING
1/4" DIA. TAPCON BY 'ITW' (Fu=125 KSI, Fy=100 KSI)
1 /4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI)
WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WOW. INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
w
N
as
j
MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS)
AND TRANSFER THEM TO THE BUILDING STRUCTURE. n'P• EDGE DISTANCE INTO WOOD STRUCTURE = 1" MIN.
Z rX
5
z
THRU 1 BY BUCKS INTO CONC. OR CMU OR
Z o
DIRECTLY INTO CONC. OR CMU
>- N O
m
Y
W
1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS)
c ~
as N
FLANGE, FLANGE ADAPTOR AND 1-1/4" MIN. EMBED INTO CMU (JAMBS)
mil .
e
0 Zo
FLUSH FRAMES CAN BE USED TYP. EDGE DISTANCE INTO CONCRETE AND CMU = 2-1/2" MIN.
Wxui , T
-.0
Z
J�MO
AT ALL ANCHORAGE CONDITIONS. 1 /4" DIA. ULTRACON+ BY 'DEWALT' (Fu=164 KSI. Fy=148 KSI)
¢ Lu Z v Lu
INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
1-3/8" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS)
o >
CL Z
U
Z
O
-I
W
2 3/I 1" MIN. EDGE DISTANCE
LLO
e ?
THRU 1 BY BUCKS INTO CONC. OR DIRECTLY INTO CONC.
w
m
1" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS)
\ 1-3/4" MIN. EDGE DISTANCE
w o p m
6 o
I¢
p
EL
2
1ee4S
2 3/� a MIN THRU 1 BY BUCKS INTO HOLLOW CMU OR DIRECTLY INTO HOLLOW CMU
,,,
°C 3 1 9m.
Q
Z
co
Z
I I 1-1/4" MIN. EMBED INTO CMU (JAMBS)
❑yo
F
aloes
1-1/2" MIN. EDGE DISTANCE
#14 SMS OR SELF DRILLING SCREWS. (GRADE 2 CRS)
\ INTO MIAMI-DADE COUNTY APPROVED MULLIONS (MIN. THK.=1/8")
C a ax g
E 3 $ F`
Ow
o3, n
g
Q
Tp
LU
W
2
Z
OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS)
5 g o
?
y
(3) THREADS MIN. PENETRATION BEYOND SUBSTRATE
v =
•osa0
ap i
sai{a5
ALUMINUM - 1/8" THK. MIN. (6063-T5 MIN.)
N WHEN USED THE MIN. WOOD STEEL : 1/8" THK. MIN. (Fy = 36 KSI MIN.)
v BUCK DEPTH SHALL BE 2%". (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED)
THE USE OF DEEPER OR
�.`��N(L`(NN'^''i�
Q ••••
•. !�
TYPICAL EDGE DISTANCE
BEVELED WOODBUCKS IS
.•'�1c8Nsp'
a' P
d,I a° .,
INTO WOOD STRUCTURE = 1" MIN.
PERMITTED.INTO METAL STRUCTURE = 3/4" MIN.
� Q':
_ No.58705 ••;
A.-•d
- " -0' ' • `
• a +� 'e, '
#8 SMS (GRADE 2 CRS)
INTO WOOD STRUCTURES FOR FIN FRAMES ONLY
! b G O
7;� '•
a , <•
' G '\
FDCED WINDOW ANCHOR INSTALLATION DETAILS SHOWN.
�Oc g AT of <4�
. < a a TYPICAL ANCHORS
1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS)
FCORiOP,.' \?�
G
EACH
ALSO APPLICABLE TO SINGLE HUNG AND
1AT MIN. EDGE DISTANCE
`
AT SIDE OF MULL
SEE SHEET 3 & 4
HORIZONTAL SLIDING WINDOW FRAMES IN FLANGE, WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN.
�//11I I II111
.'n
FOR CAPACITY
EQUAL LEG OR FIN FRAME CONFIGURATIONS. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN.
A LYNN MILLER, P.E.
C-90 HOLLOW/FILLED NORMAL WEIGHT BLOCK AT JAMBS I'm = 2000 PSI MIN.
P.E.#58705
.SGG
1.301
7.563
2.sps
2737
O65
TlP.
065
O85
Tom•
065
TW.
2.505
1.335
2.440
TMP•
1.745
3.675
1.429
3.175
2.505
2.613
.811
PRODUCT REVISED
�17
•71
065
1.015
TYP.
Building Code
1.
NOA No. 20-0610.11
.99-- _ , _
1.015
I,pppIF
Expiration 09I2212025
,745
2.846
-0110
.991
^D�ate
By ---
Miami- ontrol
SERIES 110 SENTINEL
SERIES 120 SENTINEL
SERIES 130 SENTINEL
H.R. WDW. FLANGE FRAME HEAD
H.R. WDW. FLANGE FRAME JAMB
S.H.
WDW. FLANGE FRAME JAM13
S.H. WDW. FLANGE
FRAME HEAD
FIX. WDW. FLANGE FRAME
S.H. WDW.
FLANGE FRAME SILL
H.R. WDW.
FLANGE FRAME JAMB
o
A) NO CHANGES THIS SHEET.
AK-06103120
CGI-118
CGI-136
CGI-135
CGI-137
CGI-139
�j .812
1.301
1.583
2.737
.s
�
065 -TYp
065
7YP'
2.505
065
TYP.
065
T'P.
' Q
^aa
2.440
2.613
w
N
-.1
2.505
3.175
2-505
J Wpt N
rn
1.335
1.015
1.245
.811
1.429
LAg>
z o #
>• n O
0
a1°0
Y
7
Z
W
.745 TYP.
Q�e d
O
Q
.995
.745
2.346
500
.991
z LL $ F
-.,a
❑
1.495
1.015
2.505
2737
W U L d U
Lu
o
H.R.
WDW. FLUSH FRAME HEAD
H.R. WDW. FLUSH
FRAME JAMB
SERIES
S.H. WDW.
110 SENTINEL
FLUSH FRAME
SILL
H.R.
SERIES 120 SENTINEL
WDW. FLUSH FRAME JAMB
¢ F z v W
Z
ama
SERIES 130 SENTINEL
FIX. WDW. FLUSH FRAME
w j
o
a z °:
O
J
S.H. WDW. FLUSH FRAME JAMB
S.H. WDW. FLUSH FRAME HEAD
CGI-101
CGI-116
j
1`
LL
0
CGI-119
CGI-102
CGI-100
1.015
1.015N
Z
G O
❑
W
n
y G ee 3 Is
•m
a
1ea45
1.140
1140
.
ea m
-i
V)
Z
F1
1.450
.180a5.
o -
z
?
4.430
O65
TYP.
3.930
3.765
O85
TYP'
.050
.550
1.
80
X
W3.685
Z
2.885
2.885
A g
U m 2 ..
W
°sap
apl
saua5
/!
-2.440-12.440-ai
1.395
Q�;'•• •.F� '�
SERIES
H.R. WDW.
120 SENTINEL
FLUSH FRAME
SILL
_FLANGE ADAPTOR
_� No. 58705
- A
SERIES
H.R. WDW.
120 SENTINEL
FLANGE FRAME SILL
CGI-109
FIN ADAPTOR
' '
CGI-173
CGI-110
yI 41-
•,. 6 / i2 D
CGI-138
0 •. STATE OF •' (V�;
/ONAL E�;• �•
•
A. LYNN MILLER, P.E.
P.F-# 58705
i
M IAM!•DADE
I
DEPARTMENT OF RE
130ARD AND CODE Al
NOTICE OF A,
CGI Windows and 1
3780 W 104" Street
Hialeah, FL 33018
SCOPE:.
This NOA is being
materials. The docui
Product Control Sect
Having Jurisdiction
This NOA shall not I
Section (In Miami D
to have this product
perform in the accer
immediately revoke,
reserves the right to
Section that this proc
This product is appr
Code; including the I
DESCRIPTION: S�
APPROVAL DOC
sheets 1 through 7 of
Miller, P.E., bearing
numberand expiratic
MISSILE IMPACT.
LABELING: Each
model/series, and fo
noted herein.
RENEWAL of this iNOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product:
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, useJ and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically tenninate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
1IT: The NOA number preceded by the words Miami -Dade County; Florida, and
iration date may be displayed in advertising literature. If any portion of the NOA is'
Al be done in its entirety. f
icopy of this entire NOA shall be provided to the user by the manufacturer or it
Is
1 be available for_inspection at the job site at the request of the Building Official. - I
nd renews NOA# 18-0117.01 and consists of this page 1 and evidence pages E-1 and
ival document mentioned above.
nentation was reviewed by Sifang Zhao, P.E.
APR 112022.
St. Lucie County
Permitting
I.ATORY AND ECONOMIC RESOURCES (RER)
INISTRATION DIVISION
-EPTANCE (NOA)
FOR j
CODE
MIAMI-DADE COUNTY'' ' C/
PRODUCT CONTROL SECTION /
2
11805 SW 26 Street. Room 208
Nliami, FL 33175
T (786) 315-2590 F (786) 315-2599 .
wn•w.miamidade.ovkconomv
followed by the e
displayed, then it
INSPECTION::,
distributors and sh
This NOA revises
E-2, as well as apl
The submitted doc
B
d•
Inc.
^I
issued under the applicable rules and regulations governing .the use of construction i
nentation submitted has been reviewed and accepted by Miami -Dade County RER -
ion to be used in Miami Dade County and other areas where allowed by the Authority
f I I I)
'e valid after the expiration date stated below. The Miami -Dade County Product.Control
ade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
!or material tested for quality assurance purposes. If this product .or -material fails to
ted manner, the manufacturer will incur the expense of such testing and the AHJ may i
modify, or suspend the use of such product or material within their jurisdiction. RER
revoke this acceptance, if it is determined by Miami -Dade County Product Control
det or material fails to meet the requirements of the applicable building code.
31ved as described herein, and has been designed to comply with the Florida Building
Iigh Velocity Hurricane Zone.
.,ries "Sentinel" Unclipped Mullion - L.M.I.
JMENT: Drawing No. MD-SENNIUL, titled "Series Sentinel. Unclipped Mullions". �
7, dated 06/03/2020, prepared by manufacturer, signed and seated by Anthony Lynn
the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance
n date by the Miami —Dade County Product Control Section.
F RATING: Large and Small Missile Impact Resistant
unit shall bear a permanent label with the manufacturer's name Or logo, city, state,
lowing statement: "Miami -Dade County Product Control Approved", unless otherwise
.;'. , NOA No. 20-0610.11
09/10/2020 Expiration Date: September 22, 2025
Approval Date: September 10, 2020
Page 1
�72_13S G j��o
FILE COPY APR 2
oz
cour�r%
DEPARTMENT OF REGULATORY AND ECONOiIIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
REVIEWED FOR
ODE COMPLIANCE
Si LUCIE COUNTY BOCC
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION 11�
805 SW 26 Street Room 208
Miami, FL 33175
T (786) 3;15-2590 F (786) 315-2599
I I Ww.miamidade.eov/economy
CGI Windows and Doors, Inc.
3780 W 104" Street �
Hialeah, FL 3301.8
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by ibliami=Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Countv Product Control.
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this "Ito LICt or material fails to
perform in the accepted manner, the manufacturer will incur the expense of su 'li testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material witIIin their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicabIl,e building code.
This product is approved as described herein, and has been designed to comply, with the Florida Building
Code, including the High Velocity Hurricane Zone. I;
DESCRIPTION: Series `Sentinel" Unclipped Mullion - L.M.I. j
APPROVAL DOCUMENT: Drawing No. MD-SENMUL, titled "Series Sentinel Unclipped Mullions",
sheets 1 through 7 of 7, dated 06/03/2020, prepared by manufacturer, signed and I Baled by Anthony Lynn
Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance
number and expiration date by the Miami —Dade County Product Control Section! s
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant I'
�
LABELING: Each unit shall bear a permanent label with the manufacturer'Is name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has b'eien fled and there has been
no change in the applicable building code negatively affecting the performance Of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically Iterminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
1
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. It"lany portion of the NOA is
displayed, then it shall be done in its entirety. �''I
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA# 18-0117.01 and consists of this page 1 arid' evidence pages E-1 and
E-2, as well as approval document mentioned above. 1'
The submitted documentation was reviewed by Sifang Zhao, P.E, ill
e I'IMIAMMADECOU �''' '• NOA No. 20-0610.]]
09/10/2020 Expirat►onlDate: September 22, 2025
Approval Date: September 10, 2020
j Page 1
i
I