Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL PANEL WALLSFlorida Building Code Online } Product Approval e USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory FL9190-R9 Revision 2020 Approved REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC f �c -4 �/' 0 � �Z- FILE COPY 2 7-01 -0733 LP Building Solutions 414 Union Street - Bank of America Plaza Suite 2000 Nashville,!TN 37219 (352)425-7457 cw.macomber@lpcorp.com CW Macomber cw.macomber@lpcorp.com CW Macomber 5712 SW 40th Place Ocalo, FL 34474 (352)425-7457 cw. macorrlber@Ipcorp. com CW Macomber 5712 SW 40th Place Ocala, FL134474 (352)425-7457 cw.macomber@lpcorp.com Panel Walls Siding Compliance Method Evaluatioh Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received i Florida Engineer or Architect Name who developed the Do Kim, 1,.E. Evaluation Report Florida License PE-49497 Quality Assurance Entity APA - The Engineered Wood Association Quality Assurance Contract Expiration Date 12/31/2030 Validated By James L.'Buckner, P.E. @ CBUCK Engineering ., Validation Checklist - Hardcopy Received Certificate of Independence FL9190 R9 COI certificate of independence. pdf i Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By I Sections from the Code 1405 1604.3.1 https://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDquJPW%2b4UtPI LM%2fVA7w4rtSE%2bkuUji%2bUgYQ%3d LP Sm' artSideo , TRIM & SIDING At the time of manufacture, siding meets or exceeds the performance standards set forth in ICC-ES AC321 and has achieved code recognition under ESR-1301, CCMC 11826-L, APA recognition under PR-N124, and HUD recognition under HUD-MR-1318c. For copies of Product Approvals go online at https://Ipcorp.com/res6.urces/product-literature/ or call LP Customer Support at 800-648-6893. • Minimum 6 inch (152 mm) clearance must be maintained between siding and finish grade (ground cover). • Siding applied adjacent to porches, patios, walks, etc. must have a clearance of at least 1 inch (25 mm) above any surface. • Minimum 1 inch (2S mm) clearance at intersection with roof line. • Apply siding in a manner that prevents moisture intrusion and water buildup. • All wood substrate that is exposed to the weather must be sealed in a manner that prevents moisture intrusion and water build up. - Seal ALL exposed cuts of siding and trim. Field spray applied coatings on cuts are not recommended. - Sealing can be accomplished by applying a coating or sealant according to the manufacturer's requirements. - Butt joints that are covered with joint molding, sealant orfactory prefinished end, are considered sealed from the weather. • See Alternate Fastening Options for fastening lap siding to SIP, ICF and Steel Frame assemblies. • DO NOT USE STAPLES. • SIDING MUST NOT BE INDIRECT CONTACT WITH MASONRY, CONCRETE, BRICK, STONE, STUCCO OR MORTAR. • Store off the ground well supported, on a flat surface, under a roof or separate waterproof covering, • Keep siding clean and dry. Inspect priorto application. STUD SPACII.NG. • 38 Series Strand Substrate lap may be installed on studs spaced a maximum of 16 inches (406 mm) o.c. • See Alternate Fastening Options for fastening 38 Series Strand Substrate 6 inch (152 mm) and 8 inch (203 mm) lap on studs spaced a maximum of 24 inches (610 mm) o.c. 76 Series Strand Substrate lap may be installed on studs spaced a maximum of 24 inches (610 mm) o.c. 38 AND 76 SERIES STRAND SUBSTRATE SMOOTH FINISH OR CEDAR TEXTURE PRIMED LAP SIDING For installations over masonry or concrete walls, the wall shall be furred out and open at the top and bottom of the wall to allow for convective ventilation between framing spaced 16 inches (406 mm) o.c. The framing shall be of adequate thickness to accept 1-1/2 inches (38 mm) of nail penetration. A properly installed breathable water-resistant barrier is required between the siding and masonry or concrete walls. • Moisture control and moisture vapor control are critical elements of proper housing design. Check your local building codes for application procedures for handling moisture and water vapor in your area. • When using wet blown cellulose insulation, the insulation must not be in direct contact with the siding and it must be I llowed to dry a minimum of 24 hours or longer if specified by the insulation manufacturer. • As with all wood products, do not apply engineered wood siding to a structure having excessive moisture conditions such as drying concrete, plaster or wet blown cellulose insulation. If such conditions exist, the building should be well ventilated to allow it to dry prior to the application of the siding. • Siding must not be applied to green or crooked structural framing members. Do not apply siding over rain -soaked or buckled sheathing materials. • Gutters are recommended for control of roof water run off. • A properly installed water-resistant barrier is required behind siding. Consult your local building code for details. • The LP SmartSide limited warranty does not expressly or implicitly cover water penetration. LP does not assume it for any water penetration. i • Seal all gaps with a high -quality, non -hardening, paintable sealant meeting ASTM C920, minimum Class 25. • Follow the sealant manufacturer's instructions for application. i • All) openings must be properly sealed or flashed in a manner that prevents moisture intrusion or buildup. Several examples that accomplish this are shown on the following pages. I WINDOWS,LAS���• 'bPENINGS i • All openings must be properly sealed or flashed in a manner that prevents moisture intrusion or buildup. Several examples that accomplish this are shown on the following pages. KICI(-OUT FLASHING • Install kick -out flashing to direct the water into the gutter • Install step flashing with minimum 4 inch upper leg • Properly integrate flashing with the secondary water -resistive barrier. Use housewrap, flashing tape, Z-flashing, or other items as needed to maintain the counterf lashing principle. • DO NOT extend the siding or trim into the kick -out flashing or gutter • Maintain a clearance between the end of the gutter and the adjoining wall to allow for proper maintenance of the siding • Prime and paint ALL exposed cut edges Min.1" clearance between trim and roofing Clean rain gutter Do not run trim or siding inside the Icicle out flashing Trim should be thick enough so the siding does not extend beyond the face of the trim. • Trim and fascia must be applied in a manner that will not allow moisture intrusion or water buildup. • LP° SmartSide° siding is not designed and/or manufactured to be used as trim or fascia. LP SmartSide trim and fascia are available in a variety of dimensions. i • Prime and paint all exposed surfaces including all drip edges or where water will hang. Application instructions (cant.) • Apply finish coat as soon as possible or within 180 days of application. • High -quality acrylic latex paint, specially formulated for use on wood and engineered wood substrates, is highly recommended. Semi -gloss or satin finish oil or alkyd paints are acceptable. For flat alkyd paint, please check with the coating manufacturer for their recommendations for use on composite wood siding. • Follow the coating manufacturer's application and maintenance instructions. i DO NOT USE • Stain. • Vinyl -based paint (like vinyl acetate, or PVA). HANDLE PREFINISHEO LP SMARTSIDE PRODUCTS WITH EXTREME CARE DURING STORAGE AND APPLICATION. TOUCH UP ANY DAMAGE TO THE FINISH THAT MAY OCCUR DURING APPLICATION PER PREFINISHERS SPECIFICATIONS. • In blaced wall assemblies, use minimum (0.113 inch shank diameter) hot -dipped galvanized nails for38 and 76 Series panels and minimum (0.131 inch shank diameter) for 190 Series panels. Do not use electroplated fasteners. Refer to your local building code to verify the minimum allowable fastener size. • Penetrate structural framing or wood structural panels and structural framing a minimum of 1-1/2 inches. • For 38 Series panels, double nailing procedure meets wall bracing requirements and S/16 inch shear wall design values. 1"from edge Alignment bead Figure 1 Double row of nails • For 76 and 190 Series panels, single nailing meets wall brac- ing requirements. To meet the equivalent 3/8 inch shear wall design values, double nailing procedures must be used. It may be necessary to angle drive the second nail in order to penetrate the framing. Seal nails driven below the surface. 3/8" from edge Alignment bead 1/8" gap Na'il penetration min.1-1/2" Figure 2 i i Single row of nails Application instructions tconta) • Shear values for panels applied directly to studs shall be no greater than noted in Table 1:of the ICC-ES Report ESR-1301 or Table 1 of APA PR-N124. • Not warranted for application on ICF assemblies. • 38 and 76 Series panels must be installed on 16 inch o.c. framing only. When installing on 24 inch o,c. framing,190 Series panels are required. • Backside of panel must not come in contact with masonry or concrete foundation. • Do not force siding into place. Maintain the illustrated 1/8 inch gap behind the joint to allow for expansion while the panel equilibrates with the local environment. • DO NOT INSTALL OVER ALIGNMENT BEAD. Install panels in light contact to the edge of alignment bead. (see Figure 1 and Figure 2) • Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prefinished surface. • Where siding butts window trim, door casings and masonry, etc. leave a 3/16 inch gap and seal. Insulated Sheathings LP SmartSide Sidings may be installed over low -compression rigid foam or exterior gypsum. The following precautions must be followed: a) Adequate bracing of the wall in accordance with the International Codes or other ruling building code is required. b) For rigid foam sheathing up to 1 inch (2S mm) thick, siding may be nailed directly to the foam sheathing unless a drainage plane is required by the local building code. Nail length must be increased to ensure a minimum 1-1/2 inch (38 mm) fastener penetration into the structural framing. c) For rigid foam sheathing greaterthan 1 inch (2S mm), a minmum 1-1/2 inch (38 mm) thick by 3-1/2 inch (89 mm) wide vertical strapping or furring strip must be installed over the sheathing to provide a solid, level nailing base for the siding. The strapping must be securely fastened to structural framing spaced no greater than 16 inches o,c. (406 mm) with a minimum nail penetration of 1-1/2 inches (38 mm) and a maximum nail spacing no greater than the width of the siding. Louisiana-Pacific Corporation will assume no responsibility for any damage or condition arising from the use of rigid foam or exterior gypsum. 0-,:• � - �:� 12 max. A an; ' A. 4 field nailing 6"max. perimeter 6" max. t - nailing perimeter g. F nailing -' 6" min. ground Do not let panel clearance contact masonry (see Figure 7A and 713) Figure 3 CONDITION Snug , i Flush Visibl' fiber Countersunk i/is"-1/8"_ Countersunk more than 1'/s" 4" min. vertical flashing 1" min. clearance from roofing CORRECTION Apply sealant Apply sealant and —® re -nail Figure 4 Trim Prime and pal bottom drip edges LP SMARTSIDE PANEL SIDING'JOINT DETAILS HORIZONTAL WALL JOINTS BUTT B FLASH Siding 3/8" min. R. Blocking gap �. I Sloped flashing with 4" vertical leg Figure 5A LAP Siding Blocking 1 min. overlap ^Lap panel over bottom panel Figure 513 LAPPED HORIZONTAL WALL JOINT Siding Framing (band joist, truss chord, etc.) i" 1" min. / Wall Framing overlap Figure 5C APPLICATION INSTRUCTIONS (CONTo) sheathing to provide a solid level nailing base for the siding.11N-CCLEARANCE i The strapping must be securely fastened to structural framing spaced no greater than 16 inches (406 mm) o.c. with a mini- Figure , mum nail penetration of 1-1/2 inches (38 mm) and a maximum �*•• r �.,x nail spacing no greater than the width of the siding. t�,y �cs� t E -sn J• (t'+ rk. Louisiana-Pacific will assume no responsibility for any damage or condition arising from the use of rigid foam insulation sheathing - Trim or exterior gypsum. • Min. 3/16" gap Paint bottom 4" min. flashing edge of siding OVERLAP, Figure 1 ' 1" min. clearance . from roofing Space nail min. Y 4 3/4" from top LP Strand Substrate Lap Siding may also be installed in compliance with Sheathing, Breathable Category 8140- Exterior wall siding and sheathing for Wildland Unban �� w ' water-resistant Min. 1" if required Interface (WUI) applications atop LP FlameBlocl< sheathing. Refer to barrier overlap � FlameBlocl< installation instructions and product data sheets. All LP lap sidings !may be installed as exterior siding in Wildland Urban Interface Siding must not (WUI) alpplications installed over one layer 5/8" (16 mm) Type X gypsum Extend siding Ke, _; { contact masonry below sheathing applied behind the exterior covering or cladding on the exterior plate side of the framing. They may also be installed over the exterior portion of a 1-hourfire- resistive exteriorwall assembly designed for exteriorfire Min. 6" s R 4 finish grade exposure including assemblies using the gypsum panel and sheathing clearance ;;Z' products listed in the Gypsum Association Fire Resistance Design Manual. BU�J(03INTS Nail min. 3/4" from top and 3/8" from edge , • Butt joints must occur over studs. • A minimum 3/16 inch (5 mm) gap is required at ALL butt joints. • If joint caulking option is selected, seal all gaps at butt joints with a high -quality exterior sealant meeting the ASTM C920, minimum Class 25 sealant. • If joint moulding option is selected, add the thickness of the web to the gap allowing a net 3/16 inch (S mm) space for expansion, • If siding is prefinished, gap does not require sealant or joint moulding when backed with minimum 4 inch (102 mm) wide flashing and the ends of the siding are factory finished. The Louisiana-Pacific Corporation ("LP") LP SmartSide Siding (the "Products") limited warranty (the "Warranty") applies only to structures on which the Products have been applied, finished and maintained in accordance with the published application, finishing and maintenance instructions in effect at the time of application. The failure to follow such application, finishing or maintenance instructions will void the Warranty as to the portion of the Products affected by the variance (the "Affected Products"). LP assumes no liabilityfor any loss or damage sustained by the Affected Products and is expressly released by the purchaser or owner from any such loss or liability. Any modification of the Warranty's application, finishing or maintenance requirements is void unless approved in writing by LP priorto application. For a copy of the warranty or for installation and technical support, visit the LP SmartSide product support Web site at: WWw.lpsmartside.com or for additional support call 800-648-6893. WARRANTY REMEDIES ARE NOT AVAILABLE IF REQUyREMENTS ARE NOT FOLLOWED. WARNING: Drilling, sawing, sanding or machining wood products can expose you to wood dust, a substance known to the State of California to cause cancer. Avoid inhaling wood dust or use a dust mask or other safeguards for personal protection. For more information go to www.P6SWarnings.ca.gov/wood. SmartSide@ L,P TRIM & SIDING 02020 Lduisiana-Pacific Corporation. All rights reserved. LP and SmartSide are registered trademarks of Louisiana-Pacific Corporation. Printed in U.S.A. NOTE: Louisiana-Pacific Corporation periodically updates and revises its product information. To verify that this version is current, call 800-648-6893. I Figure IQ bottom course detail Figure 1 OE alternate inside corner details Gap 3/16" and seal Gap 3/15"J and seal f panel joint Figure 1 OD 6 in. minimum ,T-14. - ground clearance Figure 1 OC LPZ80512 04/09/2020 Admilk a ANORL■ ■ performance standards set forth in ]CC -ES AC321 and has achieved code recognition under ESR-1301, CCMC 11826-L, APA recognition under PR-N124, and HUD recognition under HUD -MR# 1318c. For copies of Product Approvals go online at https://Ip�orp.com/resources/product-literature/ or call LP Customer Support at 800=648-6893. • Strand Substrate panel siding with SilverTech or SmartFinish is specifically for sheds and other outdoor structures where the interior wall cavities will remain permanently exposed. • Minimum 6 inch clearance must be maintained between siding and finish grade (ground cover). • Siding applied adjacent to porches, patios, walks, etc. must have a clearance of at least 1 inch above any surface. • Minimum 1 inch clearance at intersection with roof line • Apply siding in a mannerthat prevents moisture intrusion and water buildup. All wood substrate that is exposed to the weather must be sealed in a manner that prevents moisture intrusion and water build up. - Seal ALL exposed cuts of siding and trim. Field spray applied coatings on cuts are not recommended. - Sealing can be accomplished by applying a coating or sealant according to the manufacturer's requirements. • All exposed wood substrate must be sealed in a manner that prevents moisture intrusion and water buildup. • LP does not recommend LP SmartSide Panel for use in ICF assemblies. If used, LP will not warrant for Buckling and Shrinkage. However, balance of warranty does remain intact. Use nails to fasten LP SmartSide panel siding to structural framing. The use of alternate fasteners such as staples is permissible only when allowed by I -Codes and where the size, embedment, placement, and number of alternate fasteners is designed by a licensed design professional and approved by local building official. The use of alternate fasteners, however, is not recommended and LP will not warrant any damage or performance failures to the extent caused by using any alternate fasteners. • SIDING MUST NOT BE IN DIRECT CONTACT WITH MASONRY, CONCRETE, BRICK, STONE, STUCCO OR MORTAR, '§TORAGE • Store off the ground well supported, on a flat surface, under a roof or separate waterproof covering STRAND SUBSTRATE 38,76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH Fr SMARTFINISH SPACINGSTUD • Strand Substrate 38 and 76 Series panel siding must be installed with the long dimension vertially on studs spaced max.16 inch o.c. When installing on 24 inch o.c. framing, 190 Series panel siding is required. MOISTURE • Moisture control and water vapor control are critical elements of proper housing design. Check your local building codes for application procedures for handling moisture and watervapor in your area. • When using wet blown cellulose insulation, the insulation must not be in direct contact with the siding and it must be allowed to dry a minimum of 24 hours or longer if specified by the insulation manufacturer. • As with all wood products, do not apply engineered wood siding to a structure having excessive moisture conditions such as drying concrete, plaster or wet blown cellulose insulation. If such conditions exist, the building should be well ventilated to allow it to dry prior to the application of the siding. Siding must not be applied to green or crooked structural framing members. Do not apply siding over rain -soaked or buckled sheathing materials. • Gutters are recommended for control of roof water run off. SECONDARYWRB I • LP 'strongly recommends the use of a secondary water -resistive barrier behind all LP SmartSide siding. A properly installed WRB provides a second line of defense to incidental moisture behind the siding. • The LP SmartSide limited warranty does not expressly or implicitly cover water penetration. LP does not assume responsibility for any water penetration. • Sheds and other accessory structures that are not heated or c09led do not require a secondary WRB if exempt by applicable building codes. GAPS & SEALANTS • Seal all gaps with a high -quality, non -hardening, paintable sealant. Follow the sealant manufacturer's instructions for application. • Use an exterior -quality, non -hardening, paintable sealant. Use Class 2S or higher exterior sealant meeting the ASTM C920 Standard for Specification for Elastomeric Joint Sealants. Follow the sealant manufacturer's instructions for application. • Keep siding clean and dry. Inspect prior to application. • Install kick -out flashing to direct the water into the gutter. • Install step flashing with minimum 4 inch (102 mm) upper leg. • Properly integrate flashing With the secondary water-resistant barrier. Use housewrap, flashing tape, Z-flashing, or other items as needed to maintain the counterflashing principle. • DO NOT extend the siding ort,rim into the kick -out flashing or gutter. • Maintain a clearance between the end of the gutter and the adjoining wall to allow for proper maintenance of the siding. • Seal ALL exposed cut edges. i LP Siding Min.1" clearance between siding and roofing APPLICATION INSTRUCTION5 tCONT.) • F;or best results use a high -quality 100% acrylic latex exterior paint, specially formulated for use on wood and engineered ujood substrates is highly recommended; oil paint is acceptable. DO'NOT USE: • Stain. • Vinyl -based paint (vinyl acetate or PVA). SMOOTH FINISH Lap Siding: • For best results use satin finish. CEDAR TEXTURE Lap Siding: • For best results use satin or semi -gloss finish. PREFINISHED Lap Siding: • Handle prefinished LP SmartSide lap siding with extreme care during storage and application. • Touch up any damage to finish that may occur during application per the Prefinishers specifications. ST I• , • LP SmartSide 38 Series lap siding may be attached directly to framing members spaced a maximum of 16 inches (406 mm) o.c. • LP SmartSide 76 Series lap siding may be attached directly to framing members spaced a maximum of 24 inches (610 mm) o.c. • Check your local building codes before starting to install siding to confirm if wood structural panel wall sheathing is required. • Butt joints should be staggered over successive courses. • Siding shall be installed with top (blind) nailing, with the nails Clean rain placed 3/8 inch (10 mm) from either end and a minimum of gutter 3/4 inch (19 mm) from the top edge of the board. Fasteners will be exposed on siding located immediately below window sills, fascia boards, and horizontal trim. Fasteners below windowsill r- shall be spaced a maximum of 8 inch (203 mm) o.c. do not run siding or trim inside • Overlap successive courses of'siding a minimum of 1 inch (2S mm). of the kick out flashing . Use a minimum (0.113 inch shank diameter), hot -dip galvanized nail. • Trim should be thick enough so the lap siding does not extend beyond the face of the trim, • Trim and fascia must be applied in a manner that will not allow ; Self-ali moisture intrusion or water buildup. rabbet • LP° SmartSide° siding is not designed and/or manufactured to be used as trim. - LP SmartSide trim and fascia are available in a variety of 1" overlap dimensions. • Seal all exposed surfaces, Including all drip edges or where water will hang. • Apply finish coat as soon as possible or within 180 days of application. • Follow the coating manufacturer's application and maintence instructions. SmartLock Lap Blind Fastening 3/4" nail spacing Install SmartLock Lap consistent with specifications in this document APPLICATION INSTRUCTIONS (CONT.) CONDITION CORRECTION Snug ®i OK Flush � OK Visible fiber 0 Paint Countersunk 1/16"-1/8"_ (a Apply sealant Q Countersunk more Apply sealant and — than 1/8" , re -nail • All exposed face nails must be caulked and sealed in a manner that prevents moisture intrusion and water buildup. • Penetrate structural framing'or wood structural panels and structural framing a minimum of 1-1/2 inches (38 mm). • Nail from the center of the siding toward the ends, or from one i end to the other end. NEVER nail from the ends of the siding toward the middle. t • Shim siding at studs as needed, to avoid drawing siding against i uneven walls. Do not overdrive nails. Nail head should seat firmly to face of siding but not be overdriven to distort the siding surface. i • For information on fastening LP SmartSide products in high wind speed areas, referto ICC-ES Report ESR-1301 or APA PR-N124. i Alternative Fastening Option for Strand Lap Siding over Wood Structural Panels and 24 inch (610 mm) o.c. Stud Spacing • Limited to 6 inch (152 mm) and 8 inch (203 mm) wide lap siding. • Wood structural panels must be a minimum 7/16 Category with an APA Trademark that contains the consensus Standard DOC PS 2. • 38 Series Strand Substate lap must be fastened with: - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of 12 inches (305 mm) o.c. with 1-1/2 inch (38 mm) screw penetration into stud or... - Minimum (0.092 in. shank diameter) hot -dip galvanized ring shank nail, spaced a maximum of 8 inches (203 mm) o.c. with 1-1/2 inch (38 mm) nail penetration into stud. Alternative Fastening Options over SIP Assemblies • Wood structural panels must be a minimum 7/16 Category with an APA Trademark that contains the consensus standard DOC PS 2. • 38 Series Strand Substrate lap must be fastened with: - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of12 inches (305 mm) o.c. or... - Minimum (0.092 inch shank diameter) hot -dip galvanized ring shank nail, spaced a maximum of 8 inches (203 mm) o.c. • 76 Series Strand Substrate lap must be fastened with: - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of16 inches (406 mm) o.c. or... - Minimum (0.092 inch shank diameter) hot -dip galvanized ring shank nail, spaced a maximum of12 inches (305 mm) o.c. Alternative Fastening Option over ICF Assemblies - Minimum #8 hot -dipped galvanized, tapered head, self -drilling screw. - Minimum penetration of 3/8 inch (10 mm) beyond the thickness of the nailing flange. - Larger screws may be required bythe ICF Manufacturer based on the following minimum withdrawal requirements. • Minimum withdrawal value of the ICF nailing flange must be 50 lbs. with a maximum 12 inches (305 mm) o.c, screw spacing. • Minimum withdrawal value of the ICF nailing flange must be 31 Ib's, with a maximum 6 inches (152 mm) o.c. screw spacing. Alternative Fastening Options over Corrosion Resistant Steel Stud Framing • Minimum withdrawal value of the steel framing must be SO lbs. Refer to the framing manufacturer's evaluation report. 38 Series Strand Substrate lap must be fastened with: - Stud spacing a maximum spacing of 16 inches (406 mm) o.c. -,Minimum #8 hot -dip galvanized, tapered head, self - drilling screw. - 'Minimum of 5 threads beyond the combined thickness of :the siding and steel stud framing. - !Minimum steel framing thickness of 0.032 inch (8 mm) or 20 gauge. 76 Series Strand Substrate lap must be fastened with: - !Stud spacing a maximum spacing of 24 inches (610 mm) o.c. - iMinimum #8 hot -dip galvanized, tapered head, self - ;drilling screw. -'Minimum of 5 threads beyond the combined thickness of the siding and steel stud framing. - Minimum steel framing thickness of 0.032 inch (8 mm) or 20 gauge. CAUTION • Do riot force siding into place. • DO NOT USE STAPLES. • Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prefinished surface. • Where siding butts window trim, door casings and masonry, etc.,leave a 3/16 inch (5 mm) gap and seal. Insulated Sheathings LP SmartSide lap sidings may be installed over low -compression, rigid foam insulation sheathing or exterior gypsum. The following preca I tions must be followed: • Adequate bracing of the wall in accordance with the International Building Codes or other ruling building codes is required. • For rigid foam insulation sheathing up to 1 inch (25 mm) thick, siding may be nailed directly to the foam sheathing unless a drainage plane is required by the local building code. Nail length must be increased to ensure a minimum 1-1/2 inch (38, mm) fastener penetration into the structural framing. • For; rigid foam insulation sheathing greater than 1 inch (25 mm), a minimum 1-1/2 inches (38 mm) thick by 3-1/2 inches (89 mm) wide vertical strap or furring strip must be installed over the • 38 and 76 Series Strand Substrate Lap must be fastened with: "PA!�ELSIDIMG 16INT C YORIZONTP 1For multi -story buildings, ma ifor "setting" shrinkage of fra i i BAND BOARD over PANEL FILLER BELTLINE JOINTS provisions at horizontal joints ng, especially when applying Panel siding 3/8" gap Sloped flashing with 4" vertical leg 2"x Band board Filler Board — Panel siding Figure 6 SILL PLATE OPTIONS, Extend siding below sill plate Min.1/8" or / flashing between siding and masonry Figure 7A ashing Masonr foundati GAP, FLASH'DOORS & WINDOWS Interior Finish Install window/door per manufacturer's instructions Figure 8 Figure 713 Siding 3/8" gap Sloped flashing — 4" vertical leg '-Trim '*"' Nail fin (do not damage) 4 FT. X 8 FT. U'NGRO,OVED SHIPLAP PANEL widthFiaure 9 Scant face s SPACE JOINTI/8" Refer to nailing instructions 1/8" gap 1/8" gap LP panel sidings are accepted by the State of California as category 8140- Exterior wall siding and sheathing for Wildland Urban Interface (WUI) applications. For WUI compliance, install LP panel sidings in accordance with Louisiana-Pacific's printed application instructions with the addition of fire retardant seal (UL Listed fire caulk, nominal 1/4 inch bead) in the vertical joint and nailing pattern of 3 inch o.c. perimeter nailing / 8 inch o.c. field nailing. Look for the California State Fire Marshal Office label on our siding. The Louisiana-Pacific Corporation ("LP") LP SmartSideSiding (the "Products") limited warranty (the "Warranty") applies only to structures on which the Products have been applied, finished and maintained in accordance with the published application, finishing and maintenance instructions in effect at the time of application. The failure to follow such application, finishing or maintenance instructions will void the Warranty as to the portion of the Products affected by the variance (the "Affected Products"). LP assumes no liability for any loss or damage sustained by the Affected Products and is expressly released by the purchaser or owner from 4iny such loss or liability. Any modification of the Warranty's application, finishing or maintenance requirements is void and unenforceable unless approved in writing prior to application by the Siding General Manager or his designee and a member of the LP Legal Department. For a copy of the warranty or for installation and technical support, visit the LP SmartSide product support Web site at: i www.Ipsmartside.com or for additional support call 800-648-6893. i WARRANTY REMEDIES ARE NOT AVAILABLE IF REQUIREMENTS ARE NOT FOLLOWED. Cal. Prop 65 Warning: Use of this product may result in exposure to wood dust, known to the State of California to cause cancer. I LP SmartSide@ I TRIM & SIDING 02020 LIPuisiana-Pacific Corporation. All rights reserved. LP, SmartSide, SllverTech and SmartFinish are registered trademarks of Louisiana-Pacific Corporation. Printed in U.S.A. NOTE: Louisiana-Pacific Corporation periodically updates and revises its product information. To verify -that this version is current, call 800-648-6893. APPLICATION INSTRUCTIONS (CONT.) Over Openings Ensure complete paint coverage of the drip edge Flash, shim, E gap;3/8" Figure 3A Vapor Retarder if required by code IJII�1 Water - Resistant Barrier Alternate Butt joint Treatments joint Moulding Caulked Butt joint Gap 3/16", plus;thickness 3/16 in. of joint moulding web Gap 3/16" III and seal Figure 3B 6 n. Q..... a 3E ' I gap 3/16" and seal Figure 3C Figure 3D gap 3/16" and seal