Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL HORIZONTAL SLIDERSI .#�13w=e i 3 3 d�'K 5 1.1.'J. .r5 y x' 4 ' 4YS' i^.s. r f°`. ■eF�y FILE �OPI( BCIS Home Log'.In I User Registration Hot Topics Submit Surcharge Sti is & Facts Publications ( Contact Us .': BCIS Site Map I Links ; Search i Product Approval USER: Public User Product Approval Menu > ProduR or Application Search > Application Llst > Application Detail FL # FL20743-R2 Application Type Affirmation Code Version ZUZU Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC ZZ� L —7 TAFCO Corporation 1953 N. 17th Ave Melrose Park, IL 60160 (773) 301-7778 mike@tafco.com Lucas Turner Luke@TurnerEC.com Windows Horizontal Slider Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 'Evaluation Report - Hardcopy Received Lucas A. Turner PE-58201 06/17/2026 Scott Wolters, PE ,Validation Checklist - Hardcopy Received FL20743 R2 COI EvalReportFPA-82000.pdf standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 i I affirm that there are no changes in the new Florida Buildino Code which affect my product(s) and my product(s) are it Compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity I Product Approval Method Date Submitted Date Validated Date Pending.FBC Approval Date Approved ary oflP Yes No 'N/A l FL20743 R2 COC 7thEdFBC-FL20743.pdf i Method 1 Option D 01/27/2021 01/2i7/2021 02/Q4/2021 FL # Model, Number or Name liDescription 20743.1 Series 82000 j,PVC Horizontal Sliding Window Limits of Use I Installation Instructions Approved for use in HVHZ: No j FL20743 R2 II FPA-82000.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner PE 58201 Impact Resistant: No ( Created by Independent Third Party: Yes Design Pressure: N/A ('Evaluation Reports Other: Please see installation drawing and evaluation report FL20743 R2 AE Eva lReportFPA-82000.pdf for additional details and limits of use. j Created by Independent Third Party: Yes s;711- . 0 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to. a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the pI ublic. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® s:heck Credit• ae sewrit:vmFirr S SERIES 82000 HORIZONTAL SLIDING WINDOW, NON -IMPACT TABLE 1. DESIGN PRESSURE RATINGS GLASS DESIGN PRESSURE RATING IMPACT RATING 1/8"-1/8" I.G. +30/-30 PSF .NONE ANNEALED MINIMUM 5/32"ANNEALED +20/-20 PSF NONE MINIMUM SHEET DESCRIPTION 1.............ELEVATION, GEN. NOTES Z........... SECTION DETAILS 3............ ANCHORAGE DETAILS, NOTES 4............ 9.O.M., JOINERY, PART DRAWINGS :2a 63" MAX. OVERALL WIDTH 0 27 11/16" MAX. -28 5/16" MAX: X w- SASH D.L.O. WIDTH FIXED D.L.O. WIDTH 14" 4" MAX. FROM MAX. O.C. CORNER, TYP. TYp x H 2 = w � x = o J J � n o vai _ 2 3 2 x 4 0 Nv J L] 0 x M 0 I INSTALLATION FASTENER LOCATION, TYP., SEE SHEET 3 2 Za 0�7_ ,<w r eo w .0 Lucas A: Tumer-- 1 2016-06-17 11:18=04:00 J SILL ANCHOR SPACING SAME EXTERIOR ELEVATION AS HEAD GENERAL NOTES 1. THIS PRODUCT, FABRICATED AND ANCHORED AS DETAILED IN THIS DRAWING, IS NON -IMPACT. RESISTANT AND REQUIRES THE USE OF IMPACT PROTECTIVE DEVICES (SHUTTERS) IN WINDBORNE DEBRIS REGIONS. 2. THIS PRODUCT HAS BEEN TESTED TO AAMA/WDMA/CSA 101/I.S.2/A440-OB/11, AND MEETS THE REQUIREMENTS. OF THE FLORIDA BUILDING CODE, 5TH EDITION (2014), NOT INCLUDING THE HIGH VELOCITY HURRICANE ZONE. PRODUCTS SHALL BE CONSTRUCTED AS INDICATED IN INTERTEK/ATI REPORTS F5086.01-109-44-RO AND F9644.01-109-44-RO; FOR DETAILS NOT SHOWN IN THIS DRAWING SEE REPORTS. 3. ALLOWABLE CONFIGURATIONS: XO (OPERABLE/FIXED) OR OX (FIXED/OPERABLE) 4. THE DESIGN PRESSURE RATINGS AS SHOWN IN TABLE 1, THIS SHEET, ARE AS LIMITED BY ASTM E-1300 04 GLASS TABLES, AND TESTED WATER AND STRUCTURAL PRESSURES. OTHER GLASS, ANNEALED OR TEMPERED OF GREATER OR EQUAL THICKNESS TO THOSE NOTED IN TABLE 1, WHICHIMEETS ASTM E 1300 REQUIREMENTS FOR EACH PROJECT, MAY BE USED. 5. THE 4/3 ALLOWABLE STRESS INCREASE FACTOR (SHORT-TERM INCREASE FACTOR) HAS NOT BEEN USED IN THE ANCHOR ANALYSIS FOR THIS SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF ANCHORAGE INTO WOOD SUBSTRATE. 6. 'INSTALLATION OF WOOD BUCKS TO THE SUBSTRATE TO BE ENGINEERED BY OTHERS OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION (A.H.J.). BUCKING, OPENINGS, & BUCKING FASTENERS MUST BE PROPERLY DESIGNED & INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO TRANSFER SUPERIMPOSED LOADS*TO THE STRUCTURE. ADEQUACY OF THE STRUCTURE TO RECEIVE THESE LOADS SHALL BE VERIFIED BY THE CONTRACTOR OR A.H.J. 7. DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE COATED OR OTHERWISE PROTECTED PER FBC CHAPTER 20 TO PREVENT GALVANIC REACTIONS. WOOD BUCKS, IF USED, SHALL BE PRESSURE TREATED, WITH EITHER A TREATMENT OR COATING COMPATIBLE WITH THIS PRODUCT. ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL OTHER WINDOW MATERIALS. 8. ALL HARDWARE & FASTENERS .SHALL BE IN ACCORDANCE WITH THESE DRAWINGS, OR AS APPROVED; SIGNED, AND SEALED BY A FLORIDA-REGISTERED PROFESSIONAL ENGINEER ON A SITE -SPECIFIC BASIS. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER INFILTRATION. RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE RESPONSIBILITY OF OTHERS AND IS NOT ADDRESSED BY THIS DOCUMENT. .Z; t No 58201 'P ro= tT 9E STATE OF r 6/17/2016 LUCAS A. TURNER, P.E. FL PE # 58201 TURNER ENGINEERING & CONSULTING, INC. (COA # 29779) 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574' J z O C) 0 N 00 O O (n = z W W V, DRAWN By'. LAT DATE: 6/15/16 SCALE: NTS REVISON: REVISION: DRAWING 9 FPA-82000 SNEET DESCRMON NOTES, ELEVATION SHEET 1 of 4 3/4" I.G. N TYP. I.G. AIR GAP m GLAZING ANN. 1/8" ANN. caw DETAILK GLASS MIN. GLASS MIN. lW a22 TYPICAL VERTICAL SECTION 2 4 2 2 2 2 TYPICAL HORIZONTAL SECTION V)w �m 5/32" ANN. Ld GLASS MIN. �0 SILICONE 7 TYPICAL SINGLE GLAZING DETAIL z O O 0 O F z °'I J DO _ cD FYI O_o._�-_ za00 O rn o Of Q � J z�O OHO N N F 00 L7 (f) =zW J p Fr W •� — Pr`" �" • r -�� DRAWN 9Y: DAM * *= 6/15/16 S ... 9p: STATE DF �. 41 NITS •4�F•;:CotOPr�e p In, RENSgN: REYISpN: 6/17/2016 DRAWNG FPA-820DO LUCAS A. TURNER, P.E. SHM DESCmonoN FL PE # 58201 SECTION TURNER ENGINEERING & DETAILS CONSULTING, INC. (COA # 29779) 1239 JA6ARA AVE. SHEET NORTH PORT, FL 34288 2 Of 4 PH. 941-380-1574 1-1/2" MIN. EMBED. BUILDING SHEATHING AND WRAP BY OTHERS SEALANT BEHIND FIN BY INSTALLER, FULL PERIMETER GENERAL ANCHOR NOTES: 1. INSTALL ONE ANCHOR AS SHOWN ABOVE AT EACH LOCATION SHOWN IN THE ELEVATION ON SHEET 1 FOR PRODUCT PERIMETER. 2. INSTALL SHIMS AT EACH ANCHOR LOCATION WHERE A GAP OF 1/16" OR GREATER EXISTS BETWEEN PRODUCT FRAME AND SUBSTRATE. 3. SHIMS SHALL BE LOAD -BEARING (PLASTIC OR METALLIC) AND CAPABLE OF TRANSFERRING LOADS TO SUBSTRATE. 4. SPECIFIED ANCHOR EMBEDMENT TO WOOD SUBSTRATE SHALL BE BEYOND SHEATHING, WALL FINISH OR STUCCO. 5. THE INSTALLATION DETAIL SHOWN IS ALSO APPLICABLE FOR INSTALLATION TO WOOD BUCKS INSTALLED OVER CONCRETE/MASONRY, WITH ATTACHMENT OF 2X TO CONCRETE/MASONRY BY OTHERS. SPRUC/PINE/FIR MIN. WOOD SUBSTRATE BY OTHERS z V- �o nw 1 \iVa SEALANT BY rn INSTALLER, FULL PERIMETER INSTALLATION FASTENER, #8 PAN HEAD WOOD SCREW, SEE LOCATIONS SHEET 1 TYPICAL INSTALLATION HEAD, SILL, AND JAMB z CD O `° Lj 0 Q ¢ N N O I- z �rJ00 J = lO .Z d DO O Ln�_ LE- - J Q Lij J Z O OZO N _y N > DD O O Cf) = Z w J � W ,400, NO REtiu , DRAWN BY. E G �., SJGPS•4�o �SF••;Q'�••. • LAT � � mot• No 562O1 •shyp 6/15/16 9Q; STATE OF NTS •:4r�u ���{{•••� Ai , NEMSION: RMSION: DRAWING 6/17/2016 FPA-82000 LUCAS A. TURNER, P.E. FL PE # 58201 SHE-..RPIION TURNER ENGINEERING & INSTALLATION DETAILS CONSULTING, INC. (COA # 29779) 1239 JABARA AVE. SHEET NORTH PORT, FL 34288 3 Of 4 PH. 941-380-1574 j 82000 SERIES WINDOW BILL OF MATERIALS ITEM NO. DWG. NO. NAME MATERIAL. DESCRIP. 1 HMST82-01. MAIN FRAME PVC EXTRUSION 2 HMST82-03 SASH PVC EXTRUSION 3 HMST82-05 LOCKED SASH PVC EXTRUSION 4 HMST82-06 INTERLOCK PVC EXTRUSION 5 HMST82-07 TRACK PVC EXTRUSION 6 HMST130-10B IG GLASS BEAD PVC EXTRUSION 7 HMST130_10A- SINGLE -GLASS -BEAD _ _PVC EXTRUSION 1.280" [32.501 o Q DO 0 o (MD L Q O u 4 INTERLOCK HMST82-06 3-22R" OMAIN FRAME HMST-82-01 1.161" 1,161" r [29.50] [29:50] 0 i- Lq u 1 g tom. mo ` o 4 Qou SASH LOCKED SASH 2-----HMST82-03 9--HMST82-:05'- 1.346" [34.201 5 TRACK HMST82-07 z O wo Q Q N 0O � za�lI �r- �ro J_ O a:(D I -- oQ1 zaCO 0Lno[L LL O! J Ld J Q O zoo 0 z O N_ — O' y� o0 0 V) _ = W JpE w - - -- - - --- - z- V)— ,`,t • PNU RC Vy ';, ,a DRAWN BY: '�B ElyLAT r No 58201 •SS. v ; DATE: Ln _ 1.004" =�F *� 6/15/16 oaq u [25.50] SCALE %V. STATE OF .•.W4 NTS K) EDD 0'�� O R 1 �P ••���REASON: LO 0.067" ao O u REMSPON: r : DRAN7NC / 0 6/17/2016 FPA-82000 A. TUER,IG GLASS BEAD SINGLE GLASS BEAD LUC FL PE # 58201P E SHEET Pf O HMST130-10B O HMS r130-1 OA TURNER ENGINEERING & BOM, MP PART CONSULTING, INC. DWGS, CORNE (COA # 29779) 1239 JABARA AVE. SHEET NORTH PORT, FL 3428E 4 of 4 PH. 941-380-1574