HomeMy WebLinkAboutWindow & Door Opening InformationA FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone - 10% of least horizontal dimension or 40% of the mean roof height, whichever is smaller, but not less than 4% of least horizontal dimension or 3 ft.
OPENING
LOCATION
NUMBER
(Location)
Corner Zone
or Interior
IS THIS A
WINDOW
OR DOOR
GLAZING
TYPE
PRODUCT
ACCEPTANCE
NUMBER
PRODUCT APPROVAL
APPROVED PRESSURE RATING
REQUIRED OPENING
DESIGN PRESSURE
MAXIMU
M
TESTED
SIZE
ROUGH
OPENING
DIMENSIONS
MULTIPLE
WINDOW
ARE
SHUTTERS
REQ Y/N
(+) PSF
(-) PSF
(+) PSF
(-) PSF
MULLION
REQ Y/N/NA
1
Int
Window
7/8" Lami
20-1103.09
55
55
37.1
-40.3
74 x 63
5207
No
No
2
End
Window
7/8" Lami
20-1103.09
55
55
35.0
-45.0
74 x 63
73x62
No
No
3
End
Window
7/8" Lami
20-1103.09
55
55
35.0
-45.0
74 x 63
73x62
No
No
4
End
Window
7/8" Lami
20-1103.09
55
55
35.0
-45.0
74 x 63
73x62
No
No
5
Int
Window
7/8" Lami
20-1103.04
55
55
34.0
-37.2
111 x 63
110x62
No
No
%®
c;
r
r
A �
i'ri 1
e� esi
�u
® M,
N
I=
I�
RECEH ED
IGHT500 SW 12th Ave ® /22
Deerfield Beach, FL 33442
DOWS
ST. Lucie County, i'•�rinitting
Ph.561-922-6747
WINFax. 561-292-3562
Information
Owner: HALEY & LOGAN MCDANIEL
Address: 121 RIOMAR DR
PORT ST. LUCIE, FL 34952
Buildinia Information
Wind Zone: 170 MPH.
Exposure Category: C
Minimum Building Dimension: 40 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)F
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psfl
1
Int
52 37 7
37.1
-40.3
2
End
73 62 7
35.0
-45.0
3
End
73 62 7
35.0
-45.0
4
End
73 62 7
35.0
-45.0
5
Int
110 62 7
34.0
-37.2
Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads -Components and Claddl3tg.
Page 1 of 1
Code.