Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTIM ..f ]F'(>'rce Engineering 41: 'Testing 19530 Rumblewood Drive 11LIHIle, Texas 77.11.18 Phone: (401)54("603 FAN: i;:31)540.9966 Website: rvww.rorceengineerlcie_,testing.com Product Evaluatiori Report TRI COUNTY METALS FILE COPY REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC 2Zp3��33 26 Ga. FSR Wall Panel over open framing Florida Product Approval # 9901.1 R4 Florida Building Code 2020 Per Rule 61G20-3 Method: 2 —B Category: Structural Components Subcategory: Structural Wall Compliance Method: 61G20-3.005(2)(B) NON HVHZ Product Manufacturer: Tri County Metals 301 SE 16th Street Trenton, Florida 32693 Engineer Evaluator: Johnathan Green, P.E. #88223 Florida Evaluation ANE ID: 12901 Validator: Brian Jaks P.E. #7tl;1159 Contents: Evaluation Report Pages 1— 4 W119901pp 0 � ,yam o w o B fg z P -m P P ° OCT 012010 ®�®je� �A �� THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. FL# 9901.1 R4 Force Engineering 'Te;tang 19530 Ranebleu'ood Drive Humble, Texas 77338 Phone: (281)54i1-6603 FAX: (281}54111-9966 'rO�CiJSi�[:: L414'w.Porcecnl;inceringtestiiio�;.conro FILE COPY REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC 7-7-03 — 4;P-715, Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2020, Sections 1709.2. P � -.J> 42 - e/ZI Product Description: PBR Wall Panel, 26 Ga. Steel, 36" Wide, through fastened structural structural wall panel. Structural Application. Panel Material/Standards: Panel Dimension(s): Panel Fastener: Substrate Description: Allowable Design Pressures: Material: 26 Ga. Steel, panel material shall comply with Florida Building Code 2020 Section 1405.2. Yield Strength: Min. 50,0 ksi Thickness: 0.0185" min. Width: 36" maximum coverage Rib Height: 1-1/4" major rib at 12" O.C. #12-14 x 1-1/4" HWH SD with sealing washing or approved equal at 12"-12"-12" fastener pattern. Panel side laps fastened together w/ %-14 x 7/8" HWH SD w/ sealer washer at 20" O.C. Corrosion Resistance: Per Florida Building Code 2020. Min. 16 Ga. Steel Framing. Framing must be designed in accordance w/ Florida Building Code 2020. Table "A" Maximum Design Pressure: -45.0 psf +55.0 psf Fastener Pattern: 12"-12"-12" 12"-12"-12" Fastener Spacing: 5'-0" O.C. 5'-0" O.C. *Design Pressure includes a Safety Factor = 2.0. Q®q�866888Psggp AGf+g�NV®®® a 0 D C m e- aPI£C zi�� OCT 01 2020 AL PQ THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. FL# 9901.1 R4 FILE COPY Code Compliance: Evaluation Report Scope: 7��Le Engineering & Tmn:4ing W30 Rumblewood Drive REVIEWED FOR CODE COMPLIANCE ll540-66Terns : (2 ST. LUCIE CQUNTY BOCC Phone: 12t311 S4(1•G403 I�A`C: (281) b-0lt•99(i(i wcbsEtlrr: www.forceeuginccringl�xlfim�;•cmn �� � 2�1�L The product described herein has demonstrated compliance with The Florida Building Code 2020, Section 1709.2. The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2020, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ■ ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference. Reference Data: 1. ASTM E 1592-01 Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 136-0393T-07 2. Certificate of Independence By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing (FBC Organization # ANE ID: 12901) Test Standard Equivalency: The ASTM E 1592-01 test standard is equivalent to the ASTM E 1592-05 (2012) test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. ��Q�9�E6@dr✓9dd 0. 6 Pao emu otoo w o r � e a r e O OCT 01 2020�®�e� 0A11e THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. FL# 9901.1 R4 Force Engineering & T'e„Bing 19530 Ramblewood Drive 11umble, Texas 77333 Phonc1 12R11 940.64113 VA MRli C911 996t FILE COPY REVIEWED FOR CODE COMPLIANCE �LUCIE 1;*,'OUNTY BOCC Web,Ocn wivw.forecengincerin;,4eslinl;.com F Design Procedure: Based on the dimensions of the structure, appr late wind loads are - determined using Chapter 16 of the Florida Building Code 2020 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2020 Chapter 22 for steel, and Chapter 16 for structural loading. °f 0NO 8=3 , % c WATECW .a e OCT 012020 �8/e® AL Bripa116� THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. FL# 9901.1 R4 Force E1nginee>9°i�,ng & Testing 19530 Munbbewood Drive humble, Texas 77338 Pbouc: (281) 540-6603 FAX: (281) 540-9906 01'ebsite: www.f'orceeurtineeringtesting.com 26 Ga. PBR Wall Panel over open framing FILE COPY REVIEWED FOR CODE COMPLIANCE ST. LUC9E COUNTY BOCC Zza3 -, o If1-5 12" 12• 12" ®201 X 7/8 LAP TEK #12-14 x 1 1/4 M w/ WASHER TYPICAL FASTENER PATTERN 1/4-14 X 7/e 1AP TEK 7' 5' 7" 5' 7" 51 0 20 O.C. 012^14 x 1 1/4 HWH w/ WASHER FASTENER PATTERN AND AT ALL PANELS END LAPS AND PANEL ENDS ��@9�99BB�sgp�, dp6GEq��.a d® Ab MW eo.�r�s �'• a cr o o OMMOF ° Z i 'OR 0�� a6 OCT 012020 1i� ���® THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. INTED COPIES OF THIS ,CUMENT ARE NOT ,NSIDERED SIGNED AND ALED AND THE 'NATURE MUST BE RIFIED ON ANY CTRONIC COPIES. FL# 9901.1 R4