Re: Verification Testing & Inspection
Dear Mr. Lupton:
F IF f--, pn
Life Saver Pool. Fence Systems, Inc. retained Nutting . Eirigineers of Florida Inc. to test- Life
Saver's D110X-6 and 8117X-6 Product lines to verify their conformity with applicable ASTM
Standards and Section R4501.17.1.15'No. 2 of the 2020 Florida Building Code.
The test specimens :consisted of fifteen (15) foot sections of representative safety fencing. The
section tested measured forty-eight (48) inches high for the D1'10X-6 Product and (60)' inches
high for the S117X-6 Product. They were installed with horizontal spacing of thirty-six (36)
inches. The representative samples were installed' as per the ASTM Standard F-2286-16
Section 4.
We have completed _the performance tests for vertical Load and impact testing in our facility
based on the noted ASTM Standard as well as reviewing test results .from Twitchell
Corporation and TexTest.
Conclusion:
Based on our testing and the information provided to us for review the products were found to
meet all minimum requirements puff forth by ASTM D5034-95, ASTM D3787-01, ASTM G53-
96, ASTM F-2286-16, and Section R4501.17.1.15 No. 2 of the 2020 Florida Building Code
Sincerely