HomeMy WebLinkAboutBUILDING PLANSAINT LUCIE COUNTY, FL • TUR PIKIH. FEEDER ROAD FORT • •' CE, FIL r ., 60 BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL_.. DATA OPENING SCHEDULE: EXTERIOR SWING DOORS, OVERHEAD DOORS, SLIDING GLASS DOORS, FIXED GLASS, AND WINDOWS PRODUCT DESCRIPTION MODEL MANUFACTURER GLASS ATTACHMENT METHOD PRODUCT DESIGN BUILDING DESIGN ' PRODUCT NUMBER DESCRIPTION -TYPE, SIZE, SPACING & EMBEDMENT PRESSURES (PSF) PRESSURES (PSF) APPROVAL NO. OVERHEAD MODEL 9505 WAYNE-DALTON N/A (3) %la`" X 1-%" LAC SCREWS PER BRACKET T-2 -28..8 SEE ELEVATIONS FL #9174.4 GARAGE DOOR OUTSWING DOUBLE DESIGN PRO JELD-kWEN IMPACT 3(a" x 1Y4" MIN. EMBED. TAPCONS 0 25" O.C. MAX. +/-50.0 SEE ELEVATIONS FL #16674.4 ALUMINUM FRENCH DOOR SMOOTH PRO WINDOWS 1 DOORS SINGLE DOOR OPAQUE THERMA-TRU IMPACT Y4" x 1Ya MINIMUM EMBED. TAPCONS AT 14.5" O.C. MAX. +/-55.0 SEE ELEVATIONS FL #23957.7 FIBERGLASS ALUMINUM SERIES 3200 LAWSON IMPACT " x " MINIMUM IMUM EMBED. TAPCONS A7 1O.C. MAX. Y47Yc +/-59.0 SEE ELEVATIONS NOA #20-0814.07 CASEMENT WINDOW INDUSTRIES, INC. T FIXED WINDOW SERIES 4200/6200 LAWSON INDUSTRIES, INC. IMPACT A"x 1Y4D.C.=+/-68.0 MINIMUM EMBED. TAPCONS AT 12" D.CSEE ELEVATIONS NOA #20-0814.09 MODEL ATTACHMENT METHOD PRODUC I DESIGN BUILDING DESIGN PRODUCT PRODUCT DESCRIPTION NUMBER MANUFACTURER TYPE, SIZE, SPACING & EMBEDMENT PRESSURES (PSF) PRESSURES (PSF) APPROVAL NO. METAL ROOF 5-V CRIMP EXTREME METAL FABRICATOR, LEG #10x1Y2" HEX -WASHER HEAD SCREWS 0 15' O.C. -93.5 PSF SEE ELEVATIONS FL# 17022.1 ROOFING UNDERLAYMENT 4.13 RESISTO SUPREMA, INC. SELF -ADHERING +/-150 SEE ELEVATIONS FL# 2569.1 LB1236 HURRICANE SHUTTERS N/A SOFFIT COVERING TO BE BUILT ON -SITE USING: 3/8°" HI -RIB SELF FURRED EXPANDED METAL LATH `WITH 'K-PAPER" BACKING (CEMCO; 3.4 LBS/SQ. YDS, MEETING ASTM C847) FASTENED TO EACH ROOF TRUSS WITH NOT O0 NOT APPLICABLE SOFFIT COVERING STUCCO STUCCO #8(MIN) x 1 1/4" PHILLIPS PAN/TRUSS HEAD SCREWS (1EI S.S. OR GALV. ASTM A307 STEEL) SPACED 5" APPLICABLE L ZONE WAL ZONE (WAL 5) (FBC-R616.4 & O.C. MAX (2 SCREWS PER EA. SO. FT. OF LATH). 5/8" THICK MIN. CEMENT STUCCO MIXED AND APPLIED IN R703.1.1) CONFORMANCE WITH ASTI C926. 1. ALL GLAZED EXTERIOR OPENINGS SHALL BE IMPACT OR PROVIDED WITH SHUTTERS. 2. MAIN EGRESS DOOR MUST BE IMPACT RESISTANT. i 3. 'WINDOW AND DOOR FENESTRATION SHALL BE IN ACCORDANCE WITH FBC R703.4 (1.2) AS PER DETAILS PROVIDED I HAVE REVIEWED THE ABOVE PRODUCT APPROVAL INFORMATION AND APPROVE IT. NAME: BRIAN MASKOL, P.E. CERTIFICATE NUMBER: 66080 1. DESIGN LOADS IN ACCORDANCE WITH ASCE 7-16. 2. SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3. ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4. SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1 Y" SUSPENDED SLABS: 1 'Yi" 6. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 9. UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICES. 10. LINTELS SHALL HAVE A MINIMUM 41' BEARING. 11. PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM. 12. STUCCO CEILINGS AND SOFFIT NOTE: EXTERIOR CEILING AND SOFFIT TO BE STUCCO OVER WIRELATH W/ 110A. 2" NAILS W/ 3/8" 0 HEAD 0 6" O.C. OVER 3/8" METAL RIB LATH ® 6" O.C. W/ (2 LAYERSOF 15# FELT OVER EACH FRAMING MEMBER). 13. EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH 3/8" 0 HEAD ® 6" Q.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 19/32" COX PLYWOOD WITH 10D NAILS TO STUDS ® 6" Q.C. PERIMETER AND FIELD. 14. BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE BEARING MEMBER IS (2) OR MORE PLIES UNLESS NOTED. WALL FINISH/INSULATION NOTES 1. INTERIOR TO BE A" DRYWALL FINISH. 2. ALL INTERIOR GYPSUM BOARD TO BE MIN. Ye" THICK WITH (13 GAGE, 1 3/8" LONG, 19/64" HEAD; 0.098" DIAMETER, 1 9" LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG, 15/64" HEAD; OR GYPSUM BOARD NAIL, 0,086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS AND 12" O.C. FOR SCREWS. 3. WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). 4. WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. 5. WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. B. ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC316. 7. PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 4-15. C 514. C 630, C 931. C 960, C 1002, C 1047, C 1177, C 1178. C 1278, C 1395. 0 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557. S. INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. a r ^'."W Planning &Development Services Department j5.: I` Building & Code Regulations Division k 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1577 L' Certification for Design Load Compliance 71h Edition Project Name: OCCHUIZZO RESIDENCE TURNPIKE FEEDED RD Permit #;____ Occupancy Type;_B__ ConstructionType: V • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies withal) pertinent information. St Lucie Fire Dietdct requires a digitally signed electronic version. • if submittirgelectionicaliy, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document format (PON version • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGNCODE: Flonda_...RUIL DIp.G­Code 7th Edition using ASCE 7-16 2. Structure Designed as(check one): .X Enclosed _Partially Enclosed _Open 3. Risk Category: I X._tl 111 IV Exposure Category:___B__ X_ C _O 4. Design Wind Velocity 165 mph 128 ASD_WA_LRFD Fret Zone Width: 5__ft 5. Mean Roof Height_ 31'-9"' ft Roof Pitch: 6 :12 Parapet: NIA ft 6. Components& Cladding Design Pressures Used: +35.8 +35.5 +33.9 Zone 4: -38.8 Zone 5: - -47.9 _ Garage: _44.2___ Ea. Roofs Maximum +/-pressures! L-_Est - last Or define individual zones on the plans 7. Design Loads: Floor:_ gQ..........PSF Roof-Dead:­_5__PSF Roof-Live;,_2D_Balcony+/ NIA PSF Dock: NIA PSF Deck:. NIA PSF Stairs: PSF Fence;_ NIA PSF Railings:_ NiA PSF S. Were Shear Walls Considered For Structure?_X_Yes Not Applicable Please Explain: 9. Is a Continuous Load Path Provided?. _ _ X_ Yes_ _ ______Not Applicable Explain Why Not: 10, Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the current Florida Building Code as adopted. Signature, Date, and Seal Print Name Cent # & Co. Can ofAuthorization SUMMIT LUQbL&FFQF iCS INC ____ Revised 3/25/2021 Company Name & Address r RECEIVL� "v't, Lllei4.` DRArte GSFRVtC: S Lour»y PHONE: t772)237-7942 W W W.TREASURECOASMRAPIINO.COM GENERAL NOTES N o ,n L THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL VERII Y ALL P �+ DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, EC. {y M WILL B ADDRESSED BY Ci Li 2. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS ENGINEER AS CONSTRUCTION PROGRESSES. Q THE 3. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDEN OVER SCALED DIMENSIONS. a Q A 4. ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING DE (FBC) 2020, FBC 2020 RESIDENTIAL, FBC 2020 PLUMBING CODE, FBC 2020 CHANICALCODE, FBC 2020 ENERGY CONSERVATION, AND THE NEC (NFPA 70E) 1 EDITION. 5. RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN MIRY HEAVY TERMITE INFESTATION AREA PER FRC 301. I'I 6. ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY w II E F.B.0 2020 Z FOR EXISTING BUILDINGS. O PLUMBING NOTES'I z o G 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE FB-': 2020-PLUMBING 2. DWV PIPING SHALL BE SCHEDULE 40 PVC. . IF�•I 3. WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: CPVC, OR REX. IW PE L COPPER, 4. SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERCROli ID WITHIN BLDG. R"I/ 5. HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF F 3 SHALL BE APPLIED TO PIPING LARGER THAN %" NOMINAL DIAMETER, PIPIN FROM WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE C DI TONED SPACE, Q PIPING FROM THE WATER HEATER TO THE DISTRIBUTION MANIFO PIPING LOCATED A UNDER THE FLOOR SLAB, BURIED PIPING, SUPPLY AND RETUN ING IN RECIRCULATION SYSTEMS, PIPING WITH RUN LENGTHS GREATER AN 20 FEET. 6. WATER HEATERS INSTALLED SHALL BE IN ACCORDANCE WITH 2O20 ENERGY Z CONSERVATION. 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THEN (NFPA 70) 2017 EDITION. 2. A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED IGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS OR A MINIMUM OF 75% OF Tfll PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFI CY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH-EFFIC Y LAMPS). 3. .RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BE TWEEN CONDITIONED AND UNCONDITIONED SPACES. 4. SMOKE DETECTORS TO BE 110V Wf BATTERY BACK UP - ARC 7H LILT CIRCUIT. 5. SMOKE DETECTORS TO BE LOCATED AS SHOWN. 6. SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMO I DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE. 7. PROVIDE BRAWFI CIRCUIT ARC -FAULT PROTECTION FOR ALL Cl 13JITS SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRA ES, DENS, BEDRCfk4s, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWA 3. OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS. S. PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FO ALL 125-VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SERVING: BATHROOM GARAGES, KITCHF'dS, ACCESSORY BUILDINGS, OUTDOORS, OR WITHIN 72" EDGE OF ANY SINK 9. CARBON MONOXIDE DETECTORS TO BE INSTALLED WITHIN 10" OF NILL BEDROOMS. 10. EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. 11. PRCYIDE ":,APFR RESISTANT RECEPTACLES PER NEC REQUIREM TS. ��. . III Ii 1. GARAGE FLOOR SURFACES SHALL BI OF APPROVED NONCOME11BLE MATERIAL. 2. THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES 01 THER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. IN THE EVENT STEEL HAS BEEN INADVERTENTLY OMITTED FROM D OUR LOCATIONS, DRILL 6" INTO CONCRETE (NO CLOSER THAN 3%` FROM EDGES A 5" FROM ENDS OF CAP WALLS). REMOVE DUST PER IINSTRUCTIONS AND USE 0 PART EPDXY TO ANCHOR #5 REBAR IN PLACE. USE EITHER HILT C-100 OR SIMP N EPDXY -TIE. IT IS THE INTENT OF THESE DRAWINGS TO SHOW GENERAL RECUT ENTS RELATED TO THE CONSTRUCTION OF THIS PROJECT. IT IS NOT THE INTENT TO SHC EACH AND EVERY PIECE OF MATERIAL OR EVERY METHOD REQUIRED FOR SOUND CONSTRU ON. THE CONTRACTOR SHALL CHLCK AND VERIFY ALL DIMENSIONS BEFORE STARTING PR I 11GN CT. JOAN JAFFE LLC IS NOT RESPONSIBLE FOR ANY ERRORS OR MISTAKES ONCE CONSTR ION HAS BEGAN. IN CASE OF QUESTIONS, PLEASE CONSULT JOAN JAFFE LLC AND SUMMIT & FORENSICS, INC. THESE DRAWINGS ARE THE PROPERTY OF JOAN JAFFE, LLC., FOR THE f:^NSTRUCTION OF ANY PROJECT OTHER THAN THE BLOCK Of EACH SHEET. BUILDING SHALL BE PROVIDED WITH APPROVED ADDRESS IDENTIF IDENTIFICATION SHALL BE LEGIBLE AND PLACED IN A POSITION T THE STREET OR ROAD FRONTING THE PROPERTY. ADDRESS IDEN- SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL NOT BE CHARACTER SHALL BE NOT LESS THAN 4 INCHES (102 MM) IN - WIDTH OF NOT LESS THAN 0.5 INCH (12.7 MI WHERE REQUIREI OFFICIAL, ADDRESS IDENTIFICATION SHALL BE PROVIDED IN ADDII LOCATIONS TO FACILITATE EMERGENCY RESPONSE. WHERE ACCES PRIVATE ROAD AND THE BUILDING ADDRESS CANNOT BE VIEWED WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE STRUCTURE. ADDRESS IDENTIFICATION SHALL BE MAINTAINED. NOT BE USED 1J IN THE TITLE Ic Z DN. THE ADDRESS IS VISIBLE FROM ,TION CHARACTERS .L BE ARABIC LED OUT. EACH T WITH A STROKE THE FIRE CODE L APPROVED BY MEANS OF A A THE PUBLIC ) TO IDENTIFY THE IS I r,0 G\rl" !,V 0 W U W M O O I W�wUB Co a� N "" ] 0� �UFw x U a U Q v ® Z cn In J °7 m V n LLI Ui � 2 J CD U1 0 j ii Nw�100 I- N [�0. �. • �f 0 in Z w In Ln N 0 n W n 0 ® SCALE: N.T.S. JOB No: 521-0219 A i WLZ¢ I #5 VERT DOWEL REINF. 0 ALL WALL JAMB, ALL UNDER CORNERS, UNDER ALL GIRDERS AND AT 48" O.C. MAX. (TYP.) FHB 4" THICK MIN. POURED CONCRETE UTILITY SLAB REINFORCED WITH FIBERMESH (VERIFY SIZE AND LOCATION WITH HOMEOWNER) Hw — — — —F3 — — — -- —I - F1 P9 Ll - O- P1 12" COLUMN BLOCK w/(4) #5 HB ■ Ft 0-0® I Fa CI I I ■ O I N (TYP.) DOWELS TYP. Pt TOP OF SLAB Pt n co TYPICAL 8°' CONCRETE - — > 6 I F4 (SEE SHEET-S1/DETAIL 1) ■ — JA FY `1 I Pt CD r ® 13'-10" 21'-2" 6°' THICK SLAB (2500 psi min.) L J J 8"X12" CONCRETE REINFORCED w/ WELDED WERE AND FIBERMESH ON 6 MIL a COLUMN w/(4)#5 VAPOR BARRIER OVER I & & 3 TIES 8" O.C. CLEAN 95% COMPACTED TERMITE TREATED ®� PREPARED SUBGRADE 'XV z < I $ #5 040" O.C. MAX. & < 1� r- _ I RECESS SLAB 4 AS SHOWN U.N.O. (TYP.) I Ng W I -t 2 =2 1 8 MIN. / BELOW FINISH FLOOR ■ a N "� u ev Pt I SLOPE ALL FOUNDATION TYPICAL: STEEL BARS SHALL BE I o n 8"X12" CONCRETE CONTINUOUS AROUND CORNERS USING CORNER P3 h xU 1 COLUMN w/(4)#5 BARS W/ MIN. LAP SPLICE OF 30" I n"r' & #3 TIES 8" O.C. ■ c.1 I 0 2\_ F 71 ❑■ #3 DOWELS x 1'-0" LNG. SPA. ■ 1' 4" O.C. EPDXIED 6" INTO -.........- CONCRETE COLUMN I ■ • -J BOTH SIDES (TYP.) I F6 P' 4,-27 „ 6,-0„ I ■ z w :xCL ■ I Fs s ® ONCRETE COLUMN co `� I w/(6) #5 & #3 TIES P3, ■ F5 I ■ 8"X12" CONCRETE Pfi P1 P1 FP5t 36" x 36" x 24" DEEP (2500 PSI) COLUMN w/(4)#5 & #3 TIES 8" O.C. �j I ■ / f \ 1 CONCRETE PAD FOOTING w/(3)-#5 BARS EACH WAY 00 ■■ ■■ o ■ ® Pt TOP OF SLAB Pt _ P1 L I v I I Fs ■ _ _ _ _ HB P7 ■ �" ■■ ■■ ■ lk . -- I I F1 ea 4 LJ Pi N CONCRETE FQUNDATION NOTES 1. SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 2. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" SUBGRADE PREPARATION NOTES 1. THE AREA WITHIN THE LIMITS OF THE FOUNDATION SHALL HAVE ALL VEGETATION, TOP SOIL AND FOREIGN MATERIAL REMOVED. 2. CLEAN FILL SAND AND OR GRAVEL FILL, FREE OF VEGETATION AND FOREIGN MATERIAL, MUST BE PLACED TO DESIGN SUBGRADE LEVEL AND COMPACTED TO ASSURE UNIFORM SUPPORT OF THE FLOOR SLAB. 3. SUBGRADE COMPACTION SHALL BE ACHIEVED BY MEANS AND METHODS DETERMINED BY THE RESPONSIBLE CONTRACTOR. SOIL DENSITY TESTING BY INDEPENDENT SOILS TESTING FIRM SHALL BE REQUIRED TO INSURE PRESCRIBED SOIL DENSITIES ARE ACHIEVED. 4. AFTER FOOTING EXCAVATION, AND FORMING, CONTRACTOR SHALL RECOMPACT SUBGRADE SOILS USING SUITABLE VIBRATORY MECHANICAL COMPACTOR. THE UPPER 16 INCHES OF SOILS UNDERLAYING THE WALL FOOTINGS. SHOULD HAVE A MINIMUM DENSITY OF 95% OF THE MAXIMUM DRY UNIT DENSITY AS DETERMINED BY MODIFIED PROCTOR METHOD FOR THE EXISTING SOILS. IN -PLACE SOIL DENSITY TESTS SHOULD BE PERFORMED IN ACCORDANCE WITH ASTM D-2922, AT A FREQUENCY DETERMINED BY THE SOIL TECHNICIAN TO VERIFY UNIFORMITY OF THE UNDERLYING SOIL DENSITY, PRIOR TO PLACING CONCRETE. 5. SUBBASE COMPACTION FOR THE FLOOR SLAB FILL MATERIAL SHALL BE UNIFORMLY COMPACTED TO A MINIMUM DENSITY EQUAL TO 95% OF THE MAXIMUM DRY UNIT DENSITY OF THE FILL AS DETERMINED BY MODIFIED PROCTOR METHOD IN ACCORDANCE WITH ASTM D-1557. 6. CONCRETE SLABS ON GRADE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER WITH A MINIMUM THICKNESS OF 6 MILLS, INSTALLED WITH LAPPED JOINTS NOT LESS THAN 6 INCHES AND CONTINUOUSLY TAPPED WITH HIGH DENSITY POLYETHYLENE ADHESIVE TAPE. F6 � Pi Rv' 4'- I 7 DOWEL 08" 01 & AS SHOWN (TYP. AT FOYER) 1. ALL DOWELS AND VERTICAL BARS ARE #5 EXCEPT AT EXTERIOR FOYER WALL BARS ARE #7 2. #5 DOWELS 44°° L#5 #7 DOWELS 56°° L#7 (30" LAP) (42" LAP) 10'° #5 14" #7 3. ATTACH DOWELS TO FOOTING STEEL 5. FILL CELLS AT VERTICAL DOWELS GROUT6. • BE 3000AND REBAR TO BE GRADE 60 5 8" x 16" CONCRETE COLUMN w/(6) #5 & #3 TIES ® 8" O.C. #3 DOWELS x 1'-O" LNG. SPA. ® 1'-4" IE O.C. EPDXIED 6" INTO CONCRETE COLUMN WINDOW AND DOOR NOTE: ** IT IS THE RESPONSIBILITY OF THE WINDOW AND DOOR SUPPLIER TO COORDINATE ALL REQUIRED OPENINGS WITH THE CONTRACTOR PRIOR TO ANY WORK. THE WINDOW SUPPLIER IS RESPONSIBLE FOR CODE COMPLIANCE OF HIS PRODUCTS. 8" MASONRY WALL, SEE PLAN #5 REBAR 048" O.C. (MAX.) ADD (1) CONTINUOUS #5 & AS SHOWN ON PLANS TOP BAR AND #4 X 5'-0' TRANSFER BARS w/ 10' HOOK % MIN. X 8" WIDE BLOCK SPA. 0 1'-6" O.C. WHERE RECESS DESIGNATED ON FOUNDATION 30" MIN. W #5 PLAN & 42" MIN. @ #7 (^ 6" (NICK (MIN.) POURED w z GONG. (2500 PSI MIN.) 6" THICK (MIN.) POURED GONG. (2500 PSI MIN.) FINISHED FLOOR ADD (1) CONTINUOUS #5 TOP BAR AND #4 X FINAL GRADE--""'5'-C" TRANSFER BARS TTN W/ 10' HOOK SPA. �i����������•l ��li �� i��i�y��\���\�y�. y����i�� 1 DESIGNATEDEON �'�� �ii� + •e 12" MIN. EMBEDMENT ��. .��� FOUNDATION PLAN 6x6-WL4xW1.4 WWM BELOW EXISTING GRADE &FIBERMESH 3" MIN. (3) #5 CONTINUOUS REBAR -- 2'-0" g" CLEAR COVER THICKENED EDGE MIN. (TYP.). FOOTING WITH (3) #5 6X6-W1.4xW1.4 WWM BARS CONTINUOUS DOUBLE WITHIN 3 FT. FROM FOOTING (TYP) & FIBERMESH F1 EXTERIOR WALL FOOTING F TIG AT OHG SCALE: 318" = V-0" " MASONRY WALL, SEE PLAN #5 REBAR ' O.C. (MAX.) & AS SHOWN ON PLANS ADD (1) CONTINUOUS #5 TOP BAR AND #4 % 5'-0- TRANSFER BARS w/ 10" HOOK _ SPA. 0 V-6" O.C. WHERE DESIGNATED ON FOUNDATION °a ? PLAN 7- CURB 6" THICK (MIN.) POURED kz` DIA.00" A.B. 024" O.C.- > GONG. (2500 PSI MIN.) MAX. W/7" MIN. EMBED, FINAL GRADE _ , 2" (MIN.) P.T. SOLE PLATE w ,. r . �� \ ^^ a e Fj� F• > 12 MIN. EMBEDMENT (TYP.). ,� B ® OW EXISTING GRADE �� �� ��..• � 3" MIN. •��� � i.i CLEAR COVER (3) #S CONTINUOUS REBAR �2 0" 60' 6" R (-fYP) ��� MIN. 0 12" 6X6-W1.4xw1.4 WWM DOUBLE WITHIN 3 FT. FROM FOOTING (TYP) & FIBERMESH tJ E3 SECTION F..INTERIORT P BEARING SCALE: 318F_)" = i°-0°' NON -BEARING " MASONRY WALL, SEE PLAN 5 REBAR 048' O.C. (MAX.) & AS SHOWN ON PLANS %-MIN. X 8" WADE BLOCK RECESS 6" THICK (MIN.) POURED 3 )k" POURED CONC. CONC. (2500 PSI MIN.) X" TOOLED EDGC, TYP, PORCH SLAB OR F.F. PAVERS PER PLAN w R ADD (1) CONTINUOUS #5 a 3 TOP BAR AND #4 X > 12" MIN. EMBEDMENT ' < a 5'-0" TRANSFER BARS ; BELOW EXISTING GRADE w/ 10" HOOK SPA. 0 °o 3" MIN. V-6" O.C. WHERE mF41/'�• 3 CONTINUOUS REBAR CLEAR COVER DESIGNATED ON () N5 2'-0" 6' FOUNDATION PLAN MIN. ✓� 6X6-W1.4xW1.4 WWM DOUBLE WITHIN 3 FT. 1'-0" FROM FOOTING (TYP) & FIBERMESH VERIFY W/ SCALE: 318" = 1'-0" 2x6 FRAMED NON -BEARING WALL SEE TYP. DETAIL FOR CONNECTION TO FOUNDATION ° THICK (MIN.) POURED CONIC. (2500 PSI MIN.) 6X6-W1.4xW1.4 WWM & FIBERMESH #5 BARS CONTINUOUS 6" THICK (MIN.) POURED GONG. (2500 PSI MIN.) 6X6-W1.4xW1.4 WWM (OR FIBERMESH) (1) #5 BARS CONTINUOUS r T)F.AF mo SP- vlc9 5 wn.a cu MOM: (772) 287-9942 W w W.TREA.4UAECOASTDRAFnNO.COM _ry T 0 ti � W � Q � Q A u A 0 z 0 A E+ A z W WU 7� O " ® A O �A o " wOww p�I oo�ao z NooaA � �wW F Z a ® U U O A h+i lJ Z _ > Vm LU V1 U LL IN. (n Z � en a �WUEn Q F J N NI i N (i � Z cd n n Z w En ' m VI N LIJ n a �Q Io-z0=-z� SCALE: 1/41/4 = F 0-0" JOB No: 521-0219 P I �` j1 �_ f 3" VTR 4" (MIN.) TO ON - SEWER 4" (MIN.) BUILDING SEWER TO ON -SITE SANITARY SEWER LIFT STATION SANITARY PLUMBING ISOMETRIC SCALE: N.T.S. 3" VTR LINTEL SCHEDUI._E.: SAFE GRAVITY LOAD APPLIED GRAVITY LOAD SAFE UPLIFT LOAD APPLIED UPLIFT LOAD 6113 1400 3060 1600 5206 1400 2362 - 2459 800 1364 600 2661 500 1624 700 1002 200 560 200 6113 200 3524 200 6113 1400 3060 1600 1075 1 200 607 200 LOCATIONS, WORST CASE LOADING IS SHOWN :AST CONCRETE LINTEL AS NOTED ON PLANS NOTE: 1. COMPOSITE BEAM DEPTHS SHOWN ARE MINIMUM REQUIRED, AND MAY BE INCREASED IN FIELD WITHOUT ENGINEER'S APPROVAL. 2. CALCULATED APPLIED GRAVITY LOAD AND APPLIED UPLIFT SHOWN ARE WORST CASE, ROOF TRUSS GIRDER LOADING HAVE BEEN CONSIDERED. 3. MASONRY CONTRACTOR TO VERIFY EACH MASONRY OPENING WIDTH AND HEIGHT PRIOR TO CONSTRUCTION. 4. LENGTHS OF LINTEL SHOWN ARE ACTUAL LINTEL SIZES (BEARING OF 4" EACH END). SAW CUT BOTTOMS OF LINTEL MANUFACTURERS NOTCHES WHEN NEEDED TO EXTEND REBAR THROUGH LINTEL @ EACH SIDE OF OPENING. 5. ALL LINTELS SHALL BE SET TO PROVIDE A MINIMUM 4" BEARING ON MASONRY AT EACH END, UNLESS DETAILED ON THESE PLANS. 6. REINFORCED PRECAST "U" LINTELS SHALL BE MANUFACTURED WITH 5 1/2" LONG NOTCHES AT EACH END TO ACCOMMODATE PLACEMENT OF VERTICAL REINFORCING AND GROUT FILLING CELLS BELOW. 7. SEE TYPICAL LINTEL SECTION FOR CAST-CRETE DESIGNATIONS AND PLACEMENT OF REINFORCING STEEL. STEEL PLACED IN BOTTOM OF PRECAST LINTEL SHALL BE SET ON WIRE CHAIR TO PROVIDE 3/4" CLEARANCE OFF BOTTOM. F = FILLED WITH GROUT / U = UNFILLED _ r QUANTITY OF #5 REBAR AT _ a• ' BOTTOM OF LINTEL CAVITY � F1 6-1 B/1T Io 44 'f) Z LQUANTTTY OF #5 m REBAR AT TOP • NOMINAL HEIGHT NOMINAL WIDTH 7-5/8" ACT 8" NOMINAL WIDTH TYPE DESIGNATION 8F1 6-1 B/1T ***FILL CELL ON EACH SIDE OF EVERY OPENING AND UNDER ALL GIRDERS — #5 REBAR CONTINUOUS ALONG TOP OF WALL 1-1/2" CLEAR — 8" BOND BEAM BLOCK (RINKER/CEMIX #TB1 OR EQ.) — GROUT SOLID (3000 psi) —#5 REBAR AT BOTTOM 3/4" CLEAR OFF 8" PRECAST LENTIL 154 CFM 10x10x8 2"0 10x10x8 148 CFM 21 I M xfl, 16 4x4 'FM 44 — — — — �\ 3 CFM u 108 CFM 149 CFM \ 8x x4 10x10x8 MECHANICAL PLAN Bx4,4 S A R (1 M) 9 NEW SUPPLY AIR RESGISTER (SIZE & CFM) g"r / NEW SUPPLY AIR DUCT (R-8 FLEX) ■ SUPPLY AIR DISTRIBUTION BOX (RIGID FIBER DUCT BOARD) CEILING MOUNTED RETURN AIR GRILL (w/o FILTER) WITH FLEX TRANSFER DUCT T.OEVERED DOOR CAlIft.T ATTON REQIREDREI'LRPCEM: 02Ck-fi REOIIIRED NET FREE OPENING; 168 SO. INCHES DOOR SIZE: 38"WIDF X 96" IIIOD LOUVER SIZE: 26" WIDE X 04" RICH (2184 SO. INCH ES) LOUVER MATERT.AL: WOOD NE'1 k'ktiE OPEN LV G AT LOL \'ER: ild4 SQ. IN. X U.25 — SX. SQ. IN. (1'ER k'RC M130+,q,1.2) 34G SQ- IN.OPENIN[:> 168 SQ. [N_OPENIN(; THEREFORE, LOUVERED DOOR O.K. N.T.S. ;FM x7 P DR.AITING SP.RVICES .w rA.me.•• PFIONE: (772) 237-7N2 WW W.1RHA91)AECOASTDRAPIING.COM ti N ti .i h fC A A U z rn I•i A F A 0 z IL W UA x w W U U 0� W M �W o O o Iwo zz w�W� �t 00 �u as �j a �� U H� U zoo �x �U �v —zo � J � V m M w j tL n do cIn In � I-WUIn ® F J N /1LL d7HN M sC"pnzr, a Z W U 0 do N Lu n o 0*4 I r )0-ZZ) -� SCALE: 70B No: 521-0219 P2 DRYER VENT (FIELD LOCATE WITH OWNER) FIELD LOCATE HW WITH HOMEONWER FHB ■ n F -I I SINK Ld HW ■ I� ° z 0' 3"DIA.x48" STEEL GUARD HB ® LAUNDRY PWDR, e io POST WIX%10" SQUARE ■ I BASE w/(4) Y2 x2 X" WEDGE o TILE TILE 00 BOLTS 6`-0" ■ 2, ymify ■ L C R-11 INSULATION"- 30805C 20-MIN. FIRE RATED SELF -CLOSING - ■ cl E / s" L-4 I BEOAMRE #5 040" O.C. MAX. & I A80VE AS SHOWN U.N.O. (TYP.) ,.� w I U-) ti ; ® z� O en O 3: N o I 0 w e ■ N I N z~ i EXTENDED GARAGE I X =I � i I o� N, 33'-8 4 10' O"CLG/CONC. I ai oD I 0 M 2 ##3 DOWELS x 1'-0" ■ \ �� LI - B A9 LNG. SPA. 0 1'-4" I 0 I O.C. EPDXIED 6" INTO N CONCRETE COLUMN BOTH SIDES (TYP.) N -----�- • CONCRETE COLUMN w/(5) #5 & #3 TIES •8" O.C. 4'-27 " W-0" 8"X22" CONCRETE BEAM ■ ABOVE w/(6)-#7 TOP & Y BOTTOM & #3 0 9" O.C. I m a r I i \ 8" x 24" CONCRETE / :2- ■ ■ DO Jlk BEAM ABOVE wA6) #7 / 0 & #3 TIES • 10" O.C.lb -- �p F--\_ • 8"X12" CONCRETE I ■ _FLOOR ABOVE LINE_ 1_ _ _ _ _ COLUMN w/(4)#5 00 3080SC 20-MIN. e I - - - - - - \\ - - & #3 TIES 8" O.G. ® FOYER FIRE RATED 0 // • ■ SELF -CLOSING OPEN TO ABOVE/TILE \ / ■ I HB v ■ 6, 12'X8' OHGD m � e N 04 42°X8' SC- CONTINUOUS 2X4 P.T. BLOCKING (2"x4" MIN.) FASTENED w/ Y4'O TAPCONS x 3)12" LONG 0 16" O.C. 5/8" PLYWOOD PRE -FABRICATED ENGINEERED WOOD TRUSSES (6) #7 BARS (1)2x8 P.T. CONTINUOUS WOOD — LEDGER (SYP #2 OR DOUGLAS FIR #1 OR BETTER) ANCHORED TO WALL w/ %"0 HILTI KWIK BOLT TYPE Ill WITH 6Y2" EMBED (MIN.) 012" O.C. w/PLATE WASHER LU�IUPI UUUn V-011 4.-27 " #7 4i9 O.C.— (TYP. OF FOYER) 1ST STORY FLOOR FLAN _ SCALE: 1/4" V-1)" (1)2x8 P.T. CONTINUOUS WOOD LEDGER (SYP #2 OR DOUGLAS FIR #1 OR BETTER) ANCHORED TO WALL w/ Y'4'0 HILTI KWIK BOLT TYPE III WITH 6Y2- EMBED (MIN.) 012" O.C. w/PLATE WASHER 2x4x24" DEEP PRE -FABRICATED ENGINEERED FLOOR TRUSSES 0 24" O.C. (SEE 2ND FLOOR FRAMING PLAN FOR LAYOUT) 2x4 BLOCKING 0 24" O.C. ACROSS BOTTOM CHORD FIRST 2 SETS OF FLOOR TRUSSES w/ (2)16d NAIL AT EACH TRUSS 5/8" GYPSUM DRYWALL BOARD ❑• #3 DOWELS x 1'-0" LNG. SPA. 0 1'-4" O.C. EPDXIED 6' I CONCRETE COLU BOTH SIDES (T .) L-6 n �+ E❑ I WI �I J o Y L-5 J w GI L " c' ¢ 0., a �I wl O a DO M Z I �L I o� W 0 RAILING INSTALLATION (4) LJ-4000 SQUARE AND ATTACHMENT NEWEL WOOD POST REQUIREMENTS BY OTHERS CABLE SPACER BAR TOWER WINDOWS LOCATION -- SCALE: IN' = T-V LJ-6400 TOP HAND RAIL 0 36" MIN. A.F.F. 952" T316 STAINLESS STEEL CABLE (TYP.) PAN RY 21°-10" #5 040" O.C. MAX. &— AS SHOWN U.N.O. (TYP.) e- ■ 17'- KITC 10'-0"CEILING LINE 36X72 L-C S. EI 1 ■ L-a 4' 36X72 ]IT) S. EGRE' w� ■ — t L-a 16'-2Y." f t t 441 S w4 S C r ml ;E: o 3 z J p " Q emU3 a7 Lx v I ■ t- K "' AHU ■ w C3 e 2' 7" W.I.C. µ A3 ani,I. L. SEE DETAIL I (TYP.) SHEET-A3 36"H MIN. A M / RAILING \ HSS4x" \ A \ . NO OPEN TO BELOW L-6 K BATH 10'-0"CLG/TILE Mm Pro IL --_- WALL BELLOW LINE SECOND FLOOR LAYOUT SCALE: 1/4" 1'-0" ■ ■ ■ 24'-O"H x B" CMU MASONRY WALL 30'-0"H x 8" CMU MASONRY WALL 10'-0"H x 8" CMU MASONRY WALL 2x6 STUD NON -BEARING PART. WALL IiijiijiiIiijiijiiIINTERIOR INTERIOR 2x4 STUD NON -BEARING PARTITION WALL L-1 PRE -CAST CONCRETE LINTEL DESIGNATION (SEE SHEET-P2) VTR SOIL PIPE VENT THROUGH ROOF 54%72" SH WINDOW MARK (ALL IMPACT) (54"W x 72"H OPENING) NOMINAL (SEE MANUFACTURER'S SPECS FOR DETAILS) 2680 INTERIOR DOOR MARK (2°-6"W x 8'-O"H OPENING) 6'x8' GLAZED DOOR EXTERIOR DOOR MARK (ALL IMPACT) (6 0 W x 8'-0' H OPENING) NOMINAL (SEE MANUFACTURERS SPECS FOR DETAILS) A3 ` r► _ 1 � 'ytP I y� t r� < I Rr WINDOW AND DOOR NOTE- ** IT IS THE RESPONSIBILITY OF THE WINDC AND DOOR SUPPLER TO COORDINATE ALL REOt ED OPENINGS WITH THE CONTRACTOR PRIOR TC ANY WORK. THE WINDOW SUPPLER IS RESPONSH FOR CODE COMPLIANCE OF HIS PRODUCTS. S SHALL HAVE FLOORS AND LIS TO ABSORBENT MATERIALS ASP FBC EGLASS ONG A TUB OR SHOWER, WI " SHALL BE TEMPERED AS P DN AFTING SERVICES cx c PHONE: (772) 237-7WI W W W.TRHASURECOMMRAFTINGcom N rl 0 Fi y 01 ' VI �H Q qqq fC Q ICA z a A A z� 0 � z U H 0 N w q � � Vi I -I a ❑ m Q q N 0 zd W u Q O 'r1 H I W w0W�m po a� 0 Nu oa w U a U 0 v Z O S} 7 � °0 m V w VT U CLn Lu O � F- J N i/R 0mZrN a z V„ m VT N o LJ n * SCALE: AS NOTED JOB No: 521-0219 Al W OWNER SELECTED STONE VENEER FRONT ELEVATION ONLY DECORATIVE PRE —CAST - BRACKETS OVER RAISED STUCCO BANDING (TYP.) METAL ROOF/STANDING SEAM OVER ICE AND WATER SHIELD PEEL AND STICK 12 (COLOR & PROFILE TO BE SELECTED 12 6 BY OWNER, TYP.) Ilia IIII p1I sill IN . 6U ..N „o ., T.O. WALL T.O. WALL - — 12 6 28°-0" 28'—O" T.O. WINDOW T.O. WINDOW i 1E T. URE IF 3E 1E — TYP. T.O. WINDOW 19'-4" T.O. WINDOW +" SMOOTH SAND STUCCO 1F lE tE 1E FINISH OVER MASONRY 1E FAUX PRECAST OR EXTERIOR (TYPICAL) DECORATIVE EFIS IMPACT RESISTANT CONTOURED CEMENT DOORS & WINDOWS STUCCO (TYPICAL (TYP.) WHERE INDICATED) L2_ 12 T.O. FLOOR 0 T Q. FLOOR ' / F��lll r I�I FRONT VIEW ELEVATION SCALE: 1/4" = 1'-0" ELEVATION SCALE. 1/4" = 1'-0" T.O. F.F.E. Y Yf.O. F.F.E. 12 til6 12 6F-:;; �I �Y'+" SMOOTH SAND STUCCO FINISH OVER MASONRY EXTERIOR (TYPICAL) SMOOTH SAND STUCCO FINISH OVER MASONRY EXTERIOR (TYPICAL) RIGHT VIEW ELEVATION SCALE: 1/4" = 1'-O" 12 ;:Z�j6 0�00� LEF7 VIEW ELEVATION SCALE: 1/4" = 1'-0" 12 61 12 ;Z7 6 r 0 N ROOF T.O. E 28' T.O. WIN[ 1 T.O. I T.O. Lad ORAPTING SRRVICPS PHONE: (772) 2974942 W W W.TRHASIHtECGASIDRAPCING.COM 0 0 ' a a A z d 0 z� oW �+ A W D (i V/ 1 W M h O A O i �S woWdA h� 00 �N1] 0A 0 ly U � 0w z �-I E a U U E-+ 0 r t.J �Vm I V ] �s V) U u P, aZ D m fn W O ® LL1 J c (~lsWU In 0 F F J N � aC7F N Uri_X Q U) Z f� W Q f Z W 9) V v) Vl N p ® Q n a SCALE: 1/4" = V-0" JOB No: 521-0219 A2 INTERIOR �:. SCALE: 1/4" m 1'-0" CALCULATE ATTIC VENTILATION REQUIRED VENT. - 1,484 F..1..2 (144 IN2/FT2)/150 = 1,425 IN SOFFIT VENT. = 170 FT/6'-O" O.C. = 29 VENTS 29 VENTS (6"X22"X0.5) = 1,914 IN UPPER VENT. _ (3) UPPER VENTS = 300 IN TOTAL VENT. = 2,214 IN2 WIND PRESSURES AS PER ASC: ;'-16 EXTERIOR OPENING DESIGN PRESSURE CHART 160 MPH EXP: C: AREA I E !MARK ZONE 4 ZONE 5 POSITIVE (PSF) NEGATIVE (PSF) POSITIVE (PSF) NEGATIVE (PSF) 1 10.0 1 +33.4 -36.3 +33.4 -44.8 2 15.0 +32.7 -35.1 +32.7 -43.0 3 20.0 +31.9 -34.7 +31.9 -41.7 4 25.0 +31.6 -33.8 +31.6 -40.6 5 30.0 +31.3 -33.6 +31.3 -40.1 6 35.0 +31.0 -33.4 +31.0 -39.4 7 40.0 +30.6 -33.3 +30.6 -38.7 8 45.0 +30.3 -32.9 +30.3 -38.1 9 50.0 +30.0 -32.8 +30.0 -37.7 10 100 +28.4 -31.2 +28.4 -34.7 STONE VENEER NOTE: (OPTIONAL FEATURE) STONE VENEER UNITS NOT EXCEEDING 10 INCHES (254 MM) IN THICKNESS SHALL BE ANCHORED DIRECTLY TO MASONRY, or CONCRETE BY THE FOLLOWING METHODS: 1. WITH CONCRETE OR MASONRY BACKING, ANCHOR TIES SHALL BE NOT LESS THAN 0.1055-INCH (2.68 MM) CORROSION -RESISTANT WIRE, OR APPROVED EQUAL, FORMED BEYOND THE BASE OF THE BACKING. THE LEGS OF THE LOOPS SHALL BE NOT LESS THAN 6 INCHES (152 MM) IN LENGTH BENT AT RIGHT ANGLES AND LAID IN THE MORTAR JOINT, AND SPACED SO THAT THE EYES OR LOOPS ARE 12 INCHES (305 MM) MAXIMUM ON CENTER (D.C.) IN BOTH DIRECTIONS. THERE SHALL BE PROVIDED NOT LESS THAN A 0.1055-INCH (2.68 MM) CORROSION -RESISTANT WIRE TIE, OR APPROVED EQUAL, THREADED THROUGH THE EXPOSED LOOPS FOR EVERY 2 SQUARE FEET (0.2 Mz) OF STONE VENEER. THIS TIE SHALL BE A LOOP HAVING LEGS NOT LESS THAN 15 INCHES (381 MM) IN LENGTH BENT SO THAT IT WILL LIE IN THE STONE VENEER MORTAR JOINT. THE LAST 2 INCHES (51 MM) OF EACH WIRE LEG SHALL HAVE A RIGHT-ANGLE BEND. ONE -INCH (25 MM) MINIMUM THICKNESS OF CEMENT GROUT SHALL BE PLACED BETWEEN THE BACKING AND THE STONE VENEER. IN 9 2"X6" COMPOSITE DECKING GROUT MASONRY - SOLID AT ANCHORS PRE -CAST - LINTEL (TYP.) 12" COLUMN BLOCK w/(4) #5 (TYP.) SIMPSON LUS26-' W/(8)-10d _ 0 2X6 P.T. JOIST I SPA. 0 1'-4" O.C. cv GALV. METAL TRUSS CONNECTORS (SEE TRUSS TO WALL CONNECTOR SCHEDULE) (2)-2"X6" P.T. LEDGER W/3/4" HILT] KWIK BOLT 3 W/NUT AND WASHER SPA. 0 2'-8' O.C. GROUT MASONRY SOLID AT ANCHORS (6) #7 BARS X" BOLT W/NUTS & WASHERS X" U-PLATE (2) %"HILTI KWIK BOLT TYPE - (3) W/6X- EMBED (MIN.) W/NUTS 1Y" � �I --0 0 0 3„ ANGLE POINT a� HSS4.x4xYg" Cf LEV. VIEW 1x" 11 PLATE 0 DRAFTING SRRVICPs MONE:(772) 2974942 W W W.TREASU OMMRAMNGMM N Q Q �i /L Pi Q � A A z 4 a 0 z 0A H Q d z C) Ao8 C) o L�L C� WO" C� �xAam 00 a� N E"o u� N� 0 U p� 0 C) p�11 H� 1® � 1.® Z O m M • W ' V1 U LL P W J N t r O s Q 1✓i 0 Ln N a h z W MV N V it ui Ln W h fl I 10 - zio SCALE: AS NOTED JOB No: 521-0219 A3 i METAL ROOFING OVER ICE AND WATER SHIELD PEEL AND STICK ON %" COX PLYWOOD SHEATHING ALL OVER PRE —FABRICATED ENGINEERED WOOD TRUSSES (SEE ROOF SHEATHING NAILING ZONE DIAGRAM AND NAILING SCHEDULE FOR NAILING REQUIREMENTS) GALV METAL TRUSS SEAT/HURRICANE— ANCHOR STRAP 0 EACH TRUSS EMBEDED INTO BOND BEAM (SEE TRUSS TO WALL CONNECTOR SCHEDULE) 2x6 (SYP. #2) BLOCKING 0 EVERY THIRD TRUSS (2-16d COMMON NAILS EACH END) TYPICAL TOP OF WALL BEARING HEIGHT ATTACH 1X2 P.T. TRIM WITH NON —CORROSIVE (1) 12GA. x 2" LONG RING —SHANK NAILS 0 24" O.C. (MAX.) 2X8 FASCIA ATTACHED TO EACH TRUSS TAIL w/ 2-16d NAILS (MIN.) 6"X22" SCREENED SOFFIT VENTS SPAC. 0 6'-0" O.C. MAX. N' MIN. STUCCO ON HIGH RIBBED SELF ::: FURRING GALV. METAL LATH, TYP. 2x4 P.T. CONT. NAILER FASTEN TO WALL w/Y4"0 x 3" TAPCON 016" O.C. AND END NAIL w/2-16d OR TOE NAIL w/3-10d (MIN.) 8" CMU BOND BEAM BLOCK GROUTED SOLID w/(1) #5 BAR CONT. AND EXTEND MIN. 6" INTO JAMB BLOCK EACH SIDE OF OPENING (TYPICAL 0 ALL WINDOWS) 8" CMU WALL — (1) #5 VERT. REINF. BAR GROUTED FILLED CELLS 0 40" O.C. MAX. AND AS INDICATED ON 2ND FLOOR PLAN #5 VERT. REINF. BAR TO EXTEND THROUGH 2ND FLOOR BOND BEAM BLOCK (TYPICAL) w CONTINUOUS 3 COURSES OF 8" CMU BOND BEAM y BLOCK GROUTED SOLID w/ (2) #5 BARS EACH = COURSE (OR 1—#7 BAR EACH COURSE) WITH (1) #5 CORNER BAR x 30" OVERLAP TYPICAL w x 3 (2) 2x8 P.T. CONTINUOUS WOOD LEDGER (S.Y.P. #2 OR DOUGLAS FIR #1 OR BETTER) WITH STAGGERED END JOINTS 36" LAP MIN. ANCHORED TO WALL WITH �Y4"0 HILTI KWIK BOLT TYPE III WITH 6N' (MIN.) EMBED. 0 8" O.C. WITH PLATE WASHERS & NUTS 8" U—SHAPE PC LINTEL (SEE LINTEL — SCHEDULE FOR SIZE AND REINFORCING) 8" CMU BOND BEAM BLOCK GROUTED SOLID w/(1) #5 BAR CONT. AND EXTEND 6" MIN. INTO JAMB BLOCK EACH SIDE OF OPENING (TYPICAL 0 ALL WINDOWS) 1/2" STUCCO (MIN.) ON ALL MASONRY EXTERIOR WALLS (TYP. U.N.O.) WITH TEXTURED FINISH AS INDICATED ON ELEVATION DRAWINGS 8'° CMU WALL — (1) #5 VERTICAL REINF. BAR GROUTED FILLED CELLS AT 40" O.C. MAX. (SEE FOUND. PLAN FOR BAR LOCATIONS) (1) #5 DOWEL BAR (12" HOOK TYP.) WITH 12" MIN. EMBEDMENT AND 30" LAP SPLICE LENGTH TYPICAL) SEE FOUNDATION PLAN FOR BAR SPACING FINISHED FLOOR ELEV. (FFE) • 12 SEE ELEV1 2X4 BLOCKING AT PLYWD PANEL EDGES (NAILED WITH 2-16d COMMON NAILS AT ENDS) SEE ROOF SHEATHING NAILING ZONE DIAGRAM AND NAILING SCHEDULE FOR BLOCKING LOCATION R-30 FIBERGLASS BATT INSULATION W/ KRAFT PAPER CONTINUOUS 2 COURSES OF 8" CMU BOND BEAM BLOCK GROUTED SOLID w/ (2) #5 BARS EACH COURSE w/ (1) #5 CORNER BAR x3O" OVERLAP TYPICAL (2—#5BARS=1—#7 BAR MAY BE USED) _---PROVIDE 8" U—SHAPE PC LINTEL 0 WINDOW & DOOR OPENINGS (SEE LINTEL SCHEDULE FOR SIZE AND REINFORCING) i --PRECAST SILL BY PRECAST MFR. GYPSUM WALLBOARD SHEATHING OVER 1-X2°° (NOMINAL) P.T. FURRING STRIPS ®24" O.C. (MAX.) AND R-4.1 FOIL INSULATION MIN. WITH REFLECTIVE VAPOR BARRIER / BASE BOARD 2"x P.T. BLOCKING BETWEEN FLOOR TRUSSES FASTEN TO MASONRY BOND BEAM BLOCK w/ Y4"O TAPCONS x 3N' LONG 06" O.C. AND TOE NAIL TO TRUSS w/ 2-16d COMMON (TYP) (2) SIMPSON HGAM10KTA W/(4) Y4" SOS x 1X" �& (4) Y4x234" TITEN 2 0 EACH TRUSS ADD (1) CONTINUOUS #5 TOP BAR �/ N/, A AND #4X5'-0 TRANSFER BARS w/ 10" HOOK SPA. 0 1'-6" O.C. WHERE DESIGNATED ON FOUNDATION PLAN SEE FOUNDATION PLAN FOR DIMENSIONS AND CONSTRUCTION DETAILS Y4' T&G B—D PLYWOOD SUBFLOOR SHEATHING APPLIED WITH STAGGERED HEAD JOINT AND FASTENED TO EACH FLOOR TRUSS w/ SUBFLOOR ADHESIVE (CONFORMING TO BOTH AFG-01 & ASTM D4398) AND #8x2Yz" DECK TOP OF 2ND FLOOR TRUSS SCREWS 0 6" D.C. ALONG EDGES AND 8" O.C. IN FIELD ELEV. = 12'-0" & 99' PLYWOOD LAYER ABOVE \ TYPICAL DOUBLE 8" CMU BOND BEAM BLOCK 2x4x24" DEEP PRE —FABRICATED ENGINEERED FLOOR TRUSSES 0 24" O.C. (SEE 2ND FLOOR FRAMING PLAN FOR LAYOUT) GYPSUM DRYWALL BOARD WINDOW BUCK (SEE WALL OPENING Sl BUCK DETAILS) si PRECAST SILL BY PRECAST MFR. Yz" GYPSUM WALLBOARD SHEATHING OVER 1"X2" (NOMINAL) P.T. FURRING STRIPS 0 24" O.C. (MAX.) AND R-4.1 FOIL INSULATION MIN. WITH REFLECTIVE VAPOR BARRIER 6" THICK CONCRETE FLOOR SLAB OVER PREPARED ~ "/--SUBGARDE (SEE CONSTRUCTION NOTES FOR REQUIREMENTS) PREPARED SUBGRADE (SEE CONSTRUCTION NOTES FOR REQUIREMENTS) SCALE: N.T.S. a'—n" AAIM ON 1E: SCALE: NTS 1. ALL 2ND STORY EXTERIOR WALL DOUBLE TOP PLATES SHALL BE CONTINUOUS. WHERE SPLICE IS REQUIRED, PROVIDE 6'-0" MIN. LAP AND FASTEN PLATES TOGETHER w/ (24) 16d NAILS (2 ROWS STAGGERED) OPTIONAL: SPLICE PLATES TOGETHER w/ SIMPSON STS236 w/ (20) 16d NAILS EACH END (1)2x8 P.T. CONTINUOUS WOOD LEDGER (SYP #2 OR DOUGLAS FIR #1 OR BETTER) ANCHORED TO WALL w/ -Y4'0 HILTI KWIK BOLT TYPE III WITH 6Yz" EMBED (MIN.) 012" O.C. w/PLATE WASHER 2x4 BLOCKING ® 24" O.C. ACROSS BOTTOM CHORD FIRST 2 SETS OF FLOOR TRUSSES w/ (2)16d NAIL AT EACH TRUSS 2x4x24" DEEP PRE —FABRICATED ENGINEERED FLOOR TRUSSES 0 24" O.C. 3g" GYPSUM DRYWALL BOARD CONTINUOUS 2X4 P.T. BLOCKING (2"x4" MIN.) FASTENED w/ Y4"O TAPCONS x 3J2" LONG ® 16" D.C. 2ND FLOOR FRAMING WITH TRUSS PABALLEL TO WALL PRE—ENGINEERED WOOD — TRUSSES SPACED 24" O.C. 2X4 BLOCKING AT PLYWD PANEL EDGES (NAILED WITH 2-16d COMMON NAILS AT ENDS) SEE ROOF SHEATHING NAILING ZONE DIAGRAM AND NAILING SCHEDULE FOR BLOCKING LOCATION BOND BEAM BLOCK (SEE LINTEL SCHED. FOR REINF) (1)#5 CORNER BAR WITH 30" TYP OVERLAPS GROUT FILLED 8" U—SHAPE PC LINTEL (SEE LINTEL — SCHEDULE FOR SIZE AND REINFORCING) PRECAST SILL BY PRECAST MFR.— 1X2 PT FURRING STRIPS 0 24" 0.( (TYP) R-41 FOIL INSULATION) AND 1/2" GYPSUM DRYWALL (TYPICAL) 6" THICK CONCRETE FLOOR SLAB OVER PREPARED SUBGARDE (SEE CONSTRUCTION NOTES FOR REQUIREMENTS) PREPARED SUBGRADE (SEE CONSTRUCTION NOTES FOR REQUIREMENTS) SCALE: N.T.S. 1. SEE PRODUCT APPROVAL SCHEDULE FOR METAL ROOFING REQUIREMENTS WHICH HAVE BEEN SELECTED TO COMPLY WITH 2O20 FBC—RESIDENTAIL, CHAPTER 9, SECTION R905.4 AND CLASSIFIED TO MEET Vult=160 MPH WIND RESISTANT RATING PER TABLE R905.4.4.1 2. INSTALLATION OF METAL ROOFING SHALL BE PER MANUFACTURER SPECIFICATION. 3. INSTALLATION OF METAL ACCESSORIES SHALL CONFORM TO 2020 FBC. METAL STUD WALL FRAMING NOTES, 1. WHEN METAL STUDS ARE SELECTED FOR INTERIOR NON —BEARING PARTIOTION WALL FRAMING SHALL CONSIST OF COLD —FORMED STEEL MATERIALS AS FOLLOWS: A) 3V' METAL STUD: 3 1/2" (25 GA.) COLD —FORMED STEEL STRUCTURAL C—SECTION PRODUCT DESIGNATION: 350S162-43: 33 KSI, G60 (OR BETTER) B) 3X" METAL TRACK: 3 1/2' (25 GA.) COLD —FORMED STEEL STRUCTURAL T—SECTION PRODUCT DESIGNATION 350T137-33; 33 KSI, G60 (OR BETTER) 2.BOTTOM TRACK STUDS SHALL BE FASTENED TO THE CONCRETE FLOOR SLAB WITH POWDER— ACTUATED 0.22 CALIBER (MIN.) SHOT PINS, 1" LONG x 0.300 HEAD DIA. x 0.145 SHANK DIA, NTH W DIA. STEEL WASHER. PLACE 1 SHOT PIN AT 16' O.C. STAGGERED FROM SIDE —TO —SIDE OF TRACK, OR EQUAL. 3. ALL METAL. STUDS SHALL BE FASTENED TO TOP AND BOTTOM TRACKS WITH (2) MIN. #8-18 x Y'4" S.M.S. (0.164" DIA. SHANK x 5/16" HEAD), OR BETTER. 4. METAL STUD TRACK SHALL BE FASTENED TO 2x4 WOOD STUD FRAMING WITH (2) #12-16 x 13'4" HEX WASHER HEAD WOOD SCREWS (OR BETTER). 12 ®� ISEE ELEV. METAL ROOFING OVER ICE AND STICK ON W' COX PL OVER PRE —FABRICATED EN (SEE ROOF SHEATHING NAI NAILING SCHEDULE FOR NO GALV METAL TRUSS SEAT/F STRAP ® EACH TRUSS EMB (SEE TRUSS TO WALL CONN ALUMINUM DRIP EDGE OVER TOP OF W ATTACH 1X2 P.T. TRIM WITH 12GA.x2" LONG RING —SHANK 2X8 FASCIA ATTACHED TO I TRUSS TAIL w/ 2-16d NAIL jig" MIN. STUCCO ON HIGH F FURRING GALV. METAL LATH 2x4 P.T. CONT. NAILER FAS w/Y4O x 3" TAPCON 016" NAIL w/2-16d OR TOE NAIL BOND BEAM BLOCK GROUTEI CONT. (AND EXTENDING MIN. EACH SIDE OF OPENING (TYI 1/2" STUCCO (MIN.) ON ALL WALLS (TYP. U.N.O.) WITH T INDICATED ON ELEVATION DF 8" CMU WALL — (1) #5 VEF GROUTED FILLED CELLS AT (SEE FOUND. PLAN FOR BAI (1) #5 DOWEL BAR (12" HO EMBEDMENT AND 30" LAP i SEE FOUNDATION PLAN FOR FIN ADD (1) CONTINUOUS #5 TC AND #4X5'-0" TRANSFER B w/ 10" HOOK SPA. ® V-6' DESIGNATED ON FOUNDATI01 SEE FOUNDATION PLAN FOR AND CONSTRUCTION DETAIL'. WATER SHIELD PEEL D SHEATHING ALL RED WOOD TRUSSES ZONE DIAGRAM AND REQUIREMENTS) :ANE ANCHOR INTO BOND BEAM d SCHEDULE) P.T. TRIM BEARING HEIGHT (BRG —CORROSIVE (1) _S ® 24" O.C. (MAX.) (MIN.) BED SELF TO WALL AND END 3-10d (MIN.) SOLID w/(1) #5 BAR 4" INTO JAMB BLOCK 'AL 0 ALL WINDOWS) dASONRY EXTERIOR ;TURED FINISH AS WINGS CAL REINF. BAR I" O.C. MAX. LOCATIONS) ( TYP.) WITH 12,1' MIN. -ICE LENGTH TYPICAL) IAR SPACING LI R ;ff•T41:aQI1A!/<IyY BAR IS ).C. WHERE PLAN f", WWII+ NO N.T.S. DRAF WG S1 VICFSs owrriwr"a • - PHONE: (772) 237-7942 wWw.MEMU ECOAS7DRAFMGN COai 0 0 ' ti p7 vNi Q M 0 A A U x a 0 z� I—i y A 5 F G z z A A I� VI 04�O 0 xxrwwM 1�0 00 44 t �J N] 0A U f �O[a� ID H V x I� V 0 U lJ ® Z 00 ° M w do U _j n WJ O w 0 cn= w °0 O F- J N l A}i U'- d 7 I— N v ecd0snzr4 a n Z w V)i " N V Ln 02 VI N 0 W N a yr� s SCALE: AS NOTED JOB No: 521-0219 I •'III r`:,,.c�, :�� �.•. SIMPSON STRONG —TIE ROOF TRUSS CLIP TYPE STC (1 CLIP 0 2x4S, 2 CLIPS ® 2x6S, 3 CLIPS @ 2XII (NOTE: EQUAL ANCHORS MAY BE SUBSTITUTED) SEEM 102=041130N ATTACH P.T. WOOD STUD TO CMU WALL WITH Y4" X 3" TAPCON AT 24" O.C. VERT. USE .145" DIA P.A.F. 016" O.C. TO CONCRETE WOOD BASE BOARD MOLDING RAT RUN 1x4 (MIN.) LAID FLAT 08'-0" Q.C. " GYPSUM WALLBOARD SHEATING 2x4 CONT. TOP PLATE OR LIGHT GAUGE METAL T—TRACK WOOD STUDS LIGHT GAUGE METAL C—STUD 2x4S 0 16" O.C. FOR ITO 14' 3 1/2" ® 24" O.C. FOR H=8' TO 10' 2x4S ® 24" O.C. FOR H=8' TO 10' 3 1/2" 0 16" O.C. FOR H=10' TO 14' 2x6S ® 24" O.C. FOR H=10' TO 14' WOOD STUD TO PLATE 2-16d NAILS ® 2x4S 3-16d NAILS 0 2x6S Y2" GYPSUM WALLBOARD SHEATING P.T. 2X SOLE PLATE OR LIGHT GAUGE METAL TRACK STUD (SEE NOTE #2) CONCRETE FLOOR SLAB PER PLAN 1. PLACE FIRE BLOCKING CONSISTING OF 2x4 SOLID BLOCKING (OR CODE APPROVED EQUAL) BETWEEN ALL STUDS IN ALL INTERIOR PARTITION WALLS EXCEEDING 10'-0" IN HEIGHT. BLOCKING TO BE PLACED IN A CONTINUOUS ROW AT 8'-0" (+/—) ABOVE FINISHED FLOOR SLAB. 2. INTERIOR PARTITION BEARING WALLS CONSTRUCTED WITH LIGHT GAUGE METAL STUD SHALL BE CONSTRUCTED OVER 2X P.T. WOOD PLATE FASTENED AS NOTED IN THIS DETAIL. 3. ATTACH P.T. 2x4 STUD TO ADJACENT CMU WALLS WITH Y4'x3" TAPCONS AT 24" O.C. VERT. STUCCO CEMENT FINISH CMU WATER RESISTANT COATING (SEE WATERPROOFING NOTES) F444 CORROSION RESISTANT FLASHINGPER WATERPROOFING NOTES Q r♦ Leammmangusm •1410 ImWolam" NOTE: WINDOW FRAME SHOULD BE COMPLETLY SEATED ON THE BUCK. IN NO INSTANCE SHALL THE FRAME OVERHANG THE BUCK M I.' I♦ . oMo. CONTINUOUS FOAM INTERIOR AIR AND WATER SEALANT PER / WATERPROOFING NOTES f MORTAR OR I.r GROUT SCALE: N.T.S. SCALE: 1/2" = 1 °-0"° FILLED CELL AT JAMB BLOCK (TYP) 1x3 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS SEE WATER PROOFING NOTES P.T. WOOD BUCK WITH SEALANT PER WATERPROOFING NOTES AND ANCHORED TO MASONRY PER BUCK ATTACHMENT NOTE. ANCHOR WINDOW FRAME TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. FASTENERS AS REQUIRED BY WINDOW MANUFACTURER CORROSION RESISTANT FLASHING PER WATERPROOFING NOTES CAULK SEAM AT WINDOW INSTALLATION (SEE WATERPROOFING NOTES) CMU WATER RESISTANT COATING (SEE WATERPROOFING NOTES) SET SILL IN FULL MORTAR BED STUCCO OR DECORATIVE CEMENTITIOUS COATING 8" C.M.U. 3Y4" FURRING TO MASONRY WALL PRECAST CONCRETE WIND RESISTANT FLUSH SILL AS MANUFACTURERD BY CAST—CRETE (OR EQUAL) PRE —CAST GONG. LINTEL SEE LINTEL SCHEDULE SIZE & REINFORCEMENT CENTERED 16" LONG 2x8 P.T. (SYP) BLOCKING FOR TORSION SPRING (AS REQUIRED) _- _ __ _ ___ _____________ __ __ _. III IIr( II � _ II u cn N' DIA. WEDGE ANCHOR 3—Y2" EMBEDMENT w/2" _ 2x6x16' 0" P.T. (SYP) ATTACHED SQUARE WASHER w x 3" TAPCONS @16" O.C. / Y4 w/ 1" DIA. MIN. WASHERS 2x6 P.T. (SYP) WOOD JAMB FASTENED w/ "x3—X" (S.S. 304) HILTI KWIK BOLT ® 3 EXPANSION ANCHOR (OR EQUAL) w/ 2" I SQUARE WASHER (SEE BUCK DETAIL) COr GARAGE FLOOR SLAB � _ � 4 w = u �I II CN II II � IIII IIII II II II I I II �- I II �J = FOOTING PER FOUNDATION PLAN NOTE: VERIFY WITH DOOR MANUFACTURER FOR SPECIFIC ATTACHMENT REQUIREMENTS. SEE MANUF. SPECS AND PRODUCT APPROVAL (2)#5 DOWEL WITH 30" OVERLAP STUCCO CEMENT FINISH — FILLED CELL AT JAMB BLOCK (TYP) CMU WATER RESISTANT COATING Li I (SEE WATERPROOFING NOTES) a a a ° 10 P.T. WOOD FIRRING ALL (3) SIDES a CONTINUOUS WOOD TRIM CORROSION RESISTANT FLASHING PER WATERPROOFING NO FES P.T. WOOD BUCK NTH SEALANT PER WATERPROOFING NOTES AND ANCHORED TO MASONRY PER BUCK ATTACHMENT NOTE. APPLY PERIMETER SEALANT CAULK BETWEEN BUCK & WINDOW FRAME (SEE WATERPROOFING NOTES) SEE WATERPROOFING NOTES _. � 4 i ( Ir BEARING HEIGHT SEE EXTERIOR ELEVATIONS GARAGE__________ FLOOR SLAB � ANCHOR DOOR JAMB HEADER TO MASONRY IN STRICT ACCORDANCE WITH MANUFACTURE'S PRODUCT APPROVAL INSTALLATION REQUIREMENTS. SCALE: N.T.S. (2) #5 IN FULLY GROUTED CELLS ADJACENT TO GARAGE DOOR OPENING AS SHOWN D D FI— � nC D 4 2x6 P.T. (SYP) WOOD JAMB FASTENED w/ "0—YZ" (S.S. 304) HILTI KWIK BOLT 3 EXPANSION ANCHOR (OR EQUAL) w/ 2" SQUARE WASHER SPACED 016" O.C. MAX. ` STEEL TRACK BRACKETS TO BE FASTENED TO WOOD 2x6 BUCK w/ PER GARAGE DOOR MANUFACTURER'S SPECIFICATIONS (OR AS NOTED BELOW) OHGD TRACK BRACKETS TO P.T. BUCK 7' HIGH DOOR: (7) Xs" x 1—%" LONG CORROSION RESISTANT HEX HEAD LAG SCREWS SPACED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. K DETAIL SCALE: N.T.S. 1. PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A CMU WATER RESISTANT CC SEAL THE WINDOW / DOOR CAVITY TO PREVENT IT FROM ABSORBING WATER. THE CMU WATER R COATING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. TH APPLICATION OF THE CMU WATER RESITANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF OPENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPENING 8" MINIMUM EACH DIRECT OI CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR TO BUCK INSTALLATIONS. 2. INSTALL BUCKS SO THAT THERE ARE NO EDGE GAPS EXCEEDING 1/8" BETWEEN BUCK AND MASOI 3. PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL DIAMETER BEAD OF SEALANT BETWEEN THE AND THE MASONRY TO PREVENT THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL ENTIRE END OF THE WOOD BUCKS WITH SEALANT TO RESTRICT THE PASSAGE OF LIQUID THROUGH CUT ENDS AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF THE BUCK SHALL BE COA- A LIQUID APPLIED WATER RESISTIVE COATING / SEALANT. 4. PROVIDE PAN FLASHING AT SILL OF WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SE? SLOPED IN A MANNER TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WATER RESISTIVE Bi FOR SUBSEQUENT DRAINAGE. INCORPORATE PAN FLASHING AT HEAD AND SILL AS WELL. PAN F SHALL BE CORROSION RESISTANT (OPTIONAL NOT REQUIRED IF ITEM #1-3 INSTALLED). 5. PROVIDE CONTINUOUS 3/1 BEAD OF SEALANT ON WINDOW / DOOR FRAMES AT ALL PERIMETER C AND BACK SURFACE PRIOR TO WINDOW / DOOR INSTALLATION. 6. AFTER WINDOW/ DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THE BUCK (OR PRECAST AND THE WINDOW / DOOR TO ENSURE A WATER RESISTANT INTERIOR AIR SEAL AROUND THE ENTI PERIMETER. NOTE: WINDOW AND DOOR FENESTRATIONS IN ACCORDANCE WITH FBC R703.4 (1.2) AS PER DETAILS PRO' • FOR WINDOWS, SGD, AND SWING DOORS USE 2X4, 2X6, 2X8, 1X6, 1X8, DOUBLE 1X6, OR ACCEPTABLE. • ALL BUCKS MUST BE PRESSURE TREATED. • ALL BUCKS MUST COVER ENTIRE DEPTH OF THE DOOR/WINDOW JAMB. BUCK ATTACHMENT: • FOR 1 X BUCKS ATTACH TO CMU WALL WITH: 1 1/2" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12- O.C. OR 16" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. • FOR 2 X BUCKS ATTACH TO CMU WALL WITH: 2 1/4" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C., OR 3/16" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. • FOR DOUBLE 1 X BUCKS ATTACH FIRST COURS TO CMU WALL WITH 1 1/2" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C. OR 3/16" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C. ATTACH SECOND COURS TO CMU WALL THRU FIRST COURSE WITH: 2 1/4" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND 12" O.C. OR 3/16" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. OR 1/4" X 2 1/4" TAPCONS AT 4" FROM ENDS AND 12" O.C. G TO PANT ALL Y. E WITH OR IER HING FRONT 1X8 '!S nRA wa SERVICES HONE: (772) 2374W2 W W W.TREASURECOAS7DEAPPINO.COM o 0 q rA z n z a q q U 0 z� ® H w q p z ILL— H H u W G A O v, 1% �0 �J H W0WWM 0 U� 0� p H N � N�' P4A NU°W U F U Pi N U v1 0 0 U 1 �v m® Z o •00000 — > .4> V m m V � (/1 L ®® W J 0 O �W+ CC N{/ Lt ® r J N t®nILL VC6 d (y cnE� p� a n Z w (n ur tj V1 Ln Lu N d AIX41 SCALE: AS NOTED JOB No: 521-0219 S2 #5 VERTICAL BARS WALL REINFORCING ABOVE WALL OPENINGS SHALL BE PROVIDED WITH A STD, ACI HOOK TIED TO LINTEL REINFORCING STEEL (TYPICAL) 30'-0" TYPICAL WALL HEIGHT da 28'-0" WINDOW HEADER HEIGHT PRECAST CONCRETE LINTEL) (SEE SCHEDULE FOR DESIGNATION AND REBAR REQUIREMENTS) REBAR PLACED IN LINTEL MUST BE CONTINUOUS —NO SPLICING ALLOWED 2 COURSES OF 8" BOND BEAM BLOCK (CEMEX/RINKER # T81 OR EQ.) ALONG TOP OF ALL WALLS A REINFORCED WITH (1) #5 BARS CONTINUOUS IN EACH BLOCK 4 a , 4 . a , LINTEL TYPE A 'i °� 8F24-113/21 MIN. SECTION =ARING SET PRECAST CONCRETE WINDOW SILL (SEE DETAIL 5, SHEET—S2) OR POUR IN PLACE CONC. SILL W/ (2) #4 BARS EXTENDED 6" (MIN.) INTO EACH SIDE JAMB BLOCK BEFORE GROUTING WALL CAVITIES (OR DRILL AND SET WITH 5" EPDXY EMBEDMENT) B" CMU BLOCK WALL— REINFORCED AS NOTED ON THE PLANS AND INDICATED IN DETAILS (ALL VERTICAL BARS SHALL BE HOOKED INTO TOP BOND BEAM BLOCK) I (1) #5 VERTICAL BARS —TYPICAL AT ALL WALL OPENINGS LESS THAN 8'-0" WIDE 'PROVIDE (2)—ROWS OF BOND BEAM FOR ALL OPENINGS 8'-0" WIDE AND LARGER SHALL HAVE WALLS WITH HEIGHT OVER BOND (1) #5 BAR IN 2 ADJACENT BLOCK CELLS GROUTED SOLID (SEE PLANS FOR LOCATIONS) TYPICALI PLACEMENT AT WINDOW OPENINGS TOWER SCALE: N.T.S. 2 COURSE OF 8" BOND BEAM BLOCK (RINKER TYPE T81 OR f BAR CONTINUOUS IN EACH COURSE, FILLED SOLID WITH GROUT HORIZONTAL / BEAM BNTH STD. 90* ACI HOOK ARS MINIMUM) (TYPICAL) " BEARING HEIGHT f • s :• • �® TERMINATE HORIZ, REINF. AT THE JOIN (2) FULL HEIGHT VERI REINF. BARS EACH SII OF CONTROL JOINT. 14 ELEVATION VIEW PLAN VIEW TYPICAL CMIJ WALL mail 1111 MINI a �r 4 4, , SET (1) #5 VERT BARS GROUTED SOLID a IN TWO ADJACENT BLOCK CELLS ® END WALLS ABOVE 2ND FLOOR LINE I. #5 REBAR WITH STD. 90- HOOK AT TOP GROUTED SOLID I [DETAIL SCALE: N.T,S, 5LB. BUILDING FELT (MIN.) CONTINUOUS )N ONE SIDE ONLY CAULK AND PREMOLDED FOAM BACKING ROD FILL VOID SOLID WITH MORTAR DURING WALL ASSEMBLY DISCONTINUE HORIZONTAL WALL REINFORCING DET N.T.S. NOTES : 1. SAW CUT BOND BEAMS, TIE BEAMS 1" DEEP TO CONTINUE WALL CONTROL JOINT TO TOP OF WALL. 2. CONTROL JOINT SPACING IS NOT TO EXCEED 25'-0" O.C. IN WALLS WITH MORE THAN 25'—O" OF UNINTERRUPTED MASONRY. REFER TO DWGS. FOR ADDITIONAL SPECIFIED LOCATIONS AS NOTED THUS (WCJ). 3. CONTINUE ALL BOND BEAMS, TIE BEAMS REINF. THROUGH THE JOINT. BLOCK JOINT MATERIALS: A SEALANT SHALL CONSIST OF A HIGH PERFORMANCE EPDXIDIZED POLYURETHANE SEALANT, SUCH AS "DYMERIC 240", AS MANUFAfJTURED BY TREMCO, INC. B BACKER ROD SHALL CONSIST OF CLOSED CELL, CROSS LINKED POLYETHYLENE FOAM ROD, NON —GASSING. PROVIDE PRE—FAB "L" JOINT REINFORCING AT ALL CORNERS 8" CMU BLOCK REINFORCED AS INDICATED ON THE PLANS PLAN VIEW 1 STRAP FOR UPLIFT 1175# 2 STRAPS FOR UPLIFT UP TO 2350# 24'-0" TYPICAL WALL HEIGHT 94 f wo lk e M. L LINTEL TYPE Iq 8F48-1B/2T SECTION A —A irwr� �nUuvfr r1JRIZONTAL JOINT REINFORCEMENT 0 24" O.C. VERTICAL 01:411 SIMPSON HTSM16 COMMON PRE—ENGINEERED ROOF TRUSS (ONLY) (MISALIGNMENT OF GIRDER TRUSS CONNECTOR TO BE APPROVED BY ENGINEER) (4) Y," x 2—Y4" TITEN MASONRY SCREWS SPACED EVENLY 0 LEAST 1—X" FROM TOP, AND INTO TOP CORD. (8) 10d X 3" NAILS 6: STANDARD D♦R . REPAIR Ar:. w STRAP 'it ♦ `., MISALIGNMENT A 2 COURSES OF 8" 13OND BEAM BLOCK (CEMEX/RINKER # T81 OR EQ.) ALONG P OF at: ALL WALLS :'•;:'x %';�_;,` REINFORCED WITH (1) #5 BARS CONTINU US IN 1"- EACH BLOCK A PRECAST CONCRETE LINTEL—x (SEE SCHEDULE FOR DESIGNATION AND REBAR REQUIREMENTS) REBAR PLACED IN LINTEL MUST BE CONTINUOUS -NO SPLICING ALLOWED SET PRECAST CONCRETE WINDOW SILL ( DETAIL 5, SHEET-S2) OR POUR IN PLAT CONC. SILL W/ (2) #4 BARS EXTENDED (MIN.) INTO EACH SIDE JAMB BLOCK BE GROUTING WALL CAVITIES (OR DRILL AN SET WITH 5" EPDXY EMBEDMENT) CMU BLOCK WALL- REINFORCED AS NOTED ON THE PLANS AND INDICATED . DETAILS (ALL VERTICAL BARS SHALL I HOOKED INTO TOP BOND BEAM BLOCK) (1) #5 VERTICAL BARS -TYPICAL AT ALL WALL OPENINGS LESS THAN B'-O" WIDE ALL OPENINGS 8'-0" WIDE AND LARGER SHALL HAV "PROVIDE (2)-ROWS OF BOND BEAM FOR (1) #5 BAR IN 2 ADJACENT BLOCK CELLS GROUTED WALLS WITH HEIGH"I' OVER 8' 0"° SOLID (SEE PLANS FOR LOCATIONS) NT PLACEMENT IOPENINGS SCALE: IL DRAF ING SP VICES MOM :(772)237-9942 www.�tnsnsu•sronsivxa�+rmro.coM .4 qq Q N O ri as tO V� yF+ Y' ^rA F4 ���L^iii Q a z W A 0 z H-I A A z h�l < U Ao a " zxwx"' "WU� 00'a° �+ oA U E L�1 0 C� u t,J ® Z Q d — > 00 m vo Vi V n Z z))» )n W _j O N O oG I -Wu F J 00 0 N r �u_ cn0ulz zh zLu L� cn ® Vl N 0 w m �0 10 —7-0 `21 SCALE: N.T.;S. JOB NO: 521-0219 S3 PROVIDE 2'W BLOCKING ® ALL PLYWOOD SEAMS, 48" NAIL SHEATHING W/ 10D NAILS BACK OF GABLE END. 4" O/C ® PERIMETER ® 6" O/C IN NAIL SEAM W/ 10d FIELD 4" O.C. EA. SI PREFABRICATED WOOD $0P2"x4'x8' TRUSSES 24" ON CENTER CDX PLYWO EE ROOF PLAN SHEATHI G PROVIDE 1/8" SPACING AT PANEL LATERAL BRACING EDGES 10d NAILS AT 6"O.C. IN 2% WOOD FASCIA FIELD AND TYPICAL WALL SECTION INTERMEDIATE NAILED Wf 2-16d SUPPORTS AND 4"o.c. NAILS ® EACH TRUSS @ GABLE ENDS & FIRST — 48" BACK AROUND VERTICAL —� 1/8" SPACE AT PANEL REINFORCEMENT, ENDS PERIMETER AS REQUIRED 2'1 COMPOSITE DECKING 1X COMPOSITE TREAD STRUCTURAL (SEE PLAN) GROUT, AS LANDING 0 11'-8" BEAM SEE REQUIRED - - SCHEDULE = (SEE PLAN) � 2X COMPOSITE RISER CONCRETE 2"X6" P.T.P.T JOIST SIMPSON H2-5A MASONRY SPA. O 1'-4" O.C. W/(10)-8d EACH WALL STRINGER (TYP.) TYPICAL ROOF SHE DETAIL 16" PRE -CAST SIMPSON HUC26-2 _// V f.S. DOWELS MAY BE BENT LINTEL (MIN.) W/(8)-Ya" X 2Ya' 1 UP TO 1 IN. LATERALLY TITEN 2 & (4)-10d TO P.T. BEVELED HANDRAIL PER 6 IN. VERTICALLY JOIST BLOCK (TYP.) \\ 12" COLUMN BLOCK (2)-2X12 CUT SIMPSON LCE4 CONCRETE W/(4)-#5 BARS STRINGERS SPA. W/(24)-16d �19/32" COX PLYWOOD FOUNDATION ® V-4" O.C. (TYP.) P.T. BEVELED - - SHEATHING x (SEE PLAN) BLOCK (TYP.) of ,.. 4X8 P.T. 2x4 S.Y.P, #2 VERT. STRUT ATTACH . (TYP.) TO TOP & BOTT. CHORD W/ (3) IMPROPERLY LOCATED FOUNDATION DOWELS MAY BE BENT TO ALIGN WITH VERTICAL 4X4 P.T. 16d. IF VERT. WEB NOT PROVIDED MASONRY CORES. CONCRETE COLUMN DOWEL BARS THAT ARE OUT OF POSITION ARE EACH END (TYP.) BOTTOM ® -4" BY TRUSS MANUFACTURER PERMITTED TO BE BENT 1 INCH LATERALLY FOR EACH 6 INCHES OF BAR PROTRUDING FROM THE FOUNDATION SIMPSON HGAMIOKTA 2x4 S.Y.P. #2 CROSS BRACING EQUAL EQUAL EQUALL EACH STRINGER ATTACH CROSS BRACING TO STRUTS W/ (2) 16d NAILS. (25 x PSI x 2N DEEP SIMPSON ABU44Z < Z' FOOTING PSI) CONCRETE PAD W/(12)-16d NAILS & N\ — �4 FOOTING WITH (3)-#5 BARS %" ROD EPDXIED " ATTACH TO TRUSS WEB 6 EACH WAY (TYP.) INTO CONCRETE (TYP.) 6" W/ (2) 16d NAILS. lo 1x4 S.Y.P. #2 LATERAL BRACING AT 6'-0" C/C OR PER PLAN. TYPICAL INTERIOR TRUSS CROSS -BRACING BAR BENDING DIAGRAM FOR CONCRETE STAIRS DETAIL N.T.S. N.r.s. N.r.s. COLUMN WITH 9 GAUGE REINFORCEMENT (SEE COLUM VERTICAL REINFORCEMENT DUG 0 WALL SCHEDULE FOR DETAIL) PER PLAN LADDER TYPE CONTINUOUS LATERAL HORIZONTAL BRACING, AS REQ'D. TYPICAL HORIZONTAL REINFORCING PROVIDED I \ REINFORCE - AT EVERY OTHER COURSE (16" VERTICALLY) ! MENT EVERY •. STANDARD NO. 9 LADDER TYPE FOR REIN- I OTHER BLOCK FORCEMENT MUST EXTERIOR WALLS TYPICAL 1 .,`/ �® COURSE REINFORCEMENT MUST EXTEND 4" MIN. AT SIDE WIRES. �\ I \ — VERTICAL\��', REINFORCEMENT PER PLAN SHEATHING I �� � COMPRESSION WEB 45^ FILLED CELL DIAGONAL BRACING REINFORCEMENT (SEE COLUMN (SLOPING OR VERTICAL) SCHEDULE FOR DETAILS) DIAGONAL BRACING `��\ i 9 GAUGE CONTINUOUS LATERAL NAILED TO OPPOSITE O C BRACING SIDE OF WEB DUR-O-wALL LADDER TYPE TO PREVENT LATERAL HORIZONTAL CONT. BOND BEAM, SEE PLANS MOVEMENT --/ REINFORCE— MASONRY AND SCHED. FOR SIZE AND REINF CEILING AT 20'-0" SPACING MENT EVERY UNITS OTHER BLOCK DIAGONALS CORNER DETAIL COURSE WALL DETAIL PLACE METAL LATH/CAVITY CAP OR WIRE FROM BRACED SCREEN OVER CELLS NOT TO BE j BAY AT CONTINUOUS LATERAL PREFAB. 9 GAGE GALV. HORIZ. CORNER FILLED WITH GROUT (SHEET METAL 20'-0"(;) BRACING LOCATED ON JOINT REINF. ® 16" (DUR—O—WAL LADDER AND FELT PROHIBITED) SPACING (BOTH OR NEAR PANEL O TYPE PREFAB CORNER, OR SIMILAR) (EVERY TERM. VERT. WALL ENDS) POINT (8'-0" TO OTHER COURSE) REINF. IN STD. 90' HKS. 10'-0" SPACING) 1 6 GROUT —FILLED CMU CELLS, PLACE GROUT IN LIFTS NOT TO EXCEED 4 FEET; PUDDLE BOTTOM CHORD 6• OR VIBRATE IN PLACE CMU CELLS CONTAINING REINF. SHALL BE 110<<ZONTAL REINFORCEME_NT DETAIL 0 COLUMN OF TRUSSES 1 _ FILLED SOLIDLY WITH GROUT; VERT. CELLS 45" (TYP) N.T.S. . TN��' i 9 GAGE GALV. HORIZ. JOINT REINF. ® SHALL PROVIDE A CONTINUOUS CAVITY, �\ llloillilloiligilligi 16" (DUR-O-WAL LADDER TYPE, OR FREE OF MORTAR DROPPINGS, AND AT SIMILAR) (EVERY THIRD COURSE) LEAST 2" x 3" IN SIZE VERT, REINF. IN GROUTED CELLS, SEE \ PLAN FOR SIZE AND SPACING, PROVIDE NAIL PLYWOOD SHEATING TO \ MATCHING FDN. DOWELS, DI CE 48 BAR A 2X4 DIAGONAL BRACING BLOCKING W/ 10d NAILS 4 IN. OC. CONCRETE CMU UNITS PROVIDE BRACING EVERY OTHER (CMU),— \Y ATTACHED w/(2) 16d NAILS AT TYPICAL JOINT REINFORCEMENT DETAIL COMPLYING WITH ASTM C-90, ERECT AND BRACE WOOD TRUSSES IN ACCORDANCE WITH THE "TRUSS PLATE INSTITUTE" BRACING EACH END AT CORNER IN RUNNING BOND, WITH 3/8" WOOD TRUSSES: COMMENTARY AND RECOMMENDATIONS, BWT-76, BRACING IN THE PLAN OF THE WEB VALLEY TRUSS AT MAXIMUM SPACING OF JOINTS MEMBERS : 48 IN. OC. PREFAB. 9 GAGE GALV. HORIZ. 'IT"a. THE TRUSS FABRICATOR IS TO PROVIDE AND LOCATE CONTINUOUS LATERAL BRACING FOR EACH 2x4 CONT. BLOCKING WALL INTERSECTION JOINT REINF. TRUSS WEB MEMBER, AS REQUIRED. 2-16D TOE NAIL 16" (DUR-D-WAL LADDER TYPE b. RESTRAIN LATERAL BRACING WITH CONTINUOUS DIAGONAL BRACING (MIN. 2" THICK NOMINAL PREFAB TEE, OR SIMILAR) (EVERY OTHER COURSE) FACE SHELLS WITH TYPE M MORTAR; LUMBER). PLACE MORTAR ON CROSS WEBS c. A MINIMUM OF TWO ROWS OF DIAGONAL BRACING IS REQUIRED, ONE AT EACH VERTICAL WEB ADJACENT TO CELLS WHICH WILL MEMBER CLOSEST TO BEARING LOCATIONS. SIMPSON MTS16 TWIST ROOF SHEATHING BELOW y BE GROUTED TO PREVENT LEAKAGE HURRICANE STRAP BRACE THE BOTTOM CHORDS WITH CONTINUOUS LATERAL BRACING SPACED AT 6 FEET, FROM VALLEY NAILED TO THE TOP OF THE BOTTOM CHORD. ATTACH DIAGONALS AT 45 TO THE TRUSSES TO 24" O/C VALLEY TRUSSES SET FIRST COURSE IN FULL LATERAL BRACES (EACH END). IF BUILDING EXCEEDS 60 FEET IN LENGTH, ATTACH LOWER TRUSS — Y"ipd' �� MORTAR BED DIAGONAL BRACING AT 20'-0" SPACING. ®MAX SPACING OF 11•V'Ol 9 GAGE GALV. HORIZ. JOINT REINF. ® CLEAN -OUT OPENINGS AT GROUT TOP CHORD BRACING 6'-0" W IJN 16" (DUR—O—WAL LADDER TYPE, OR FILLED CELLS, REQUIRED IN WALLS /(7 ) 16d LOWER ROOF TRUSSES SIMILAR) (EVERY OTHER COURSE) OVER 4 FEET HIGH a. IF PLYWOOD DECKING IS APPLIED DIRECTLY TO TOP CHORD, PROPERLY LAPPED AND NAILED TO NAILS (TYP.) FOUNDATION, SEE PLAN AND DEVELOP DIAPHRAGM ACTION, BRACING IS NOT REQUIRED. TO VALLEY TRUSS & SCHED. FOR SIZE AND REINF. b. IF PURLINS ARE USED, DIAGONAL TOP CHORD BRACING IS REQUIRED AT EACH END. IF BUILDING TRUSS BELOW EXCEEDS 60 FEET IN LENGTH, ATTACH DIAGONAL BRACING AT 20'-0" SPACING. TYPICAL JOINT REINFORCEMENT DETAIL AT WALL INTERSECTION TYPICAL INTERIOR TRUSS BRACING TYPICAL VALLEY TRUSS DETAIL TYPICAL REINFORCED CMU WALL CONSTRUC I -ION N.T.S. N.T.S. N.T.S. J01 DFA ING SP VICSS PHONE: (772) 237-7942 W W W.TRHASIIRHCOASTDAARI'ING.COM C cq 0 Q A p� z a A U 0 z F"1 W G 5 Q G z u�u r� e;� U O A A O WAUS ®�7 00 A " U U PO G/1 C� lJ 00 � J 01 m mw V LA LL N Z 5 mLU I^ sM/ Q N /1 LL d7HN v e� pcnzr, a Z vai C m V Lina W n a SCALE: N.T.S. JOB No: 521-0219 ,, r TRUSS CONNECTOR SCHEDULE TRUSS ID BEARING POINT TRUSS ACTUAL. UPLIFT CONNECTOR ID CONNECTOR UPLIFT DESIGN FASTENERS NOTES GRI„ GRA A <3100 (1)-MGT 3966¢ (1)-5/0" TERD. ROD EPDXIED 7" MIN. h (22) 10d AT CBS BEARING JC2„ JC4, JCA, JC%, KJC, JSC, GRC C K9f7 (1)-MTS12 & 1000/ (14)-10d Y 1 1/2" I AT SPUD WALL (I)-HGA1D - (6)-1/4" % 1 1/2" SDS C B 129 LUS24 377 (4)-lod X 1 1/2" TO LEDGER & (2)-10d TO TRUSS `) VALLEYS CONT. 100 # PLF { }MTs I6 1 1000 (14) - 10d x 1 1/2" 1 STRAP AT EACH END AND AT 24" O.C. O ALLTHAN OTHERS 1450f SS EACH <1460/ jI-HGAMIOETA 1450 M-1/4" X 1 1/2" BIDS k (4)-1/4" % 2 3/4" TTTEN 2 AT CBS ]DEARING TRUSS COMPANY CHAMBERS LAYOUT DATE - ➢ATE T - NOTE: All, STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED NOTES: ®VAULEY TRUSSES MAY BE ATTACHED N VTCR W/(4)--j9 SD x RV TO SUPPORTING TRUSS AND (3)-/9 SO x W TO VAUZY TRUSS IN LIEU OF WHIG AS STATED, VTCR SE191 BE RMAILKID AT RACE END AND 24" O.C. MAL 2USE SIMPSON EPDXY STRONG TIE SYSTEM WITH 12" M. FOR ANCHOR BOLTS (A.B.). TRUSS NOTES: 1. ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGlam 2. CONTRACTOR TO FROVMR PAUL INC., AND B=tRG IMPARTMENT WITH ENGINEERED TRUSS DRAWINGS BKFORE INSTALLING TRUSSES. 3. CONTRACTOR TO VERIFY ALL ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING, AND DISTALUNG TRUSSES. 4. TRUSS TO TRUSS CONNECTION TO HE PROVIDED BY TRUSS COMPANY. 5. SU TRUSS CONNECTOR SCR. FOR TRUSS 70 WALL CONNECTIONS. 10d x 1 1/2' = SIMPSON'S SUPPLIED EQUIVALENT NAIL FOR COMMON 10 PENNY WEIGHT NAIL DS = SIMPSON'S STRONG -DRIVE 1/4' DIA. WOOD SCREW (OR EQUAL) !+) SINGLE PLY TRUSS (*0) DOUBL_. PLY TRUSS ROOF FRAMINQ PLAN _ SCALE: 114" m V-0" 1. DESIGN UPLIFT REACTIONS HAVE BEEN DETERMINED AND PROVIDED BY THE TRUSS MANUFACTURER'S SHOP DRAWINGS (CHAMBERS; JOB NO.77521; LAYOUT DATE: 09/24/21; CUT -SHEET DATE: 09/28/21) AND REVIEWED BY THIS STRUCTURAL ENGINEER FOR DETERMINATION OF THE TRUSS CONNECTOR TYPE AND ALLOWABLE LOADS NOTED IN THE TRUSS TO WALL CONNECTOR SCHEDULE. 2. LATERAL SHEAR FORCES (F1) AND TRANSVERSE LOADS (F2) ON TRUSS CONNECTORS HAVE BEEN EVALUATED IN ACCORDANCE WITH THE 2020 FBC-RESIDENTIAL CODE. 3. ALL TRUSS TO PERIMETER 8' CMU WALL CONNECTORS SHALL BE META 12; UNLESS DESIGNATED OTHERWISE ON THE ROOF FRAMING PLAN. 4. MINIMUM 4" EMBEDMENT WITH MINIMUM EDGE DISTANCE OF 2" REQUIRED FOR META STRAPS CAST -IN -PLACE. 5. TRUSS ANCHOR -META 16 STRAP SHALL BE PROVIDED WITH "TSS" MOISTURE BARRIER SEAT. 6. ANCHORS HANGERS, AND TIE STRAPS AS SHOWN IN THE ABOVE SCHEDULE ARE IDENTIFIED ON THE ROOF FRAMING PLAN. SUBSTITUTION OF APPROVED EQUAL OR BETTER ANCHORS, HANGERS AND TIE STRAPS FOR THE SPECIFIED ALLOWABLE LATERAL A UPLIFT LOADS ARE ACCEPTABLE. 7. THE SIMPSON STRONG -TIE CONNECTOR ALLOWABLE LOAD VALUES SHOWN IN THE ABOVE SCHEDULE ARE THE C-2018 PUBLISHED VALUES BASED ON WOOD TRUSSES FABRICATED USING SOUTHERN YELLOW PINE AND INCLUDE AN APPLIED 1/3 STRESS INCREASE FOR WIND LOAD DURATION ONLY, IN ACCORDANCE WITH NDS ALLOWABLE STRESS DESIGN PERMITTED FOR WOOD OR FASTENERS IN WOOD. 8. PROVIDE SUITABLE PRE -FORMED OR LIQUID APPLIED MOISTURE BARRIER BETWEEN BOTTOM CHORD OF ROOF TRUSS AND TOP OF MASONRY WALLS, WHEN BARRIER IS NOT PROVIDED WTH TRUSS CONNECTOR. 9. SIMPSON STRONG TIE ANCHORS AND STRAPS PRODUCTS SHALL BE HOT DIPPED (H.D.) ZINC -GALVANIZED PER ASTM A123 TO G90 AS MEASURED BY ASTM A653, OR BETTER. 10. ALL CARBON STEEL ANCHOR BOLTS, FASTENERS, AND NAILS, UNLESS OTHERWISE SPECIFIED, SHALL BE HOT DIPPED ZINC -GALVANIZED IN ACCORDANCE WITH ASTM A153 STANDARDS. 11. ANCHOR BOLTS (A.B.) SHALL CONSIST OF "J" BOLTS WITH MIN. EMBEDMENT OF 10" CAST -IN -PLACE AT TIME OF WALL GROUTING WORK. SETTING ACHOR BOLTS AFTER WALL CONSTRUCTION SHALL CONSIST OF ALL THREADED ROD (ATR) DRILLED AND ANCHORED WITH HILD HIT RE-500 INJECTION EPDXY SYSTEM (OR SIMPSON EPDXY -TIE (ET) EPDXY ADHESIVE) IN STRICT ACCORDANCE 1WTH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. MINIMUM EMBEDMENT DEPTHS SHALL BE AS FOLLOWS: ANCHOR DIA. DRILL HOLE DIA. (MAX.) EMBEDMENT DEPTH (MIN.) w 'Ne 12" 'Y47 1" 12" %" 1" 12" Hatch Legend WALL HEIGHT 24'-0' 3/12 CEILING WALL HEIGHT 30'-0" 1iWALL HEIGHT 1 WALL HEIGHT 12'-0°' FLOOR FRAMING PLAN SCALE: 114" =1'-0" SRG. C 12' 01 IN DRAYLING SERVICES PHONE: (772) 2377942 W W W.TREMURPCOASTDRAPTING.COM 0 N ti VI a � z a 0 z 0 Q 001 F �1 9 dP� E� c� a�I �T� c� U ) � M A 0 4� �0 U� QO a� N��,„ U 1 lJ w Z p � CO � m M U LU J N U LL n Z rF3 U1 o I-WUin ® Ln F J L'j CD V J06iz v ® 0UIZrl a n Z UJ Ul U) ® W INS a SCALE: 1/4" = 1'_0" JOB No: 521-0219 RI ELECTRIC LOAD N PER NEC ___ ........ __....... _............. 1,326 sq. ft. x 3VA (GENERAL LIGHTING) .... --............ 3,978 VA GARBAGE DISPOSAL 900 REFRIGERATOR 1,200 MICROWAVE 1,500 DISHWASHER 1,800 RANGE 5,000 OVEN 6,000 HOOD 500 DRYER 5,000 WASHER 1,500 WATER HEATER 5,000 3 FANS 0 240 720 EXHAUST FANS 3 0 240 720 OVERHEAD GARAGE DOOR OPENER (2) 1,200 OPT. POOL PUMP 1,800 OPT. POOL HEATER 6,000 OPT. WELL PUMP 2,000 OPT. IRRIGATION PUMP 2,000 MISC. 10,000 TOTAL 56,818 VA FIRST 10 KW 0100% 10,000 REMAINDER 040% 18,727.2 TOTAL 28,727.2 A/C HEAT 0 65% 10,000 TOTAL 38,727.2 VA TOTAL/240V 161.36 AMP. USE 200 AMP SERVICE PANEL U#1/0 CU #3/0 RHHN� RVICE CABLE WITH (1) #4 GROUND 200 AMP PANEL MAIN BREAKER 40 CIRCUIT 2 POLE, 1 PHASE SERVICE GROUND TO 5/8"x20'-O" EMBEDDED IN FOUNDATION (OR NEC EQUAL) EXHAUST VENT THRU' SOFFIT EXHAUST VENT THRU' ROOF 2" RGS OR — IMC CONDUIT W/2 #3 0 THHN +(1) 1 0 CU CU OR EQUAL ELECTRICAL SYMBOL LEGEND SWITCH $ DIRECT WIRE ® LIGHT FIXTURE rl 3- WAY SWITCH $3 THERMOSTAT ® CEILING MOUNTED 4-WAY SWITCH 4 PHONE/CAT5 LIGHT FIXTURE rpl w/PULL SWITCH \ DIMMER SWITCHo TV JACK 4 120V OUTLET SMOKE DETECTOR 45 HI HAT ��R} iRr HALF —HOT OUTLET (p CAREBON MONOXIDE Q VAP{OR PROOFDET AT 220V OUTLET 0 EXHAUST FAN 5a cFrn FLOOD LIGHT GFI OUTLET PUSH BUTTON 1=7 WP GFI OUTLET Q� DOOR CHIMES "9'R CEILING FAN with rGFI ALARM PAD o LIGHT QUAD OUTLET PANEL LeE�_] FUSE DISCONNECT METER rc�j FRAME SIZE # POLES FUSE SIZE FLUORESCENT ORESCENT CEILINGx (NEMA ENCLOSURE)GARAGE IG DOOR �'1. °Dz SPEAKER _'OPENER - JUNCTION BOX LIGHT FIXTURE WALL MOUNTED GARBAGE DISP. FINISHED AFF FLBOVE OOR HB TO SwTCH"', ABOVE II / II II II II II II / / I I I I II II II II II II I { i 1 \ \ II \ METER (MIN RATING= 10,000 A/C INTERRU TING) ELECTRICAL NOTES: SMOKE DETECTORS TO BE 110V w/ BATTERY BACK UP —ARC FAULT CIRCUIT. SMOKE DETECTORS TO BE LOCATED AS SHOWN. SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE. PROVIDE ARC —FAULT PROTECTION FOR ALL BRANCH CIRCUIT OUTLETS, PER N.E.C. 210.12 EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. PROVIDE PHONE AND TV OUTLETS, VERIFY LOCATIONS. MICROWAVE OUTLET TO HAVE DEDICATED CIRCUIT. ALL BATH, GARAGE, KITCHEN, AND EXTERIOR OUTLETS WHERE NOTED TO HAVE GROUND FAULT INTERRUPT. PROVIDE LEGIBLE DIRECTORY AT PANEL INDICATING INDIVIDUAL CIRCUITS. ALL WORK SHALL COMPLY WITH ALL LOCAL STATE AND NATIONAL CODES. CARBON MONOXIDE DETECTORS TO BE INSTALLED WITHIN 10' FROM ALL BEDROOMS. PROVIDE TAMPER RESISTANT RECEPTACLES PER N.E.C. 406.11. RUN CONDUIT WITH PULL STRING FOR FUTURE POOL EQUIPMENT. CONTACT WINDOW MANUFACTURER ABOUT REQUIREMENTS TO MEET THE SHGC & U FACTOR. THE SHGC AND U FACTOR TO BE COORDINATED WITH ENERGY CALCULATIONS PROVIDED TO MEET ENERGY CODES REQUIRED.O ELECTRICAL CONTRACTOR TO VERIFY ELECTRICAL CALCULATIONS AND SERVICE REQUIREMENTS. M GFI 42-4E 220V GFI SINK L==J❑o I OF I -42927FOF -- / --� I I I \\\ I I I I I \ / ®l GF14 GFI � I it II / 2" RGS OR SCH. ■ 0 PVC CONDUIT 3) #4/0 THHN CU ®®® R EQUAL SERVICE ■ DETERMINED BY ® T Aaov�_ POWER COMPANY \ CU WIRE BOND :,i ■ \ TO COLD WATER SERVICE PIPE FROM FPL / TC SNATCH- \ rUNDREGROUND ^I ABOVE V -- _ III \\ ® \ ■ /// TRICAL RISER SCALE: NTS I PRE -WIRE LANDSCAPE LIGHTING (FIELD LOCATE BY BUILDER) TO LANDSCAPING LIGHTING I� la8Fwl ®oz Iq�3LL LL V l0RE 8� / I��LL�I I®wb� V I r-� \ ( pDW 42. g 2 1 \ / PENDANT LIGHTS I _l I II l � / R \ R I \\ � R I 1 1 11 I \ I\ \ ro l TO LIGHT BELOW - — ^� \/ / / - \ \ I OHAN / TO EXTERIOR LIGHTS -- � / MN U 7 I / \ STORAGE LIGHTING®----®---------_ \ ABOVE / \\-------------- 00 POOL PUMij—D ELECTRIC CONNECTION FOR U WELL PUMP, WATER WELL TREATMENT SYSTEM AS PUMPS:- M NECESSARY (FIELD LOCATE) k WP GFI LANDSCAPE SUB -OUT PANEC. L I u I D PANEL m O II 1 I I II I I I I I I I II I I I I I I I it / ORAF ING SERVICES PHONE: M2) 2374942 wwW.TREASURECOASMRAFP G.COM cq N 0 cq N IC � Q 0 A A 0 z N m Q M A z W U M i I �-I 0 - w w cc) o �x �m 00 a't N] 0A a� �U�wW C)xEu u a U �a Q •� z ® m M V ~ Z U n Ln LLU JOLWLy O Q It W J N ®� N/!cd0U) , a n " Z w canIn In N 0 / W r� 0- A l IC --Z0 ''Z� SCALE: 1/4" = V-0" JOB No: 521-0219 E I a ,p . >, ®LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read and given special attention to all persons installing trusses. SPACING NOTE All trusses are to be set 2'-0" on center except as noted. MULTIPLE PLY TRUSSES MUST BE FASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE IF MULTIPLE PLY. DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Sp nor less Spre der Bar 60 degrees or less e, Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !! Ak ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER 13AR OF 41'- 46'IN LENGTH!! Do not set floor trusses upside down! Refer to engineering drawings. Recommended STRONGBACK for Floor Trusses Refer to information on truss engineering drawings. (2) led nails (� tap & Whom of 2X4 vertical block. 2x6 (MIN) STRONGBACK restrained at ca h end_ Secure wl(3)16d nails @ each vedical. Locale STRONGBACK as close to bottom.0rd as possible. STRONGBACKS are recommended to MINIMIZE VIBRATION ll2 span 12. span —� --�4ppv x 213 to -- o Tag line Tag 1 112 of SpanappmX REFER TO BCSI REFER TO BCSI Truss must be set this way if crane is used. Truss must be set this way if crane is used. Truss is an example, your truss may not match. Truss is an example, your truss may not match. Insist crane operator sets truss this way. Insist crane operator sets truss this way. WARNING,±1 ! The size of these trusses makes it necessary that they e set by a profeesional builder familiar with and experienced in the problems and dangers of setting large span trusses. The builder and erector should consult with an engineer licensed in Florida specializing in wood roof trusses about the safe erection of these trusses. The engineer should be at the job site when trusses are erected to provide supervision and advice. -__ AIR HANDLER NOTE Unless noted elsewhere on this layout, these trusses are not designed for air handlers in the roof or for any other A/C requirements. This may be in conflict with building code and A/C Design requirements. Consult with Building Department and A/C Contractor. All load bearing walls, headers, beams, & lintels must be in place o at indicated height before trusses are installed. REPRESENTS THE LEFT SIDE OF EACH TRUSS DRAWING REPRESENTS A HANGER HANGER SCHEDULE USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN CARRIED TRUSS CARRYING TRUSS HANGER ID FASTENER FOR CARRIED TRUSS FASTENER FOR CARRYING TRUSS =11: F—L 'Please refer to Standard Engineering package for genera( instuction on installing hangers 1 Od=D.148" x 3" 16d=D. 162" x 3 1/2" SEAT PLATES BY CHAMBERS TRUSS Hatch Legend WALL HEIGHT 24'-0' 3/12 CEILING WALL HEIGHT 30'-011 WALL HEIGHT 1011-011 WALL HEIGHT 12'-011 0 T M SQUARE CUT END 12 2X4 TOP CHORD 6 r- WALL HEIGHT 24' END DETAIL: @ VAULT 4-03 Z -13 12 SQUARE CUT END 12 2X4 TOP CHORD � WALL HEIGHT VARIES' END DETAIL: TYPICAL 4-03 O O r ____MATCH POINT 35-QD-DD ✓cK 12-Stage Wall 1C 130'- --- N 0 PLUMB CUT END 4X2 TOP CHORDS TOP OF LEDGER @ 10'-9 1/4" END DETAIL: FLOOR 0 Co - 17-01-00 ----/- _ -- w ODD SPACE 1-11-08 , 2-00-00 i9 Ll 1-11-OB 1 1/2" LEDGER BY OTHERS BOTTOM FOLLOWS 3/12 — µ k CEILING @ "GR, GR3, GR4" 35 sRc.cao ------------------- 1 1/2" LEDGER BY OTHERS I 2-00-00 1 2.00 0 6-00-00 2-00-011 4-02 15 6-00-00 TOP FOLLOWS 6/12 ROOF @ "GR, GR3, GR4" l 4-02-15 41-00-00 NOTE: COLUMN'S SUPPORT "GR","GR3" & "GR4" GIRDERS. GIRDERS "'- ---� ARE DESIGNED @ A CEILING HEIGHT OF 24'-0". 4-02-15 6-00-00 _ 4-02-15 MU1160111111111 HIP CARRIER LOCATED AS DI9ENgrIAM ON'LAYOLN -- CORNOER JACK, ARL N T BEVLLkp SE 5-ANCARD r 2 ENCIINEININ 35 O[ tl DRN R 111 OILY RIF CORNER DETAIL OVERHANGS NOT ]HCYJN `OR CLARITY EXCEPT AS NOTED @ TOWER 6-00-00 3 1/2" x 3 112" 1 /211 COLUMN LOCATION FOR TRUSSES "GR, GR3, GR4" EXTERIOR OF HEXAGON FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED The undersigned acknowledges did agrees: 1. Trusses will be made in sTct accordance with this truss placement diagram layout, which is the sole authority for. determining successful fabrication of the trusses. 2. All dimensions in this layout have been verified by the undersigned. 3. Unless written notice isprovidedby certified mail to Chambers Truss within ten (10) days of delivery the undersigned agrees that no bac charges will be allowed. In the event such written notice is furnished Chambers Truss shall have three (3) business das in which to begin repairs required, or to substitute other trusses, at Chambers option. After 10 days of delivery remedy will be according to Florida statute 558. 4. The undersigned acknowlegas receipt of "BCSI" summary sheet by TPI & WTCA 5. Delivery Is to job site. It Is the buyers responsibility to make the job site suitable for delivery. Chambers Truss has the sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will be responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has to redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is responsible to Chambers Truss ]or towing casts due to site conditions. 6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour fee for revisions may be charged by Chambers Truss, 7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price. Invoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of delivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss reasonable attorney's fee for collections in event of payment not timely made. 1-112 % per month service charge will be'. added for all sums not paid within terms. 8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein. 9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees payment when due of any andall indebtedness owed to Chambers Truss by any entity receiving material and the undersigned agrees to pay suchls lindebtedness including attorney's fees, if default in payment for material be made by the recipient, I 10, In the event of any litigaLn concerning this agreement, the items furnished hereunder or payments referred to herein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida, 11. Design responsibilities ire per ONational Standard And Recommended Guidelines On Responsibilities For Construction Using Metal Plate Connected Wood Trusses ANSIlfPfWTCA 4 - 20021 12. Warranty is per Chambers Truss Warranty attached, DATED SIGNED_!_ FOR TITLE A spreader bar ay be required per "BCSI" to prevent injury & damage. o Multiple ply trusses Tiust be fastened together per engineering before they are set, failure to do so can result in roof collapse. Temporary and permanent bracing are required and can save life and property an� is the responsibility of the truss erector. 'AN Study the conten�s of the information packet included on delivery before I setting trusses. Trusses must be set and braced per design to prevent injury & damage. -Ack. trusses must be set plumb and square I Do not set buns or stack of plywood, roofing material or any other concentrated loads on trusses, this can cause collapse, 0 NOT INSTALL TRUSSES USING THIS USE PLA DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC eanerN venue Fort Pierce, Florida 34982.6423 800-551-5932 Fort Pierce 772-465-2012 Fax 772.465-8711 Vero Beach 772.569.2012 Stuart 772-286 3302 Web Site: CHAMBERSTRUSS.COM Email: MAIL@CHAMBERSTRUSS.COM �reA'KI I6 20 7-1 � �vre✓1SiC-5 MI I'EK VERSION 7:4. 1. 431 LOADING05SIGN CRITERIA REDUCIBLE PER CODE SUCH AS SEC 1304.6.1 DESIGN CRITE UA county ST. LUCIE Building Department ST. LUCIE CO. Wind Design Criteria ASCE 7-16 Wind Design Method MWFRS(Directional)/C-G hybrid Wind ASCE 7-16 Roofing Material Shingle or Shake I.. Loading in PSF Roof R.D.L. Floor Top Chord Live 20 40 Top Chord Dead 7 4.2 30 Bottom Chord Live *10-Non Conccurent 0 Bottom Chord Dead 10 3 5 Total Load 47 T2 75 L... Duration Factor 1.25 1.0 Wind Speed 170mph Top Chord C.B. Sheathing by builder I.I Bottom Chord C.B. Sheathing by builder Highest Mean Height 32' Building Type Enclosed Building Category II: Non Restrictive Exposure Category C>Open Terrain with scattered obstructions Miles from Ocean 5 Conforms to Florida B ilding Code 2020 R.D.L.=Restraining De d Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record Chambers Truss I c. Drawing Name: 77521 SCALE: 1l4" = 11-01r 144 total trusses, 5 unique designs Designer: RAC Reviewed by: , Date: 05114/21 REVISED 09/24/21 FOR MARK & AN ERICA OCCHUIZZO DESCRIPTI N: OCCHUIZO RESIDENCE Page 1 of 1 CUStOMER INITIALS EACH PAGE 77521