Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method r. HECEIVED Project Name: OCCHUIZZO RESIDENCE Builder Name: Street: TURNPIKE FEEDER ROAD Permit Office: ST LUCIE COUNTY DECy City, State, Zip: FORT PIERCE, FL, Permit Number: L g 202 Owner: Jurisdiction: ST LUCIE COUNTY At t_Hdi®un Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate ff'I�Ili1� ty 1. New construction or existing New (From Plans) 10. Wall Types(1874.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1874.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d• N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1326.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1326.00 ft2 6. Conditioned floor area above grade (W) 1326 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 7. Windows(167.7 sqft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 140 a. U-Factor: Sgl, U=0.65 167.67 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1326.0 sqft.) Insulation Area EF: 0.980 a. Raised Floor R=30.0 1326.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.126 Total Proposed Modified Loads: 52.61 PASS Total Baseline Loads: 58.55 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance with the Florida Energy Code. PREPARED .QAC- Before construction is completed DATE: 4- 9- ?0 this building will be inspected for - d compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT BUILDING OFFICIAL: DATE: r DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FILE COPY 4/16/2021 12:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: OCCHUIZZO RESIDENCE Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 1326 Lot # Owner Name: Total Stories: 2 Block/Subdi%ision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: TURNPIKE FEEDER R Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/E)asting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75. 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1326 16080 SPACES -- Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FOYER BELOW 126 2520 No 0 1 Yes Yes Yes 2 GREAT RM 390 5460 No 0 1 Yes Yes Yes 3 KITCHEN 198 1980 Yes 0 1 Yes Yes Yes 4 MASTER BEDROO 327 3270 No 0 1 1 Yes Yes Yes 5 M W IC 1 49 490 No 0 1 Yes Yes Yes 6 M W IC 2 40 400 No 0 1 No Yes Yes 7 AHU CLST 9 90 No 0 1 No Yes Yes 8 M BATH 159 1590 No 0 1 Yes Yes Yes 9 M TOILET 28 280 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor FOYER BELOW ---- ---- 126 ftz 30 1 0 0 2 Raised Floor GREAT RM ---- ---- 390 ftz 30 1 0 0 3 Raised Floor KITCHEN ---- ---- 198 ftz 30 1 0 0 4 Raised Floor MASTER BEDRO ---- ---- 327 ftz 30 1 0 0 5 Raised Floor M W IC 1 ---- ---- 49 ftz 30 1 0 0 6 Raised Floor M W IC 2 ---- ---- 40 ftz 30 1 0 0 7 Raised Floor AHU CLST ---- ---- 9 ftz 30 1 0 0 4/16/2021 12:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Raised Floor M BATH ---- ---- 159 ft2 30 1 0 0 9 Raised Floor M TOILET ---- ---- 28 ft2 30 1 0 0 ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck .Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1483 ft2 0 ft2 Light N 0.3 No 0.9 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1326 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) FOYER BELOW 30 Blown 126 ft2 0.1 Wood 2 Under Attic (Vented) GREAT RM 30 Blown 390 ft2 0.1 Wood 3 Under Attic (Vented) KITCHEN 30 Blown 198 ft2 0.1 Wood 4 Under Attic (Vented) MASTER BEDRO 30 Blown 327 ft2 0.1 Wood 5 Under Attic (Vented) M W IC 1 30 Blown 49 ft2 0.1 Wood 6 Under Attic (Vented) M W IC 2 30 Blown 40 ft2 0.1 Wood 7 Under Attic (Vented) AHU CLST 30 Blown 9 ft2 0.1 Wood - 8 Under Attic (Vented) M BATH 30 Blown 159 ft2 0.1 Wood 9 Under Attic (Vented) M TOILET 30 Blown 28 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 N Exterior Concrete Block - Int InstlfOYER BELO 4.1 4 0 20 0 80.0 ft2 0 0 0.3 0 2 S Exterior Concrete Block - Int InsiffOYER BELO 4.1 4 0 20 0 80.0 ft2 0 0 0.3 0 3 SW Exterior Concrete Block - Int InsdfOYER BELO 4.1 4 3 20 0 85.0 ft2 0 0 0.3 0 4 W Exterior Concrete Block - Int InsdFOYER BELO 4.1 6 0 20 0 120.0 ft2 0 0 0.3 0 5 NW Exterior Concrete Block - Int Inst1fOYER BELO 4.1 4 3 20 0 85.0 f1:2 0 0 0.3 0 6 N Exterior Concrete Block - Int Insu1GREAT RM 4.1 25 0 14 0 350.0 ft2 0 0 0.3 0 7 W Exterior Concrete Block - Int InsuIGREAT RM 4.1 6 0 14 0 84.0 ft2 0 0 0.3 0 8 N Exterior Concrete Block - Int Insul KITCHEN 4.1 11 0 10 0 110.0 ft2 0 0 0.3 0 9 E Exterior Concrete Block - Int Insul KITCHEN 4.1 18 0 10 0 180.0 ft2 0 0 0.3 0 _ 10 E Exterior Concrete Block - Int InsuMASTER BE 4.1 17 0 10 0 170.0 ft2 0 0 0.3 0 11 S Exterior Concrete Block - Int InsuMASTER BE 4.1 18 0 10 0 180.0 ft2 0 0 0.3 0 12 S Exterior Concrete Block - Int Insul M WIC 1 4.1 7 0 10 0 70.0 ft2 0 0 0.3 0 13 S Exterior Concrete Block - Int Insul M BATH 4.1 11 0 10 0 110.0 ft2 0 0 0.3 0 _ 14 W Exterior Concrete Block - Int Insul M BATH 4.1 17 0 10 0 170.0 ft2 0 0 0.3 0 4/16/2021 12:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 SW 3 Metal Low-E Single SW 3 Metal Low-E Single W 4 Metal Low-E Single NW 5 Metal Low-E Single N 6 Metal Low-E Single N 8 Metal Low-E Single E 10 Metal Low-E Single S 13 Metal Low-E Single W 14 Metal Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 7.7 ft2 1 ft 4 in 1 ft 4 in 8.0 ft2 1 ft 4 in 1 ft 4 in 16.0 ft2 1 ft 4 in 1 ft 4 in 16.0 ft2 1 ft 4 in 1 ft 4 in 48.0 ft2 1 ft 4 in 1 ft 4 in 12.0 ft2 1 ft 4 in 1 ft 4 in 36.0 ft2 1 ft 4 in 1 ft 4 in 8.0 ft? 1 ft 4 in 1 ft 4 in 16.0 ft2 1 ft 4 in 1 ft 4 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds None None None None None Exterior 5 Exterior 5 Exterior 5 Exterior 5 None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000385 1340 73.52 138.02 .1406 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 29.4 kBtu/hr 882 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS V # ---- Supply ---- Location R-Value Area ---- Return ---- Location Area Leakage Type Air CFM 25 CFM25 Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 4/16/2021 12:15 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: ling Jan Jan Feb Feb Mar �X� A,, I a, Mer JM Jun Jun rj Jul Jul r1ju, Aug Sep ct Oct €X� H Nov Nov Dec Dec € Jan Venting Feb Mar Apr May Jun 11 Aug L1 Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM . 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 FOYER BELOW Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST- Default(8 lbs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/s .ft. ft2 ft 0.3 M TOILET 4/16/2021 12:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENTPRITERIA CEIV�p Project Name: OCCHUIZZO RESIDENCE Builder Name: Street: TURNPIKE FEEDER ROAD Permit Office: ST LUCIE COUNTY, C City, State, Zip: FORT PIERCE, FL, Permit Number: Q %'021 Owner: Jurisdiction: ST LUCIE COUNTY St. Lucie Coun tY Design Location: FL, Fort Pierce W = U Permitting COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and Wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. � 4/16/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) r"�pli�nt�Soffiiv (opy Page 1 of 1