HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
r.
HECEIVED
Project Name: OCCHUIZZO RESIDENCE
Builder Name:
Street: TURNPIKE FEEDER ROAD
Permit Office: ST LUCIE COUNTY
DECy
City, State, Zip: FORT PIERCE, FL,
Permit Number:
L g 202
Owner:
Jurisdiction: ST LUCIE COUNTY
At t_Hdi®un
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate ff'I�Ili1� ty
1. New construction or existing New (From Plans)
10. Wall Types(1874.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1874.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 1
d• N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1326.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1326.00 ft2
6. Conditioned floor area above grade (W) 1326
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
7. Windows(167.7 sqft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 140
a. U-Factor: Sgl, U=0.65 167.67 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
29.4 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.333 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1326.0 sqft.) Insulation Area
EF: 0.980
a. Raised Floor R=30.0 1326.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.126 Total Proposed Modified Loads: 52.61
PASS
Total Baseline Loads: 58.55
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
PREPARED .QAC-
Before construction is completed
DATE: 4- 9- ?0
this building will be inspected for
- d
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT
BUILDING OFFICIAL:
DATE: r
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FILE COPY
4/16/2021 12:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: OCCHUIZZO RESIDENCE Bedrooms: 1
Address Type:
Street Address
Building Type: User
Conditioned Area: 1326
Lot #
Owner Name:
Total Stories: 2
Block/Subdi%ision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
TURNPIKE FEEDER R
Permit Office: ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type: Detached
FL,
New/E)asting: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75. 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1326 16080
SPACES
-- Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 FOYER BELOW
126 2520 No 0
1 Yes
Yes
Yes
2 GREAT RM
390 5460 No 0
1 Yes
Yes
Yes
3 KITCHEN
198 1980 Yes 0
1 Yes
Yes
Yes
4 MASTER BEDROO
327 3270 No 0
1
1 Yes
Yes
Yes
5 M W IC 1
49 490 No 0
1 Yes
Yes
Yes
6 M W IC 2
40 400 No 0
1 No
Yes
Yes
7 AHU CLST
9 90 No 0
1 No
Yes
Yes
8 M BATH
159 1590 No 0
1 Yes
Yes
Yes
9 M TOILET
28 280 No 0
1 No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Raised Floor
FOYER BELOW ---- ----
126 ftz
30
1 0
0
2 Raised Floor
GREAT RM ---- ----
390 ftz
30
1 0
0
3 Raised Floor
KITCHEN ---- ----
198 ftz
30
1 0
0
4 Raised Floor
MASTER BEDRO ---- ----
327 ftz
30
1 0
0
5 Raised Floor
M W IC 1 ---- ----
49 ftz
30
1 0
0
6 Raised Floor
M W IC 2 ---- ----
40 ftz
30
1 0
0
7 Raised Floor
AHU CLST ---- ----
9 ftz
30
1 0
0
4/16/2021 12:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Raised Floor M BATH ---- ----
159 ft2
30
1
0
0
9 Raised Floor M TOILET ---- ----
28 ft2
30
1
0
0
ROOF
V
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
.Pitch
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1483 ft2
0 ft2
Light
N
0.3
No 0.9
No 0
26.57
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1326 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) FOYER BELOW
30
Blown
126 ft2
0.1
Wood
2
Under Attic (Vented) GREAT RM
30
Blown
390 ft2
0.1
Wood
3
Under Attic (Vented) KITCHEN
30
Blown
198 ft2
0.1
Wood
4
Under Attic (Vented) MASTER BEDRO
30
Blown
327 ft2
0.1
Wood
5
Under Attic (Vented) M W IC 1
30
Blown
49 ft2
0.1
Wood
6
Under Attic (Vented) M W IC 2
30
Blown
40 ft2
0.1
Wood
7
Under Attic (Vented) AHU CLST
30
Blown
9 ft2
0.1
Wood -
8
Under Attic (Vented) M BATH
30
Blown
159 ft2
0.1
Wood
9
Under Attic (Vented) M TOILET
30
Blown
28 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
0
1
N
Exterior Concrete Block - Int InstlfOYER BELO
4.1 4
0 20
0
80.0 ft2
0
0
0.3
0
2
S
Exterior Concrete Block - Int InsiffOYER BELO
4.1 4
0 20
0
80.0 ft2
0
0
0.3
0
3
SW
Exterior Concrete Block - Int InsdfOYER BELO
4.1 4
3 20
0
85.0 ft2
0
0
0.3
0
4
W
Exterior Concrete Block - Int InsdFOYER BELO
4.1 6
0 20
0
120.0 ft2
0
0
0.3
0
5
NW
Exterior Concrete Block - Int Inst1fOYER BELO
4.1 4
3 20
0
85.0 f1:2
0
0
0.3
0
6
N
Exterior Concrete Block - Int Insu1GREAT RM
4.1 25
0 14
0
350.0 ft2
0
0
0.3
0
7
W
Exterior Concrete Block - Int InsuIGREAT RM
4.1 6
0 14
0
84.0 ft2
0
0
0.3
0
8
N
Exterior Concrete Block - Int Insul KITCHEN
4.1 11
0 10
0
110.0 ft2
0
0
0.3
0
9
E
Exterior Concrete Block - Int Insul KITCHEN
4.1 18
0 10
0
180.0 ft2
0
0
0.3
0
_ 10
E
Exterior Concrete Block - Int InsuMASTER BE
4.1 17
0 10
0
170.0 ft2
0
0
0.3
0
11
S
Exterior Concrete Block - Int InsuMASTER BE
4.1 18
0 10
0
180.0 ft2
0
0
0.3
0
12
S
Exterior Concrete Block - Int Insul M WIC 1
4.1 7
0 10
0
70.0 ft2
0
0
0.3
0
13
S
Exterior Concrete Block - Int Insul M BATH
4.1 11
0 10
0
110.0 ft2
0
0
0.3
0
_ 14
W
Exterior Concrete Block - Int Insul M BATH
4.1 17
0 10
0
170.0 ft2
0
0
0.3
0
4/16/2021 12:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
8
9
SW 3 Metal Low-E Single
SW 3 Metal Low-E Single
W 4 Metal Low-E Single
NW 5 Metal Low-E Single
N 6 Metal Low-E Single
N 8 Metal Low-E Single
E 10 Metal Low-E Single
S 13 Metal Low-E Single
W 14 Metal Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
0.65 0.25 Y
7.7 ft2 1 ft 4 in 1 ft 4 in
8.0 ft2 1 ft 4 in 1 ft 4 in
16.0 ft2 1 ft 4 in 1 ft 4 in
16.0 ft2 1 ft 4 in 1 ft 4 in
48.0 ft2 1 ft 4 in 1 ft 4 in
12.0 ft2 1 ft 4 in 1 ft 4 in
36.0 ft2 1 ft 4 in 1 ft 4 in
8.0 ft? 1 ft 4 in 1 ft 4 in
16.0 ft2 1 ft 4 in 1 ft 4 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
None
None
Exterior 5
Exterior 5
Exterior 5
Exterior 5
None
None
None
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000385
1340 73.52 138.02 .1406
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
29.4 kBtu/hr 882 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric None
Exterior
0.98 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
V #
---- Supply ----
Location R-Value Area
---- Return ----
Location Area Leakage Type
Air CFM 25 CFM25
Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1
Attic 6 140 ft2
Attic
14 ft2 Default Leakage
AHU CLST (Default) c(Default) c
1 1
4/16/2021 12:15 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
ling Jan
Jan
Feb
Feb
Mar
�X�
A,,
I
a,
Mer
JM
Jun
Jun
rj
Jul
Jul
r1ju,
Aug
Sep
ct
Oct €X� H
Nov
Nov
Dec
Dec
€
Jan
Venting
Feb
Mar
Apr
May
Jun
11 Aug
L1
Sep
Oct
Nov
Dec
Thermostat Schedule: HERS
2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM .
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
FOYER BELOW
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST-
Default(8 lbs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/s .ft.
ft2
ft
0.3
M TOILET
4/16/2021 12:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENTPRITERIA
CEIV�p
Project Name: OCCHUIZZO RESIDENCE Builder Name:
Street: TURNPIKE FEEDER ROAD Permit Office: ST LUCIE COUNTY, C
City, State, Zip: FORT PIERCE, FL, Permit Number: Q %'021
Owner: Jurisdiction: ST LUCIE COUNTY
St. Lucie Coun tY
Design Location: FL, Fort Pierce
W
=
U
Permitting
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and Wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. �
4/16/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) r"�pli�nt�Soffiiv (opy Page 1 of 1