HomeMy WebLinkAboutPlan ViewWIND PRESSURE ON COMPONENTS AND CLADDING Zone 1 Zone 1 +/- 16.96 Zone 2 +/- 26.10 Zone 3 +/- 36.27 Zone 1 Zone 2 PROFESSIONAL SERVICES BY DRISCOLL ENGINEERING,INC. PO BOX 357577. GAINESVILLE, FL 32635 PH (352)-331-1513 CA 8690 PLANS AND SPECIFICATIONS The plans and specifications presented herein are applicable only for the anticipated construction at the locations shown. If construction plans change, the Design Professional should be notified so the plans and specifications can be re-evaluated. The Design Professional should be given the opportunity to review final plans and specifications to see if the intent of the plans and specifications has been followed and/or if supplemental details and recommendations are needed. The Design Professional warrants that the plans and specifications contained herein, have been prepared In accordance with generally accepted professional engineering practice. No other warranties are implied or expressed. CORPORATE PROTECTION It Is understood and agreed that the Design Professional's Basic Services under this Agreement do not include project observation or review of the Contractor's performance or any other construction phase services, and that such services will be provided by the Client. The Client assumes all -responsibility for interpretation of the contractor Documents and for construction observation and supervision and waives any claims against the Design Professional that may be In anyway connected thereto. In addition, the Client agrees, to the fullest extent permitted by law, to Indemnify and hold the Design Professional harmless from any loss, claim or cost, including reasonable attorneys fees and costs of defense, arising or resulting from the performance of such services by other person or entities and from any and all claims arising from modifications, clarifications, interpretations, adjustments or changes made to Contract Documents to reflect changed field or other conditions, except for claims arising from the sole negligence or willful misconduct to the Design Professional. OWNERSHIP OF INSTRUMENTS OF SERVICE AN reports, plans, specifications, computer files, field data, notes and other documents and Instruments prepared by the Design Professional as Instruments of service shall remain the property of the Design Professional. The Design Professional shall retain all common law, statutory and other reserved rights,. including the copyright thereto. DEFECTS IN SERVICE The Client shall, promptly report to the Design Professional any defects or suspected -defects In the Design Profession` -Ps work or services of which the Client becomes aware, so that the Design Professional may take measures to minimize the consequences of such a defect. The Client warrants that he or she will impose a similar notification requirement on all contractorsln his or her, Client/Contractor contract and shall require all subcontractors at any level to contain a like requirement Failure by the Client, and the Client's contractors or subcontractors to notifgthe Design Professional, shall relieve the Design Professional of the costs of remedying the defects above the sum such remedy would have cost had prompt notification been given. VERIFICATION OF EXISTING CONDITIONS Inasmuch as the remodeling and/or rehabilitation. of an existing building requires that certain assumptions be made regarding ezlsting conditions, and because some of these assumptions may not be verifiable without expending additional sums of money or destroying otherwise adequate or serviceable portions of the building, the Client agrees, to the fullest extent permitted by law, to indemnify and hold the Design Professional harmless from any claim, liability or cost (including reasonable attorneys fees and costs of defense) for injury or economic loss arising or allegedly arising out of the professional services provided under this Agreement, excepting only those damages, liabilities, or costs attributable to the sole negligence or willful misconduct of the Design Professional 1-AII construction shall comply with Florida Building Code 7th edition 2020. ULTIMATE WIND SPEED: 150 RECEIVED .NOMINAL WIND SPEED: 116 BAN 0 7 2022 WIND EXPOSURE CATEGORY: B RISK CATEGORY 1 NON HABITABLE St. Lucie County Permitting INTERNAL PRESSURE COEFFICIENT Gcpi= +/- 0.0 DESIGN PRESSURE PER FBC CHAPTER 16, INCLUDING ASCE 7-16 LOAD CALCULATIONS ROOF LIVE LOAD =12.5 PSF ROOF DEAD LOAD = 2.5 PSF MIN SOIL BEARING 2000 PSF TRUSS BEARING LOAD EACH END 2200LB TRUSS UPLIFT @ POST 1606LBS 1. Wood framing and fasteners to meet NDS-2018 requirements. 2. Fastener requirements: (1) All nails are Common galvanized; (2) all bolts are to be galvanized steel and include nuts and washers; and (3) all other hardware (Simpson, etc.) is to be installed according to manufacturer's specifications and recommendations. Nailing (size and number) shall satisfy Tables 2306.2.(1), 2306.3.(1) and 2306.3.(#) FBC unless otherwise indicated. Note: fasteners exposed to the weather are to be treated for weather resistance and compatible with the type of pressure treated wood used (connectors, nails, bolts, nuts and washers). Concrete Construction Notes 1. Concrete work shall conform to "Building Code Requirements for Reinforced Concrete" (ACI-318) and "Specifications for Structural Concrete" (ACI-301), Latest Edition. 2. Concrete mix shall conform to the following specifications. All concrete mixes shall contain a water -reducing admixture conforming to ASTM C-494. Air -entraining admixture shall conform to ASTM C-260. CONCRETE MIX A VAiARD 0R�s� Ultimate Compressive Strength @ 28 days 3,000 PSI Slump Range 4" +/- 1n No 43g22 Maximum Aggregate Size 1" , 0 Entrained Air None PTE OF Dry Weight per Cubic: Foot 150 # 3. Shotcrete mix 4 All concrete shall be cured for a minimum of 28 days. If forms for vertical surfaces a t�cY ��riQio the end of the curing period, spray surfaces with liquid membrane curing compound. 5. Reinforcing steel shall conform to ASTM A615, Grade 40 (Fy=40 ksi). Lap continuous bars for tension lap splice per ACI-318, unless otherwise noted. Provide. comer bars of same size and spacing as horizontal wall reinforcement. Cover for concrete reinforcing steel shall be - in accode- with`ACI-318, Paragraph 77. - ` - 6. Welded wire fabric (WWF) shall conform to ASTM A185. Lap sheets two mesh spaces and wire tie adjacent sheets together securely. Cut alternate reinforcement at control joints. 7. All slabs on grade shall have construction or control joints not to exceed 10' - 0" spacing, unless otherwise noted. 8. Electrical conduit and other pipes to be embedded in structural concrete floor slabs or walls shall be placed in accordance with the requirements of ACI-318, Paragraph 6.3. 24' x 48' OPEN,POLE STORAGE STRUCTURE 12-14-21 Michael E Driscoll PE FL Reg # 43922 Z v�3 Z w �. 2 Z A Z Z mp JLdU Z �� K U g 0 d CO W W WQ 0� Z ui U Ur W CM I-- N LL 9 2s n a m C In V BID r FILECu" 1Y 17 7- 11/ ZZ 2,2,01 -Dtsrl -1-------------------- , ' , 1 ' ' 1 , � 1 1 1 1 1 1 1 1 1 4 thick 3000 psi ;concrete slab w/ wwf or fiberm4sh N 6 mil visqueen &;termite treated soil ; (if required) 1 1 1 1 1 1 1 1 1 .;-. -L. .;-. ,. �. -----------------------------r �,---------------------------- ; ;----------------------------- �;--------------------------- ; 8"X 8". pt post 24" dia. x 48" deep \0111111/w/ post footing (typ) ,IAN' --- Sc �i FOUNDATION PLAN VIEW %' O KO SIO R\ ��� III111o�� 12-14-21 Michael E Driscoll PE FL Reg # 43922 Q CL Ca U) o 00 CO CO o0J a ILL zL W9U �C7w ❑ODa 0 U)NLLLL U z � l7 L 2 Z Z W ea z z a W J �J N n O '1 U m9� nz 14 .40 cO 00m M im 00 ®Km Z�® aoZ� 0m 0 FILE COP) 1*1 8"X 811. pt post 24" dia. x 48" deep post footing (typ) SYEEL ROOF TRUSES a of I a. CO N I I X N ROOF PLAN VIEW 12-14-21 Michael E Driscoll PE FL Reg # 43922 CM Q 0 (L CO h 00 Q W o" Q in Y 00U- I W U h=C9w �OC)o a 0 fA CO LL L Z s z W z- ZW z z a W P $$ J J X F Vf p x mum o S� 0 0 ® Xl m MIT �gv 0 M 0 FILE Copy 71l7G�� 2 ZO-1 -0-'u !t r 1 2"x 6" #2 syp purlins @ 24" max spacir FGaly ridge cap 14 Ga purlin 2"x 6" #2 syp Drip edge attach connector purlins attach to clip in accord w/ mfr specifications w/ 2 #10-15 X 1-1/2" screws 1" � 1-1/2" 1 " Truss details (see sheet 5) PURLIN CONNECTION DETAIL J- 114 Uld 1111U UUM nut & washers RIDGE CONNECTION DETAIL 2"x 6" #2 syp purlins @ 24" max spacing r Galy ridge cap 12 29 ga. metal roofing attach in 3 accord with mfr. specifications FL # 9555-R5 ��4 . COLLAR TIE Truss details 2-1/2" dia. carriage thru bolts (see sheet 5) nut & washer to match See sheet 2 &3 for post & footing sizes 4" thick 3000 psi concrete slab w/ wwf or fibermesh 6 mil visqueen & termite treated soil (if required) END ELEVATION NTS 2"x 6" #2 syp purlins @ 24" max spacing 2-1/2" dia. carriage nut & washer to mat See sheet 2 & for post & foot sizes Min 3000psi concrete #5 X 12" BARS CENTERED EACH Vt FOR 18"DIA HOLES USE 12" LONG FOR 24" DIA HOLES USE 16" LONG 80# BAG SACRETE MIN. OR 24" SQ X 4" THICK CONCRETE PAD finish grade POST FOOTING TO TRUSS DETAIL NTS `\\W11111{/���/ Q�ARD DRI � `GV—NgS C0 No F a 10 // 11\ 11-23-21 Michael E Driscoll PE FL Reg # 43922 a O a ca 0 W -? H 00 W aD UjiQ 1 YYp 0aLLL 0 0 Uj W w oo d N (gL~L z 126 ZVT 'Wt1 W Z LU W Z m J J A V Z 0po� ce U F. o g a CA Il— e nmrn 0 0 R9 ®� 9'19 Z�® to Z M 0, 16" 3-9/2�r D Oyp) No. ELEMENT MATERIAL (50 KSI) DESCRIPTION M 1 Collar Tie ASTM 572 L1-1 /2"x 1-1/2" x 3/16" Collar Tie ASTM 572 - 2" 1-1/2" x 3/16" M3 Top Chord ASTM 572 L1-1/2:'x 1-1/2" x 3/16" M4 Bottom Chord _ " _ " " 5 Center vertical ASTM 572 1 " " " M6 End Vertical ASTM 572 L 1-1/2"x 1-1/2" x 3/16" M7 Bearing angle ASTM 572 L 1-1 /2"x 1-1/2" x 3/16" M8 Inside vertical ASTM 513 L1-1/4"x 1-1/4" x 1/8" M9 Diagonal web ASTM 513 L1-1/4"x 1-1/4" x 1/8" STEEL TRUSS CROSS SECTION NOTES: CONNECTOR SCHEDULE 2"x 6" #2 syp purlin to 6"x 6" x 14 ga. clip 249 x 1-1/4" screws Truss to truss @ ridge 3-1/2" dia thru baits & nut Wood post to truss- 21/2" dia thru bolts nut & washers Post to concrete 24" dia x 48" deep w/ 2 #5 bars thru post 1-MATERIALS SHALL CONFORM TO STEEL ASTM 572. 2- ALL STEEL SHALL BE 50ksi -IN-ACCORD WITH CURRENT AISC-MANUAL. 3- WELDING ELECTRODES TYPE. E70XX 4- ALL WELDING SHALL BE IN ACCORD WITH CURRENT AWS REQUIREMENTS. 5-ALL WELDING SHALL BE DONE BY A CERTIFIED WELDER. 6-BOLTS SHALL BE ASTM A325. w/ NUTS & WASHERS. (TYP) 7- WELD STRENGTH 70 KSI MIN. 8- ALL POST SHALL BE #2 DENSE PRESSURE TREATED GROUND CONTACT. 9- PRIMING & PAINTING SHALL BE DONE BY TRUSS MANUFACTURER. 10- MIN EDGE DISTANCE FOR BOLTS HOLES SHALL BE 3/4" MIN 11-MAX TRUSS SPACING SHALL NOT EXCEED 12'-0" UNO. 12-THE DESIGNER DISCLAMS ANY RESPONSIBILITY FOR DAMAGES AS A RESULT OF POOR WORKMANSHIP, OR IMPROPER USE, AND ACCEPTS NO RESPONSIBILTY OR EXERCISES NO CONTROL WITH REGUARD TO FABRICATION, HANDLING,AND INSTALLATION OF TRUSSES: 2- 1 /2" DIA. CARRIAGE BOLTS NUT & WASHF-- — STEEL TP COPS ' PURLIN (TYP) TRUSS TO POST DETAIL PLAN VIEW O )olts 0- U) H o0 ¢w�rn > C0 CA cnm n YQ� 0, vvuodFiRD DR�S� nOt sh wnt Z Z W m m v`G�NsE```o� for clarity W n �; N� 43g22 I=— w _ ::) 00 a C S�PiE°F ;"�� cOnN�r ��s 10N � ee��� � m 00 n m u __ — 0: Z RE w U MN _ TRUSS DETAILS a � WZ.�. ! J J 2� -V - J r o �, Z L R U oW 12-14-21 ° aZ Michael E Driscoll PE FL Reg # 43922 qAP